Home

ZALMAN Fan ZM-MFC2 User's Manual

image

Contents

1. 0000 w a CVS Cable PUTED sss FaniA FaniB Fan2 Fan3 Fan4 Temperature Sensors D CVS Extension Cable Outlet Le Bracket Power Cord x The Main AC Power Cord is not provided with ZM MFC2 Z A L M A N x The specifications of product may change without any prior notice to improve performance DC Power Operational Guidelines Four channels of ZM MFC2 detect fan RPM signals The Alarm will activate if a fan is not connected or if there is no RPM input signal for any of the channels To deactivate the Alarm the Stand By Mode default setting ON of each unused channel must be deactivated 1 Selecting a Channel Deactivating Stand By Mode 1 Select a channel with the Mode Button The selected channel will begin to flicker 2 Press the Jog Wheel to deactivate the selected channel s Stand By Mode The fan image will turn off 3 Deactivate the Stand By Mode of all unused channels as mentioned above Note Deactivating the Stand By Mode of all the channels will not deactivate other functions Channel Output RPM Display RPM Setting amp Saving etc 2 RPM Setting and Saving 1 Select a channel with the Mode Button 2 Set the RPM with the Jog Wheel Turning
2. Z A L M A N X The specifications of product may change without any prior notice to improve performance
3. English Ver 1 0 MIU FAN CON TFIROLLEF ZM MFC2 User s Manual Please visit our website www zalman co kr www zalmanusa com and watch the ZM MFC2 installation video to assist you in the installation process ZANANLMAN Please read this manual thoroughly before installation X The specifications of the product may change without any prior notice to improve performance COOL INNOVATIONS Safety Precautions The following precautions and directions are measures against possible accidents and injuries Please read them thoroughly before using this product ZN Warning Neglecting the following may cause serious injury or death gt Opening the cover of the product while the power cord is plugged into the Current Voltage Sensor CVS may cause electrocution of the user or critical damage to the product gt Handling the power cord with wet hands may cause electrocution gt During heavy lightning storms unplug the main power cord from the CVS to prevent possible system damage and fire hazards gt Plugging in the CVS Cable of the CVS into the motherboard s USB port may damage the motherboard and CVS gt If the current to be measured exceeds 10A RMS use a cable or conductor that allows current greater than the current to be measured to flow through it and always connect protective grounding prior to use of this instrument Symbols MNI A CE F NS Alternating current Cauti
4. and 800W The Numeric Power Load Display will read LLL when an overflow occurs LLL indicates power loads beyond the unit s measurable range Fan Status Display The Fan s operation status is indicated with animated propeller images Fan Channels 6 RPM Display During RPM Setting RPM is displayed in units of 6 ORPM and actual operational RPM is displayed in units of 1ORPM Temperature Display Displays temperature readings between 9 C and 99 C Jog Wheel Used for adjusting Fan RPM RPM can be set from 1000 to 5940RPM in units of BORPM Mode Button Used for selecting a Fan Channel and saving the Fan RPM setting Back Panel fi T Fan Temperature Sensor CVS In DC Power Fob os A a E m l A S eA OOE _ 4 i E Standard Fans Fan 1 3 3 Pin fans that include the RPM output function can be connected for use PWM Fan Fan 4 4 Pin fan that includes the PWM function can be connected for use Temperature Sensing Four temperature sensors can be connected CVS Terminal Receives the measured values of the CVS Power Connector Connects with the PSU s 4 Pin connector Z A L M A N X The specifications of product may change without any prior notice to improve performance Installation 1 Turn the compute
5. the Jog Wheel in clockwise motion will increase the RPM and turning it counter clockwise will decrease the RPM 3 Press the Mode Button again to save the set value and to select the next channel If nothing is input for 5 seconds the ZM MFC2 will automatically save the latest setting and leave the Setting Mode 3 Initializing to Default Settings Press the Mode Button for 3 seconds The entire display will be on for 1 second and all fans will be set to 1500 RPM Y Cable Guidelines Use of the Y cable allows the operation of 2 fans with 1 E White Housing channel Please read the following guidelines carefully before use 1 A 3 pin fan must be connected to the White Housing 2 The second fan must be connected to the Blue Housing 3 The fan speed cannot be controlled if a fan is connected to the Blue Housing with no fan connected to the White Housing 4 The fan speed is controlled according to the speed of the fan connected to the White Housing and the specifications of the two fans must be identical Blue Housing Items to Check Before Reporting for Malfunction 1 Check to see that the CVS is properly connected to the ZM MFC2 and PSU 2 Check to see that all the cables are connected properly 3 Check to see if pressing the Mode Button initializes the device to default settings 4 Check the fans specifications 1 The RPM of 2 Pin Fans that do not output RPM signals cannot be controlled Must use 3 Pin Fans that o
6. cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Product Warranty International Thank you for purchasing Zalman s product Warranty If this product has any defects then Zalman guarantees that it can be exchanged within one 1 year from the time of purchase Product exchange is made with the reseller where the product was purchased For further inquiries contact Zalman headquarters at www zalman co kr or via e mail to a representative There will be no exchanges in the following cases A Violation of the Safety Precautions and the instructions in this manual B Human fatality and or property damage due to events of natural causes C External case damage electrical problems and damage to components caused by careless mishandling Disclaimer Zalman Tech Co Ltd is not responsible for any damages due to external causes including but not limited to improper use problems with electrical power accident neglect alteration repair improper installation or improper testing Contact Information lt Zalman Tech Co Ltd gt Homepage www zalman co kr E mail zalman zalman co kr Disposal of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate collection systems lt Zalman USA Inc gt Homepage www zalmanusa com E mail support zalmanusa com
7. on risk of electric shock CE mark Nationally Recognized Testing Laboratory mark Environmental Conditions Neglecting the following may cause minor injuries degrade product conditions or cause malfunction AS Caution gt Operating the product in an extremely cold or hot environment can degrade product performance and life span gt Allowing liquids to enter the product can result in malfunction gt Operating in a humid or non ventilated environment can reduce product life span gt Do not place heavy objects on top of the CVS gt Must use a well wrung out cloth to clean the CVS gt Using the product for purposes not specified by ZALMAN may cause damage to other devices connected to this product gt Must be installed on an easily reachable location Protective conductor terminal Caution risk of danger Federal Communications Commission FCC mark 6 PO Restriction of Hazardous Substances RoHS mark This product must be used under the following environmental conditions a Indoor use b Altitude up to 2 000m c Temperature 5 to 40 Maximum relative humidity 80 for temperatures up to 31 decreasing linearly to 50 relative humidity at 40 MAINS supply voltage fluctuations up to 10 of the nominal voltage d e ZALMAN X The specifications of product may change without any prior notice to improve performance Features 1 Real time display of power consump
8. r s power OFF and unplug the 2 Install the ZM MFC2 into a 5 25 ODD bay as shown Main Power Cord before installing ZM MFC2 in the diagram J gt OJ 5 Connect the Temperature Sensor s plug to ZM MFC2 6 Install the Bracket in the Enclosure and connect and attach the sensors to desired locations the CVS Extension Cable to ZM MFC2 Temperature Sensor CVS In Lo Hl ooon 7 Connect the CVS s CVS Cable to the Bracket 8 Connect the CVS s AC Power Cord to the PSU J Z A L M A N The specifications of product may change without any prior notice to improve performance Connections Power 2 ZM MFC2 Fan Extension Cables CVS AC Power Cord
9. tion 2 Four sensors for temperature monitoring and display 3 Monitoring and control of one PWM fan and three standard fans 4 Alarm system to notify non operation of any of the fans 5 Fan s operation status indicated with animated propeller images Components 1 One ZM MFC2 2 One CVS Current Voltage Sensor 3 One Bracket CVS Extension Cable 4 Four Temperature Sensors 5 Fan Cables 3 Pin 2EA 4 Pin 1EA Y Cable 1EA 6 Four ZM MFC2 Installation Bolts 7 One Bracket Installation Bolts 8 One User s Manual ZM MFC2 Specifications Dimensions 147 x 87 x 42 mm Power amp Temperature Display 30 800W 9 C 99 C Aea 1 X 4 Pin Supports fans with PWM function 3 X 3 Pin Supports fans with RPM output function PWM Regulation Method Fan No 4 Fan RPM Control 60 5940rpm Voltage Control Method Fan No 1 3 Output Current 0 7A Output Voltage 4 11V Input Voltage 12VDC 5VDC CVS Specifications Input 100 240V 50 60 Hz 10A Bypass Output 100 240V 50 60Hz 10A Output 5V 0 03A Z A L M A N X The specifications of product may change without any prior notice to improve performance Front Panel D ORS ZALMAN JEJEJE UIIIIIIOIIIOIIIIOIIOOIIINONIOININIINININN 38 ____ a e roa asst Fess __ dre FAM I FAN 3 FAN H s 8888 8888 Graphic Power Load Meter Displays power between 30 to 800W in 4 stages Numeric Power Load Display Numerically displays power between 30
10. utput 2 clock pulses for each round 2 Connecting a 3 Pin Fan to the PWM 4 Pin connector will not allow RPM control 5 If there are any problems with the fan then noise will interfere with the RPM clock waves This disrupts accurate RPM control 6 Fan RPM cannot be set higher than the fan s specified value If using a 3000RPM fan then setting it to 5000RPM will not cause the fan to operate at 5000RPM 7 For fans with a specified minimum RPM if the fan is set to a low RPM there may be cases in which the fans stop and restart rotating This is not a defect of ZM MFC2 You must set the RPM higher than the specified minimum RPM of the fan Z A L M A N X The specifications of product may change without any prior notice to improve performance Zalman s CNPS Computer Noise Prevention System Products For a stable and noiseless system of the highest quality use Zalman s Ultra Quiet CPU Coolers Ultra Quiet VGA Coolers Ultra Quiet Power Supplies Heatpipe HDD Cooler Fanless Northbridge Coolers and Noiseless Case Fans GAZ X SA Ultra Quiet CPU Cooler Ultra Quiet VGA Cooler Ultra Quiet Power Supply CNPS9700 LED VF900 Cu LED ZM600 HP SSS Fanless Northbridge Cooler Silent Case Fan Heatpipe HDD Cooler ZM NBF47 ZM F1 F2 F3 ZM 2HC2 International Safety and EMC Certifications This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not