1. Use Sensor Distance Adjustment Screw Adustment Tool Provided Modes of Delay Flush amp 24 HR OFF Normal operation 0 t ON Delay before flushing and ere ION OFF 0N unit flushes every 24 hours Switch after last user Upject Detection Range Distance Adjustment OL O9 Far TROUBLE SHOOTING GUIDE PROBLEM Yellow L E D light flashes 3 times when there are no users Yellow L E D light flashes continu ously when Object Lock Sensor is activated by a user Red L E D light flashes Not enough water to fixture or too much water to fixture Valve will not operate Valve does not shut off Valve does not flush even after Object Lock Sensor has been adjusted Front of Object Lock Sensor is covered or Object Lock Sensor is set too far out registering the opposite wall or door as a user E Z Flush unit is in 10 minute start up mode when first acti vated or Sensor Range Reset Button has been depressed Batteries need replacing Diaphragm damaged or valve control stop improperly adjusted Object Lock Sensor range set too close to E Z Flush batteries are dead or water supply is turned off Dirt or debris preventing dia phragm from functioning properly Batteries are dead SOLUTION Remove item covering sensor or adjust Object Lock Sensor activation distance See Appendix B Adjusting the E Z Flush Yellow L E D light w
2. reinstalling the working parts D Open the stop valve by using the stop adjusting screw and flush out all debris from pipe and connections E Shut stop open cover reinstall the working parts replace both covers and tighten This procedure should also be repeated when the system is drained for seasonal use as occurs in athletic fields recre ation parks etc FV237 Rev E 11 9 11 Page 4 10 The ZER flush valves are preset for fixture volume as marked on the valve cartons The valve does not require regulation for variation in water pressure within its operating range To set the flush valve for proper operation gradually adjust the stop valve open using the adjusting screw while actuating the valve until the rate of water flow into the fixture is not excessive yet is sufficient to adequately evacuate the waste The final setting for urinals should be such that the fixture will not overflow when the valve is actuated in succession The stop cap screw cover should be replaced after final adjustments have been made APPENDIX A TO CHANGE ACTIVATION DISTANCE FOR THE OBJECT LOCK SENSOR 1 Remove battery compartment tray as shown in Step 6 2 Remove cover and sensor adjustor tool as shown in Step 6 3 Replace battery compartment in E Z Flush to activate unit 4 Press sensor range reset button the yellow L E D will flash continuously when it has an object in view for the 10 mi
3. the locking nut D and locking snap ring E are located as shown Care should be taken not to damage the O ring when inserting the tailpiece into the stop valve If lubrication is needed wetting the O ring with water will be sufficient FV237 Rev E 11 9 11 Page 2 3 Insert the flush valve tailpiece B into the stop valve A and hand tighten the lock nut D to the stop valve Plumb the entire unit at KOO N Vacuum eter n w LF x A 1 AIO IG Spud Nut Slip Gasket Rubber S asket poud Escutcheon 4 Determine the length of vacuum breaker tube F required to join the flush valve and fixture spud Cut the vacuum breaker tube if required to this length Assemble the vacuum breaker tube assembly and spud nut assembly to the flush valve and fixture spud 5 Hand tighten spud nut and vacuum breaker tube nut to fix ture and flush valve Adjust the valve assembly for plumb Tighten fixture spud nut vacuum breaker tube nut and lock nut with a wrench Do not turn water on until batteries are in serted see 6 ACTIVATION Using supplied battery compartment wrench remove battery compartment from the E Z Flush unit Load batteries into compartment tray note position of batteries in tray and reinstall battery tray into the E Z Flush unit Secure tray with ba
4. AquaSense AV ZER Series Automatic Sensor Operated Battery Powered Flushometer Installation Operation Maintenance and Parts Manual Patented and Patents Pending ZER6000AV CP ZER6000AV CPM Sensor Operated Battery Powered Closet Urinal Systems ZER6003AV CP ZER6000AV CPM ZER6000AV WS1 CPM ZER6003AV CPM ZER6001AV CPM ZER6001AV WS1 CPM ZER6003AV CPM ZER6003AV WS1 CPM LIMITED WARRANTY All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase Decorative finishes warranted for one year We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantabil
5. H BUTTON Allows manual activation of flush when needed 8 ADJUSTING YOUR E Z FLUSH STEP A Use battery compartment STEP B Pull cover off by rotating battery STEP C Sensor Adjustor Tool comes in wrench to remove battery compartment side forward and out a built in storage pocket Replace after use tray FV237 Rev E 11 9 11 Page 3 Before the supply water is turned on be sure all stop valves to the flush valves are closed off tight The stop valves can be opened and closed by using the adjusting screw located at the center of the stop valve cap T behind the adjusting screw cover if already installed Stop valve adjustments can only be made by using the adjusting screw It is not necessary to remove the stop valve cap when making adjustments If for any reason it becomes necessary to remove the stop valve cap be certain the water is shut off at the main supply valve New RetroFlush Diaphragm Kit 9 When all flush valves are connected to the fixtures and water pressure Is available it is recommended that the supply piping be flushed to remove dirt pipe chips etc from system Use the following procedure to flush out the supply piping A Remove the main valve body cover O B Remove the working parts from the flush valve P and Q shown in 9b C Replace the plastic cover P and main body cover O with out
6. ill flash only 3 times acknowledging a user is in view after the 10 minute start up mode Replace batteries Replace diaphragm and or adjust valve control stop Adjust Object Lock Sensor replace batter ies or turn water on If the E Z Flush does not begin to function call Customer Service at 1 800 997 3876 Remove dirt or debris check by pass hole in diaphragm Replace batteries If the E Z Flush does not begin to function call Customer Service at 1 800 997 3876 FV237 Rev E 11 9 11 Page 5 Part Identification Seal Collar Gasket Sensor Module Manual Overide Push Button Replacement Sensor Lens Chrome Plastic Cover Chrome Metal Cover Battery Drawer O Ring 10 Allen Wrench 11 Handle Nut Wrench 12 Valve Body Cover 13 Plastic Cover 14 Trip Mechanism 15 Diaphragm Repair Kit 16 Valve Body 17 Vacuum Breaker Duckbill 18 Vacuum Breaker Tube 19 Vacuum Breaker Tube Nut P6000 ECA o P6000 EUA KITS OOnNDOBRWDND 20 Spud Nut 21 Spud Friction Washer 9 lt 22 Spud Sleeve 3 23 Spud Escutcheon 24 Tailpiece 25 Snap Ring 26 Tailpiece O Ring 27 Locking Nut 28 Setscrew for Cast Wall Flange 29 Cast Wall Escutcheon 30 Supply Cover Tube P6000 H 31 Sweat Solder Adapter 32 Stop Body 33 Piston Seal 34 Piston 35 Stop Spring 36 Guide O Ring 37 Piston Guide 38 Guide Holder 39 Adjusting Screw 40 Stop Cap 41 Sna
7. ity is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights stated in our catalogs and lists are approximate and are not guaranteed PRIOR TO INSTALLATION Prior to installing the ZER Flushometer install the items listed below e Closet or urinal fixture e Drain line e Water supply line IMPORTANT ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS e WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE FLUSH ALL WATER LINES PRIOR TO OPERATION See Step 9 DIRT AND DEBRIS CAN CAUSE FLUSH VALVE TO RUN CON TINUOUSLY The ZER is designed to operate with 20 to 80 psi 138 to 552 kPa of water pressure THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED Consult fixture manufacturer for pressure requirements Protect the chrome or special finish of this flushometer DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE 1 Install stop valve assembly A using proper size supply escutcheon and sweat solder adapter kit if applicable Thread sealing compounds should be used on male NPT threads only 2 Prior to inserting the flush valve tailpiece B into stop valve be certain that the O ring seal C is located in O ring seal groove at the end of the tailpiece and
8. nute reset period 5 Stand at desired activation distance 6 Use sensor adjustor tool and turn Distance Adjustment Screw all the way down and then turn slowly up until yellow L E D begins to flash 7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door stepping out of sensor path and making sure yellow L E D is not flashing If sensor locks onto door or wall unit will not flush properly Shorten activation distance 8 Remove battery compartment replace sensor adjustor tool and cover Replace battery compartment tray to reactivate E Z Flush unit 9 After 10 minute start up sequence the yellow L E D will flash only 3 times when a user is in view after a 5 second delay WIRING DIAGRAM Low Batte Flashing L gnc ry LE FD Change batteries D Red User In View LED Yellow Flashes 3 limes User is recognized ready to operate once user leaves a m O XO N MANUAL FLUSH ass Lo o oa Delay Flush User must TO leave the sensor range for 3 seconds before a flush is e generated A 24 Hour Flush Unit will automatically flush 24 hours after the last use
9. p Cap Screw Cover 42 Vandal Resistant Control Stop Cover 43 Setscrew for Control Stop Cover Water Saving Urinal Kit 1 5 gal flush Control Stop Repair Kit and Parts Product No Control Stop Repair Kit for 1 and 3 4 P6000 D SD Includes Items 33 39 Seal Seat for 1 and 3 4 Includes Item 33 P6000 D42 VP Control Stop Repair Kit for 1 and 3 4 P6000 D VP Includes Items 33 39 Sweat Solder Connection with Cast Wall Flange P6000 YBYC Includes Items 29 31 Adjustable Tailpieces Product No Adjustable Tailpiece for Standard Flush Valve P6000 J1 Includes Items 24 26 Repair Parts Inside Parts Product No P6000 EU13 P6000 EC13 P6000 K P6000 C30 P6000 C31 P6000 C32 Items 15 19 Specify Diameter and Length Spud Coupling Assembly Includes Items 20 23 P6000 H Specify Size Product No PERK6000 L CPCR PERK6000 L CPMCR PERK6000 SCR PERK6000 BD PERK6000 RK Repair Kit Includes Items 1 2 Retainer PERK6000 MRK and Cup Seal Sensor Module PERK6000 SR ZURN INDUSTRIES LLC COMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC 27330 PHONE 1 800 997 3876 FAX 919 775 3541 WORLD WIDE WEB WWW ZURN COM IN CANADA ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE MISSISSAUGA ONTARIO L4V1L2 PHONE 905 405 8272 FAX 905 405 1292 FV237 Rev E 11 9 11 Page 6
10. ttery compartment wrench The last three turns of the wrench will activate the E Z Flush unit The E Z Flush System is now operational Your E Z Flush unit comes preset from the factory If special circumstances require adjustment of the activation distance see Appendix A Adjusting Your E Z Flush The E Z Flush unit has a 10 minute start up sequence in which the Object Lock Sensor will flash the User In View yellow L E D continuously as long as a user is in view After the start up sequence is completed and when the Object Lock Sensor has a user in view the User In View yellow L E D will flash only 3 times after a 5 second delay This delay prevents needless flushes when someone walks by Sensor units should not be located across from each other or in close proximity to highly reflective surfaces 7 VISUAL INDICATOR GUIDE USER IN VIEW L E D Yellow light flashes 3 times after 5 second delay when a user is in view The yellow light flashes constantly when a user is in view during the 10 minute start up sequence C MANUAL FLUSH OBJECT LOCK SENSOR BATTERY L E D Red light flashes indicating it is time to replace batteries with 4 new C batteries COURTESY MANUAL FLUS

Download Pdf Manuals

image

Related Search

Related Contents

名 VR-A410 - JVCケンウッド  Lenmar Enterprises 50L20 User's Manual  Palmarès Concours Général Agricole  非常 ・ 業務兼用形リモコン操作器取扱説明書  取扱説明書 - お客様サポート  ロータリー SXR02  IDEC FC5A Advanced Manual  Comida equilibrada en barritas Barras de  User's Manual - Computation - Lawrence Livermore National  Istruzioni per l`uso  