Home

RAIN GUARD CU-0105 Instructions / Assembly

image

Contents

1. CLEAR SEAL High amp Low Gloss Acrylic Urethane Sealer PRODUCT DESCRIPTION Rainguard CLEAR SEAL Acrylic Urethane Sealer is a single component self cross linking urethane acrylic sealer and finish coat for decorative concrete stone and other masonry surfaces CLEAR SEAL a water based low VOC low odor coating can protect your masonry against chemical spills and staining agents UV light and wear due to heavy foot and tire traffic CLEAR SEAL is formulated for use on horizontal or vertical painted or unpainted concrete and wood surfaces It may be used as a clear sealer on commercial warehouse or industrial floors residential or commer cial garage spaces brick pavers or other masonry surfaces PRODUCT FEATURES e Impact and wear resistant e Resists hot tire pick up e Non yellowing formulation e Resistant to stains acids bases gasoline alcohol and oil vegetable and motor e Low odor e Non hazardous e Resists UV rays e Environmentally friendly e Water clean up e Excellent adhesion e Fast dry time and cure time e No pot life issues one component self cross linking system MANUFACTURED BY Rainguard International 3334 East Coast Highway 143 Corona del Mar CA 92625 Weatherman Products Inc Version 01 14 TECHNICAL DATA SHEET Five Years Divisions 7 amp 9 LG Low Gloss Warranty Period CSI Reference HG High Gloss Part Numbers USA Gallon HG CU 0101 5 Gallon H
2. G CU 0105 Gallon LG CU 020 5 Gallon LG CU 0205 International CU 010I CA CU 0105 CA CU 0201 CA CU 0205 CA RECOMMENDED USEs Brick Concrete EFIS or cement plaster Masonry block Stucco Wood Clear protection on murals or painted vertical surfaces Clear sealer for painted or unpainted surfaces Repellent of oil gas and other fluids COVERAGE RATES THEORETICAL Substrate Sq Ft Gallon Porous Surfaces 200 300 Dense Surfaces 300 400 Special Considerations e The coverage will vary with the porosity of the substrate If the substrate is very porous coverage will be reduced Use of fluted or scored block or raked joints will increase surface areas by 20 30 or more and decrease cover age rates Allow for this increased surface area when de termining material requirements Extremely porous surfaces may require multiple coats Office 949 5 15 8800 Fax 949 675 3450 info rainguard com www rainguard com How To USE amp PRECAUTIONS TECHNICAL DATA All surfaces to be coated should be clean of any dirt and grime Material Type Water based urethane efflorescence lime run form oils and release agents grease mud Volume Solids 31 excess mortar and mold and mildew etc All cracks should be Color of Material Off white emulsion in can pointed or caulked All voids bee holes masonry surface defects Mild and openings such as conduits pipes drains door frames vents O C lt 50 g L V O C Compliant air con
3. al temperatures are the distributor s invoice must be submitted to and approved by above 40 F 4 4 C and at least 5 F above the dew point prio Rainguard to painting Do not apply at temperatures below 40 F o when temperatures are ex pected to drop below 40 F within This material is only warranted when applied in accordance with 48 hours of application Do not apply if rain snow or lowe the manufacturer s guidelines and warranty procedures Without temperatures are expected within 48 hours Do not apply if adherence to these specific guidelines no expressed or implied relative humidity is greater than 80 warranty of this product is given Please contact Rainguard for ad Allow at least hour or until tack free before applying a second coat ditional information Wait 24 hours before opening up to light to moderate traffic and 72 hours before heavy traffic TEST PANEL Always apply material to a mock wall or test panel Test wall or actual surface area to determine acceptable color surface porosity applica tion rates and methods before starting general application MANUFACTURED BY Office 949 515 8800 Rainguard International Fax 949 675 3450 3334 East Coast Highway 143 Corona del Mar CA 92625 info rainguard com Weatherman Products Inc Version 01 14 eee d com
4. ditioner openings electrical openings control joints or Gloss Level 20 25 60 any dissimilar materials should be repaired using urethane or Flash Point Non Flammable other approved patching pH Value 7 5 8 5 Viscosity lt 200 cps If an acid etch or an acid stain has been applied to the surface it Weight Approximately 8 6 Ibs gal must be thoroughly flushed to remove all residue and then al Surface Dry Recoat Approx Hour lowed to dry completely Full Chemical Cure 24 to 72 hours Allow new concrete to cure at least 4 days before application of LIMITED WARRANTY PROCEDURES INFORMATION CLEAR SEAL Acrylic Urethane Sealer The information contained herein is offered in good faith and is believed to be accurate To be eligible for a Rainguard Warranty FOLLOW THESE SIMPLE STEPS the following must occur CLEAR SEAL Acrylic Urethane Sealer should be applied using either brush t bar lamb s wool applicator or most pump up sprayers We A site visit must be conducted by an employee or agent of do not recommend using a roller to apply as this may allow too Rainguard and a Field Inspection Report completed much air causing bubbles to stay in the film A Warranty Application must be fully completed by the appli At time of application moisture content of all surfaces should be 30 cator or less as measured with an electronic moisture meter Field Inspection Report Warranty Application and a copy of Establish that air surface and materi

Download Pdf Manuals

image

Related Search

Related Contents

便利な機能(PDF形式, 1.05 MB)  PDFM MODE D`EMPLOI    PVI 1800/2500 Installation and Operation Manual  const._de_tabiqueria  Fiche 0 Sommaire - Chambre Régionale d`agriculture Languedoc  Samsung Galaxy TAB 7.7 Black Kullanıcı Klavuzu  Commentaires    Black & Decker QS800 Instruction Manual  

Copyright © All rights reserved.
Failed to retrieve file