Home
GE PT9050SFSS Instructions / Assembly
Contents
1. 68 6 cm 30 76 2 cm 25 63 5 cm min 25 64 1 cm m x 27 70 2 cm min 28 71 4 cm m x 1 2 5 cm Ancho de la abertura Altura de la abertura Superposici n del horno sobre los costados laterales de la abertura A Espacio respecto de esquinas adyacentes cajones paredes etc cuando la puerta est abierta 20 50 8 cm m n Superposici n de la 1 2 5 cm m n parte superior del horno de la abertura Superposici n de la parte inferior del horno de la abertura 1 2 5 cm m n Ubicaci n de la caja 8 22 2 cm m x de conexiones s lo lado derecho 28 72 4 cm m n 28 72 7 cm m x 27 69 2 cm m n 27 69 4 cm m x 1 6 1 75 cm 21 53 3 cm min 1 2 5 cm m n 1 3 2 cm 9 24 1 cm m x s lo lado derecho ABERTURA PARA HORNOS NICOS BAJO EL MOSTRADOR DE ENCIMERA NOTA Estos hornos s lo pueden instalarse bajo los modelos espec ficos como se indica en la etiqueta de la unidad Pueden instalarse estufas a gas o el ctricas sobre este horno Ver las instrucciones de instalaci n de la estufa para el tama o de la abertura Ver la etiqueta de la parte superior del horno para modelos aprobados Ubicaci n de la caja de conexiones de 240V 208V la caja de conexiones puede hallarse en un gabinete adyacente 25 63 5 cm Pueden resultar necesarios rellenos superiores y o laterales si la
2. 561 3344 o visite www GEAppliances ca Nota al consumidor Conserve estas instrucciones para referencia futura Nivel de destreza La instalaci n de este aparato requiere un instalador o electricista calificados El instalador tiene la responsabilidad de efectuar una instalaci n adecuada La garant a no cubre las fallas del producto provocadas por una instalaci n incorrecta e Este producto s lo se debe usar en reas interiores ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores locales IMPORTANT Cumpla con todos los c digos y ordenanzas vigentes Nota al instalador Aseg rese de dejar estas instrucciones con el Consumidor ATENCION INSTALADOR Todos los hornos de pared el ctricos deben contar con cableado de conexi n permanente cableado directo dentro de una caja de conexiones aprobada En estos productos NO se permite la conexi n del tipo enchufe y recept culo PARA SU SEGURIDAD A ADV E RTE N C A Antes de comenzar la instalaci n desconecte la energ a del panel de servicio y bloquee los medios de desconexi n para evitar el accionamiento de la energ a de manera accidental Cuando los medios de desconexi n de servicio no pueden bloquearse coloque sobre el panel de servicio un dispositivo de advertencia bien visible como una etiqueta El horno debe instalarse bien en un gabinete que se enc
3. As 1 75 cm Me 1 75 cm Side Edges of Cutout Clearance to 50 8 cm min 21 53 3 cm min 21 53 3 cm min Adjacent Corners Drawers Walls etc When Door Is Open Overlap of Oven Top 2 5 cm min 1 2 5 cm min 1 2 5 cm min of Cutout Overlap of Oven 2 5 cm min 1 3 2 cm 1 3 2 cm Bottom of Cutout Junction Box 8 22 2 cm max 9 24 1 cm max 9 2 24 1 cm max Location side only right side only right side only Height to Bottom of 4 111 8 cm 47 119 4 cm 47 119 4 cm Junction Box Recommended 13 33 7 cm 12 30 5 cm 12 30 5 cm Cutout Location from Floor Continue to Section 3 for DWO with Pedestal Otherwise continue to Section 4 Continue to Section 3 31 10856 01 13 GE PEDESTAL RAIL INSTALLATION DOUBLE OVENS ONLY A Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side of cabinet opening Locate each rail so that front of rail is behind front cabinet opening Drill pilot holes and attach rails to runner or bottom of cabinet with provided hardware Bon DOOR REMOVAL RECOMMENDED NOTE Door removal is not a requirement for installation of the product but is an added convenience To remove the door A Open the oven door as far as it will go Hinge B Push both hinge locks down toward the door frame ae to the unlocked position This may require a flat
4. Cutout observe all dimensions and gt le 2 5 1 cm Min requirements Dimension Dimension Description 27 Single Oven 30 Single Oven Cabinet Width 27 68 6 cm 30 76 2 cm Cutout Width 25 63 5 cm min 28 72 4 cm min 25 64 1 cm max 28 72 7 cm max Cutout Height 27 70 2 cm min 27 69 2 cm min 28 71 4 cm max Overlap of Oven Over 1 2 5 cm Side Edges of Cutout Cc EA 27 s 69 4 cm max Clearance to 20 50 8 cm min Adjacent Corners Drawers Walls etc When Door Is Open gt Le 2 5 1 cm Min NOTE One cooktop may be centered over either oven in the side by side installation Dimension Dimension Description 27 Single Oven 30 Single Oven Cabinet Width 25 63 5 cm min 28 72 4 cm min 25 64 1 cm max 28 72 7 cm max Cutout Height 27 70 2 cm min 27 69 2 cm min 28 71 4 cm max 27 6 69 4 cm max Unit Overlap Top 1 2 5 cm 1 2 5 cm D Unit Overlap Bottom 1 2 5 cm 1 3 2 cm O0 E Unit Overlap Side Edges 1 2 5 cm Me 1 75 cm Junction Box Location 8 22 2 cm max 94 2 24 1 cm max right side only right side only Continue to Section 4 146 1 75 cm 53 3 cm min Overlap of Oven 1 2 5 cm min 1 2 5 cm min Top of Cutout Overlap of Oven 2 5 cm min 1 3 2 cm Bottom of Cutout Junction Box Location 8 22 2 cm max 942 24 1 cm max right side only
5. a un costado Hornos con Pared Doble de 30 nicamente INFORMACION DE DISE O INSTALACIONES DE HORNO UNICO El horno Unico puede instalarse solo en un gabinete o sobre un caj n calentador El horno nico tambi n puede instalarse debajo de un mostrador de encimera o debajo de las estufas especificadas Vea la etiqueta de la parte superior del horno para consultar los modelos aprobados INSTALACIONES DE HORNO DOBLE Puede instalarse un horno doble solo en un gabinete o sobre un caj n calentador Vea la etiqueta de la parte superior del horno para consultar los modelos aprobados IMPORTANTE Siempre consulte las instrucciones de instalaciones individuales enviadas con cada producto para requerimientos espec ficos PREPARE LA ABERTURA NOTA Si el gabinete no cuenta con un fondo s lido deben instalarse dos abrazaderas o gu as para Gu as de 2 x 4 5 cm x 10 cm o equivalentes a nivel con el fondo del recorte y niveladas con los costados de l abertura soportar el peso del horno Para hornos nicos las gu as o abrazaderas deben soportar 200 lbs 91 kgs Para hornos dobles las gu as o abrazaderas deben soportar 375 lbs 170 kgs NOTA Si marcas imperfecciones o la abertura resultaran visibles sobre el horno instalado puede ser necesario agregar cu as de madera bajo las gu as y el reborde frontal hasta cubrir las marcas o la abertura NOTA Si el gabinete no cuenta con un armaz n frontal y los lados s
6. eon blade screwdriver DO NOT LIFT THE DOOR BY THE R HANDLE Hinge Slot Place hands on both sides of the door and close the oven door to the removal position approximately 1 2 2 5 cm 5 1 cm from the closed position Hi inge Arm Lift the door up and out until the hinge arms clear the slots NOTE The oven door is very heavy Be sure you have a firm grip before lifting the oven door off the hinges Use caution once the door is removed Do not lay the door on its handle This could cause dents or scratches rf Hinge Clears Slot ELECTRICAL REQUIREMENTS A WAR N NG This appliance must be properly grounded A WAR N NG To prevent fire or shock do not use an extension cord with this appliance A WAR N N G To prevent shock remove house fuse or open circuit breaker before beginning installation A WAR N NG Improper connection of aluminum house wiring to copper leads can result in an electrical hazard or fire Use only connectors designed for joining copper to aluminum and follow the manufacturer s recommended procedure closely We recommend you have the electrical wiring and hookup of your appliance connected by a qualified electrician After installation have the electrician show you how to disconnect power from the appliance You must use a single phase 120 208 VAC or 120 240 VAC 60 Hertz electrical system If you connect to aluminum wiring properly installed connectors approved for use with alumi
7. la pared trasera seg n requisito del caj n calentador p 2 5 1 cm Ubicaci n m n recomendada de la abertura desde el piso 21 5 8 54 9 cm Maa ee ee ee wl Seg n los requisitos del caj n calentador Contin e a la Secci n 3 para conocer detalles del DWO con Pedestal De otra forma contin e a la Secci n 4 INSTALACI N DEL RIEL CON PEDESTAL HORNOS DOBLES NICAMENTE A Coloque un riel con pedestal en cada rodadura del gabinete o centrado en el lado opuesto de la parte inferior del gabinete s lido nivelado con el lateral de la abertura del gabinete Ubique cada riel de modo que la parte frontal de los mismos se encuentre detr s del lado frontal de la abertura del gabinete B Realice agujeros de prueba y adjunte los rieles a la rodadura o a la parte inferior del gabinete con el equipo provisto REMOCI N DE LA PUERTA recomendada NOTA La remoci n de la puerta no es un requerimiento de la instalaci n del producto pero es una comodidad adicional Para quitar la puerta Posici n destrabada de la bisagra A Abra la puerta del horno en su totalidad B Presione ambas trabas de la bisagra hacia abajo en direcci n del marco de la puerta hasta destrabarlas Ranura Para esto puede hacer falta un destornillador de de la bisagra lados planos NO LEVANTE LA PUERTA DE LA MANIJA Coloque las manos sobre ambos lados y cierre a puerta del horno hasta la posici n de
8. remoci n aproximadamente 1 2 2 5 cm 5 1 cm de la posici n de cierre Levante la puerta hasta que los brazos de la bisagra hayan salido de las ranuras Brazo de la bisagra NOTA La puerta del horno es muy pesada Aseg rese de tener un agarre firme antes de levantar la puerta del horno de sus bisagras Tenga cuidado una vez que haya quitado la puerta No deposite la puerta sobre la manija Esto puede provocar abolladuras o rayones La bisagra sale de la ranura REQUISITOS EL CTRICOS A ADVE RTE N C A Este aparato debe contar con una adecuada conexi n a tierra A ADVE RTEN CIA Para prevenir un incendio o descarga el ctrica no utilice un cable de extensi n con este aparato A ADVE RTE N C A Para prevenir una descarga el ctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalaci n A ADVE RTE N CIA Una conexi n inadecuada de cableado dom stico de aluminio con cables de cobre puede generar un peligro el ctrico o un incendio S lo use conectores dise ados para unir cobre con aluminio y siga al pie de la letra el procedimiento recomendado del fabricante Recomendamos que un electricista calificado conecte el cableado el ctrico de su aparato Despu s de la instalaci n solicite al electricista que le indique c mo desconectar la energ a del aparato Usted debe usar un sistema el ctrico de fase nica de 120 208 VAC o 120 240 VAC de 60 hercios Si tiene un
9. right side only CUTOUT FOR DOUBLE OVENS 2 THERMAL OVENS CUTOUT FOR INSTALLATION OVER A WARMING DRAWER NOTE If the cabinet does not have a front frame and the sides are less than 3 1 9 cm thick shim NOTE Install the oven only with specific models listed on the label located on top of the oven both sides equally to establish the cutout width NOTE Additional clearances between cutouts may be required Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height Junction Box When installing a Warming Drawer below a single or double oven a separate 120V 60 HZ properly Location grounded receptacle must be installed Refer to installation instructions packed with ea the Warming Drawer for specific installation requirements be located in adjacent cabinet Anti Tip Block Against Rear Wall Per Warming Drawer Requirement 2 5 1 cm Min Depth Description 27 Double Oven 30 Double Oven 30 Double Oven Per Warming with Pedestal without Pedestal rawer Requirement A Cabinet Width 27 68 6 cm 30 76 2 cm 30 76 2 cm Cutout Width 25 63 5 cm min 28 72 4 cm min 28 72 4 cm min 25 64 1 cm max 28 72 7 cm max 28 72 7 cm max c Cutout Height 491446 126 2 cm min 5146 131 6 cm min 50 14 127 64cm 50 127 3 cm max 5116 131 9 cm max Recommended Overlap of Oven Over 1 2 5 cm
10. the front frame of the oven cavity to the locked position E Close the oven door Hinge in Locked Position Notch of Hinge Securely Fitted Int Bottom of Hinge Slot Hinge No FINAL INSTALLATION CHECKLIST e Check to make sure the circuit breaker is closed RESET or the circuit fuses are replaced e Be sure power is in service to the building e Check that all packing material and tape have been removed Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated e Remove all items from inside the oven e Check to be sure that the mounting screws are installed and flush with the side trim see Section 10 e Check that the bottom trim is installed properly see Section 11 e Ensure that air duct opening at bottom of unit is free of obstructions e Check that oven rack guides if applicable are installed correctly and oven racks function smoothly OPERATION CHECKLIST e Turn on the power to the oven refer to your Owner s Manual Verify that the bake and broil units and all cooking functions operate properly e See your Owner s Manual for the troubleshooting list e Be sure all of the oven controls are OFF before leaving the oven Instrucciones de instalaci n Hornos de pared el ctricos empotrados de 27 y 30 Preguntas Llame al 1 800 GE CARES 1 800 432 2737 o visite GEAppliances com En Canad llame al 1 800
11. unidad se encuentra entre gabinetes existentes Aseg rese de que est n bien sujetos porque anclar n el B e horno a los gabinetes Ze eae 3 4 1 9 cm _ plataforma de soporte requerida DEBE PODER SOSTENER 200 LBS 90 kg PARA HORNOS NICOS DEBE PODER SOSTENER 375 LBS 170 kg PARA HORNOS DOBLES Instalaciones lado a lado Instale dos hornos en aberturas separadas L nea central 30 5 77 5 cm modelo 30 L nea central 27 68 58 cm modelo 27 Abertura cumpla con todas las dimensiones y requerimientos Abertura cumpla con todas las dimensiones y requerimientos gt le 2 5 1 cm M n NOTA Una estufa puede centrarse sobre cualquier horno en la instalaci n de lado a lado Las conexiones de gas y el ctricas para estufas a gas deben ubicarse en una ubicaci n adyacente accesible sobre la derecha 22 55 9 cm m n 36 91 4 cm sobre l plataforma Altura del mostrador E soporte de encimera Debe coincidir con la altura de la placa de protecci n 24 61 cm S 4 10 2 cm SF Placa de protecci n Dimensi n Descripci n de la dimensi n Horno nico de 27 Horno nico de 30 Ancho del gabinete 25 63 5 cm m n 25 64 1 cm m x Altura de la abertura 27 70 2 cm m n 28 71 4 cm m x Cc Superposici n de la 1 2 5 cm unidad en parte superior Superposici n de la 1 2 5 cm unidad en parte inferior Superposici n de
12. Installation Instructions Nn i DESIGN INFORMATION 27 amp 30 Electric Built In Wall Ovens SINGLE OVEN INSTALLATIONS The single oven may be installed in a cabinet alone or above a warming drawer The single oven may also Questions Call 1 800 GE CARES 1 800 432 2737 or visit www GEAppliances com be installed below a countertop or below specified cooktops See the label on top of the oven for approved models In Canada call 1 800 561 3344 or visit www GEAppliances ca DOUBLE OVEN INSTALLATIONS A double oven may be installed in a cabinet alone or above a warming drawer See the label on top of the oven for approved models BEFORE YOU BEGIN Note to Consumer Keep these instructions for future reference Read these instructions completely and Skill level Installation of this appliance carefully requires a qualified installer or electrician IMPORTANT Save these instructions Proper installation is the responsibility for local inspector s use of the installer IMPORTANT observe all governing Product failure due to improper installation codes and ordinances is not covered under Warranty IMPORTANT Always refer to individual installation instructions packed with each product for specific requirements PREPARE THE OPENING Note to Installer Be sure to leave these Product is for indoor use only instructions with Consumer ATTENTION INSTALLER all electric wall ovens must be hard wired direct wired into an
13. OT shorten the flexible conduit The conduit strain relief clamp must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp If the flexible conduit will not fit within the clamp do not install the oven until a clamp of the proper size is obtained The 3 power leads supplied with this appliance are suitable for connection to heavier gauge household wiring The insulation of these 3 leads is rated for temperatures much higher than the temperature rating of the household wiring The current carrying capacity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire 6 MAKE ELECTRICAL CONNECTIONS A WAR N N G Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Place oven on table or platform even with the cutout opening For a single oven the platform must support 200 Ibs 91 kg and for a double oven the platform must support 375 Ibs 170 kg Connect the flexible conduit to the electrical junction box as shown below Position the conduit in such a manner that it will lie behind the unit in a natural loop when the oven is installed You will need to purchase an appropriate strain relief clamp to complete the connection of the
14. a conexi n con cableado de aluminio deben utilizarse conectores adecuadamente instalados para utilizar con cableado de aluminio Vigente desde el 1 de enero de 1996 el C digo El ctrico Nacional requiere que las nuevas construcciones no existentes utilicen una conexi n de cuatro conductores a un horno el ctrico Cuando instale un horno el ctrico en una construcci n nueva una casa rodante un veh culo recreativo o un rea donde los c digos ocales proh ben la conexi n a tierra a trav s de un conductor neutral consulte la secci n sobre conexiones en circuito derivado de cuatro conductores Consulte a las empresas de servicio p blico sobre los c digos el ctricos que se aplican en su rea No realizar el cableado de su horno de acuerdo con los c digos vigentes puede provocar una situaci n peligrosa Si no existen c digos locales el cableado y fusibles de su horno deben cumplir con el C digo El ctrico Nacional NFPA N 70 ltima edici n disponible en National Fire Protection Association Asociaci n Nacional de Protecci n contra Incendios REQUISITOS EL CTRICOS CONT Este aparato debe recibir el voltaje y frecuencia adecuados y debe conectarse a un circuito derivado individual con adecuada conexi n a tierra protegido por un interruptor de circuitos o fusible Ver la placa de clasificaci n ubicada en el armaz n del horno para determinar la clasificaci n del producto Rating Plate Location gt La p
15. a puerta esta abierta Superposici n de la 1 2 5 cm min 1 2 5 cm min 1 2 5 cm min parte superior del horno de la abertura Superposici n de 1 2 5 cm min 1 3 2 cm 1 3 2 cm la parte inferior del horno de la abertura Ubicaci n de la caja 8 22 2 cm max 9 24 1 cm max 9 24 1 cm max de conexiones s lo lado derecho s lo lado derecho s lo lado derecho J Altura hasta la parte 44 111 8 cm 47 119 4 cm 47 119 4 cm inferior de la caja de conexiones Ubicaci n 13 33 7 cm 12 30 5 cm 12 30 5 cm recomendada de la abertura desde el piso Contin e en la secci n 3 50 8 cm min 21 53 3 cm min 21 53 3 cm min 31 10856 12 12 GE 2 D ABERTURA PARA INSTALACI N SOBRE UN CAJ N CALENTADOR NOTA Instale el horno s o con los modelos espec ficos listados en la etiqueta ubicada en la parte superior del horno NOTA Pueden necesitars del horno sobre la ubicac e espacios adicionales entre las aberturas Verifique que los soportes i n de caj n calentador no obstruyan la profundidad y altura interiores requeridas Cuando instale un caj n calentador debajo de un horno nico o doble debe instalarse un tomacorriente separado de 120V 60 HZ con adecuada conexi n a tierra Consulte las instrucciones de instalaci n enviadas con el caj n calentador para requisitos espec ficos de instalaci n Bloque anti volcaduras contra
16. approved junction box A plug and receptacle is NOT permitted on these products NOTE If the cabinet does not have a solid bottom two 4 ka em x 10 cl i braces or runners must be installed to support the weight e a of the oven For single ovens the runners and braces and Flush with Sides of Cutout must support 200 Ibs 91 kg For double ovens the runners and braces must support 375 lbs 170 kg NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered FOR YOUR SAFETY AWAR N N G Before beginning the installation switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure Weight on the oven door could cause the oven to tip and result in injury Never allow anyone to climb sit stand or hang on the oven door Make sure the wall coverings counters and cabinets around the oven can withstand the heat up to 200 F 93 3 C generated by the oven NOTE If the cabinet does not have a front frame and the sides are less than 34 1 9 cm thick shim both sides equally to establish the cutou
17. conduit to the junction box Junction Box Conduit li Strain Relief Clamp not included Must Be Place Oven on a Used at Junction Box Support to Assist in Connecting Conduit U Ovens come equipped with a 40 long conduit If a longer conduit is desired there may be one available for your model To check availability or order parts call 1 800 GE CARES THREE CONDUCTOR BRANCH CIRCUIT CONNECTION NOTE If residence leads are aluminum conductors see WARNING a in Section 5 Electrical Requirements i When connecting to a three conductor branch circuit if local codes permit A Connect the bare oven ground conductor with the crimped neutral white lead to the branch circuit neutral white or gray in color using a wire nut oe Ground B Connect the oven red lead to the branch circuit red lead and Neutral and the oven black lead to the branch circuit black lead i Wires in accordance with local codes using wire nuts Junction Box C Install junction box cover Cover FOUR CONDUCTOR BRANCH CIRCUIT CONNECTION NOTE If residence leads are aluminum conductors see WARNING in Section 5 Electrical Requirements A Cut the neutral white lead from the crimp Re strip the neutral white lead to expose the proper length of conductor B Attach the appliance grounding lead green or bare copper in accordance with local codes If the residence grounding conductor is aluminum see WARNING in Section 5 C
18. el on Top of Oven for Approved Models 240V 208V Junction Box Location junction box may be in adjacent cabinet 25 63 5 cm Gas and Electrical Connections for Gas Cooktop Must be Located in an Adjacent Accessible be located Location to the Right in adjacent cabinet Opening n Between Inside 22 55 9 Walls Must be cm Min e at Least 28 1 2 Bottom o it Unit Is Positioned i etween Existing Mes mide Box Cabinets Be Sure cnay Are o ecurely Since They 22 55 9 Min i Will Anchor the Oven Above Suet 36 91 4 cm jatform i i Counterto Cutout Depth inthe Cabinet i Height P 23 1 2 aia dl Must Match 59 7 cm Min Z Require Toekick Height Top and or Side Fillers May Be Necessary Recommended Note Allow Cutout Location cy j from Floor ae 1 4 0 64 cm 32 1 2 82 6 cm pe 24 61cm clearances from side MUST SUPPORT 200 Ibs 90 kg FOR SINGLE OVENS y MUST SUPPORT 375 lbs 170 kg FOR DOUBLE OVENS edges of oven 4 10 2 cm door Toekick Side by Side Installations Side by Side Installations Install two ovens in separate cutouts Install two ovens in separate cutouts Center Line Center Line 1 30 5 77 5cm 1 30 models 1 1 27 68 58cm l 27 models H Center Line Center Line 30 5 77 5 cm 30 models Cutout Cutout observe all observe all dimensions and dimensions and requirements requirements Cutout observe all dimensions and requirements
19. he cabinet is particle board you must use es se Bea f 8 x Y particle board screws These may nimum o Locations d be purchased at any hardware store hole locations 00 A Drill through the mounting holes top and bottom may vary Front of of the side trim for the 8 mounting screws 4 the Cutout provided B Secure the oven cabinet with the screws provided OVEN RACK GUIDE INSTALLATION IF APPLICABLE A Locate included oven rack guide mouting hardware B Place oven rack guides on cavity wall studs with L bracket towards back of cavity as shown C Install guides using the 8 provided mounting nuts Oven rack guide shown in place REPLACING THE OVEN DOOR NOTE The oven door is heavy You may need help lifting the door high enough to slide it into the hinge slots Do not lift the door by the handle A Lift the oven door by grasping each side B With the door at the same angle as the removal position approximately 1 2 2 5 cm 5 1 cm from the closed position seat the notch of the hinge arm into the bottom edge of the hinge slot The notch of the hinge arm must be fully seated into the bottom of the slot C Fully open the door If the door will not fully open the indentation is not seated correctly in the bottom edge of the slot D Push the hinge locks up against
20. icado debajo de la brida de la parte inferior del conducto de aire Instalaciones SWO y DWO sin pedestal DWO sin pedestales GU A DE INSTALACI N DE LA ESTANTER A DEL HORNO SI CORRESPONDE A Ubique el equipo de montaje de la gu a del horno incluida B Posicione el conducto de modo tal que se apoye detr s de la unidad en un c rculo natural cuando el horno sea instalado C Instale las gu as usando las 8 tuercas de montaje provistas Imagen de la gu a de la estanter a en su lugar correspondiente C MO VOLVER A COLOCAR LA PUERTA DEL HORNO NOTA La puerta del horno es pesada Puede necesitar ayuda para levantar la puerta lo suficiente como para deslizarla dentro de las ranuras de la bisagra No levante la puerta de la manija A Levante la puerta del horno tom ndola de ambos lados B Con la puerta en el mismo ngulo de la posici n de remoci n aproximadamente 1 2 2 5 cm 5 1 cm desde la posici n de cerrado introduzca la muesca del brazo de la bisagra dentro del extremo inferior de la ranura de la bisagra La ranura del brazo de la bisagra debe estar bien colocada en la parte inferior de la ranura C Abra la puerta por completo Si la puerta no se abre por completo la muesca no est bien colocada en el extremo inferior de la ranura D Presione las trabas de la bisagra hacia arriba contra el armaz n fronta
21. itivo de advertencia bien visible como una etiqueta Coloque el horno sobre una mesa o plataforma en forma nivelada con la abertura Para un horno nico la plataforma debe soportar 200 Ibs 91 kg para un horno doble la plataforma debe soportar 375 Ibs 170 kg Conecte el conducto flexible a la caja de conexiones el ctrica como se indica abajo Posicione el conducto de modo tal que se apoye detr s de la unidad en un c rculo natural cuando el horno sea instalado Tendr que comprar una abrazadera para alivio de tensi n apropiada para completar la conexi n del conducto a la caja de conexiones Caja de conexiones Blanco La abrazadera del alivio de tensi n no incluido debe usarse en la caja de conexiones Coloque el horno en un soporte para ayudar a la conexi n del conducto Y Los hornos vienen equipados con un conducto de 40 de longitud Si desea un conducto m s largo puede haber uno disponible para su modelo Para verificar la disponibilidad o solicitar piezas llame al 1 800 GE CARES CONEXI N DE CIRCUITO DERIVADO DE TRES CONDUCTORES NOTA Si los cables dom sticos son conductores de aluminio ver la ADVERTENCIA de la secci n 5 Requisitos el ctricos Cuando conecte un circuito derivado de tres conductores si lo permiten los c digos locales A Conecte el conductor a tierra del horno con el cable neutral blanco en rizo al neutral del circuito derivado blanco o gris utilizando un
22. l de la cavidad del horno hasta alcanzar la posici n de trabado E Cierre la puerta del horno Brazo Lado inferior de la bisagra de la ranura Bisagra en la posici n de trabado Ranura de la bisagra bien colocada en la parte inferior de la ranura de la bisagra Ranura de la bisagra LISTA DE CONTROL FINAL DE LA INSTALACI N e Verifique que el interruptor de circuitos se encuentre cerrado RESET o que los fusibles del circuito se hayan reemplazado e Aseg rese de que haya suministro el ctrico en el edificio e Controle que se haya quitado todo el material de empaque y la cinta adhesiva No quitar estos materiales puede provocar da os al electrodom stico una vez que el aparato se haya encendido y las superficies se hayan calentado e Quite todos los elementos ubicados dentro del horno e Aseg rese de que los tornillos de montaje se encuentren instalados y nivelados con el reborde lateral ver secci n 10 e Verifique que el reborde inferior est bien instalado ver secci n 11 e Aseg rese de que la abertura inferior del conducto de aire de la unidad est libre de obstrucciones e Controle que las gu as de los estantes del horno si corresponde est n instaladas de forma correcta y que los estantes del horno funcionen de forma fluida LISTA DE CONTROL DE FUNCIONAMIENTO e Accione la energ a del horno consulte el Manual del propietario Verifique que las unidades de horneado y asado y que toda
23. la 1 2 5 cm unidad en costados laterales 8 22 2 cm m x s lo lado derecho F Ubicaci n de la caja de conexiones Contin e en la secci n 4 28 72 4 cm m n 28 72 7 cm m x 27 69 2 cm m n 27 69 4 cm m x 1 2 5 cm 1 3 2 cm 146 1 75 cm 9 24 1 cm m x s lo lado derecho ABERTURA PARA HORNOS DOBLES 2 HORNOS T RMICOS NOTA Si el gabinete no cuenta con un armaz n frontal y los lados son menores a un grosor de 3 4 1 9 cm coloque cu as uniformemente sobre ambos lados para establecer al ancho de la abertura Ubicaci n de la caja de conexiones la caja de conexiones puede hallarse en un gabinete adyacente SS SSO RT Profundidad de la abertura 23 1 2 59 7 cm m nimo Horno doble de 30 sin pedestal Descripci n Horno doble de 27 Horno doble de 30 con pedestal Ancho del gabinete 27 68 6 cm 30 76 2 cm 30 76 2 cm Ancho de la abertura 25 63 5 cm min 284 72 4 cm min 25 64 1 cm max 28 72 7 cm max A Itura de la abertura 4916 126 2 cm min 511346 131 6 cm min 50 127 3 cm max 511 s 131 9 cm max 1 2 5 cm 1 6 1 75 cm 28 72 4 cm min 28 72 7 cm max 50 127 64cm Recomendada Superposici n del 1 6 1 75 cm horno sobre los costados laterales de la abertura Espacio respecto de esquinas adyacentes cajones paredes etc cuando l
24. laca de clasificaci n se encuentra en el reborde lateral del horno Utilice la tabla de abajo para determinar la protecci n de circuito dedicado m nima recomendada Tama o de circuito de KW Clasificaci n de KW recomendado 240V 208V dedicado lt 4 8 KW lt 4 1 KW 4 9 KW 7 2 KW 4 2 KW 6 2 KW Clasificaci n 7 3 KW 9 6 KW 6 3 KW 8 3 KW 40 Amp 9 7 KW 12 0 KW 8 4 KW 10 4 KW 50 Amp NO acorte el conducto flexible La abrazadera del alivio de tensi n del conducto debe estar bien sujeta a la caja de conexiones y el conducto flexible debe estar bien sujeto a la abrazadera Si el conducto flexible no entra dentro de la abrazadera no instale el horno hasta obtener una abrazadera del tama o adecuado Los 3 cables de energ a suministrados con este aparato son adecuados para conexiones con cableados dom sticos de calibre mayores La aislaci n de estos 3 cables est clasificada a temperaturas mucho m s elevadas que la clasificaci n del cableado dom stico La capacidad de transmitir corriente del conductor est determinada por el calibre del cable y la clasificaci n de temperatura de la aislaci n alrededor del cable 6 REALICE LAS CONEXIONES EL CTRICAS A ADVE RTEN CIA Desconecte la energia del panel de servicio y bloquee los medios de desconexi n para evitar el accionamiento de la energ a de manera accidental Cuando los medios de desconexi n de servicio no pueden bloquearse coloque sobre el panel de servicio un dispos
25. num wiring must be used Effective January 1 1996 the National Electrical Code requires that new construction not existing utilize a four conductor connection to an electric oven When installing an electric oven in new construction a mobile home recreational vehicle or an area where local codes prohibit grounding through the neutral conductor refer to the section on four conductor branch circuit connections Check with your local utilities for electrical codes which apply in your area Failure to wire your oven according to governing codes could result in a hazardous condition If there are no local codes your oven must be wired and fused to meet the National Electrical Code NFPA No 70 latest edition available from the National Fire Protection Association ELECTRICAL REQUIREMENTS CONT This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse See the rating plate located on the oven frame to determine the rating of the product Rating Plate Location Rating plate is located on the oven side trim Use the chart below to determine the minimum recommended dedicated circuit protection Recommended KW Rating KW Rating Circuit Size 240V 208V Dedicated lt 4 8 KW lt 41 KW 4 9 KW 7 2 KW 4 2 KW 6 2 KW 7 3 KW 9 6 KW 6 3 KW 8 3 KW 40 Amp 9 7 KW 12 0 KW 8 4 KW 10 4 KW 50 Amp DO N
26. on menores a un grosor de 3 4 1 9 cm coloque cu as uniformemente sobre ambos lados para establecer al ancho de la abertura Abrazaderas adecuadas para sostener las gu as ABERTURA PARA HORNOS NICOS EN UN GABIENTE DE PARED NOTA Si el gabinete no cuenta con un armaz n frontal y los lados son menores a un grosor de 3 4 1 9 cm coloque cu as uniformemente sobre ambos lados para establecer al ancho de la abertura Estos hornos no est n aprobados para instalaciones apilables p La abertura entre las paredes nternas debe ser de por lo menos 28 1 2 72 4 cm Ubicanci n de la caja de conexiones la caja de conexiones puede hallarse en un gabinete adyancente 22 55 9 cm m n hasta la parte inferior de la caja de Instale dos hornos en aberturas separadas conexiones Profundidad de la abertura 23 1 2 59 7 cm m nimo Nota Deje 1 4 0 64 cm de espacio desde los extremos laterales de la puerta del horno Instalaciones lado a lado L nea central L nea central 1 30 5 77 5 cm I H modelo 30 H 1 1 27 68 58 cm I i modelo 27 Abertura cumpla Abertura cumpla con todas las con todas las c l dimensiones y dimensiones y requerimientos requerimientos 2 5 1 cm m n Ubicanci n recomendada de la abertura desde el piso 32 1 2 82 6 cm Descripcion de la dimension Horno Unico de 27 Horno nico de 30 Ancho del gabinete 27
27. onnect the oven neutral white lead to the branch circuit neutral white or gray in accordance with local codes using a wire nut Connect the oven red lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes using wire nuts NOTE If the residence red black or white leads are aluminum conductors see WARNING in Section 5 Junction Box E Install junction box cover Cover 9 SLIDE OVEN INTO OPENING e Lift oven into cabinet cutout using the oven opening as a grip Carefully push against oven front frame Do not push against outside edges NANI ST OOO NANI E E E E E E E N E E E E E E E E E E E E E E N E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E N E Es E E E i Ne LLL MOUNT THE OVEN BOTTOM TRIM INSTALLATION A WAR N NG e With oven installed attach the bottom trim through its mounting holes in front vertical brace using p e Mounting screws must U two trim screws provided Bottom trim lip must be placed under flange of bottom air duct be used Failure to do so could result in the oven falling out of the cabinet causing serious injury SWO s and DWO installations without pedestal NOTE Before drilling the pilot holes make sure the oven is pushed as far back into the opening as it will go and is centered The Screws ee Mounti NOTE If t
28. orno dentro de la abertura del gabinete utilizando el horno abierto como agarre Con cuidado empuje contra el armaz n frontal del horno No presione sobre los bordes externos ANI gt SS OIgO0O gt go gt g gt OOgggogo gt o OOSgOgOggO Ogg OOOO OOOO 7 0000 aa INSTALE EL HORNO A ADVERTENCIA Deben utilizarse tornillos de montaje Si no lo hace el horno puede caer del gabinete lo que provocar a una lesi n grave NOTA Antes de perforar los orificios piloto aseg rese de que el horno se encuentre en la posici n final de la abertura y centrado NOTA Si el gabinete es de placa de part culas deben utilizarse tornillos 8 x para dicho material stos pueden adquirirse en cualquier ferreter a A Perfore a trav s de los orificios de montaje superiores e inferiores del reborde lateral para los tornillos de montaje 8 provistos B Asegure el gabinete del horno con los tornillos provistos JJ de los orificios de montaje las ubicaciones pueden variar q Ubicaciones M Los tornillos deben hallarse a un m nimo de Ya 6 mm desde el frente de la abertura INSTALACION DEL REBORDE INFERIOR e Una vez instalado el horno adjunte el borde inferior a trav s de sus agujeros de montaje frente al soporte vertical utilizando los dos tornillos con cabeza recortada provistos El labio de la cubierta inferior deber ser ub
29. s las funciones de cocci n operen bien e Ver el Manual del propietario para la lista de detecci n y soluci n de problemas e Aseg rese de que todos los controles del horno se encuentren en OFF apagado antes de dejar el horno
30. t width MATERIALS YOU MAY NEED TOOLS YOU MAY NEED Junction Box 1 8 Drill Bit and Electric or Hand Drill Wire Nuts Phillips Screwdriver Strain Relief Clamp for 1 2 Conduit Wire Strippers REMOVE PACKAGING MATERIALS Failure to remove packaging materials could result in damage to the appliance Remove all packing parts from oven racks and heating elements Remove protective film and labels on the outer door and control panel Also remove plastic on trims and panel all tape around the oven and any shipping screws securing the oven to the base pad Open oven door and remove literature pack and oven racks Remove the bottom trim from the top of the oven It will be installed at the end of the installation process The trim is wrapped separately and taped to the top of the unit Remove pedestal rails from seperate box and set aside 30 Double Wall Ovens Only CUTOUT FOR SINGLE OVENS IN WALL CABINET NOTE If the cabinet does not have a front frame and the sides are less than 34 1 9 cm thick shim both sides equally to establish the cutout width CUTOUT FOR SINGLE OVENS UNDER COUNTER NOTE These ovens are only approved to be installed under the specific models as labeled on the unit These ovens are not approved for stackable installations Junction Box Location junction box may Gas or Electric Cooktops May Be Installed Over This Oven See Cooktop Installation Instructions for Cutout Size See Lab
31. tap n de alambre Cables a B Conecte el cable rojo del horno al cable rojo del circuito derivado y el yy tierra y cable negro del horno al cable negro del circuito derivado de acuerdo neutrales con los c digos locales utilizando tapones de alambre Tapa de C Instale la tapa de la caja de conexiones la caja de conexiones CONEXI N DE CIRCUITO DERIVADO DE CUATRO CONDUCTORES NOTA Si los cables dom sticos son conductores de aluminio ver la ADVERTENCIA de la secci n 5 Requisitos el ctricos A Corte el cable neutral blanco del conector de engarce Pele el cable neutral blanco para exponer la longitud correcta del conductor E Cable a B Conecte el cable a tierra del artefacto verde o cobre tierra de acuerdo con los c digos locales Si el conductor a tierra de la residencia es de aluminio ver ADVERTENCIA de la secci n 5 C Conecte el cable neutral blanco del horno con el neutral de circuito derivado blanco o gris de acuerdo con c digos locales utilizando un tap n de alambre D Conecte el cable rojo del horno al cable rojo del circuito derivado y el cable negro del horno al cable negro del circuito derivado de la caja de acuerdo con los c digos locales utilizando tapones de alambre conexiones NOTA Si los cables rojos negros o blancos son conductores de aluminio ver ADVERTENCIA de la secci n 5 E IInstale la tapa de la caja de conexiones 9 DESLICE EL HORNO DENTRO DE LA ABERTURA e Levante el h
32. uentre firmemente sujeto a la estructura de la casa Si se coloca peso sobre la puerta del horno ste puede volcarse y provocar lesiones Nunca permita que nadie se suba siente pare o cuelgue de la puerta del horno Verifique que el revestimiento de las paredes mostradores y gabinetes ubicados alrededor del horno puedan soportar el calor hasta 200 F 93 3 C generado por el horno HERRAMIENTAS NECESARIAS Broca de perforadora de 1 8 y perforadora el ctrica o de mano Destornillador de estrella Alicates pelacables MATERIALES QUE PUEDE NECESITAR Caja de conexiones Tapones de alambre Abrazadera de alivio de tensi n para conducto de 1 2 QUITE LOS MATERIALES DE EMPAQUE No quitar los materiales de empaque puede provocar da os al electrodom stico Quite todas las partes de empaque del horno bandejas y elementos de calentamiento Quite la pel cula protectora y las etiquetas de la puerta exterior y panel de control Tambi n quite los elementos pl sticos de los rebordes y panel toda la cinta que cubre el horno y los tornillos de env o que fijan el horno a la almohadilla base Abra la puerta del horno y quite el material informativo y las bandejas del horno Quite el reborde inferior de la parte superior del horno Se colocar al final del proceso de instalaci n El reborde se encuentra envuelto en forma separada y adherido en la parte superior de la unidad Retire los rieles del pedestal de la caja que est aparte y d jelos