Home

American Standard 3060.100.CRW Installation Guide

image

Contents

1. ra A 1 2 Drain Hole B Sc 8 Bo F 7 77 7 4 Dry Wall Galvanized Nail Galvanized Nail Dry Wall Tile Tile Wall Stud Wall Stud Silicone Silicone Tub Tub Integral Flange Non Integral Flange Model B C D E F G Flange Detail X2848 11X 48 28 1 2 37 1 2 10174 14 1 4 15 n a No Integral Flange X2651 11X 50 1 2 26 1 2 38 10 12 11 3 4 16 1 4 na No Integral Flange X3051 11X 50 1 4 30 37 1 2 10174 14 1 2 16 1 4 n a No Integral Flange X3260 21X 59 142 32 1 2 37 1 2 103 4 15 20 3 4 No Integral Flange Tubs installed an alcove installation require a raised flange to prevent water from seeping past the tub and into the wall 1 Tubs without a raised flange should be installed with tile flange kit model TFK 60 The flange kit is a long plastic strip that fits onto the rim of the tub to provide the leak protection needed The tile flange should be installed on the tub before it is placed in the alcove Install the tile flange along all sides of the tub where the wall will be Measure to fit and miter cut the flange corners The flange should be attached to the tub with a construction adhesive Once the tub is in place to be installed and flange kit mounted fasten the flange to studs using galvanized fasteners Warnin
2. Never allow the weight of the tub to be supported by wood support stringers and do not use integral tile flange if equipped to screw or nail in place as this will result in product failure and will void the warranty 6 Verify the product is completely level by checking tub deck surface and ensure all leveling feet are touching the ground 7 Electrical connection is made by simply plugging each cord into the GFCI outlet 8 After plumbing and electrical connections have been made the tub and door seal should be cleaned of dirt and debris Use warm water and a non abrasive cleaner for clean up 9 Installation is not complete until the bathtub has been water tested in place and does not leak martea Standard OWNERS MANUAL FAUCET INSTALLATION IMPORTANT IS RECOMMENDED THAT AMERICAN STANDARD FAUCETS ARE USED FOR THE WALK IN BATHTUBS IF ANOTHER FAUCET TYPE IS USED IS VITAL THAT THE FAUCET VALVES UNDER THE TUB DECK DO NOT INTERFERE WITH THE DRAIN OVERFLOW LOCATED AT THE CENTER OF THE TUB DO NOT DRILL HOLES IN THE CENTER OF THE TUB DECK TUB DECK IT IS IMPORTANT TO TAKE INTO CONSIDERATION THE THICKNESS OF TILE SHEETROCK OR OTHER WALL SURROUNDS BEFORE DRILLING AS THEY MAY INTERFERE WITH HAND CLEARANCES DO NOT DRILL IN SHADED AREA PLEASE REFER TO FAUCET INSTALLATION INSTRUCTIONS INCLUDED WITH AMERICAN STANDARD FAUCET SETS 10 Arican Standard OWNERS MANUAL FAUCET INSTALL
3. Tee Strainer N sro Elbow Drain Tee EEE penne a Drain Shoe Drain Drain DSSS Ss Cable ea j j P Trap N at We have taken reasonable precautions to ensure the Quick Drain is suitable for residential plumbing Itis the responsibility of the installer to insure the sanitary system is acceptable for the use of the Quick Drain We do not accept responsibility for damage arising from the use of the Quick Drain 18 Amaria Standard OWNERS MANUAL Threshold Drain Installation Threshold Drain Information All gel coat walk in bathtubs are provided with a threshold door drain All acrylic walk in bathtubs feature the Patented 5 Door System which does not require the threshold drain Connection of the Door Drain Subfloor Door Drain requires the connection to a minimum 1 sanitary drain line Use UPC Approved PVC Glue Primer and Schedule 40 1 4 pipe The door drain check valve and 3 8 vinyl tubing are installed on the walk in bathtub The door drain coupling has an integral 3 8 barb for connection of the door drain line The drain coupling must be located between the drain tee and shoe along the tub s drain line The 3 8 barb on the drain coupling must be positioned parallel to the sub floor Connect the door drain assembly and drain coupling with 3 8 vinyl tubing Verify the coupling barb check valve and 3 8 tubing are horizonta
4. and fasteners packed separately within the kit to protect the trim finish Follow the installation instructions provided with the drain overflow kit After the drain is fully installed test the unit for proper drainage If the unit does not drain properly rectify the condition before proceeding with installation American Standard is not responsible for the removal or re installation costs Note All gel coat models require additional installation of the door drain to the waste overflow Connection of the Quick Drain e Quick Drain System requires the connection to a minimum 1 4 sanitary drain line Use UPC Approved PVC Glue Primer and Schedule 40 1 pipe Do not change or modify the location and or piping of the Back Flow Manifold The sanitary tee is installed directly above the drain tee with clearance not greater than 1 Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit Glue the Quick Drain Fittings pipe and drain overflow assembly to the sanitary drainage pipe NOTE Water tight installation of the waste overflow is the installer s responsibility Drain leakage is excluded from Safety Tubs warranty of this product Over Flow Pre Installed Back Flow Manifold Supplied Not Supplied Check Valve Drain Cable Back Flow Manifold From Quick io JL Drain Pump Flow Direction T Stopper Reducer i a Saaitary
5. cleaning of the whirlpool and or air spa systems 12 Both whirlpool and air spa systems are designed so that water will drain from the plumbing after each use 13 There are no user serviceable parts located under the tub PURGE CYCLE All air blowers are equipped with a purge cycle to remove residual water from the lines The purge cycle will begin approximately 20 minutes after the unit is initially turned off Do not be alarmed when the cycle begins IN LINE HEATERS If your bathtub is equipped with an optional in line heater it will operate only when the pump is on Note the in line heater is designed to keep your water warmer longer but is not designed to increase the water temperature Heat settings are not adjustable 23 Amariei Standard OWNERS MANUAL CLEANING AND MAINTENANCE Pump and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use Below are the recommended procedures for cleaning e Do not run whirlpool dry Fill the tub with hot water 2 3 inches above the jets and add 2 3 teaspoons of low foaming detergent such as dishwashing machine detergent e Turn on whirlpool system and run for 10 minutes e Drain tub completely tub with cold water above jets e Turn on whirlpool system and run for 15 minutes e Drain tub completely Cleaning the suction cover Clean and remove any hair lint from the suction cover On a monthly basis
6. is operated by the push button switch labeled Jets or Air Both the number of buttons and their assorted functions vary Do not depress the button s repeatedly and or rapidly as all function s are controlled electronically It may take a few seconds before any change becomes perceptible Refer to massage instructions sheet for more information on the controls 3 If your American Standard walk in bath is equipped with whirlpool jets you can adjust the direction and flow rate of the jets to your liking by moving the nozzle for direction and turning the outside ring or the nozzle clockwise or counterclockwise for the flow rate Some jets are not adjustable at the jet face but can be adjusted by the Legs Only Massage valve located near the seat If equipped 4 The Legs Only Massage whirlpool amp combo systems only opens and closes the jets above the seat which allows you to fill the tub half way and operate only the lower whirlpool jets The Legs Only Massage valve must be closed when filling the tub half way and operating the whirlpool Failure to close the valve when filling the tub half way will result in water shooting out of the jets above the seat when the pump is activated If equipped 5 If your American Standard walk in bath is equipped with an Air Spa system you can activate the heated blower by pushing the push button on the deck Push the button to turn on off and cycle for the various speeds 6 If y
7. the back and adjacent wall of the alcove and 3 8 away from end of 14 Arurican Standard OWNERS MANUAL Acrylic Extension Kit Installation Steps 5 amp 6 e Remove the tub from the alcove and install the front and then top panel with the self tapping fasteners Predrill screw holes and attach front panel to aporn Predrill screw holes and attach to top deck of tub Self Tapping Screw Self Tapping Screw Steps 7 amp 8 e Apply the temporary clamps to help support the front and top panels while re locating the tub back into the alcove e Remove temporary clamps check level shim if necessary and seal in panels with silicone Apply silicone between Final Install wood stringers and Slide tub into final N extension panels installed position _ 1 gt 222 15 Standard OWNERS MANUAL Gelcoat Extension Kit Installation Gel Coat Extension Kits are designed for each unit to fit within a 60 alcove packet The top and end panels have integral flange for easy of installation Step 1 Temporary locate the tub within the alcove walls Level the tub along the deck and apron e Measure the distance from the tub and apron to the alcove wall 9 Verify the fit of both front and top extension panels Extension Kit Parts a pe Measure Distance Sheet Metal Screw Top Panel Self Tapping Screw Front Panel Ste
8. unscrew the suction cover and clean away any hair lint or debris from the cover and housing then remount the cover in place Suction covers with visible screws from inside the tub can be removed Some suctions are intended not to be removed and have no visible fasteners This style of suction cover does not need to be removed for cleaning Never operate the unit with the safety suction cover off Do not use abrasive cleaners as they will scratch and dull the surface Use a mild liquid household detergent cleaner such as Clorox Soft Scrub Plaster can be removed using a wooden stick DO NOT USE METAL SCRAPERS WIRE BRUSHES WATER BARRIER WALLBOARD OR OTHER HARSH ABRASIVE TOOLS Usually a mild detergent will remove construction debris More stubborn debris may be removed with denatured alcohol or Clorox Soft Scrub cleaner Light scratches and dulled areas may be restored to original luster by rubbing with an automotive type cleaning compound such as DuPont White Polishing Compound 24 Standard OWNERS MANUAL LIMITED WARRANTY COVERAGE American Standard Walk In Baths are warranted in accordance with the following warranty This warranty is extended to the first purchaser and does not extend to products previously used as display models or products that have been modified or repaired by anyone else but American Standard unless approved by American Standard American Standard premium acrylic walk in baths come with
9. 120 volts Use 12 Gauge 3 conductor cable for the circuits If the length run exceeds 100 feet check with local codes for requirements Install moisture proof junction box s 6 above the floor at the pump end of the framing for each circuit DO NOT INSTALL THE JUNCTION BOX S WHERE IT CAN BE REACHED WHILE SITTING OR STANDING IN THE TUB OR TOUCHING THE FAUCETS QUICK DRAIN LIGHTS WHIRLPOOL AIR SPA COMBO amp HEATER ELECTRIAL REQUIREMENTS This section lists the factory installed components of the Whirlpool and or Air Spa Systems Note the required number of circuits and their rating for the Whirlpool amp Air Spa unit you are planning to install ELECTRICAL REQUIREMENTS FOR FACTORY INSTALLED COMPONENTS Electrical Rating Electrical Rating Dedicated Systems Circuit 1 Circuit 2 Circuit Soaker w Quick Drain 15 Amp GFCI Soaker w Light 15 Amp GECI Soaker Quick Drain w Light 15 Amp GECI Whirlpool or Air Spa 15 Amp GECI Whirlpool or Air Spa w Light 15 Amp GECI Whirlpool or Air Spa w Quick Drain 15 Amp GECI 15 Amp GECI Whirlpool or Air Spa w Light amp Quick Drain 15 Amp GECI 15 Amp GECI Whirlpool Air Spa Combo 15 Amp GECI 15 Amp GFCI Whirlpool amp Air Spa Combo w Light 15 Amp GECI 15 Amp GECI Whirlpool amp Air Spa Combo w Quick Drain 20 Amp GECI 1 15 Whirlpool amp Air Spa Combo w Light amp Quick Drain 20 Amp GEC
10. ATION COLD DIVERTER RAND CONTROL CONTROL MANOLE SPOUT SHOWER HANDLE OVERFLOW CAT Oe pyrene EE Ron pas Piba LEFT HAND TUB HAND SHOWER TUB SPOUT FEA HOT CONTROL CONTROL HANOLE HANDLE OVERFLOW HAND SHOWER 49 KOLDER STERNAL STOP gt RUSSER RNG 2 p RUBBER RING ruar G TI 1 RUEBER WASHER 7 gt RUBEEA TASKER WASHER BRASS WASHER 7 gt WASHER A we LOCK KUT REPLACE WITH FLEXISLE HOSE KIT 8 EA REMOVE RIGID TUBING ASSEMBLY RIGHT HAND TUB IMPORTANT LISTED ARE EXISTING EXAMPLE SET UPS FOR AMERICAN STANDARD FAUCET SETS NOTICE NO HOLES ARE DRILLED DIRECTLY OVER THE OVERFLOW FAUCET VALVES INSTALLED UNDER THE DECK OF THE TUB REQUIRE A CERTAIN AMOUNT OF SPACE PAY ATTENTION TO CLEARANCES BOTH ABOVE AND BELOW THE TUB DECK IT IS RECOMMENDED THAT THE TUB SPOUT IS ALWAYS LOCATED ON THE WALL SIDE OF THE TUB AND NOT CLOSEST TO THE DOOR SIDE OF THE TUB THE PORTSMOUTH FAUCET LEFT SHOWS A FOUR HOLE CONFIGURATION WITH A FLEXIBLE HOSE KIT THE FLEXIBLE HOSE KIT PROVIDES MANEUVERABILITY UNDER THE DECK THAT RIGID PIPE SET UPS DO NOT ALLOW IT IS RECOMMENDED THAT REGARDLESS OF FAUCET TYPE A FLEXIBLE HOSE SYSTEM IS USED
11. GECI should be provided by the installer and should be tested on a routine basis To test the GECI push the test button The GECI should interrupt power Push the reset button Power should be restored If the GECI fails to operate this manner there may be a ground current flowing indicating the possibility of an electric shock Do not use this massage bathtub Disconnect the whirlpool bathtub and have the problem corrected by a qualified service representative before using To reduce the risk of electrical shock the dedicated electrical supply circuit s must be grounded To do this connect the third leg of the 3 conductor wiring cable to the grounding terminal of the electrical service panel and run continuously to the green grounding screw on the GFCI or electrical receptacle in the wiring compartment 21 American Standard OWNERS MANUAL SAVE THESE INSTRUCTIONS OPERATING INSTRUCTIONS 1 Enter your American Standard walk in bath close the door place handle in down position and fill the bath to at least 2 inches above the highest jet before activating the whirlpoo pump if equipped Do not apply excessive pressure when placing the handle in the close position Do not put weight on the door when entering and exiting the tub It is recommended to leave the door in the open position when the tub is not in use 2 If your American Standard walk in bath is equipped with Whirlpool Jets Air Spa or Combo system the pump or blower
12. I 15 Amp GFCI Whirlpool Inline Heater Dedicated Circuit 15 Amp GECI All electrical connections must be carried out by a certified electrician in accordance with local electrical requirements and codes Standard OWNERS MANUAL INSTALLATION PROCEDURES A WARNING When installing whirlpool massage baths air spa baths combo baths or Quick Drain equipped baths the following precautions must be followed A WARNING Danger Risk of electrical shock connect components to separate circuits EACH protected by a ground fault circuit interrupter GFCI A WARNING Installation must provide access for servicing the pump and motor all American Standard walk in baths come with access panels for the pump motor and faucet 1 Install tub waste overflow according to instructions included with the provided kits The Gel Coat Series requires the installation of a door drain with check valve The check valve and tubing must be installed horizontal to the floor Some installations will require the purchase of additional fittings 2 American Standard Faucet Installation 9FHS CH o Review the installation instructions packed with the faucet set Mask off the tub s deck with a protective tape Locate and mark the center line of the overflow fitting Locate and mark 1 line either side of the tub s center line to establish the overflow clearance Follow the drill template and faucet installation instructions 3
13. ND FOLLOWED CAREFULLY ALL PRECAUTIONS PERTAINING TO RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS MUST BE UNDERSTOOD AND EXPLAINED TO OWNER TO REDUCE THE RISK OF INJURY CHILDREN OR PERSONS WITH INFIRMITIES MUST NOT BE PERMITTED TO USE THIS PRODUCT WITHOUT CLOSE AND CONTINUOUS SUPERVISION OWNERS MANUAL TESTING YOUR WALK IN TUB BEFORE INSTALLATION 1 All American Standard walk in baths are 100 water tested at the factory and have passed inspection Transportation and mishandling may loosen fittings and cause leaks It is therefore necessary to test the bathtub while there is access to all sides of the bath 2 The unit needs to be filled with water and inspected for leaks along the door as well as the whirlpool and air systems if equipped The inspection needs to be performed with and without the whirlpool and or air systems operating It is best to test the unit outside by filling with a garden hose a Place the tub on a completely flat surface in an area where it may be drained after testing Using a clean rag and warm water wipe down seal to insure it is free of debris Seal the drain hole this can be done with tape and fill the tub to at least three inches above the highest jet or to the bottom of the safety bar if no jets are present Allow the water to stand in tub for 30 minutes and then inspect all plumbing and seals for leaks Using appropriately rated three prong extension cords a
14. ND PHOTOGRAGH ALL PERCEIVED DAMAGE Report all damage claims to customer service at 1 866 423 0800 2 DO NOT LIFT THE TUB BY THE PLUMBING Doing so can result in leaks for which the installer is responsible All Walk In Tubs are water tested before they leave our factory and the bathtub you have purchased has passed inspection 3 Immediately inspect the unit for damage even if there is no carton damage All product damage must be reported within 72 hours of receipt from American Standarde Once the unit is installed surface damages will be assumed to be installation related if not reported prior to installation Installers are also responsible for damage that occurs once the unit is placed in its niche NOTE Remove all packaging material except for the protective plastic This has been placed on the tub at the factory to eliminate abrasions from handling This should only be removed at final clean up 4 Inspect the plumbing for any fittings that may have loosened in transit 5 Read the following instructions completely before installing this product If the home owner or installer has any questions please call us at 1 866 423 0800 6 You must follow all the instructions in this manual FAILURE TO READ AND COMPLY WITH ALL INSTRUCTIONS CAN RESULT IN PRODUCT DAMAGE OR INJURY TO BOTH INSTALLER AND HOMEOWNER IT WILL ALSO RESULT IN ASSUMPTION OF ALL LIABILITY BY SAID INSTALLER OWNERS MANUAL RESPONSIBILI
15. Other Faucet Model and or Brand e Review the installation instructions packed with the faucet set Mask off the tub s deck with a protective tape Locate and mark the center line of the overflow fitting Locate and mark 1 14 line either side of the tub s center line to establish the overflow clearance Verify the first two component mounting clearance on either side of the waste overflow as well as above and below the tub s deck e Verify the remaining component mounting clearance on both sides of the overflow as well as above and below the tub s deck e It is recommended the hand held shower be installed on the corner closest to the wall to prevent water from leaking off the deck and on to the floor 4 Install the optional in line water heater per manufacturer s instructions 5 Standard Walk In Bath Installation After framing is complete set product in place to check fit and make certain that the tub can be properly leveled Caution If the bathtub is not resting on all leveling feet water will not drain properly and this may cause the door to leak Secure tub frame to the studs using metal straps Not provided 5 Fire Rated Drywall If fire rated drywall is specified the finished fire rated wall must be in place before the tub is installed The dimensions of the framing structure must be increased by the thickness of fire rated drywall Standard OWNERS MANUAL INSTALLATION PROCEDURES WARNING
16. RATHER THAN RIGID PIPE CONNECTIONS Amaria Standard OWNERS MANUAL Gelcoat Series Models Installation Dimensions 777 Galvanized Nail FLOOR N ROUGH Dry Wall Dry Wall Galvanized Nail Wall Stud ng Wall Sudi Silicone Tub Integral Flange Non Integral Flange a aeo e xox 7 ro ze 1s ae o eur Flange SEAE 1172 EAE i A Doze meat Flange Tubs installed in an alcove installation require a raised flange to prevent water from seeping past the tub and into the wall Tubs without a raised flange should be installed with a tile flange kit model TFK 60 The flange kit is a long plastic strip that fits onto the rim of the tub to provide the leak protection needed The tile flange should be installed on the tub before it is placed in the alcove Install the tile flange along all sides of the tub where the wall will be Measure to fit and miter cut the flange comers The flange should be attached to the tub with a construction adhesive Once the tub is in place to be installed and flange kit mounted fasten the flange to studs using galvanized fasteners Warning Never attempt to nail or screw thru the tub as this will result in product failure and will void the warranty 12 Amur Standard OWNERS MANUAL Acrylic Series Models Installation Dimensions
17. TIES OF THE INSTALLER The Installer must inspect and water test the product prior to installation to ensure the unit is free of defect and or damage In the event of a problem the unit must not be installed If the packaging or product has been damaged please call immediately at 1 866 423 0800 This product has been listed by INTERTEK ETL and UPC The product has been tested and complies with the following standards and guidelines IAPMO C UPC UL 1795 ANSI Z 124 1 2 ASME A 112 19 7 ASME A 112 19 15 amp CSA B 45 The installer is responsible for compliance to state and local codes This product is designed to be installed by a licensed tradesperson Licensed plumbers and electricians should be employed to insure proper installation Installer assumes all liabilities for installation procedures Although American Standard has taken reasonable precautions to ensure that the Quick Drain is suitable for residential plumbing it is the responsibility of the installer to insure that the plumbing is acceptable for use of the Quick Drain American Standard does not accept responsibility for damage arising from use of the Quick Drain Only accessories authorized by manufacturer should be used with this product IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS SAVE THESE INSTRUCTIONS WARNING ALL INSTRUCTIONS LISTED IN THIS MANUAL SHOULD BE READ A
18. a fifteen 15 year warranty on the bathtub ten 10 year warranty on the tub components and a Lifetime Warranty on the door seal American Standard walk in baths constructed of hi gloss gelcoat construction come with a ten 10 year warranty on the bathtub five 5 year warranty on the tub components and a Lifetime Warranty on the door seal WARRANTY LIMITATIONS In the event of a defect in the material or workmanship of a product defective products will be repaired or replaced The manufacturer shall not be liable for the expense of removing defective products or installing replacement products or the expense of adjoining components such as tile marble wall panels ceilings etc No liability shall exist for incidental or consequential damages caused in whole or part by any defect in this product No warranty expressed or implied including any warranty of merchantability or fitness for a particular purpose shall apply after the warranty period described above This warranty does not cover defects or damage caused by the common carrier or installer from without limitation any of the following careless handling lifting bathtubs by the piping modification of the product for any reason improper installation including installation not in accordance with instructions provided with the unit and acts of God RETURN POLICY American Standard is committed to providing premium customer service In the event that a product must be returned due
19. e following a The pump is plugged into the control box b The control box is plugged into the outlet The control button is plugged into the control box Improper or loose connections open switches or relays blown circuit breakers Manually check rotation of motor shaft for free movement and obstruction Motors Cuts Out Check For o Wiring loose connections etc Low Voltage at motor Frequently caused by undersized wiring Binding or overload Amperage Reading Motor Hums But Will Not Prime Check For Make sure all suction discharge lines and valves are open and un obstructed Check for correct water level Block off suction and determine if pumps develops a vacuum If pump develops a vacuum check discharge line for obstruction or a leak in the suction line If the pump does not develop a vacuum and the pump has the correct water level check for proper voltage and or check the pump wet end for clogging or debris 26 Atabrican Standard OWNERS MANUAL TROUBLE SHOOTING GUIDELINES Whirlpool Pump Motor Will Not Start Check For Check the air line between the motor and air button for connection and depress to test air signal e Improper or loose connections open switches or relays blown circuit breakers e Manually check rotation of motor shaft for free movement and obstruction Motor Cuts Out Check For e Wiring loose connections etc e Low Voltage at motor Frequently caused by unde
20. essure switch may not activate the heater To assure proper heater operation all jets may need to fully open with the pump operating at or near maximum flow Installation of the In Line Heater o Verify there is a dedicated 120 volt 15 Amp Circuit with a GECI outlet available Located the Ready Heater Fitting on the walk in bathtub Loosen the union nuts and remove the Heater Ready Fitting Verify the heater and union fitting threads are the same Placed the ribbed side of the gasket to the union fitting Insert the heater and slowly hand tighten the union nuts to a smug fit to insure proper alignment Once the heater alignment is verified give a turn to each union nut to insure a good seal Fill the tub with water and check for water leaks with and without the whirlpool pump running To dedicated HEATER 120V 15 AMP Circuit UNION FITTING RUBBER GASKET HEATER BLANK Align rubber gasket ring with groove on Unioin Fitting 20 martea Standard OWNERS MANUAL IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS WHEN USING THIS UNIT BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED A WARNING Risk of personal injury Use this unit for its intended use as described in this manual DO NOT use attachments not recommended by the manufacturer A WARNING Risk of personal injury To avoid injury exercise caution when entering or exit
21. g Never attempt to nail or screw thru the tub as this will result in product failure and will void the warranty 13 Americam Standard OWNERS MANUAL Acrylic Extension Kit Installation The Acrylic Extension Kit is designed to accommodate all acrylic walk in tubs to fit within a 60 alcove pocket The top panel measures 30 x 20 depth x width and the front panel 37 4 x 20 height x width The panels must be trim to fit the unit within the 60 alcove Step 1 e Temporary locate the tub within the alcove walls e Level the tub along the deck and apron e Measure and record the distance from the tub and apron to the adjacent alcove wall Extension Kit Parts lt i Measure Distance hu Panel Self Tapping Screw Front Panel Steps 2 3 amp 4 o Mask off and mark the trim lines for the top and front extension panels Using a high speed carbide tooth blade cut along the trim lines Mark a vertical line that is parallel to tub s apron on the adjacent wall of the alcove Install three wood stringers approximately 3 8 below the horizontal and vertical lines Verify the fit of the front panel and then the top panel to the alcove opening Shimming may be required to achieve a level fit Cut Panels Draw cut line according to measured distance Place wood stringers 3 8 below top deck alcove wall Mark a horizontal line that is parallel to the tub s deck along
22. heaters are equipped with a preset pressure switch which will not allow the heater to turn on if the pump is not running with water flowing through the whirlpool system The heater includes an exclusive High Limit Switch This safety circuit will not false trip from hot tap water It will turn off the heater is the thermostat fails If your whirlpool is equipped with adjustable jets or other flow control systems the pre set pressure may not activate the heater To assure proper heater operation all jets may need to fully open with the pump operating at or near maximum flow Heater Will Not Operate Check For 9 Improper or loose connections open switches or relays blown circuit breakers e Wiring loose connections etc 9 Overload Amperage Reading O Zone Generators All O Zone Generators are equipped with a preset vacuum switch which will not turn on if the pump is not running with water flowing through the whirlpool system The O Zone Generator includes an exclusive High Limit Switch and will not false trip from tap water If your whirlpool is equipped with adjustable jets or other flow control systems the pre set vacuum may not activate the generator To assure proper operation all jets may need to fully open with the pump operating at or near maximum flow O Zone Generator Will Not Operate Check For e Improper or loose connections open switches or relays blown circuit breakers Form 0313 28
23. ing your walk in bath WARNING Risk of personal injury To reduce the risk of injury do not permit children or persons with infirmities to use this product unless they are closely supervised at all times A WARNING Risk of hyperthermia and possible drowning People using medications herbal remedies sleep aids and or having adverse medical history should consult a physician before using this product A WARNING Risk of personal injury Water temperatures over a 100 F 38 C may be hazardous to your health Check and adjust water temperature for your personal comfort A WARNING No food or Alcoholic Beverages Use of your bathtub immediately after meals is not recommended Avoid alcohol consumption before or during the bathing Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning A WARNING Pregnancy If you are or think you may be pregnant consult your doctor before using the bathtub WARNING Risk of personal injury Risk of electric shock do not permit electric appliances such as a hair dryer lamp telephone radio or television within four feet of this bathtub A WARNING Risk of personal injury Never drop or insert any objects into any openings A WARNING Risk of personal injury Do not operate this unit without the guard over the suction fittings The unit must be connected only to a supply circuit that is protected by a ground fault circuit interrupter GECI Such a
24. l to the floor Glue all components and tubing in place use PVC Glue Door drain hose should be cut to length to ensure that hose is taught and not sagging Door Drain Assembly Over Flow To Door Drain Drain Cable Tub Wall To Drain Shoe Coupler with 3 8 Barb Coupler will need to be installed at a 45 to 60 angle towards the door side of tub Drain Tee Inline Check Valve SI A N i Drain Shoe Note Valve amp Tubing must be installed 5S at a downward slopled angle so water can drain properly Coupler with 3 8 Barb Note Installed at a angte so hose will not be pressed against bottom of tub wall P Trap 19 Arutricay Standard OWNERS MANUAL Inline Heater Installation Whirlpool In Line Heater All whirlpool systems are deigned with an In Line Heater Blank The threads and union set on the heater blank and heaters are specifically designed for our system All other heaters and heater blanks will not interchanges with our system The heaters are equipped with a preset pressure switch which will not allow the heater to turn on if the pump is not running with water flowing through the whirlpool system The heater includes an exclusive High Limit Switch This safety circuit will not false trip from the hot tap water It will turn off the heater is the thermostat fails If your whirlpool is equipped with adjustable jets or other flow control systems the pre set pr
25. ll plugged in to separate outlets operate all electrical components air blower water pump and heater if applicable for another 30 minutes and inspect for leaks again Inspect the unions around the pump and heater If a leak persists at a union after tightening it may have been over tightened or might have a displaced O ring Disassemble it and make sure the O ring was seated properly Do the same if a leak persists at the heater Verify that the heater threads match the pipe threads Ensure that all jets are open and working some jets are adjustable for both flow rate and direction of flow The jet water flow rate is adjusted by turning either the outside ring or the inside nozzle clockwise or counterclockwise Some jets are not adjustable at the jet face but can be adjust by the Leg s Only Massage The Legs Only Massage Valve is located near the seat If equipped 3 If the pump blower lights heater does not operate a Check the breaker to ensure that power is on and make sure that any cables and or air lines connecting the control boxes to the switches and pumps are firmly attached Verify the correct electrical circuit and amps of the electrical cord b Go to Trouble Shooting Guidelines See pages 23 25 Failure to perform these tests before installation will make the installer liable for future repair costs Do not run any pumps unless the tub is filled with water to the proper level Damage due t
26. marian Standard WALK IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL Aratrican Standard CONGRATULATIONS You are now the owner of a walk in bathtub from the most trusted name in plumbing We thank you for your purchase Your American Standard walk in bath is a true investment in your health and peace of mind Customer Support 866 423 0800 Amarieau Standard OWNERS MANUAL TABLE OF CONTENTS UNPACKING THE UN isa cecen pe alocata a ecua mat a aaa Page 3 RESPONSIBILITIES OF THE 8 0 Page 4 TESTING YOUR TUB BEFORE 5 0 22 Page 5 INSTALLATION 2 Page 6 1 11 0 7 cai cdi oa darea sita in dees i oi ae Page 8 20 SAFETY INSTRUCTIONS lt cica aaa e oana oana deeadiana ien aaa ia s bat Page 21 OPERATING Page 22 23 CLEANING amp eee eee Page 24 WARRANTY setei a e da pita vases cca ati aaa Da ei ai DU dada Page 25 TROUBLESHOOTING tal Page 26 28 mirean Standard OWNERS MANUAL UNPACKING THE UNIT 1 FIRST inspect the carton for damage CAREFULLY DOCUMENT A
27. o dry operation of pumps is not covered under the warranty period See pg 22 Amariean Standard OWNERS MANUAL INSTALLATION PREPARATION 1 Check the floor area where the tub is to be installed a Clean area of any debris or trash b Use a 5 or 6 foot level and determine if the floor is level If the floor is not level adjust all leveling feet to perfectly level the tub Note It is important that all leveling feet are completely touching the floor and level for the door system to work properly Leveling Feet 2 Check to ensure that the drain piping has been roughed in at the proper location See specification sheets installation detail included in this manual 3 Ensure that the proper electrical service has been installed at the pump location See electrical Requirements in the manual See page 7 Standard OWNERS MANUAL ELECTRICAL INSTALLATION electrical wiring must be installed accordance with the National Electrical Code and with all local codes wiring shali be done by a qualified electrician Run one two or three branch circuits as required from the main electrical service panel to the pump area of the framing structure to provide power to the unit Electrical components have specific wiring requirements Refer to the matrix below for the electrical supply requirements for the whirlpool bathtub and factory installed components Branch circuits must be rated for 110
28. our American Standard walk in bath is equipped with an in line heater the heating element will come on automatically but only when the whirlpool system is turned on This heater is designed to extend the comfortable bathing time but does not reheat the bath water 7 If your American Standard walk in bath is equipped with the Automatic Tub Clean System Ozone the system will turn on automatically when the whirlpool system is turned on 8 If your American Standard walk in bath is equipped with the Quick Drain this system has its own dedicated pump suction and switch to activate the drain Simply open the traditional drain system turn the overflow and then press the Quick Drain on off switch to activate the drain When the water falls below the suction guard press the control switch to turn the drain system off 22 Anuriean Standard OWNERS MANUAL SAVE THESE INSTRUCTIONS OPERATING INSTRUCTIONS 9 Ifyour American Standard walk in bath is equipped with Chromatherapy lights the lights have a dedicated control button Pressing the control button off and back on will change the color of light 10 If any factory installed fittings have been removed do not operate the unit A safety hazard may have been created by this modification Seek the help of a qualified professional 11 DO NOT use bubble bath or Epsom salts when any pumps are operating Bath oils may be used however their use will require more frequent purging and
29. p 2 e Mark a horizontal line that is parallel to the tub s deck along the back and adjacent wall of the alcove o Mark a vertical line that is parallel to tub s apron on the adjacent wall of the alcove e Install three wood stringers approximately 3 8 below the horizontal and vertical lines SO Place wood stringers 3 8 below top deck and 3 8 away from end of alcove wall 16 Standard OWNERS MANUAL Gelcoat Extension Kit Installation Step 3 9 Remove the tub from the alcove 9 Install the front and then the top panel with the tub brackets Use brackets to secure Tub Extension to tub deck and apron Use screws to permanently attach Tub Extension Step 4 e Apply the temporary clamps to help support the panels while re locating the tub back into the alcove Remove temporary clamps check level shim if necessary and seal in panels with silicone Final Install Apply silicone between wood stringers and extension panels Slide tub into final installed position 17 Atabrican Standard OWNERS MANUAL Drain Overflow Installation Drain Overflow Information A drain overflow assembly is provided with the tub must be installed on the bath water tested and connected to the sanitary system of the house Some drain overflow kits are packed with the waste flange strainer overflow cover
30. rsized wiring e Binding or overload Amperage Reading Motor Hums But Will Not Prime Check For Make sure all suction discharge lines and valves are open and un obstructed e Check for correct water level e Block off suction and determine if pumps develops a vacuum If pump develops a vacuum check discharge line for obstruction or a leak in the suction line o Ifthe pump does not develop a vacuum and the pump has the correct water level check for proper voltage and or check the pump wet end for clogging or debris Air Massage Motor Will Not Start Check For e Check the air line between the motor and air button for connection and depress to test air signal e Improper or loose connections open switches or relays blown circuit breakers e Manually check rotation of motor shaft for free movement and obstruction Motor Cuts Out Check For e Verify if the air supply line from the blower to the manifold is connected and not obstructed e Wiring loose connections etc e Low Voltage at motor Frequently caused by undersized wiring Chromatherapy Lights Lights Will Not Operate Check For e Check the air line between the control box and air button for connection and depress to test air signal e Wiring and or loose connections etc e Improper or loose connections open switches or relays blown circuit breakers 27 Amaria Standard OWNERS MANUAL TROUBLE SHOOTING GUIDELINES Heaters All
31. to reasons other than defects as mentioned in the warranty the following procedures apply Requests for returns and or exchanges must be made within 30 days of receipt of product The product must be in its original packaging and received at American Standard in saleable condition All returns will receive a 15 restocking fee plus all freight costs of the original shipment and return shipment to American Standard All requests for return must first be approved by American Standard and have an assigned Returned Merchandise Authorization RMA 25 Standard OWNERS MANUAL TROUBLE SHOOTING GUIDELINES WHEN SERVICING THIS UNIT BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED A gt gt gt gt To reduce the risk of injury keep all components in a vented enclosure and out of the reach of children Risk of Electrical Shock Connect only to a grounding type receptacle protected by a ground fault circuit interrupter GFCI Verify all components are installed to dedicated circuit s with the recommended electrical rating All the components are manufactured with 36 pigtail cord and designed to be plugged directly into a ground fault circuit interrupter GFCI DO NOT CUT OR SPLICE INTO THE COMPONET S 3 FOOT PIGTAIL CORD S All components are designed for indoor use on a whirlpool tub Quick Drain Pump Motor Will Not Start Check For Quick Drain Control Button should be illuminated If not verify th

Download Pdf Manuals

image

Related Search

Related Contents

Tecumseh AWF5522EXG Performance Data Sheet  USER`S MANUAL Receipt Printer  Samsung SNV-3082 surveillance camera  取扱説明書  Samsung 931C Priručnik za korisnike    安全上のご注意  es.fujitsu.com/imagen  Harbor Freight Tools 18 Gauge Brad Air Nailer Product manual  Sensor Outpost Field Administration Program User Manual http  