Home

Amana WS900E Installation Guide

image

Contents

1. 3 Grasping the top and bottom flanges of the rear clo sure panel as shown in Figure 9 the entire panel is pulled out diagonally from one side Install the wall sleeve condenser air grille by using the screws and holes provided See the Installation Instruc tions provided for the grille kits Figure 8 Rear Enclosure Panel wv Figure 9 Panel Removal WALL SLEEVE INSTALLATION After the wall opening is checked and approved for location size and clearances complete the following to install the wall sleeve 1 Remove the outside enclosure panel from the wall sleeve Slide the wall sleeve into the wall opening Do not dis tort the cabinet shape to fit the wall opening the unit chassis must fit snugly and uniformly into the wall sleeve Locate the sleeve within the range of minimum pro jections as shown in Figures 3 and 4 so both sides are at least the minimum projection from the wall Check the level of the wall sleeve For proper drain age the sleeve should be level from side to side and one quarter bubble in the sight glass sloping to the outside Two holes will need to be drilled in both sides of the wall sleeve for mounting into the wall Drill holes of proper size and in the proper location so the screws will engage into strong supporting members of the wall DO NOT DRILL THROUGH BOTTOM OF SLEEVE Figure 10 shows possible fastening meth ods Alternative Fastening Method Field Supplie
2. Minimum Lintel TOWARD THE ROOM Figure 5 Lintel Projection e The installer must determine and supply the mounting bolts and or screws to attach the wall sleeve to the sides of the wall opening Make sure the wall opening is adequate for strong support e The installer must provide adequate sealing and insulation around the sleeve after it is installed See Figure 6 for one of many types of construc tions e If used a 208 230 volt wall receptacle must be located within 58 inches of the lower right sleeve corner Extension cords must not be used with the unit See the note on Figure 1 e For installations in walls deeper than 13 7 8 inches special care is necessary to prevent problems with rain water condensate drainage Figure 6 Block and Brick Veneer and intake discharge air Under these circum Installation stances careful job site analysis and precautions are required You must consult with your Sales Representative and receive approval before Sleeve attempting such installations Stiffener Caulk Top Bottom and Both Sides Power Supply Conduit Receptacle Outpoor Enclosure PANEL REMOVAL The sleeve stiffener must be taken out before the enclosure panel can be removed from the sleeve 1 Remove the zig zag folded cardboard sleeve stiffener Figure 7 2 Remove the rear closure panel by folding the four Figure 7 Sleeve Stiffener Remova flaps as indicated in Figure 8 Rear Closure
3. PTAC WaLL SLEEVE INSTALLATION INSTRUCTIONS The wall sleeve must be installed before the air conditioner or heat pump chassis can be set in place Read the instructions thoroughly before proceeding When 230 208 volt units are to be installed the power supply may be either cord connected or permanent wiring Permanent wiring may be done through the hard wire junction box or the accessory subbase When 265 volt units are to be installed the power supply must be permanent wiring Permanent wiring may be done through the accessory hard wire junction box or the accessory subbase An exposed cord connection on 265 volt units is not permitted The subbase accessory includes leveling legs If added wall sleeve support is required and the subbase is not to be used an accessory leveling leg kit may be installed Made in USA Contents KIT ACCESSORIES cccssseseecssseeeececesseueensneeeseneaeeeeeusuessseueenuuseueeneuseueeneausesenseuseseneas 2 DRAIN KIT eu aes nonan a a o a a aa aaa E 2 SupsBaseE Levetinc Leas Main Duct AND Hypronic HEAT KITS 00000s0eeeeees 2 PRE INSTALLATION CONSIDERATIONS sc ccccccssseseseecnseeseusneseseseesenseeseeseneseeses 3 OUTDOOR ENCLOSURE PANEL REMOVAL 00scccceseeecnseeccnseesnseeeeeuseseeeceeenseeseneesenas 3 WALL SLEEVE INSTALLATION 0 c cccssseeseccssseseucnsseseueeeasseseeeaeseseeeneasseeeeossenseoanses 4 A RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION ATTENTION INS
4. TALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer This includes all safety precautions and related items Prior to actual installation thoroughly familiarize yourself with this Instruction Manual Pay special attention to all safety warnings Often during installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation Remember it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use Safety is a matter of common sense a matter of thinking before acting Most dealers have a list of specific good safety practices follow them The precautions listed in this Installation Manual are intended as supplemental to existing practices However if there is a direct conflict between existing practices and the content of this manual the precautions listed here take precedence Part No A3495105 August 2005 Printed in USA KIT ACCESSORIES Drain Kit An indoor outdoor drain kit is available as an accessory item When a drain kit is to be installed do so before installing the wall sleeve in the wall See the drain kit for actual installation instructions SuBBase LEVELING Leas Main Duct AND Hypronic Heat Kits Installation of these kits requires drilling of mounting holes on both sides of the wall sleeve T
5. d Mounting a ate Bolt Holes lt Expansion Drilled by Sen _ Anchor Bolt Installer x Plastic Yens Anchor Figure 10 Wall Sleeve Attachment to Opening 6 Check the level of the wall sleeve and adjust if neces sary Caulk or seal around the outside of the entire sleeve If the unit chassis will not be installed immediately re place the enclosure panel on the outside opening of the sleeve This will prevent weather damage to the building interior Recycle or dispose of packaging materials per local codes
6. he minimum required clearance distance between the wall sleeve and wall is shown in Table 1 If the distance between wall sleeve and wall will be at or near the minimum clearance distance mount these kits on the sleeve before installing the sleeve in the wall The kit installation instructions are included with the accessory kits Finished Floor Dimension B bi po Figure 2 Minimum Wall Opening Dimensions Outside 16 1 16 Wal 410 mm p romanso Internal N Internal Adjacent j Wall A A Wal Minimum Minimum Allow Front Clearance See Table 1 Wall Receptacle Within 58 From Bottom Right Side Corner on 208 230 VAC Units Only Figure 3 Minimum Unit Clearances 2 Room Outside Side Wall C in Table 1 Carpet or Finished Floor B in Table 1 Figure 1 Wall Sleeve Dimensions Cabinet Side 1 4 6 mm Minimum Figure 4 Minimum Interior and Exterior MINIMUM CLEARANCES AND PROJECTIONS MINIMUM CLEARANCES MINIMUM PROJECTION OPTION Afi ure 2 B Figure 3 C Figure 4 mm_ Inches mm_ Inches mm Wall Sleeve Only ee E E E E E E Subbase Kit 3 1 4 2 3 4 Duct Kit CC sa S o o 238 35 Hydronic Heat Kit A Series 9 230 0to31 4 otos5 3 75 Hydronic Heat Kit J Series 6 150 O o 21 2 65 Drain Kit Cs da Te oC g Co l Hardwire Kit 3 7 114 3 0 1 If inside mounted then B 1 1 2 inches 40 mm 2 To achieve a flush fit be
7. tween the hydronic front and the finished wall Dimension C must be between 3 and 3 1 8 If this dimension is more than 3 1 8 there will be a gap between the front and the wall This gap could permit occupant access to hydronic lines or other dangerous parts 3 This dimension can be from 0 to 3 1 4 but cannot exceed 3 1 4 If this dimension exceeds 3 1 4 the skirt around the front will not reach the floor Table 1 2 PRE INSTALLATION CONSIDERATIONS Before proceeding with the sleeve installation ensure the following guidelines for locating the wall opening and sleeve are met e The wall opening must be the correct size See Figure 1 for wall sleeve dimensions and Figure 2 for minimum wall opening size e The wall sleeve will need to be installed with minimum clearances to the floor and adjacent walls Minimum projections of the sleeve into and out of the room will also have to be met See Figures 3 and 4 as well as Table 1 for details e Ifinstalled in a concrete or masonry wall a lintel must be provided in the wall opening for support Do not use the wall sleeve as a lintel See Figure 5 for a typical lintel construction e When installed in the opening the wall sleeve Figure 5 Framing with Lintel must be horizontally level from side to side and pitched one quarter bubble in the sight glass to the outside DO NOT SLOPE THE WALL SLEEVE bas corti Maximum Concrete No Accessories 1 4 6 mm