Zurn Z6200PL-HET Installation Guide

image

Contents

1. ZURN Metroflush hf A tht 26200 Series Metroflush Piston Operated Flush Valve Installation Operation Maintenance and Parts Manual Patented and Patents Pending Metroflush Piston Operated Flush Valve 26200 26201 26203 26210 LIMITED WARRANTY All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase Decorative finishes warranted for one year We will replace at no cost goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights stated in our catalogs and lists a
2. p valve 2 Open supply valve Insufficient volume of water to adequately siphon fixture Stop valve is not open enough Urinal piston installed in closet valve Insufficient volume or pressure at supply 1 Open stop valve for desired volume of water 2 Replace urinal piston with proper closet piston 3 Consult fixture guide for minimum gallons per minute flow and running pressure for satisfactory fixture performance Flush valve shuts off too quick Valve is short flushing Damaged piston Enlarged by pass orifice Enlarged by pass orifice 1 Install new P6200 EC P6200 EU replacement kit to remedy the problem 2 Install new P6200 EC P6200 EU replacement kit to remedy the problem Install new P6200 EC P6200 EU replacement kit to remedy the problem 1 2 Urinal piston in closet flush valves 2 Install closet piston Item 13 Valve is flushing too long or 1 Trip mechanism not seating properly 1 Disassemble parts and rinse thoroughly not shutting off due to foreign material between trip mechanism and seat 2 By pass orifice is plugged or partially 2 Examine by pass orifice and clean if necessary plugged being certain not to enlarge orifice opening 3 Line pressure is not adequate to force 3 Pressure is inadequate or has dropped below trip mechanism to seal minimum operating range Steps should be taken to increase the line pressure Water splashes out of fixtu
3. pair Guide Lia na S Q I 26200 Series heady Nia J Parts Identification 1 Handle Nut 2 Handle Sleeve 3 Handle Insert 4 Low Force ADA Compliant Handle 5 Actuator Rod 6 Handle O Ring 7 Handle Spring 8 Handle Seal Retainer 9 Handle Seal 10 Gasket 11 Valve Body Cover 12 Valve Body Cover Gasket 13 Internal Kit 14 Main Seat 15 Valve Body 16 Vacuum Breaker Friction Washer 17 Vacuum Breaker Insert 18 Vacuum Breaker Duckbill 19 Vacuum Breaker Tube 20 Vacuum Breaker Tube Nut 21 Spud Nut 22 Spud Friction Washer 23 Spud Sleeve 24 Spud Escutcheon 25 Tailpiece 26 Snap Ring 27 Tailpiece O Ring 28 Locking Nut 29 Vandal Resistant Control Stop Cover l P6000 D Stop Valve Repair Kit oT SPA S amp Dib in N 30 Stop Cap 31 Adjusting Screw 32 Guide Holder 33 Piston Guide 34 Guide O Ring 35 Stop Spring 36 Piston 37 Piston Seal 38 Stop Body 39 Sweat Solder Adaptor 40 Supply Cover Tube 41 Cast Wall Escutcheon be Covers and Repair Kits Product No Handle Assembly and Repair Kits Product No Adjustable Tailpieces Product No Outside Cover CP Item 11 P6200 LL ADA Handle Assembly Side Includes I
4. re 1 Supply volume is more than is 1 Adjust downward on control stop necessary 2 Lime accumulation on vortex or 2 Remove the lime build up spreader holes of fixture Flush is not considered quiet 1 Control stop may not be adjusted for 1 Adjust the control stop for quiet operation quiet operation keeping in mind the fixture evacuation requirements 2 Fixture may be contributing to noise 2 Check noise created by fixture by placing a cover over the bowl opening to separate valve noise from bowl noise If it is determined the fixture is too noisy consult with fixture manufacturer 3 Piping system may be source of noise 3 High pressure in the system can sometimes be controlled by the stop valve Other sources of noise may be the absence of air chambers and shock arrestors loose pipes improper size pipes etc In these cases the building engineer should be consulted Handle assembly leaking Handle assembly is not tight 1 Tighten handle assembly In Canada ZURN PLUMBING PRODUCTS GROUP COMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC U S A 27330 PHONE 1 800 997 3876 FAX 919 775 3541 WEBSITE www zurn com ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE MISSISSAUGA ONTARIO L4V 1L2 PHONE 905 405 8272 FAX 905 405 1292
5. re approximate and are not guaranteed 7 Install stop valve using proper supply escutcheon and sweat solder kit if applicable 3 Flushing of supply lines by using the following procedure is recommended after installation of all valves A Close stop valves by using adjusting screw behind adjusting screw cover Do not remove stop valve cap B Remove main valve body cover and working part from flush valve C Replace only main valve body cover Tighten main valve body cover D Open the stop valve by using the adjusting screw until debris is purged E Shut the stop valve replace working part and retighten cover 2 Insert flush valve tailpiece into stop valve being certain 0 ring seal is in place Wet seal with water to lubricate Hand tighten locknut Determine length of vacuum breaker tube required and cut as necessary Assemble vacuum breaker tube assembly between flush valve and fixture spud Set flush valve for proper operation by adjusting stop valve Stop valve adjustments can only be made by using the adjusting screw located behind the adjusting screw cover Water must be shut off at main supply valve if stop cap is to be removed Final setting should provide enough water flow to evacuate a closet fixture and should be such that a urinal fixture will not overflow when continually flushed Secure adjusting screw cover Metroflush Parts Replacement amp Re
6. tems 2 10 P6000 M Adjustable Tailpiece for Standard Flush Valve Outside Cover O Ring Item 12 P6200 L12 Handle Repair Kit Side Includes Items 5 10 P6000 MK Includes Items 25 27 P6000 J1 Closet Repair Kit Item 13 P6200 EC Handle Seal Includes Item 9 P6000 M9 Tailpiece Coupling Assembly Includes Items 26 28 P6000 K Urinal Repair Kit Item 13 P6200 EU Handle Gasket Includes Item 10 P6000 M10 Tailpiece Locking Ring Includes Item 26 P6000 C30 Low Consumption Closet Kit Item 13 P6200 EC WS1 Tailpiece O Ring Includes Item 26 P6000 C31 Control Stop Repair Kit and Parts Product No i Low Consumption Urinal Kit Item 13 P6200 EU WS1 Coupling Nut Includes Item 28 P6000 C32 Control Stop Repair Kit for 1 and 3 4 Main Seat Item 14 P6200 E14 Includes Items 31 37 P6000 D SD Flush Connections and Spud Coupling Kits Product No Seal Seat for 1 and 3 4 Includes Item 37 P6000 D42 Flush Tube Assembly for Flush Valves VP Control Stop Repair Kit for 1 and 3 4 Includes Items 16 20 P6000 A Includes Items 31 37 P6000 D VP Specify diameter and length 1 1 2 1 1 4 3 4 Vandal Resistant Cover Includes Item 29 P6000 VC Vacuum Breaker Repair Kit Includes Items 16 18 P6000 B Spud Coupling Assembly Includes Items 21 24 Specify size 1 1 2 1 1 4 3 4 P6000 H MetroFlush Service Instructions PROBLEM Valve will not operate Stop valve is closed Supply valve is closed CORRECTIVE ACTION 1 Open sto