Home

WarmlyYours TH114-AF-GA Installation Guide

image

Contents

1. aube technologies TH114 User s Guide Non programmable Thermostat 1 Description Aube s TH114 Series non programmable thermostats can be used to control ambient or floor temperature The following models are available A model gt controls and displays the ambient temperature F model gt controls and displays the floor temperature gt uses an external temperature sensor AF model gt controls and displays the ambient temperature gt maintains the floor temperature within desired limits gt uses an external temperature sensor GFCI fault light Actual or setpoint Arrow appears temperature when the setpoint is displayed GFCI fault indicator Power output 1to 24 25 to 49 Temperature 50 to 74 adjustment button 75 to 99 GFCI test button 100 Backlight button On Standby button available on certain models only Each thermostat consists of a control module which must be mounted on a PB112 Series power base For the selection and installation of the power base refer to its installation instructions 2 DIP Switch Configuration The DIP switches are located at the back of the control module 2 1 Temperature Display S1 To switch between C and F 2 2 Model 2 Note Available on certain models only F To select the F model AF To se
2. its are factory set at 10 C 50 F and 28 C 82 F respectively To modify the limits proceed as follows Switch the thermostat to Standby While pressing any button switch the thermostat back to On to access the floor temperature limit settings Press the Test button briefly to switch between minimum and maximum floor temperature settings Press the A W buttons to set the desired limit Press the Test button for 3 seconds to save your modifications After the data are saved the thermostat displays the actual ambient temperature or Note Your modifications are also saved if no button is pressed for 60 seconds Switch the thermostat to Standby and back to On to reset the GFCI and return to the normal display TH114 8 Technical Specifications Power supply Refer to the power base installation instructions Ambient setpoint range A AF models 5 C to 30 C 40 F 86 F Floor limit range AF model 5 C to 40 C 40 F 104 F Floor setpoint range F model 5 C to 40 C 40 F 104 F Setpoint resolution 0 5 C 1 0 F Display resolution 0 5 C 1 0 F Duty cycle Refer to the power base installation instructions Storage 20 C to 50 C 4 F 120 F AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase During this period AUBE Technologies Inc
3. lect the A or AF model TH114 3 Installation Refer to the installation instructions of the power base insert the tabs at the top of the control module in the slots at the top of the power base Secure the control module using the cap tive screw underneath the base Note Do not obstruct the thermostat s vents As soon as the thermostat is powered it undergoes a series of tests before displaying the actual tempera ture J Error Messages g The measured temperature is below 0 C 32 F Heat ing is turned On _ _ _ _ _ The measured temperature is above 50 C 122 F A or AF model or 60 C 140 F F model The floor sensor is defective or not properly connected F model only or the thermostat is defective 6 GFCI Test Note This procedure must be performed if the thermostat is mounted on a GFCl equipped power base Test the GFCI immediately after installing the control module and once a month there iat after 7 3 Raise the temperature A until the heat oe ing power indicator j appears Press the Test button ifthe test is successful you will hear a click caused by the GFCI relay tripping y The heating power indicator will disap wa pear GFI will appear and the Fault light c gt _ 8 will illuminate Reset the thermostat by switching it to Standby and back to On ifthe test has failed cut power to
4. re the power base to the electrical box using the provided screws If necessary set the configuration switches on the control module refer to the control module user guide Install the control module onto the base OO 890 Apply power to heating system PB112 Figure 1 Figure 2 on ite SENSOR N Technical Specifications Woas Supp wax twa Power vanna oF 240 VAC 50 60Hz 3600 W 240GA 508 VAC 50 60Hz 3120 w AW DP ar 240 VAC 50 60Hz 3600 W 240GB 208 VAC 50 60Hz 3120 w AW DP 240 VAC 50 60Hz 4000 W 240S 208 VAC 50 60Hz 16 7A 3475 w 4WISP a 240 VAC 50 60Hz 3600 W 240D 208 VAC 50 60Hz Oa 3120 w 4WDP m Storage 4 F to 120 F 20 C to 50 C Remote controller input ECONO requires a dry contact Size H W D 4 89 x 2 76 x 0 91 in 124 x 70 x 23 mm Models Models Certifications GF 120 GA GB Gi 120S 240S c US 240 GA GB i US LISTED 240D 400 112 006 B 1 6 05 1 1
5. tallation should be carried out by an elec trician gt High voltage thermostats must be installed onto an electrical box gt For a new installation choose a location about 5 ft above the floor and on an inside wall gt The thermostat must be installed on an inside wall facing the heating system except for floor heating systems gt Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimneys or stove pipes except for floor heating systems Procedure Connect the power base wires to the power supply and load using sold erless connectors for copper wires figure 1 if your thermostat is type F or AF not A insert the floor sensor wires through one of the two holes below the terminals figure 2 and connect the wires to terminals 3 and 4 no polarity The wires must run alongside the terminals and not go over them The wire must not cross any heating wires nor be placed directly on a heating wire or adjacent to it For best performance the sensor probe should be centered between the wires in the mat i you wish to use a remote controller such as the CT240 or CT241 insert the cable use 18 to 22 gauge flexible wires into one of the two holes available below the terminal board and connect to terminals 1 and 2 of the base figure 2 Push the excess length of the high voltage wires back into the electrical box Secu
6. the heating system from the main electrical panel and call customer service Note If the Fault light is On during normal operation cut power to heating system at the main electrical panel and have an electrician verify the installation 400 114 000 B 21 2 05 1 2 7 Operation 7 1 Backlight When either of the A W buttons is pressed the display is lit for 10 seconds The setpoint appears for 5 seconds then the actual tem perature is displayed When the backlight button is pressed the display is lit for 5 sec onds NOTE f the thermostat is mounted on a GFCl equipped power base this button is used for the GFCI test 7 2 Displaying and Setting the Temperature The thermostat normally displays the actual temperature To view the setpoint press once on one of the A W buttons The setpoint is displayed for 5 seconds During the setpoint display press one of the A V buttons to change it To scroll the setpoint faster press and hold the button 7 3 Setting the Floor Temperature Limits AF model only The thermostat generally turns heating On or Off to con trol the ambient temperature However if the floor tem perature drops below the set minimum floor temperature limit or rises above the maximum limit the thermostat will turn heating On or Off respectively regardless of the ambient temperature to maintain the floor temperature 10 within the desired limits CO The minimum and maximum floor temperature lim
7. will repair or replace at our option and without charge any defective product which has been used under normal conditions The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installa tion This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commit ment AUBE Technologies Inc cannot be held liable for related or random damages following the installation of this product The defective product as well as the purchase invoice must be returned to the place of purchase or mailed prepaid and insured to the following address 705 Montrichard Saint Jean sur Richelieu Quebec J2X 5K8 Canada T 450 358 4600 1 800 831 AUBE 2823 F 450 358 4650 service aubetech com For more information on our products visit us at www aubetech com 400 114 000 B 21 2 05 2 2 technologies ab PB112 Installation Instructions For models 120GA 120GB 120S 240GA 240GB 2408 240D Parts one 1 power base Two 2 screws Four 4 solderless connectors for copper wires NOTE Special CO ALR solderless connectors must be used for connecting aluminum conductors one 1 floor sensor and one 1 flat tip screwdriver F and AF floor heating models only Guidelines Turn off power to the heating system at the main electrical panel to avoid electrical shock The ins