Home
Battic Door Energy Conservation Products E-Z Hatch DELUXE R-42 Installation Guide
Contents
1. of the defect and what course of action needs to be taken to correct the problem A proof of purchase will be required in all cases ADDITIONAL EXCLUSIONS Battic Doors above stated limited warranty is being made in lieu of all implied warranties of any kind including those as provided by the Uniform Commercial Code for merchantability of the product and for fitness of the product fora particular purpose All such implied warranties including those of merchantability and or fitness for a particular purpose are excluded and disclaimed Furthermore all claims for consequential damages and for incidental damages that may arise from a breach of the above mentioned express warranty are also excluded In no event shall Battic Door be liable for any breach of warranty and or for any negligence and or for any Strict liability which would exceed in damage amount the cost of the attic access door unit No representative or person is authorized to assume for Battic Door any responsibility which would be either an alternative to or in addition to the express product warranty as stated above This warranty gives you certain specific legal rights as were set forth above and any other rights that may vary from state to state If any portion of this express warranty is deemed to be unenforceable at any time hereafter any such provision shall be severed from this agreement but all otherterms conditions and provisions shall remain in full force and effect Battic
2. Battic Door Attic Access Hatch Insulation dams prevent loose fill insulation from falling through ACCESS WARNING TOOLS AND Hatch lid pushes up and out of the way for access Benoa ea DOOLA Air seal Home Energy Conservation Products E Z Hatch Attic Access Door System www batticdoorcom Tel 508 320 9082 INSTALLATION GUIDE Read instructions carefully and completely before beginning installation Installer should be experienced in the construction or modification of structural framing supports Improper installation can result in collapse and bodily injury Determine the location of electrical lines or plumbing before cutting ceiling A helper may be needed to lift the frame into the ceiling rough opening Drill tape measure wood shims ladder lumber with same climensions as joists MATERIALS keyhole saw or utility knife to cut ceiling material 8 12 pcs 12x3 wood screws REQUIRED BEFORE INSTALLATION et Confirm that this attic access door and its installation meet all applicable building codes Inspect unit for any damage 1 Select location to install door Closet or hallway is typical 2 Inspect location of ceiling joists or roof trusses in attic to ensure door can be installed in desired location Locating Door UMmMAW 1 Study drawing below 2 Mark out the rough opening 22 1 2 wide x 30 1 2 long between the roof trusses or ceiling joists Prepari
3. Door Energy Conservation Products P O Box 15 Mansfield MA 02045 U S A Tel 508 320 9082 Website www batticdoor com Email info batticdoor com THANK YOU FOR YOUR PURCHASE
4. door from frame Have a helper below lift frame up into rough opening compressing the weatherstrip so the trim is tight against the ceiling 2 Square access door in rough opening 3 Shim and anchor access door frame to joists trusses and headers Use Installing th sufficient number and size of screws 8 12 12 x 3 screws suggested and Access Hatch not provided to adequately secure access door frame Screws must be Door Frame installed flush with inner surface of access door frame 1 Drop door into frame from attic Door rests on weatherstripping on inside of trim 2 Remove any fingerprints or dirt with a moist towel or rag Installing the Access Hatch Door LIMITED WARANTY Battic Door warrants that the unit will be free from any defects in material and workmanship for one year from purchase date provided the access door is installed in compliance with the preceding instructions and operated and maintained in accordance with these instructions and applicable warnings This warranty specifically excludes any and all non defect damage injuries and losses arising from improper installation of product unreasonable use and any and all labor charges incurred for removing or reinstalling a repaired access door unit or any of its components During the warranty period stated should the access door exhibit a manufacturing defect please first call Battic Door at 508 320 9082 before removing product in order to determine the extent
5. ng the 3 Cut the rough opening through the ceiling material Opening trusses or joists 24 o c joists 16 o c 24 16 _ 16 22 112 F o n 30 1 2 gt K install header e we w header cut center joist 22 112 cut center joist ii existing wood joists 3 16 clearance i existing wood joists install header uUum 1 If installation is between joists or trusses spaced 24 o c install access door with long side parallel to joists or trusses Install 2 x 6 or 2 x 8 headers These headers will form the box frame into which the access door will be secured 2 If installation is between joists spaced 16 o c install access door with Framing the short side parallel to joists Cut and remove the center joist and tie in to Opening other joists with 2 x 6 or 2 x 8 headers These headers will form the box Um frame into which the access door will be secured Before cutting any joists watch out for electrical wiring If your attic is constructed using trusses DO NOT CUT CEILING JOISTS WITHOUT CONSULTING AN ENGINEER AND OBTAINING APPROVAL lt is recommended that DOUBLE HEADERS and JOIST BRACES be used for WARNING greater strength and safety m a a p T al a a a a at r m j r ji i a a a x r p a a r s i a a F Typical framing with joists 16 o c center joist cut and headers added 1 Remove