Home
        Sharp SMD3070AS Installation Guide
         Contents
1.   be sure that the screws do not penetrate electrical  wiring or plumbing        Anti Tip  block             Figure 8    ELECTRICAL OUTLET    The electrical requirements are a 120 volt 60 Hz  AC only  15 amp  or more protected  electrical supply  It is recommended that a separate circuit serving only this appliance  be provided     The drawer is equipped with a 3 prong grounding plug  It must be plugged into a wall  receptacle that is properly installed and grounded  Should you only have a 2 prong  outlet  have a qualified electrician install a correct wall receptacle     Note  If you have any questions about the grounding or electrical instructions  consult  a qualified electrician or service person       Can also be installed using an electrical outlet in an adjacent cabinet within the area where  the provided electrical cord can reach     Always check electrical codes for requirements     Suggested electrical  outlet location        Figure 9    GROUNDING INSTRUCTIONS    This appliance must be grounded  The Microwave Drawer is equipped with a cord  having a grounding wire with a grounding plug  It must be plugged into a wall receptacle  that is properly installed and grounded in accordance with the National Electrical Code  and local codes and ordinances  In the event of an electrical short circuit  grounding  reduces risk of electric shock by providing an escape wire for the electric current     NGI E Improper use of the grounding plug can result in a risk of electric    s
2.  30  cabinet minimum  P  15 9 16  opening                         Figure 5 a a    21 5 8    4 11 16    1 3 4    21 7 8    29 7 8    15 7 8      14 19 32      1 9 64  door thickness  15  auto drawer opening  4                 ce rot on o gt              Figure 6          This drawing represents a typical standard cabinet  If installed in custom  cabinets with extended counter tops  take into account visibility and access  to controls  See Figure 7                                                                             A Move oven location downward for  extended countertops  B    lt a Extended countertops l        11  lt   E  C Figure 7  D y  G  A  25   B  1 2   C  15 7 8   D  36   E  Control panel shown in open position  F  24     G  34 1 2   F             ANTI TIP BLOGK    NORMAL INSTALLATION STEPS  ANTI TIP BLOCK INSTALLATION INSTRUCTIONS    To reduce the risk of tipping of the drawer  the Anti Tip block must be properly installed  located 14 1 3 16 inches above the floor on which the Microwave Drawer will sit  The  6 inch Anti Tip block must be provided by the installer  See Figures 1  4 and 5  The  Anti Tip block prevents serious injury that might result from spilled hot liquids     If the Microwave Drawer is ever moved to a different location  the Anti Tip block must  also be moved and installed  When installed to the wall  make sure that the screws  completely penetrate the dry wall and are secured in wood or metal so that the block  is totally stable  When fastening
3. S AND DIMENSIONS    e Dimensions that are shown in Figure 1  for 24   or Figures    4 and 5  for 30   must be used  Given dimensions provide  minimum clearance  Locate electrical outlet in the shaded  area in the upper left hand corner of the cutout  See Figure 9     Contact surface must be solid and level  Pay special attention  to the floor on which the Microwave Drawer will sit  The  floor of the opening should be constructed of plywood strong    Your oven can be built into a cabinet or wall by itself or  under a gas or electric wall oven     Be sure that the clearance of the floor between the wall oven  and the microwave drawer is a minimum of 2 inches     The microwave interior will easily accommodate a 9  x 13   oblong dish or a bag of microwave popcorn     The oven can also be mounted flush  Please see instructions    enough to support the weight of the oven  about 100 pounds   OGG     for flush mounting included with the Flush Mount Deflector    e Check location where the Microwave Drawer will be v  nt     installed for proper electrical supply     24  MICROWAVE DRAWER MEASUREMENTS                                              ee   ae  a E          Figure 2                                        ay  one a             A  21 5 8  F  15 7 8   B  4 11 16  G  14 19 32   Cutout Dimension 22 1 8  x 15 9 16    CIs E  D  21 7 8  I  15  auto drawer opening  6  E  23 7 8  J  4     Suggested electrical outlet location     Anti Tip block  a Figures 1 and 2 contain many Microwave Dr
4. SHARP     Microwave Drawer   SMD2470AS  SMD3070AS  INSTALLATION MANUAL    SPECIAL WARNING    INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER   IMPORTANT  SAVE this installation manual FOR LOCAL ELECTRICAL INSPECTOR   S USE   READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE     CLEARANCES AND DIMENSIONS    For SAFETY CONSIDERATIONS do not install drawer in any combustible cabinetry  which is not in accord with the stated  clearances and dimensions on pages 2   5  See Figure 1  for 24   or Figures 4 and 5  for 30       UNPACKING YOUR MICROWAVE DRAWER    e Remove all packing Sealing   materials from inside surface   the Microwave Drawer   DO NOT REMOVE  THE WAVEGUIDE  COVER  which is  located on the top    of the Microwave    Waveguide    Drawer   _ Sealing  e Remove the feature surface  sticker  if there is one   Check the drawer for ale oe Oven  cavity    any damage  such as  misaligned or bent  drawer  damaged drawer seals and sealing surfaces  broken  or loose Microwave Drawer guides and dents inside the cavity  or on the front side of the drawer  If there is any damage  do  not operate the Microwave Drawer and contact your dealer or  a SHARP AUTHORIZED SERVICER     IMPORTANT NOTES TO THE INSTALLER    e Read all of the Installation Manual before installing the  Microwave Drawer     e Remove all packing material before connecting the electrical  supply   e Observe all governing codes and ordinances     e Be sure to leave these instructions with the co
5. awer measurements  r a for reference when planning the drawer   s location     This Microwave Drawer can be installed below any electric or      22 1 8  opening gas wall oven      14 13 16  to bottom of Anti Tip block    Allow 7 8  overlap   Canalso be installed using an electrical outlet in an adjacent cabinet  within the area where the provided electrical cord can reach  Power  cord access hole in cabinet should be a minimum 1 1 2  diameter    hole and deburred of all sharp edges     LU Always allow sufficient power cord length to the  electrical outlet to prevent tension     23 1 2  minimum depth     Allow 3 16  overlap     36  countertop height     Allow 7 16  minimum overlap    Floor must support 100 Ib    24  cabinet minimum Always check electrical codes for requirements     NOZZrPASHMTAMmmMoOaA gt     15 9 16  opening    This drawing represents a typical standard cabinet  If installed in custom  cabinets with extended counter tops  take into account visibility and access  to controls  See Figure 3                                                                                   A Move oven location downward for  extended countertops  B a Extended countertops i     P      E    C Figure 3  D G  A  25   B  1 2   C  15 7 8   D  36   E  Control panel shown in open position  F  24   G  34 1 2   n y  F                   30  MICROWAVE DRAWER MEASUREMENTS    Figures 4  5 and 6 contain many Microwave Drawer measurements   Can also be installed using an electrical outlet in an ad
6. hock  Do not use an extension cord  If the power supply cord is too short  have a  qualified electrician or serviceman install an outlet near the appliance     Permanent and Correct Installation    3 Prong plug    i  a        Sar   A  Grounding pin    3 Prong receptacle       Grounded receptacle box    DRAWER INSTALLATION    1  Place the drawer adjacent to the wall or cabinet opening   Plug the power supply cord into the electrical outlet     2  Carefully guide the drawer into the prepared opening   Avoid pinching the cord between the oven and the wall     Parts supplied       3  Slide the drawer all the way until the mounting flange is          flush with the face of the cabinet  See Figure 10A  g    4 Screws    4  Open the drawer  Using the 4 holes on the drawer as a Figure 10B    template  pre drill the cabinet using a 1 16  bit  See Figure  10A     5  Secure the drawer with the 4 screws supplied  See Figure Figure 10A  10B     MODEL AND SERIAL NUMBER LOCATION    The name plate includes model and serial number  Open the Microwave Drawer fully  The label is beyond the back wall of the microwave  cavity facing up from the flat surface     CARE  CLEANING AND MAINTENANCE    Refer to the Operation Manual for cleaning instructions     BEFORE YOU CALL FOR SERVICE    Read the BEFORE YOU CALL and operating instruction sections in your Operation Manual  It may save you time and expense  The  list includes common occurrences that are not the result of defective workmanship or materia
7. jacent    for reference when planning the drawer   s location  cabinet within the area where the provided electrical cord can    i i   reach  Power cord access hole in cabinet should be a minimum  This Microwave Drawer can be installed below any electric or    il 1 1 2  diameter hole and deburred of all sharp edges   gas wall oven     ee Always allow sufficient power cord length to the  electrical outlet to prevent tension     Always check electrical codes for requirements                                                           Cutout Dimension 28 7 16  x 15 9 16              A  84  wall cabinet  B  Optional wall oven cutout illustrated in sketch       C  Suggested electrical outlet location   D  6    E  Anti Tip block   F  3 1 2    G  5    H  4    I  2  minimum   J  28 7 16  opening   K  Allow 3 16  overlap   L  14 13 16  to bottom of Anti Tip block  M  Allow 3 4  overlap   N  23 1 2  minimum depth   O  15 9 16  opening   P  Allow 7 16  overlap   Q  Floor must support 100 Ib                                  R  30  cabinet minimum                      es    R    ia Te  Figure 4             Cutout Dimension 28 7 16  x 15 9 16          6      Suggested electrical outlet location      Anti Tip block   5    3 1 2    4      28 7 16  opening     14 13 16  to bottom of Anti Tip block  Allow 3 4  overlap             23 1 2  minimum depth     Allow 3 16  overlap     36  countertop height   M  Allow 7 16  overlap   N  Floor must support 100 Ib    rAT TI TaADMmMOA Dp                O 
8. ls in this range             Mounting  flange       Refer to the warranty in your Operation Manual for Sharp   s toll free service number and address  Please call or write if you have inquiries  about your microwave product and or need to order parts     SHARP SHARP ELECTRONICS CORPORATION     1 Sharp Plaza  Suite 1 e Mahwah  New Jersey 07495 1123  1 800 BE SHARP  237 4277     TINSEB539MRRO FEB 10  2015  8    
9. nsumer            IMPORTANT NOTES TO THE CONSUMER    Keep this manual with your Operation Manual for future  reference     e As when using any microwave oven generating heat  there  are certain safety precautions you should follow  These are  listed in the Operation Manual  Read all and follow carefully     e Be sure your Microwave Drawer is installed and grounded  properly by a qualified installer or service technician     IMPORTANT SAFETY INSTRUCTIONS    NENIT if the information in this manual is not followed  exactly  a fire or electrical shock may result that could cause  property damage  personal injury or death     NNN  To reduce the risk of tipping  the Microwave    Drawer must be secured by a properly installed Anti Tip  block     e This Microwave Drawer must be electrically grounded in  accordance with local codes    e Make sure the wall coverings and the cabinets around the  Microwave Drawer can withstand the heat generated by the  Microwave Drawer     NONIM Never leave children alone or unattended in  the area where a Microwave Drawer is in use  Never leave the  drawer open when the microwave is unattended     AAWARNING Stepping  leaning or sitting on the drawer may  result in serious injuries and can also cause damage to the    Microwave Drawer     e Do not use the Microwave Drawer as a storage space   This creates a potentially hazardous situation     e Check that the time of day is in the display  If not  touch  STOP CLEAR to prevent unintended use     CLEARANCE
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
TP-Link C7 Quick Installation Guide  OneRemote User guide English  Extron electronic Extron Electronics Projector Accessories PMK 150 User's Manual  retrouvez le cours n°3 des Cristaux Ethérique en suivant ce lien  Sony BKPF-L752 User's Manual  O2 ISM Qualification Kit Instruction manual Bedienungsanleitung  Le matériel suivant est nécessaire pour la communication de la  intext:Betriebsanleitung filetype:pdf  Fiche Technique gélatine granulé 200 bloom  WiRELESS SPEAkER - Acoustic Research    Copyright © All rights reserved. 