York HD User's Manual
Contents
1. N N 2 2 2 N N N 2 2 2 N N 2 2 FC60C3XN1 FC60C2CN1 FC60D3XN1 FC60D2CN1 N N oO I N N 3 4 3 4 3 4 38 38 38 38 38 38 38 38 3 9 3 9 86 86 86 86 86 86 5 83 5 83 5 83 5 83 5 35 5 35 5 35 5 35 5 83 5 83 5 83 5 83 2 2 2 4 OD 1 Od 1 A al Al al A al A ol A a A o Al oal A a A oal A al A A A A A a A adl A A A BY Co A Co A GO A Go A Co Go OT OD OF A A A A OINI OIN ol O1 O1 OF 05 NI OI NI O O CO OD CO 3 4 A Ny N 258931 BTG A 0606 HORIZONTAL DUCT TYPE Refrig Face Operating Application Conn Area Coil Size G 2 1 a TXV Weight Types Sq Ft 56 HD24A3XH1 A 24 367 12 22x24 HD24A2AH1 HD36B3XH1 mes HD48C3XH1 Heat Pump 4 33 3 12 26 x 24 HD48C2CH1 HD60D3XH1 None E 22 anes EI HD60D2CH1 UNCASED UPFLOW A TYPE Refrig Face Operating Application Conn Area bala Coi
2. 2 None 2A 2 2 2 None None 2A 1 x 0 866 3 8 None 2A None 2 i 2C 2 2 None 2C None 2C 2 FC18A2AN1 PC18A2AN1 8 Unitary Products Group e o 5 e FC18B3XN1 FC18B2AN1 PC24A3XN1 PC24A2AN1 PC24B3XN1 PC24B2AN1 PC30AS3XN1 PC30A2AN1 PC30B3XN1 PC30B2AN1 PC35B3XN1 PC35C3XN1 PC36A3XN1 PC36A2AN1 Cooling Swe FC36B3XN1 Heat Pump FC36B2AN1 FC36C3XN1 FC36C2AN1 FC42B3XN1 FC42B2CN1 FC42C3XN1 FC42C2CN1 FC48C3XN1 FC48C2CN1 FC48D3XN1 FC48D2CN1 KR BR A x x x x NI NJ o N m N 2 2 2 2 2 2 2 N N 2 2 N N 2 2 N m m N m N 2 2 2 N NO e N NO O N 2 2 2 NO e N NO e N 2 2 NO N 4 4 4 4 4 4 4 4 4 4 4 4 4 4 NO e N 2 2 N
3. ja 20 5 3 22 5 25 5 Unitary Products Group 258931 BTG A 0606 LIQUID CONN 3 4 MPT SECONDARY DRAIN CONN 3 4 MPT PRIMARY DRAIN CONN OUTLET SAME SIZE AS INLET ALL FLANGES 3 4 THICK COIL HD Dimensions HD Coils C HD24A H1 28 2834 23 3 4 COIL HC Dimensions HD Coils Dimensions Inches Refrigerant Connections Line Line Size HC42C H1 21 5 16 19 1 4 20 3 16 HC60D H1 25 5 16 23 1 4 24 3 16 HC18A H1 15 5 16 13 1 4 14 oe HC30A H1 HC36B H1 17 9 16 15 1 2 16 mE Unitary Products Group 13 258931 BTG A 0606 NOTES 14 Unitary Products Group 258931 0606 NOTES Unitary Products Group 15 NOTES Subject to change without notice Printed in U S A 258931 BTG A 0606 Copyright O by York International Corp 2006 All rights reserved Supersedes 251366 036 21668 001 Rev B 0306 Unitary 5005 Norman Products York OK Group Drive 73069
4. 4 38 2 14 2 18x17 5 Desc 24 2 1 MC24B3XH1 4 38 2 14 2 18x17 5 24 2 1 MC30A3XH1 Desc 4 38 2 14 2 18x 17 5 MC30A2AH1 MC30B3XH1 Desc 4 38 2 14 2 18x 17 5 MC30B2AH MC35B3XH1 m 3 9 3 12 2 16 x 17 5 MC35C3XH1 S x MC36A3XH1 MC36A2AH1 CENT aem 38 2 O D MC36B3XH1 Heat Pump 2 20 x 17 5 MC36B2AH1 MC36C3XH1 4 86 2 14 1 2 20 17 5 MC36C2AH1 MCA2B3XH1 5 83 2 14 2 24 17 5 MCA2B2CH1 MCA2C3XH1 5 83 2 14 2 24 17 5 MCA2C2CH1 48 3 1 5 35 3 12 1 2 22 17 5 MCA8C2CH1 MCA8D3XH1 5 35 3 12 1 2 22 17 5 MCA8D2CH1 MC60D3XH1 5 83 3 12 1 2 24 17 5 MC60D2CH1 MC61D3XH1 2 28 x 17 5 MC61D2CH1 Note MC coils available with a factory installed horizontal drain pan option H s None None None 58 HORIZONTAL CASED Refrig Face Operating eer Rows Tube Tube Fin Application Conn Area Deep Coil Size Geometry Dia Type Weight Types Sq Ft Lbs HC18A3XH1 T 3 40 14x 17 5 HC18A2AH1 1 340 3 12 0 14 175 2 1 1 x 0 866 Enhanced HC36B3XH1 1 Cooling 3 12 2 16 x 17 5 HC36B2AH1 Heat Pump HC42C3XH1 None HC42C3XH1 4 86 3 12 2 20 175 Desc HC42C2CH1 DUC HC60D3XH1 5 83 3 12 2 24x17 5 HC60D2CH1 10 Unitary Products
5. available to allow the installer the flexibility to install the coil at a later date without duct modifica tions FOR DISTRIBUTION USE ONLY NOT TO BE USED AT POINT OF RETAIL SALE 258931 BTG A 0606 COOLING CAPACITY Coil Only Rated Entering MBH Evaporator Temperature and Corresponding Pressure F PSIG Air F CFM Wet Bulb 35 61 5 40 68 5 45 76 0 50 84 0 UPFLOW A TYPE 25 3 23 1 20 6 17 9 18 72 28 1 25 7 22 9 19 9 FC18B aa 26 0 23 5 20 8 17 9 18 8 173 150 126 98 FC24A is PC24A FC24B B5 PC24B s s FC36A um PC36A 67 T 25 363 2 293 99 4 85 5 71 2 56 2 F0480 a 48 a 515 PC600 454 FOOD 367 PCGOD 367 See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity 2 Unitary Products Group 258931 BTG A 0606 COOLING CAPACITY COIL ONLY Entering Air F Evaporator Temperature and Corresponding Pressure F PSIG Wet Bulb FULL CASED TYPE MULTI POSITION MC18A 550 MEM A 1110 MC18B 650 MC24A T MC24B dE 295 visa 15 558 casn 102s m3 200 57 247 72 a MC36A 1150 MC36B 1250 MC36C 1250 1650 MC4BD 1799 1077 8 90 72 88 48 MC6OD 1825 1245 1052 989 8 amp 8 82 MC61D 2000 _ gt _ __ a See Condensing Unit or Heat Pump Technical Guide
6. 0 os 54 0 268 7 uc 27 596 2 48 304 553 249 624 344 See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity 554 zn 764 ax APPLICATION FACTOR RATED CFM VS ACTUAL CFM APPLICATION LIMITATIONS OF RATED AIR FLOW RATED 110 120 These units must be installed in accordance with all national and local safety codes CAPACITY FACTOR 0 96 0 98 100 1 02 1 03 Air flow must be within the minimum and maximum limits approved NOTE Do not exceed minimum maximum CFM limits shown under Air for electric heat evaporator coils and outdoor units Flow Data Entering Air Temperature Limits Wet Bulb Temp F Dry Bulb Temp F Unitary Products Group 5 258931 BTG A 0606 STATIC PRESSURE VS AIRFLOW BASED ON WET COIL UPFLOW CASED A TYPE HORIZONTAL DUCT TYPE Airflow Wet Cai 0 16 800 0 23 1000 80 04 dde 1000 0 15 800 0 21 1000 fs 8o HD24A FC24A PC24A 0 13 800 0 18 1000 0 23 800 0 21 027 800 0 18 1000 0 23 1200 0 29 800 HORIZONTAL CASED 1800 0 20 2000 0 25 FC24B PC24B FC30A PC30A FC30B PC30B FC35B Pe 1000 1200 0 29 FC35C PC35C 1000 NEC NNI FC36A PC36A NEC i 1400 0 07 HC18A 0 12 1000 0 19 800 0 21 0 25 1150 0 30 1200 0 31 ncs 300 1400 FC36C 1000 0 10 PC36C 1200
7. 0 15 1400 0 20 0 21 FC42B 0 28 PC42B 0 34 1800 0 40 1200 0 14 0 19 0 24 1600 0 29 1800 0 35 0 40 0 46 1800 0 30 2000 0 35 0 40 028 2000 0 38 2200 0 43 1600 0 21 027 2000 2200 6 Unitary Products Group 258931 0606 CASED TYPE MULTI POSITION UNCASED UPFLOW TYPE Mode WetCoi _ WetCoi MC18A 80 UC18A 800 1000 0 020 MC18B 0 26 UC18B 1000 0 32 0 o MC24A 0 27 UC24A 1000 0 33 0 o MC24B 0 24 UC24B 1000 0 29 0 o MC30A 0 27 UC30A 1000 0 33 800 UC30B 800 800 800 00 Oj O NO N N O oO O 0 MC30B 80 0 24 0 29 0 02 MC35B 80 0 26 UC36A 034 0 020 MC35C 80 0 24 UC36B 032 80 07 MC36A 0 30 UC36C 0 38 018 MC36B 0 21 UC42B 028 016 MC36C 0 21 LO 026 027 UC48C 1200 0 20 1400 0 25 MC42C NE NE 1600 0 30 1800 0 34 1200 0 24 1400 0 30 48 1600 0 35 1800 0 41 UC60C 1200 0 20 1400 0 26 MC48D NEC AN 1600 0 31 1800 0 36 UC60D 1600 0 27 1800 0 33 MC60D 2000 0 38 2200 0 44 1600 0 24 1800 0 29 MC61D 2000 0 35 2200 0 40 Unitary Products Group 7 258931 BTG A 0606 PHYSICAL DATA CASED FC AND PARTIAL CASED PC UPFLOW A TYPE neirig face Rows Tube Tube Fin Application Conn Area Coil Size TXV Weight Mew Types Sq Ft P P Ed Lbs 2
8. 3XN1 UC36B2AN1 UC36C3XN1 UC36C2AN1 UC42B3XN1 UC42B2CN1 UC42C3XN1 UC42C2CN1 UC48C3XN1 UC48C2CN1 UC48D3XN1 UC48D2CN1 UC60C3XN1 UC60C2CN1 UC60D3XN1 UC60D2CN1 Dimensions PC Coils Refrigerant Factory Line Size Installed TXV R22 PC18A2AN1 n 17 3 4 13 3 8 13 5 3 8 3 4 3 4 2A ERR RM 2 Poss 175 17 1638 85 3834 None CNN 14552178 1338 135 38 34 None _ 34 2A pozen 775 21318 1638 165 38 34 None 145 2178 1938135 38 2A 38 S4 Noe poean 175 1878 16378165 38 None 145 2378 1398 135 6 T8 2m 14512578 13 38 73 5 3 78 None 175 2318 1638 185 38 TB 2 Pesca 21 1278 1078 20 36 21 2278 1878 20 T6 Noe TE 2 _ aru e 20 PowacaxNt 21 27 118 19778 20 38 78 None _ 78 2c Fomcswr zr 2538 1878 20 T6 Noe 255 Ss TB GO _ T8 2c 7 235 TS G0 _ PC coils are not available with a factory installed horizontal pan 3X Models require field installed TXV EN O O O co is Refrigerant line sizes may require larger lines for extended line lengths See York bulletin 690 01 AD1V for details 12
9. Group 258931 BTG A 0606 DIMENSIONS BOTTOM BOTTOM OPENING OPENING DIMENSIONS DIMENSIONS Coil MC Coil FC Dimensions MC Coils Dimensions FC Coils Refrigerant Factory Refrigerant Factory Line Size Installed Line Size Installed Liquid Vapor TXV R22 Liquid Vapor TXV R22 a ea 145 22 1193811857 38_ 14 5 T8 T938 135138 MCTSBZAHT 77 5 22 1638 16 5 38 34 2A 1 2 175 18 1838 165 38 34 2A 2 2 None 2 None 48 2 21 32 11978 20 38 78 2C 48020 245 32 23388235 2C 2 All MC coils include a factory installed horizontal drain pan FC coils are not available with a factory installed horizontal drain pan 3X 5 Models require field installed TXV 3X Models require field installed TXV Refrigerant line sizes may require larger lines for extended line lengths Refrigerant line sizes may require larger lines for extended line lengths See York bulletin 690 01 AD1V for details See York bulletin 690 01 AD1V for details Unitary Products Group 11 258931 BTG A 0606 COIL UC BOTTOM Dimensions UC Coils Dimensions Inches Inches See Connections OPENING DIMENSIONS Coil PC 13 UC18A3XN1 UC18A2AN1 UC18B3XN1 m UC18B2AN1 UC24A3XN1 UC24A2AN1 UC24B3XN1 UC24B2AN1 UC30A3XN1 UC30A2AN1 UC30B3XN1 UC30B2AN1 UC36A3XN1 UC36A2AN1 UC36B
10. TECHNICAL GUIDE ADD ON COILS FOR USE WITH SPLIT SYSTEM COOLING amp HEAT PUMPS MODELS MC PC FC HD HC UC 600 2000 1 5 5 TON COILS HORIZONTAL FULL CASED DUCT MULTI POSITION Ho 3 MC UPFLOW UNCASED UC UPFLOW DOWNFLOW FULL CASED FC UPFLOW HORIZONTAL CASED 9 PARTIAL CASED HC PC i da C U L U L 00 REGIS TEN ISO 9001 Certified Quality Management System Due to continuous product improvement specifications are subject to change without notice Visit us on the web at www york com for the most up to date technical information Additional rating information can be found at www ariprimenet org 258931 BTG A 0606 DESCRIPTION These cooling and heat pump coils are designed to be installed with UPG furnaces and to be matched with UPG cooling and heat pump outdoor units All UPG coils utilize a TXV to provide our customers with the optimum performance and refrigerant control required for 13 SEER systems Coils can be ordered with a R22 TXV factory installed that can be easily converted to R410A by changing the bolt on TXV Flex coils are also available without a factory installed metering device For added application flexibility a R22 or 410 TXV is installed on Flex coils in the field to meet your refrigerant choice Upflow Downflow Coils Full Cased and Partial Cased Coils Designed for high efficiency to match any system full cased in the upfl
11. Total Cooling Capacity and Sensible Capacity Unitary Products Group 3 258931 BTG A 0606 COOLING CAPACITY Coil Only RATED ENTERING MBH Evaporator Temperature and Corresponding Pressure PSIG MODEL CFM AIR Wet Bulb 35 61 5 40 68 5 45 76 0 50 84 0 HORIZONTAL DUCT TYPE 353 215 dE at a 38 396 ss er T 79 st ts 133 0 112 4 69 2 393 See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity Notes MC coils available with a factory installed horizontal drain pan option H COOLING CAPACITY COIL ONLY MBH EVAPORATOR TEMPERATURE AND Rated Entering Air F CORRESPONDING PRESSURE F PSIG CFM Wet Bulb 35 61 5 40 68 5 45 76 0 50 84 0 264 155 243 HC18A 8 13 19 1 __ 127 50 JE 225 267 LE 72 754 dE 58 307 52 248 HC36B 1200 __ A LU 2 Ww HC60C 1800 See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity 4 Unitary Products Group 258931 BTG A 0606 COOLING CAPACITY COIL ONLY Model Rated CFM a Evaporator Temperature and Corresponding Pressure F PSIG Model Coil Rated CFM Entering Air Wet Bulb uncased upflow UC24A UC24B UC36A 115
12. ating Internally Clean evaporator coils are factory leak tested dehydrated sealed and shipped with a holding charge The suction and liquid lines are sealed with rubber plugs no cutting of connection stubs to attach line set Durable Finish Inside and Out Coil casings are made of pre painted steel The pre treated flat galvanized steel provides a better paint to steel bond which resists corrosion and rust creep All inter nal metal parts are made of G90 pre painted steel i e triangular plates top plates horizontal supports etc Coil header plates are non painted due to the brazing process during production Optimum Heat Transfer Using the latest in heat transfer tech nology staggered rows of copper tubes are mechanically expanded into aluminum fins to provide optimum air to surface contact for ample moisture removal as well as high performance ratings ACCESSORIES Refer to Price Manual for specific model numbers TXV Kits Thermal expansion valve kits are available for Flex coil applications and converting R22 to R410A refrigerant or as a service replacement All TXV kits are non braze all connections are bolt on including the valve assembly and equalizer tube No orifice or any other metering device is to used in conjunction with the TXV Coil Casing Without Coil Coil casings are available in each width that can be installed with the furnace or modular air handler during initial installation This option is
13. l Size G 2 e EE TXV Weight Types Sq Ft Lbs UC18A3XN1 None UCTBA3XNT 367 2 14 0 16 165 m UC18A2AN1 UC18B3XN1 None UC18B3XNT 367 2 44 216x165 UC18B2AN1 24 1 UCAMA3XNT 458 2 44 t20x165 Des UC24A2AN1 UC24B3XN1 None UCAMAB3XNT 458 2 14 2 20 165 UC24B2AN1 UC30A3XN1 None UC30A3XN1 458 2 44 2 20 165 UC30A2AN1 UC30B3XN1 None UC30B3XNT 458 2 14 2 20 165 Des UC30B2AN1 Enhanced 1 504 2 14 22 165 UC36A2AN1 UC36B3XN1 j UC36B3XN1 Cooling Sweat 2 22 x 16 5 1 x 0 866 UC36B2AN1 Heat Pump UC36C3XN1 None UC36C3XNT 5 04 2 14 2 22 x 16 5 ELI UC36C2AN1 UCA2B3XN1 None 2 5 96 2 14 2 26 x 16 5 Des UC42B2CN1 UC42C3XN1 None UCA2C3XNT 5 96 2 14 2 26 x 16 5 UCA2C2CN1 UC48C3XN1 Due 5 50 3 12 2 24 x 16 5 UCA8C2CN1 UCA8D3XN1 5 50 3 12 2 24 x 16 5 UCA8D2CN1 UC60C3XN1 5 96 3 12 2 26 x 16 5 UC60C2CN1 uc zz ES ESI a UC60D3XN1 5 96 3 12 2 26x 16 5 UC60D2CN1 Unitary Products Group 9 258931 BTG A 0606 FULL CASED A TYPE MULTI POSITION Refrig Face Operating Application Conn Area ROWS Coil Size Tube Tube rin Weight Dee Geometr Dia Type Types Sq Ft MCTSASXHT x 3 40 44 x 17 5 18 2 1 MC18B3XH1 Desc MC18B2AH1 24 1 EUIS MC24ASXHT
14. ow or downflow and the partial cased in the upflow only application Multi Position Coils Designed for high efficiency like the upflow downflow coil but with the added flexibility that allows it to be installed any position upflow downflow horizontal right or left This coil can be easily applied to our furnace and modular air handler in any configuration Horizontal Duct Coils Available for both cooling and heat pump dedicated horizontal slab coil applications Field transition may be required Dedicated Horizontal Cased Coils These coils are cooling only or heat pump approved for horizontal furnace or modular air handler applications Unlike the horizontal duct coils these cased coils match the dimensions of the furnace or modular blower FEATURES Thermal Expansion Valve Provides flexibility to convert any coil to R22 or R410A refrigerant A true bolt on TXV valve assembly and equalizer tube are bolt on no brazing required TXV and sens ing bulb are mounted inside the cased coil cabinet Must be field supplied for all Flex coils MicroBlue Coated Fins All coils are treated with a MicroBlue Hydrophilic coating to enhance the removal of conden sate during the refrigeration cycle and reduce the possibility of water blow off The MicroBlue coating also reduces the growth of germ causing microbes Insulated Cabinet All evaporator coil cabinets are thermally insulated with foil faced insulation to prevent swe