Xantrex XPH 35-4D User's Manual
Contents
1. Such voltages are exceedingly hazardous and great care should be taken to shield the output terminals for such use On no account should the output terminals be touched when the unit is switched on under such use All connections to the terminals must be made with the power switched off on all units It should be noted that the unit can only source current and cannot sink it thus units cannot be series connected in anti phase The unit can be connected in parallel with others to produce higher currents Where several units are connected in parallel the output voltage will be equal to that of the unit with the highest output voltage setting until the current drawn exceeds its current limit setting upon which the output will fall to that of the next highest setting and so on In constant current mode units can be connected in parallel to provide a current equal to the sum of the current limit settings Ventilation The power supply is very efficient but nevertheless can generate significant heat at full power The supply relies on convection cooling only and it is therefore important that ventilation is never restricted if performance and safety are to be maintained Calibration Allow at least 5 minutes warm up before commencing calibration Access to Calibration Adjustments All adjustments are on the front panel control board all the trimmers are adjusted from the reverse side of the board through holes in the board To gain access to
2. nnen die Schutzeinrichtungen beeintr chtigt sein weshalb das Ger t aus dem Verkehr zur ckgezogen und zur berpr fung und Reparatur eingesandt werden sollte Sicherstellen da nur Sicherungen der vorgeschriebenen Stromst rke und des vorgesehenen Typs als Ersatz verwendet werden Provisorische Sicherungen und der Kurzschluss von Sicherungshaltern ist verboten Beim Reinigen darauf achten dass das Ger t nicht nass wird Am Ger t werden folgende Symbole verwendet Erdungsklemme Netz ON ein Gleichstrom O Netz OFF aus N Wechselstrom Installation Netzbetriebsspannung Das Ger t besitzt einen universellen Eingangsbereich und kann ohne jede weitere Einstellung mit einer Nenn Netzversorgung von 115 oder 230 V betrieben werden Stellen Sie sicher da die Versorgung am Ort den in der Spezifikation aufgef hrten Eingangsanforderungen entspricht Netzkabel Steht nur ein Netzkabel ohne Stecker zur Verf gung so ist es wie folgt anzuschlie en BRAUN STROMF HRENDER LEITER BLAU NULLEITER L GR N GELB SCHUTZLEITER Schutzleitersymbol Bei Steckern mit eingebauten Sicherungen sollte eine 5 Ampere Sicherung verwendet werden Da die Farben der Netzkabeladern nicht unbedingt mit den Farbmarkierungen der Klemmen Ihres Steckers bereinstimmen ist wie folgt vorzugehen Die gr n gelbfarbene Ader ist an die mit E oder mit dem oben abgebildeten Schutzleitersymbol markierte oder gr n bzw Gr n gelbfarbene Steckerklem
3. La commande CURRENT ajuste le courant de sortie et les commandes VOLTAGE r glent la tension maximale qui peut tre engendr e Le t moin CC s allume pour indiquer le mode de courant constant Sortie de courant instantan e Il est possible de r gler la commande de limite de courant pour limiter le courant de sortie continu a des niveaux aussi bas que 10 mA Toutefois ainsi que c est le cas de toutes les alimentations de pr cision sur banc un condensateur est reli aux bornes de la sortie afin de maintenir la stabilit ainsi qu une bonne r ponse transitoire Ce condensateur se charge jusqu la tension de sortie et le court circuitage de la sortie produira une impulsion de courant lors du d chargement du condensateur ind pendamment du r glage de limite de courant Protection La sortie dispose d une protection intrinseque contre les courts circuits et elle est prot g e contre la tension inverse par une diode le courant inverse continu ne doit pas d passer 3A bien qu il soit possible que l intensit des transitoires soit nettement sup rieure La sortie est prot g e contre des tensions directes appliqu es en externe jusqu 40V 15 Fonctionnement Sortie Auxiliaire Tension de sortie La tension de sortie peut tre r gl e entre 1 5V et 5 0V en utilisant la commande rotative du panneau avant pr s des bornes centrales Avec l afficheur de l tat de la sortie principale droite un appui sur le bouton SHOW AUX PRESE
4. di sicurezza TERRA Quando si collega una spina dotata di portafusibile in essa bisogna inserire un fusibile da 5A Se il colore dei fili del cavo non corrisponde ai contrassegni colorati dei contatti della spina procedere come segue Il filo verde e giallo deve essere collegato al morsetto della spina contrassegnato con la lettera E Oppure con il simbolo di sicurezza che rappresenta la terra o di colore verde o verde giallo Il filo blu deve essere collegato al morsetto contrassegnato con la lettera N o di colore nero Il filo marrone deve essere collegato al morsetto contrassegnato con la lettera L o di colore rosso ATTENZIONE QUESTO STRUMENTO DEVE ESSERE COLLEGATO A TERRA Una qualsiasi interruzione sia interna che esterna del collegamento a terra rende pericoloso questo strumento E proibito interrompere questo collegamento deliberatamente Collegamenti collegamenti vanno eseguiti tutti dal pannello frontale Il carico va collegato ai morsetti positivo rosso e negativo nero contrassegnati OUTPUT uscita Il morsetto segnato collegato allo chassis e al terminale di sicurezza di terra Funzionamento Uscite principali Le due uscite principali presentano un funzionamento identico e la seguente descrizione riguarda entrambe Impostazione dell uscita Con il commutatore POWER alimentazione impostato su e l uscita in posizione OFF le uscite in tensione e corrente possono essere impostate in manier
5. is damaged due to improper packaging 2 Include the following e The RMA number supplied by Xantrex Technology Inc clearly marked on the outside of the box e A return address where the unit can be shipped Post office boxes are not acceptable e A contact telephone number where you can be reached during work hours e A brief description of the problem 3 Ship the unit prepaid to the address provided by your Xantrex customer service representative If you are returning a product from outside of the USA or Canada In addition to the above you MUST include return freight funds and are fully responsible for all documents duties tariffs and deposits If you are returning a product to a Xantrex Authorized Service Center ASC A Xantrex return material authorization RMA number is not required However you must contact the ASC prior to returning the product or presenting the unit to verify any return procedures that may apply to that particular facility Out of Warranty Service If the warranty period for your XPH series has expired if the unit was damaged by misuse or incorrect installation if other conditions of the warranty have not been met or if no dated proof of purchase is available your inverter may be serviced or replaced for a flat fee To return your XPH series for out of warranty service contact Xantrex Customer Service for a Return Material Authorization RMA number and follow the other steps outlined in Return Procedure
6. possibility of misinterpretation When an output switch is set to off the current limit setting is displayed enabling conditions to be set before the load is connected With the right hand main output off the right hand meters can be used to momentarily display the preset Auxiliary voltage and current limit The XPH series has been designed to meet the stringent requirements of relevant IEC standards for safety and EMC including harmonics emissions All outputs are intrinsically short circuit proof and are protected against external voltages and reverse currents Specification MAIN OUTPUTS OV to 35V minimum OA to AA minimum Voltage Range Current Range Output Voltage Setting Output Current Setting Operating Mode Output Switch Output Terminals Output Impedance Output Protection Load Regulation Line Regulation Ripple 8 Noise 20MHz bandwidth By coarse and fine controls By single logarithmic control Constant voltage or constant current with automatic cross over Electronic Preset voltage and current displayed when off Universal 4mm safety binding posts on 19mm 0 75 pitch Typically lt 5mQ in constant voltage mode Typically gt 50kQ in constant current mode Output will withstand up to 40V forward voltage Reverse protection by diode clamp for reverse currents up to 3A lt 0 01 of maximum output for 90 load change lt 0 01 of maximum output for 10 line change Typically lt 2
7. provide high levels of power up to 305 watts in a compact and attractive case style High resolution controls allow precise setting of voltage and current levels which are indicated on accurate and legible digital meters Excellent line and load regulation are matched by low noise and good transient response High power efficiency ensures that the unit remains cool without any fan noise The XPH 35 4D has two independent and isolated outputs each with a O to 35V O to 4A capability The outputs operate in constant voltage or constant current mode with automatic cross over and mode indication Each output has its own on off switch Where higher voltages or currents are required the outputs can be wired in either series or parallel to provide voltages up to 70 volts or currents up to 8 Amps The XPH 35 4T has in addition an Auxiliary logic voltage output with a 5A current capability To reflect the increasing usage of low voltage logic devices this output can be preset between 1 5 volts and 5 volts via a front panel control The total power capability is 280 watts for the dual supply and 305 watts for the triple The XPH series incorporates separate digital voltage and current meters on each main output The meters use bright 14mm 0 56 LED displays and have an update rate of 4 per second providing near instantaneous response Simultaneous metering of voltage and current provides accurate information at a glance and avoids any
8. si consiglia di evitare qualsiasi operazione di regolazione e riparazione quando lo strumento sotto tensione e qualora fosse inevitabile dette operazioni devono essere eseguite da una persona specializzata in materia che sia pienamente conscia del pericolo presente Quando sia chiaro che lo strumento difettoso o che ha subito un danno meccanico un eccesso di umidit o corrosione a mezzo di agenti chimici la sicurezza potrebbe essere stata compromessa e lo strumento deve essere ritirato dall uso e rimandato indietro per le prove e le riparazioni del caso Assicurarsi di usare solo fusibili della portata giusta e del tipo corretto durante eventuali sostituzioni Sono proibiti sia l uso di fusibili improvvisati che il corto circuito deliberato dei portafusibili Evitare di bagnare lo strumento quando lo si pulisce Sullo strumento e in questo manuale si fa uso dei seguenti simboli Terminale di terra alimentazione ON accesa u Corrente Continua O alimentazione OFF spenta AQ Corrente Alternata 23 Installazione Tensione d esercizio Questo strumento dotato di un entrata universale e funziona con un alimentazione a 115V o 230V senza regolazione Controllare che la rete locale soddisfi i requisiti d entrata indicati nella specifica Cavo d alimentazione 24 Quando viene fornito un cavo a tre fili con le estremit nude collegare come segue MARRONE LINEA BLU NEUTRO L VERDE GIALLO TERRA Simbolo
9. uscita e la cortocircuitazione dell uscita produrranno un impulso di corrente che indipendente dall impostazione della limitazione di corrente Protezione L uscita dotata di protezione da cortocircuito intrinseca ed protetta dalle tensioni inverse a mezzo di un diodo la corrente inversa continua non deve superare 3 Amp sebbene i transienti possano essere molto pi alti L uscita protetta contro tensioni dirette applicate dall esterno fino a 40V 25 Funzionamento Uscita Ausiliaria Tensione di uscita La tensione di uscita pu essere regolata tra 1 5V e 5 0V usando il potenziometro a fianco dei terminali posti al centro de pannello frontale Impostando in OFF l uscite di destra premendo il pulsante SHOW AUX PRESET verr visualizzata la tensione e la corrente dell uscita ausiliaria sugli indicatori posti a destra Limite di corrente L uscita entra nel limite di corrente tra 5A e 6A l indicatore UNREG non regolata si accende in questa condizione Protezione L uscita dotata di protezione da cortocircuito intrinseca ed protetta dalle tensioni inverse a mezzo di un diodo la corrente inversa continua non deve superare 3 Amp sebbene i transienti possano essere molto pi alti L uscita protetta contro tensioni dirette applicate dall esterno fino a 7V Funzionamento Generale Allacciamento del carico Il carico deve essere collegato ai morsetti d uscita positivo rosso e negativo n
10. OUT LIMITING THE GENERALITY OF THE FOREGOING XANTREX MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE USE OF THE XANTREX XPH SERIES IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES Please note that the XPH series is not intended for use as an uninterruptible power supply and Xantrex makes no warranty or representation in connection with any use of the product for such purposes 34 Return Material Authorization Policy Before returning a product directly to Xantrex you must obtain a Return Material Authorization RMA number and the correct factory Ship To address Products must also be shipped prepaid Product shipments will be refused and returned at your expense if they are unauthorized returned without an RMA number clearly marked on the outside of the shipping box if they are shipped collect or if they are shipped to the wrong location When you contact Xantrex to obtain service please have your instruction manual ready for reference and be prepared to supply e The serial number of your product Information about the installation and use of the unit Information about the failure and or reason for the return e A copy of your dated proof of purchase Return Procedure 1 Package the unit safely preferably using the original box and packing materials Please ensure that your product is shipped fully insured in the original packaging or equivalent This warranty will not apply where the product
11. RODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL DIRECT INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND ANY LOSS OR DAMAGE TO PROPERTY ANY PERSONAL INJURY ANY DAMAGE OR INJURY ARISING FROM OR AS ARESULT OF MISUSE OR ABUSE OR THE INCORRECT INSTALLATION INTEGRATION OR OPERATION OF THE PRODUCT Exclusions If this product is a consumer product federal law does not allow an exclusion of implied warranties To the extent you are entitled to implied warranties under federal law to the extent permitted by applicable law they are limited to the duration of this Limited Warranty Some states and provinces do not allow limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential damages so the above limitation s or exclusion s may not apply to you This Limited Warranty gives you specific legal rights You may have other rights which may vary from state to state or province to province Warning Limitations On Use Please refer to your product manual for limitations on uses of the product SPECIFICALLY PLEASE NOTE THAT THE XPH SERIES SHOULD NOT BE USED IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES WITH
12. Smart choice for power Xd ntrex XPH 35 4D XPH 35 4T Operating Manual XPH Series Dual and Triple Output 35V 4A DC Power Supply www programmablepower com About Xantrex Xantrex Technology Inc is a world leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility scale systems for wind solar batteries fuel cells microturbines and backup power applications in both grid connected and stand alone systems Xantrex products include inverters battery chargers programmable power supplies and variable speed drives that convert supply control clean and distribute electrical power Trademarks XPH series is a trademark of Xantrex International Xantrex is a registered trademark of Xantrex International Other trademarks registered trademarks and product names are the property of their respective owners and are used herein for identification purposes only Notice of Copyright O Xantrex International All rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY S
13. T montrer les r glages auxiliaire provoquera l affichage de la tension et de la limite du courant de la sortie auxiliaire sur l afficheur droit Limite de courant La sortie passe la limite de courant comprise entre 5A et 6A le temoin UNREG d r gler s allume dans ces conditions Protection La sortie dispose d une protection intrinseque contre les courts circuits et elle est prot g e contre la tension inverse par une diode le courant inverse continu ne doit pas d passer 3A bien qu il soit possible que l intensit des transitoires soit nettement sup rieure La sortie est prot g e contre des tensions directes appliqu es en externe jusqu 7V Fonctionnement G n ralit s Connexion la charge Relier la charge aux bornes de sortie positive rouge et n gative noire Les deux bornes sont entierement flottantes et il est possible de relier chacune la terre Connexion en s rie ou en parall le avec d autres sorties Les sorties de l alimentation sont enti rement flottantes et elles peuvent tre utilis es en s rie avec d autres blocs d alimentation afin de produire des tensions c c jusqu a 300V c c La tension maximale admissible entre une borne et la terre gt est de 300V c c la tension maximale admissible entre la borne d une sortie et la borne d une autre sortie de la m me alimentation est galement de 300V c c AVERTISSEMENT Des tensions de ce genre sont extr mement dangereuses et il faut
14. TRODUCTION D EAU DANS LE BOITIER AFIN D EVITER TOUT CHOC ELECTRIQUE ET DEGATS AU BLOC D ALIMENTATION NE JAMAIS UTILISER DE DISSOLVANTS POUR NETTOYER LE BLOC AFIN D EVITER D ENDOMMAGER LE BOITIER OU LE CADRAN D AFFICHAGE 17 18 Sicherheit Dieses Ger t wurde nach der Sicherheitsklasse Schutzart der IEC Klassifikation und gem den europ ischen Vorschriften EN61010 1 Sicherheitsvorschriften f r elektrische Mess Steuer Regel und Laboranlagen entwickelt Es handelt sich um ein Ger t der Installationskategorie Il das f r den Betrieb von einer normalen einphasigen Versorgung vorgesehen ist Das Ger t wurde gem den Vorschriften EN61010 1 gepr ft und in sicherem Zustand geliefert Die vorliegende Anleitung enth lt vom Benutzer zu beachtende Informationen und Warnungen die den sicheren Betrieb und den sicheren Zustand des Ger tes gew hrleisten Dieses Ger t ist f r den Betrieb in Innenr umen der Umgebungsklasse 2 f r einen Temperaturbereich von 5 C bis 40 C und 20 80 relative Feuchtigkeit nicht kondensierend vorgesehen Gelegentlich kann es Temperaturen zwischen 10 C und 5 C ausgesetzt sein ohne dass seine Sicherheit dadurch beeintr chtigt wird Betreiben Sie das Ger t jedoch auf keinen Fall solange Kondensation vorhanden ist Ein Einsatz dieses Ger tes in einer Weise die f r diese Anlage nicht vorgesehen ist kann die vorgesehene Sicherheit beeintr chtigen Auf keinen Fall das Ger t au erha
15. UCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK Date and Revision April 2008 Revision 4 Part Number 975 0101 01 04 Contact Information Telephone 1 800 733 5427 toll free in North America 1 858 450 0085 direct Fax 1 858 678 4481 Email service programmablepower com sales programmablepower com Web www programmablepower com Introduction Specification EMC Safety Installation Connections Operation Main Outputs Operation Auxiliary Output Operation General Calibration Maintenance Instructions en Francais S curit Installation Connexions Fonctionnement Sorties principales Fonctionnement Sortie Auxiliaire Fonctionnement G n ralit s Maintenance Bedienungsanleitung auf Deutsch Sicherheit Installation Anschl sse Betrieb Hauptausg nge Betrieb Hilfsausgang Betrieb Allgemein Wartung Istruzioni in Italiano Sicurezza Installazione Collegamenti Funzionamento Uscite principali Funzionamento Uscita Ausiliaria Funzionamento Generale Manutenzione Instrucciones en Espa ol Seguridad Instalaci n Conexiones Operaci n Salidas Principales Operaci n Salida Auxiliar Operaci n General Mantenimiento Warranty Information Table of Contents OO 09 0 W aa N O 13 14 14 15 16 16 17 18 19 19 20 21 21 22 23 24 24 25 26 26 27 28 29 29 30 31 31 32 33 Introduction The XPH 35 4D and XPH 35 4Tv
16. a accurata utilizzando i le manopole VOLTAGE tensione e CURRENT corrente il misuratore di sinistra mostra la tensione impostata mentre quello di destra indica la corrente massima impostata Quando le uscite sono abilitate ON gli indicatori sono accesi il misuratore di sinistra mostra ora la tensione effettiva mentre il misuratore di destra riporta la corrente di carico effettiva Tensione costante La tensione di uscita viene regolata usando i comandi di VOLTAGE tensione approssimata e precisa il comando CURRENT permette di definire la corrente massima che si pu fornire Corrente costante Se la resistenza al carico sufficientemente bassa da far s che con la tensione di uscita impostata scorra una corrente superiore al limite impostato l alimentazione assumer automaticamente un funzionamento a corrente costante L uscita di corrente viene regolata con il comando CURRENT mentre i comandi VOLTAGE impostano la tensione massima che possibile generare L indicatore CC si accende per mostrare il funzionamento a corrente costante Uscita di corrente istantanea Il comando di limitazione di corrente pu essere impostato per limitare la corrente di uscita continua a livelli fino a 10mA Tuttavia in comune con tutti gli alimentatori da banco di precisione sull uscita collegato un condensatore che consente di mantenere stabilit ed una buona risposta ai transienti Le scariche di questo condensatore alla tensione di
17. afety Earth Symbol When fitting a fused plug a 5 amp fuse should be fitted inside the plug As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol shown above or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Intentional interruption is prohibited Connections All connections are made from the front panel The load should be connected to the positive red and negative black terminals marked OUTPUT The terminal marked is connected to the chassis and safety earth ground Operation Main Outputs The operation of both main outputs is identical the following description applies to both Setting Up the Output With the POWER switch on I and the output OFF the output voltage and current limit can be accurately preset using the VOLTAGE and CURRENT controls the left hand meter sh
18. alelo a otras para producir una corriente superior Cuando varias unidades est n conectadas en paralelo el voltaje de salida ser igual al de la unidad con el reglaje voltaje de salida superior hasta que la corriente suministrada supere el l mite de corriente fijado lo que resultar en la salida bajando al mayor l mite siguiente fijado y as sucesivamente En la modalidad de corriente constante las unidades pueden conectarse en paralelo para proporcionar una corriente igual a la suma de los l mites de corriente fijados Ventilaci n El suministro de fuerza es muy eficaz pero puede generar mucho calor a fuerza plena El suministro depende de enfriamiento por convecci n solamente y por lo tanto es importante que la ventilaci n no est restringida si se quiere mantener el rendimiento y la seguridad 31 Mantenimiento Los fabricantes o sus agentes en el extranjero ofrecen un servicio de reparaci n para toda unidad que desarrolle un defecto Si los propietarios desearan establecer su propio servicio esto s lo debe realizarse por personas cualificadas en conjunto con el manual de servicio que puede adquirirse directamente del Fabricante o de sus agentes en el extranjero Fusible El tipo correcto del fusible es 10 Amperios 250V HBC retardo T 5 x 20mm Se debe observar que la funcci n principal del fusible es hacer seguro instrumento y limitar el da o en el caso de una aver a de uno de los dispositivos interruptores Si falla
19. anne Si le propri taire de l appareil d cide d effectuer lui m me la maintenance ceci doit uniquement tre effectu par un personnel sp cialis qui doit se r f rer au manuel d entretien que l on peut se procurer directement aupr s du Constructeur ou de ses agents l tranger Fusible Type de fusible correct 10A 250V HBC temporis T 5 x 20 mm Il faut noter que l objet principal de ce fusible est de rendre l instrument non dangereux et de limiter les d g ts en cas de panne d un des dispositifs de commutation En cas de panne d un fusible il est tr s probable que le fusible de rechange sautera galement tant donn que l alimentation est probablement d fectueuse lorsque c est le cas il faudra renvoyer l instrument chez le constructeur en vue de r parations Uniquement remplacer les fusibles par des fusibles d intensit nominale requise et de type sp cifi Il est interdit d utiliser des fusibles bricol s et de court circuiter des porte fusibles Pour remplacer un fusible commencer par debrancher l instrument de l alimentation c a Enlever les 7 vis d immobilisation du couvercle puis enlever le couvercle Remplacer le fusible par un autre de type correct puis remettre le couvercle Nettoyage S il faut nettoyer le bloc d alimentation utiliser un chiffon l g rement imbib d eau ou d un d tergent doux Nettoyer le cadran d affichage au moyen d un chiffon sec et doux AVERTISSEMENT EMPECHER TOUTE IN
20. ant alternatif c a 13 Installation Tension d utilisation secteur Cet instrument a une plage d entr e universelle et il fonctionne sur une alimentation secteur de 115 V ou de 230 V tension nominale sans ajustement aucun V rifier que l alimentation locale satisfait aux imp ratifs d entr e c a indiqu s aux Caract ristiques techniques C ble secteur 14 Relier de la mani re suivante tout c ble secteur trois conducteurs fils nus MARRON SECTEUR SOUS TENSION BLEU SECTEUR NEUTRE L VERT JAUNE TERRE Symbole Terre de protection Lors du montage d une fiche fusible mettre un fusible de 5 A l int rieur de la fiche Il est possible que les couleurs des fils du c ble secteur de cet appareil ne correspondent pas aux marques de couleur d identification des bornes de la fiche et par suite il est recommand de proc der de la mani re suivante Relier le fil vert et jaune la borne de la fiche d sign e par la lettre E ou par le symbole Terre de protection indiqu ci dessus ou qui est en vert ou en vert et jaune Relier le fil bleu la borne d sign e par la lettre N ou qui est en noir Relier le fil marron la borne d sign e par la lettre L ou qui est en rouge AVERTISSEMENT CET INSTRUMENT DOIT ETRE RELIE A LA TERRE Toute interruption du conducteur de terre secteur l int rieur ou l ext rieur de l instrument rendra l instrument dangereux Il est absolument interdit d effectuer une inter
21. be much higher The output is protected against externally applied forward voltages of up to 40V Operation Auxiliary Output Output Voltage The output voltage can be set between 1 5V and 5 0V using the front panel rotary adjustment beside the centre terminals With the right hand main output OFF pressing the SHOW AUX PRESET button will display the AUX output voltage and current limit on the right hand meters Current Limit The output will go into current limit at between 5A and 6A the UNREG lamp lights in this condition Protection The output has intrinsic short circuit protection and is protected from reverse voltages by a diode the continuous reverse current must not exceed 3 Amps although transients can be much higher The output is protected against externally applied forward voltages of up to 7V Operation General Connection to the Load The load should be connected to the positive red and negative black output terminals Both are fully floating and either can be connected to ground Series or Parallel Connection with Other Outputs The outputs of the power supply are fully floating and may be used in series with other power supply units to generate high DC voltages up to 300V DC The maximum permissible voltage between any terminal and earth ground is 300VDC the maximum permissible voltage between either terminal of one output and any terminal of another output on the same supply is also 300VDC WARNING
22. d even if the power supply has been disconnected from all voltage sources but will be safely discharged about 10 minutes after switching off power Any adjustment maintenance and repair of the opened instrument under voltage shall be avoided as far as possible and if inevitable shall be carried out only by a skilled person who is aware of the hazard involved If the instrument is clearly defective has been subject to mechanical damage excessive moisture or chemical corrosion the safety protection may be impaired and the apparatus should be withdrawn from use and returned for checking and repair Make sure that only fuses with the required rated current and of the specified type are used for replacement The use of makeshift fuses and the short circuiting of fuse holders is prohibited Do not wet the instrument when cleaning it The following symbols are used on the instrument and in this manual Earth ground terminal mains supply OFF mains supply ON alternating current ac 2 od direct current dc Installation Mains Operating Voltage This instrument has a universal input range and will operate from a nominal 115V or 230V mains supply without adjustment Check that the local supply meets the AC Input requirement given in the Specification Mains Lead When a three core mains lead with bare ends is provided this should be connected as follows BROWN MAINS LIVE BLUE MAINS NEUTRAL L GREEN YELLOW EARTH S
23. diante un diodo la corriente continua al rev s no debe exceder 3 Amperios aunque las ondas transitorias pueden estar mucho superior a esto La salida est protegida contra tensiones directas aplicadas externamente de hasta 7V Operaci n General Conexi n a la Carga La carga debe conectarse a los bornes de salida OUTPUT positivos rojos y negativos negros Ambos bornes son completamente flotantes y cualquiera de ellos puede conectarse a tierra Conexi n en Serie o en Paralelo a Otras Salidas Las salidas del suministro de fuerza son completamente flotantes y pueden emplearse en serie con otras unidades de suministro de fuerza para generar altos voltajes de CC de hasta 300V CC La tensi n m xima admisible entre cualquier borne y la tierra f sica es de 300 VCC la tensi n m xima admisible entre uno u otro de los bornes de una salida y cualquier borne de otra salida del mismo suministro tambi n es de 300 VCC ADVERTENCIA Dichos voltajes son extremamente peligrosos y se debe tener mucho cuidado de proteger a los bornes de salida durante tal uso Bajo ninguna circunstancia se debe tocar a los bornes de salida si el aparato est conectado de ese modo Toda conexi n a los bornes debe efectuarse con los aparatos desconectados Se debe observar que la unidad s lo puede suministrar corriente pero no puede sumirla consecuentemente las unidades no pueden conectarse en serie de modo antif sico La unidad puede conectarse en par
24. eln einer Sicherung zuerst das Ger t von seiner Wechselstromversorgung trennen Dann die 7 Befestigungsschrauben des Geh uses entfernen und danach das Geh use abheben Sicherung durch eine korrekte Ersatzsicherung ersetzen und Geh use wieder montieren Reinigung 22 Falls die Stromversorgung der Reinigung bedarf einen mit Wasser oder einem milden Detergens angefeuchteten Lappen benutzen Anzeigefenster mit einem weichen trockenen Lappen polieren WARNUNG ZUR VERMEIDUNG EINES ELEKTRISCHEN SCHLAGS BZW BESCH DIGUNG DER STROMVERSORGUNGSEINHEIT DAF R SORGEN DASS KEIN WASSER INS GEH USE EINDRINGT UM SCHADEN AM GEH USE BZW AM ANZEIGEFENSTER ZU VERMEIDEN KEINE L SUNGSMITTEL ZUR REINIGUNG VERWENDEN Sicurezza Questo strumento appartiene alla Categoria di Sicurezza 1 secondo la classifica IEC ed stato progettato in modo da soddisfare i criteri EN61010 1 requisiti di Sicurezza per Apparecchiature di misura controllo e per uso in laboratorio uno strumento di Categoria d installazione Il ed inteso per il funzionamento con un alimentazione normale monofase Questo strumento ha superato le prove previste da EN61010 1 e viene fornito in uno stato di sicurezza normale Questo manuale contiene informazioni e avvertenze che devono essere seguite per assicurare un funzionamento sicuro e mantenere lo strumento in condizioni di sicurezza Questo strumento progettato per uso all interno e in un ambiente d inquinamento Grad
25. ent has been tested in accordance with EN61010 1 and has been supplied in a safe condition This instruction manual contains some information and warnings which have to be followed by the user to ensure safe operation and to retain the instrument in a safe condition This instrument has been designed for indoor use in a Pollution Degree 2 environment in the temperature range 5 C to 40 C 20 80 RH non condensing It may occasionally be subjected to temperatures between 5 C and 10 C without degradation of its safety Do not operate while condensation is present Use of this instrument in a manner not specified by these instructions may impair the safety protection provided Do not operate the instrument outside its rated supply voltages or environmental range WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Intentional interruption is prohibited The protective action must not be negated by the use of an extension cord without a protective conductor When the instrument is connected to its supply terminals may be live and opening the covers or removal of parts except those to which access can be gained by hand is likely to expose live parts The apparatus shall be disconnected from all voltage sources before it is opened for any adjustment replacement maintenance or repair Capacitors inside the power supply may still be charge
26. ero Ambedue sono completamente flottanti e uno qualsiasi dei due pu essere collegato a terra Collegamento in serie parallelo con altre uscite Le uscite del dispositivo di alimentazione sono completamente flottanti e possono essere usate in serie con l uscita di altri dispositivi si alimentazione per generare tensioni pi alte fino a 300V c c La tensione massima ammessa tra un morsetto qualsiasi e il morsetto di terra L 300Vc c la tensione massima ammessa tra un morsetto dell uscita e qualsiasi morsetto di un altra uscita sulla stessa alimentazione anch essa 300Vc c ATTENZIONE Queste tensioni sono estremamente pericolose e bisogna assicurarsi nel modo pi assoluto di coprire i morsetti d uscita Quando l unit usata in questo modo ed accesa non si devono assolutamente toccare i morsetti d uscita Tutti i collegamenti ai morsetti vanno fatti quando l alimentazione per tutte le unit spenta da notare che questo dispositivo pu solo generare corrente e non pu dissiparla per questa ragione le unit non possono essere collegate in serie in antifase Il dispositivo pu essere collegato in parallelo con altri dispositivi di alimentazione per produrre correnti pid alte Quando vari gruppi sono collegati in parallelo la tensione d uscita sar uguale a quella del gruppo impostato sulla tensione pi alta fino a quando non si eccede il limite di corrente impostato a questo punto la tensione in uscita impostata
27. etrachtliches Ma an W rme erzeugen Die K hlung der Stromversorgung erfolgt ausschlie lich durch Konvektion weshalb es wichtig ist da die Ventilation niemals eingeschr nkt wird wenn Leistung und Sicherheit aufrecht erhalten werden sollen 21 Wartung Die Hersteller bzw deren Vertretungen im Ausland bieten die Reparatur von Ger ten an bei denen eine St rung aufgetreten ist Wenn der Eigent mer die Wartungsarbeiten selbst durchf hren m chte hat er daf r Sorge zu tragen da diese Arbeiten ausschlie lich von entsprechend qualifiziertem Personal und gem Wartungshandbuch ausgef hrt werden das direkt von den Herstellern oder deren Vertretungen im Ausland bezogen werden kann Sicherungen Korrekter Sicherungstyp Tr ge Hochleistungssicherung T 10 Amp 250V 5x 20 mm Beachten Sie bitte da die Hauptfunktion der Sicherung der Schutz von Personen sowie Ger teteilen ist bzw die Begrenzung solcher Sch den im Falle von St rungen an den Schaltger ten Brennt eine Sicherung durch so ist es h chst wahrscheinlich da auch ihr Ersatz durchbrennt weil eine St rung im Ger t vorliegt In einem solchen Falle ist es erforderlich da das Ger t vom Hersteller repariert wird Achten Sie darauf da nur Sicherungen der vorgeschriebenen Stromst rke und des angegebenen Typs als Ersatzsicherungen verwendet werden Die Verwendung von Behelfssicherungen und das Kurzschlie en von Sicherungshaltern ist verboten Zum Auswechs
28. i n de ambas salidas principales es id ntica la siguiente descripci n aplica a ambas Ajuste de la Salida Con el interruptor de alimentaci n en ON I y la salida OFF de la tensi n de salida y el l mite de corriente con precisi n usando los controles de VOLTAGE y CURRENT el medidor a la izquierda indica la tensi n ajustada y el medidor a la derecha indica la corriente m xima preajustada Cuando el bot n de salida se cambia a ON la l mpara de se enciende ahora el medidor a la izquierda indica la tensi n efectiva y el medidor a la derecha indica la corriente de carga efectiva Tensi n Constante Se ajusta la tensi n de salida usando los controles fino y grueso de VOLTAGE Tensi n el control de CORRIENTE ajuste la corriente m xima que se puede suministrar Corriente Constante Si la resitencia de carga es suficientemente baja tal que con la tensi n de salida ajustada correr una corriente mayor que el limite de corriente ajustado y la a imentaci n el ctrica cambiar autom ticamente a operaci n con corriente constante Se ajusta la salida de corriente con el control CURRENT y los controles VOLTAGE ajustan la tensi n m xima que se puede generar Se ilumina la l mpara CC para indicar el modo de corriente constante Salida Instant nia de Corriente Se puede ajustar el control de l mite de la corriente para limitar la salida de corriente continua a niveles de hasta 10mA Sin embargo en com n con todas
29. ies with EN61010 1 Complies with EN61326 260 x 160 x 320mm WxHxD 4 3kg EMC This instrument has been designed to meet the requirements of the EMC Directive 89 336 EEC Compliance was demonstrated by meeting the test limits of the following standards Emissions EN61326 1998 EMC product standard for Electrical Equipment for Measurement Control and Laboratory Use Test limits used were a Radiated Class B b Conducted Class B c Harmonics EN61000 3 2 2000 Class A the instrument is Class A by product category Immunity EN61326 1998 EMC product standard for Electrical Equipment for Measurement Control and Laboratory Use Test methods limits and performance achieved were a EN61000 4 2 1995 Electrostatic Discharge 4kV air 4kV contact Performance A b EN61000 4 3 1997 Electromagnetic Field 3V m 80 AM at 1kHz Performance B c EN61000 4 11 1994 Voltage Interrupt 1 cycle 100 Performance B d EN61000 4 4 1995 Fast Transient 1kV peak AC line 0 5kV peak DC Outputs Performance B e EN61000 4 5 1995 Surge 0 5kV line to line 1kV line to ground Performance B f EN61000 4 6 1996 Conducted RF 3V 80 AM at 1kHz AC line only DC Output connections lt 3m not tested Performance A According to EN61326 the definitions of performance criteria are Performance criterion A During test normal performance within the specification limits Performance criterion B During te
30. improper use or use in an unsuitable environment b the product if it has been subjected to fire water generalized corrosion biological infestations or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the Xantrex product specifications including high input voltage from generators and lightning strikes c the product if repairs have been done to it other than by Xantrex or its authorized service centers hereafter ASCs d the product if it is used as a component part of a product expressly warranted by another manufacturer e the product if its original identification trade mark serial number markings have been defaced altered or removed Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS WHERE PERMITTED BY LAW IN LIEU OF ALL OTHER WARRANTIES CONDITIONS GUARANTEES REPRESENTATIONS OBLIGATIONS AND LIABILITIES EXPRESS OR IMPLIED STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT HOWEVER ARISING WHETHER BY CONTRACT TORT NEGLIGENCE PRINCIPLES OF MANUFACTURER S LIABILITY OPERATION OF LAW CONDUCT STATEMENT OR OTHERWISE INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE P
31. isface los requisitos de entrada CA que se estipulan en Especificaciones Cable de Red Cuando se suministra un cable de tres conductores con puntas peladas se deber conectar como sigue MARRON CORRIENTE DE RED AZUL NEUTRO DE RED L VERDE AMARILLO TIERRA Simbolo de Seguridad de Tierra Cuando se instale un enchufe fusibleado el enchufe debe llevar un fusible de 5 amp Dado a que los colores de los cables del conductor de alimentaci n del aparato pueden diferir de los colores marcados en los bornes de su enchufe proceder como sigue El cable de color verde y amarillo debe conectarse al borne del enchufe marcado con la letra E o con el s mbolo de seguridad de tierra mostrado arriba o coloreado verde o verde y amarillo El cable de color azul debe conectarse al borne marcado con la letra N o de color negro El cable de color marr n debe conectarse al borne marcado con la letra L o de color rojo ADVERTENCIA ESTE INSTRUMENTO DEBE CONECTARSE A TIERRA Cualquier interrupci n del conductor a tierra dentro o fuera del instrumento implicar a que el instrumento resultara peligroso Est prohibida cualquier interrupci n intencional Conexiones Todas las conexiones se efectuan desde el panel delantero La carga debe conectarse a los bornes positivos rojos y negativos negros marcados OUTPUT Salida El borne marcado est conectado al bastidor y a la seguridad de tierra 29 Operaci n Salidas Principales La operac
32. it dem Knopf CURRENT Strom wird der Maximalstrom eingestellt der zur Verf gung gestellt werden soll Konstantstrom Ist der Belastungswiderstand ausreichend niedrig da bei der eingestellten Ausgangsspannung ein Strom flie en w rde der gr er w re als die eingestellte Strombegrenzung so schaltet die Stromversorgung automatisch auf konstanten Strombetrieb Der Stromausgang wird mit dem Knopf CURRENT eingestellt und die maximal generierbare Spannung mit dem Knopf VOLTAGE Die CC Leuchte leuchtet bei eingeschaltetem Konstantstrommodus auf Augenblickstromausgang Mit der Strombegrenzung kann der kontinuierliche Ausgangsstrom bis auf 10 mA begrenzt werden Wie bei allen Pr zisions Stromversorgungs Tischger ten ist der Ausgang zur Aufrechterhaltung der Stabilit t und zwecks gutem Einschwingverhalten mit einem Kondensator versehen Der Kondensator wird bis zur H he der Ausgangsspannung aufgeladen Ein Kurzschlie en des Ausgangs bewirkt beim Entladen des Kondensators einen Stromimpuls der von der Strombegrenzungseinstellung unabh ngig erfolgt Schutzvorrichtungen 20 Der Ausgang ist mit einem eigenen Kurzschlu schutz versehen und mittels Diode vor Umkehrspannungen gesch tzt Kontinuierlicher Umkehrstrom darf 3 Amp nicht berschreiten Transiente Str me k nnen jedoch wesentlich h her liegen Der Ausgang ist vor extern angelegten Durchla spannungen von bis zu 40V Betrieb Hilfsausgang Ausgangsspannung Die Ausgang
33. l appareil avant de l ouvrir pour effectuer des r glages remplacements travaux d entretien ou de r parations Les condensateurs qui se trouvent dans le bloc d alimentation risquent de rester charg s m me si le bloc d alimentation a t d connect de toutes les sources de tension mais ils se d chargeront en toute s curit environ 10 minutes apr s extinction de l alimentation Eviter dans la mesure du possible d effectuer des r glages travaux de r parations ou d entretien lorsque l instrument ouvert est branch au secteur mais si c est absolument n cessaire seul un technicien comp tent au courant des risques encourus doit effectuer ce genre de travaux S il est vident que l instrument est d fectueux qu il a t soumis des d g ts m caniques une humidit excessive ou une corrosion chimique la protection de s curit sera amoindrie et il faut retirer l appareil afin qu il ne soit pas utilis et le renvoyer en vue de v rifications et de r parations Remplacer les fusibles uniquement par des fusibles d intensit nominale requise et de type sp cifi Il est interdit d utiliser des fusibles bricol s et de court circuiter des porte fusibles Eviter de mouiller l instrument lors de son nettoyage Les symboles suivants se trouvent sur l instrument ainsi que dans ce manuel Borne de terre masse alimentation secteur ON allum e courant continu c c O alimentation secteur OFF teinte AN cour
34. l utilisateur afin d assurer un fonctionnement de toute s curit et de conserver l instrument dans un tat de bonne s curit Cet instrument a t concu pour tre utilis en interne dans un environnement de pollution Degr 2 plage de temp ratures 5 C 40 C 20 80 HR sans condensation Il peut tre soumis de temps autre des temp ratures comprises entre 5 C et 10 C sans d gradation de sa s curit Ne pas l utiliser lorsqu il y a de la condensation Toute utilisation de cet instrument de mani re non sp cifi e par ces instructions risque d affecter la protection de s curit conf r e Ne pas utiliser l instrument l ext rieur des tensions d alimentation nominales ou de la gamme des conditions ambiantes sp cifi es AVERTISSEMENT CET INSTRUMENT DOIT ETRE RELIE A LA TERRE Toute interruption du conducteur de terre secteur l int rieur ou l ext rieur de l instrument rendra l instrument dangereux Il est absolument interdit d effectuer une interruption dessein Ne pas utiliser de cordon de prolongation sans conducteur de protection car ceci annulerait sa capacit de protection Lorsque l instrument est reli au secteur il est possible que les bornes soient sous tension et par suite l ouverture des couvercles ou la d pose de pi ces l exception de celles auxquelles on peut acc der manuellement risque de mettre d couvert des pi ces sous tension Il faut d brancher ke cordon secteur de
35. las alimentaciones el ctricas de precisi n de banca se conecta una capacitancia a trav s de la salida para mantener estabilidad y repuesta buena a tensiones de ondas transitorias Esta capacitance carga hasta la tensi n de salida y un cortocircuito de la salida producir un pulso de corriente mientras la capacitancia descarga el cual es independiente del l mite preajustado de la corriente Protecci n 30 La salida tiene protecci n intr nsica contra cortocircuitos y est protegida contra tensiones de polaridad invertida mediante un diodo La corriente continua al rev s no debe exceder 3 Amperios aunque las ondas transitorias pueden estar mucho superior a esto La salida est protegida contra tensiones directas aplicadas externamente de hasta 40V Operaci n Salida Auxiliar Tensi n de Salida La salida de voltaje puede ajustarse entre 1 5V y 5 0V mediante el bot n giratorio del panel frontal al lado de los terminales centrales Con el interruptor a la derecha de la salida principal en OFF pulsando el bot n SHOW AUX PRESET se visualizar el voltaje de salida AUX y el l mite de corriente en los medidores de la derecha L mite de Corriente El mecanismo de limitar la corriente de la salida entrar en acci n entre 5A y 6A se ilumina la l mpara UNREG no regulada en esta condici n Protecci n La salida tiene protecci n intr nsica contra cortocircuitos y est protegida contra tensiones de polaridad invertida me
36. lb der angegebenen Nennversorgungsspannungen oder Umgebungsbedingungen betreiben WARNUNG DIESES GER T MUSS GEERDET WERDEN Jede Unterbrechung des Netzschutzleiters innerhalb oder au erhalb des Ger tes macht das Ger t gef hrlich Eine absichtliche Unterbrechung ist verboten Die Schutzwirkung darf durch Verwendung eines Verl ngerungskabels ohne Schutzleiter nicht aufgehoben werden Ist das Ger t an die elektrische Versorgung angeschlossen so k nnen die Klemmen unter Spannung stehen was bedeutet da beim Entfernen von Verkleidungs oder sonstigen Teilen mit Ausnahme der Teile zu denen Zugang mit der Hand m glich ist h chstwahrscheinlich spannungsf hrende Teile blo gelegt weden Vor jeglichem ffnen des Ger tes zu Nachstell Auswechsel Wartungs oder Reparaturzwecken dieses stets von s mtlichen Spannungsquellen abklemmen Kondensatoren in der Stromversorgung k nnen auch noch nach Abschalten s mtlicher Stromversorgung Spannung f hren sie entladen sich jedoch innerhalb von etwa einer Minute nach Spannungsabschaltung Jegliche Nachstellung Wartung und Reparatur am ge ffneten unter Spannung stehenden Ger t ist nach M glichkeit zu vermeiden Falls unvermeidlich sollten solche Arbeiten nur von qualifiziertem Personal ausgef hrt werden das sich der Gefahren bewusst ist Ist das Ger t eindeutig fehlerbehaftet bzw wurde es mechanisch besch digt berm iger Feuchtigkeit oder chemischer Korrosion ausgesetzt so k
37. mVrms lt 10mVpk pk CV mode Transient Response lt 200us to within 50mV of set level for 90 load change Temperature Coefficient Typically lt 100ppm C Status Indication METER SPECIFICATIONS Main Outputs Output on lamp Constant current mode lamp Meter Types Meter Resolutions Meter Accuracies Voltage Meter Voltage Accuracy Current Limit Output Protection Load Regulation Line Regulation Ripple 8 Noise 20MHz bandwidth Transient Response Temperature Coefficient Status Indication GENERAL AC Input Power Consumption Operating Range Storage Range Environmental Safety EMC Size Weight Dual 3 digit meters with 14mm 0 56 LEDs Reading rate 4 Hz 100mV 10mA Voltage 0 3 of reading 1 digit Current 0 6 of reading 1 digit AUXILIARY LOGIC OUTPUT XPH 35 4T only Variable lt 1 5V to gt 5V by front panel control 0 3 1 digit 5A minimum Output will withstand up to 7V forward voltage Diode clamp reverse protection for currents up to 3A lt 0 5 for 90 load change lt 0 1 for 10 line voltage change Typically lt 2mVrms lt 10mVpk pk CV mode Typically lt 200us to within 50mV of set level for 90 load change Typically lt 100ppm C UNREG lamp 110V 240V AC 10 50 60Hz Installation Category II 500VA max 5 C to 40 C 20 to 80 RH 40 C to 70 C Indoor use at altitudes up to 2000m Pollution Degree 2 Compl
38. me anzuschlie en Die blaue Ader ist an die mit N markierte oder schwarzfarbene Klemme anzuschlie en Die braune Ader ist an die mit L markierte oder rotfarbene Klemme anzuschlie en WARNUNG DIESES GER T MUSS GEERDET WERDEN Jede Unterbrechung des Netzschutzleiters innerhalb oder au erhalb des Ger ts macht das Ger t gef hrlich Eine absichtliche Unterbrechung ist verboten Anschlusse S mtliche Anschl sse erfolgen von der Fronttafel aus Der Verbraucher sollte an die mit OUTPUT Ausgang markierte positive rot und negative schwarz markierte Klemme angeschlossen werden Die mit dem Symbol gekennzeichnete Klemme ist mit dem Chassis und der Schutzerde verbunden 19 Betrieb Hauptausgange Der Betrieb beider Hauptausg nge ist derselbe Folgende Beschreibung gilt daher f r beide Einstellung des Ausgangs Bei eingeschaltetem POWER Netzschalter I und ausgeschaltetem Ausgang l t sich die Ausgangsspannung und Strombegrenzung mit Hilfe der Kn pfe VOLTAGE Spannung und CURRENT Strom genau voreinstellen Die linke Anzeige zeigt die eingestellte Spannung und die rechte den eingestellten Maximalstrom an Ist der Ausgangsschalter aktiviert leuchtet die ON Ein Leuchte auf Jetzt wird auf der linken Anzeige die Istspannung und an der rechten Anzeige der Ist Laststrom angezeigt Konstantspannung Die Ausgangsspannung wird mittels der Grob coarse und Feindrehkn pfe fine von VOLTAGE reguliert M
39. mmen eines Ausgangs und einer beliebigen Klemme eines anderen Ausgangs desselben Ger ts betr gt ebenfalls 300V Gleichspannung WARNUNG Spannungen in dieser Gr enordnung sind beraus gef hrlich Bei einer solchen Einsatzweise sollten die Ausgangsklemmen mit gr ter Sorgfalt abgeschirmt werden Unter diesen Bedingungen d rfen die Ausgangsklemmen keinesfalls ber hrt werden wenn das Ger t eingeschaltet ist Wann immer Verbindungen mit den Klemmen hergestellt werden m ssen s mtliche Ger te ausgeschaltet sein Zu beachten ist dabei da das Ger t ausschlie lich stromliefernd nicht aber stromziehend arbeiten kann und da die Ger te daher nicht gegenphasig in Reihe geschaltet werden k nnen Das Ger t kann zur Erzeugung einer h heren Stromabgabe mit anderen Ger ten parallel zu diesen geschaltet werden Wenn mehrere Ger te parallel geschaltet werden entspricht die Ausgangsspannung der Ausgangsspannung des Ger ts bei dem der Einstellwert f r die Ausgangsspannung am h chsten ist bis die Stromaufnahme den bei diesem Ger t eingestellten Grenzwert berschreitet woraufhin der Ausgang auf die zweilh chste Einstellung abf llt und so weiter Im Konstantstrombetrieb k nnen Ger te parallel geschaltet werden wodurch sich eine Stromabgabe erreichen l t die der Summe der Einstellwerte f r die Strombegrenzung entspricht Ventilation Obwohl die Stromversorgung u erst effizient arbeitet kann sie bei voller Leistung ein b
40. o 2 entro la gamma di temperatura da 5 C a 40C con umidit relativa non condensante di 20 80 Pu occasionalmente essere assoggettato a temperature fra 5 C e 10 C senza comprometterne la sicurezza Non usare in presenza di condensazione L uso dello strumento in maniera non conforme a quanto specificato in queste istruzioni potrebbe pregiudicare la protezione di cui dotato Non usare lo strumento per misurare tensioni al di sopra dei valori nominali o in condizioni ambientali al di fuori di quelle specificate ATTENZIONE QUESTO STRUMENTO DEVE ESSERE COLLEGATO A TERRA Una qualsiasi interruzione sia interna che esterna del collegamento a terra rende pericoloso questo strumento E proibito interrompere questo collegamento deliberatamente L azione protettiva non deve essere negata dall uso di una prolunga priva conduttore di protezione Quando lo strumento collegato all alimentazione alcuni morsetti sono sotto tensione e l apertura dei coperchi o la rimozione di parti eccetto quei componenti accessibili senza l uso di attrezzi pu lasciare scoperti i morsetti sotto tensione Prima di aprirla per eseguire regolazioni manutenzione o riparazioni l apparecchiatura deve essere staccata da tutte le sorgenti di tensione condensatori collegati all alimentazione interna possono essere carichi anche dopo aver staccato l alimentazione ma si scaricano in circa 10 minuti dopo aver staccato la corrente Per quanto possibile
41. omer What will Xantrex do Xantrex will at its option repair or replace the defective product free of charge provided that you notify Xantrex of the product defect within the Warranty Period and provided that Xantrex through inspection establishes the existence of such a defect and that it is covered by this Limited Warranty Xantrex will at its option use new and or reconditioned parts in performing warranty repair and building replacement products Xantrex reserves the right to use parts or products of original or improved design in the repair or replacement If Xantrex repairs or replaces a product its warranty continues for the remaining portion of the original Warranty Period or 90 days from the date of the return shipment to the customer whichever is greater All replaced products and all parts removed from repaired products become the property of Xantrex Xantrex covers both parts and labor necessary to repair the product and return shipment to the customer via a Xantrex selected non expedited surface freight within the contiguous United States and Canada Alaska and Hawaii are excluded Contact Xantrex Customer Service for details on freight policy for return shipments outside of the contiguous United States and Canada How do you get service If your product requires troubleshooting or warranty service contact your merchant If you are unable to contact your merchant or the merchant is unable to provide service contact Xantre
42. on page 28 Payment options such as credit card or money order will be explained by the Customer Service Representative In cases where the minimum flat fee does not apply as with incomplete units or units with excessive damage an additional fee will be charged If applicable you will be contacted by Customer Service once your unit has been received 35 Xantrex Technology Inc 9250 Brown Deer Road San Diego CA USA 92121 858 450 0085 Tel 858 678 4481 Fax 800 733 5427 Toll Free North America sales programmablepower com service programmablepower com www programmablepower com 975 0101 01 04 48511 0990 Issue 2
43. ows the set voltage and the right hand meter shows the set maximum current When the output switch is switched ON the lamp lights the left hand meter now shows the actual voltage and the right hand meter the actual load current Constant Voltage The output voltage is adjusted using the coarse and fine VOLTAGE controls the CURRENT control sets the maximum current that can be supplied Constant Current If the load resistance is low enough such that at the output voltage set a current greater than the current limit setting would flow the power supply will automatically move into constant current operation The current output is adjusted by the CURRENT control and the VOLTAGE controls set the maximum voltage that can be generated The CC lamp lights to show constant current mode Instantaneous Current Output The current limit control can be set to limit the continuous output current to levels down to 10mA However in common with all precision bench power supplies a capacitor is connected across the output to maintain stability and good transient response This capacitor charges to the output voltage and short circuiting of the output will produce a current pulse as the capacitor discharges which is independent of the current limit setting Protection The output has intrinsic short circuit protection and is protected from reverse voltages by a diode the continuous reverse current must not exceed 3 Amps although transients can
44. prendre toutes les pr cautions d usage pour prot ger les bornes de sortie en cons quence Ne jamais toucher les bornes de sortie lorsque le bloc est allum pour ces applications Toutes les connexions des bornes doivent tre effectu es lorsque tous les blocs sont teints Il faut noter que le bloc peut uniquement recevoir du courant mais non le consommer de sorte qu il n est pas possible de mettre en opposition de phase les blocs reli s en s rie Il est possible de relier le bloc en parall le avec d autres afin de produire des courants de haute intensit Lorsque plusieurs blocs sont reli s en parall le la tension de sortie doit tre gale celle du bloc de r glage de tension de sortie le plus lev jusqu ce que le courant consomm d passe le r glage de limite de courant auquel cas la sortie descend celle du r glage le plus haut suivant etc En mode de courant constant les blocs peuvent tre reli s en parall le afin de donner un courant gal la somme des r glages de limite de courant Ventilation L alimentation est tr s performante mais elle peut toutefois g n rer beaucoup de chaleur puissance maximale L alimentation a besoin d un refroidissement par convection uniquement et il est donc important que la ventilation ne soit jamais r duite afin d assurer une bonne performance et s curit 16 Maintenance Le Constructeur ou ses agents l tranger r pareront tout bloc qui tombe en p
45. robado seg n la norma EN61010 1 y ha sido suministrado en una condici n segura El manual de instrucciones contiene informaci n y advertencias que deben aplicarse para garantizar la seguridad del usuario durante su empleo Este instrumento ha sido dise ado para ser utilizado en un ambiente Grado 2 de Poluci n a temperaturas de entre 5 C y 40 C y humedad relativa de entre el 20 y el 80 sin condensaci n De manera ocasional puede someterse a temperaturas de entre 10 C y 5 C sin que ello afecte a su seguridad No hay que ponerlo en funcionamiento mientras haya condensaci n El uso de este instrumento de forma no especificada por estas instrucciones puede afectar a su seguridad El instrumento no debe ser utilizado fuera de su rango de voltaje o de su gama ambiental ADVERTENCIA ESTE INSTRUMENTO DEBE CONECTARSE A TIERRA Cualquier interrupci n del conductor a tierra dentro o fuera del instrumento implicar a que el instrumento resultara peligroso Est prohibida cualquier interrupci n intencionada de la connexi n a tierra No debe utilizarse con un cable de tension sin tierra Mientras el instrumento est conectado es posible que queden sin protecci n elementos bajo tensi n y la obertura de tapas o el retiro de piezas salvo las accesibles por la mano pueden dejar expuestos a elementos bajo tensi n Si se tuviera que efectuar alguna operaci n de ajuste cambio mantenimiento o reparaci n es necesario desconectar el instrumen
46. ruption dessein Connexions Toutes les connexions sont effectu es au panneau avant Relier la charge aux bornes positive rouge et n gative noire marqu es OUTPUT Sortie La borne d sign e est reli e au ch ssis et la terre de protection Fonctionnement Sorties principales Le fonctionnement des deux sorties principales est identique la description suivante s applique aux deux R glage de la sortie Lorsque l interrupteur POWER alimentation est en position I et la sortie est en position OFF teinte il est possible de r gler avec pr cision la limite de tension et de courant de sortie au moyen des commandes VOLTAGE Tension et CURRENT Courant l appareil de mesure gauche indique la tension r gl e et l appareil droit le courant maximum r gl Lorsque le commutateur de sortie est en position ON marche le t moin s allume l appareil de mesure gauche indique alors la tension v ritable et l appareil droit le courant de charge v ritable Tension constante Les commandes VOLTAGE de r glage grossier et de pr cision permettent d ajuster la tension de sortie la commande CURRENT r gle le courant maximum qui peut tre fourni Courant constant Si la r sistance de charge est suffisamment basse qu un courant sup rieur au r glage de limite de courant puisse passer pour la tension de sortie r gl e l alimentation passera automatiquement en mode de fonctionnement de courant constant
47. s closest to the internal sense connection and the load plugged in to the 4mm sockets of the terminals Adjust VR9 109 differential voltage gain until the external DMM matches the previous reading exactly 1 5V 5V Output Connect the DMM to the output Use the front panel control to adjust the output to 5 0x Volts With the right hand Main output OFF press the SHOW AUX PRESET button to display the AUX OUT voltage adjust VR1 on the 1 5V 5V pcb until the display reads 5 0V Connect the DMM set to Amps and load in series across the output Adjust load until the UNREG LED comes ON Check that the DMM reads gt 5 Amps Connect the DMM set to Volts in parallel with the load across the output Adjust load until the UNREG LED just goes off Check that the DMM reads the same as in the 5V check above 0 025V 11 Fuse Maintenance The Manufacturers or their agents overseas will provide repair for any unit developing a fault Where owner wish to undertake their own maintenance work this should only be done by skilled personnel in conjunction with the service manual which may be purchased directly from the Manufacturers or their agents overseas The correct fuse type is 10 Amp 250V HBC time lag T 5 x 20mm Note that the main function of the fuse is to make the instrument safe and limit damage in the event of failure of one of the switching devices If a fuse fails it is therefore very likely that the replacement will also blow becau
48. scende al valore dell impostazione pi alta immediatamente inferiore e cos via In modalit di corrente costante vari gruppi possono essere collegati in parallelo per erogare una corrente uguale alla somma dei limiti di corrente impostati Ventilazione 26 Il dispositivo di alimentazione molto efficiente ma a piena potenza pu generare una quantit significativa di calore Il raffreddamento per convezione ed perci importante che la ventilazione non sia mai ristretta se si vogliono mantenere i livelli ottimali di rendimento e sicurezza Se il dispositivo montato in uno spazio ristretto ad es su una rastrelliera da 19 pollici si deve provvedere una ventilazione adeguata usando ad esempio una base fornita di ventola Manutenzione Produttori o i loro agenti all estero faranno le riparazioni necessarie in caso di guasto Qualora l utente desiderasse eseguire il lavoro di manutenzione tale lavoro deve essere fatto solo da personale qualificato e usando il manuale di servizio che pu essere acquistato direttamente dai Produttori o dai loro agenti all estero Fusibili Il tipo di fusibile corretto 10 Amp 250V ritardato T HBC 5 x 20mm da notare che la funzione principale del fusibile di rendere sicuro lo strumento e limitare i danni qualora si guasti uno dei propri dispositivi di commutazione Se si guasta un fusibile sar pertanto molto probabile che salti anche il fusibile di ricambio in quanto si
49. se the supply has developed a fault in such circumstances the instrument will need to be returned to the manufacturer for service Make sure that only fuses of the required rated current and specified type are used for replacement The use of makeshift fuses and the short circuiting of fuse holders is prohibited To replace a fuse first disconnect the instrument from the AC supply Remove the 7 cover securing screws and lift off the cover Replace the fuse with one of the correct type and refit the cover Cleaning 12 If the PSU requires cleaning use a cloth that is only lightly dampened with water or a mild detergent Polish the display window with a soft dry cloth WARNING TO AVOID ELECTRIC SHOCK OR DAMAGE TO THE PSU NEVER ALLOW WATER TO GET INSIDE THE CASE TO AVOID DAMAGE TO THE CASE OR DISPLAY WINDOW NEVER CLEAN WITH SOLVENTS S curit Cet instrument est de Classe de s curit 1 suivant la classification IEC et il a t construit pour satisfaire aux imp ratifs EN61010 1 imp ratifs de s curit pour le mat riel lectrique en vue de mesure commande et utilisation en laboratoire Il s agit d un instrument d installation Cat gorie Il devant tre exploit depuis une alimentation monophas e habituelle Cet instrument a t soumis des essais conform ment EN61010 1 et il a t fourni en tout tat de s curit Ce manuel d instructions contient des informations et avertissements qui doivent tre suivis par
50. spannung kann mittels Drehkopf neben den zentralen Anschlussklemmen in einem Bereich von 1 5 V bis 5 0 V eingestellt werden Ist der rechte Hauptausgang ausgeschaltet kann durch dr cken der SHOW AUX PRESET Taste die eingestellte Spannung und Strombegrenzung f r den Hilfsausgang in den beiden rechten Anzeigen zu Ansicht gebracht werden Strombegrenzung Zwischen 5 und 6 A erfolgt die Strombegrenzung des Ausgangs Unter diesen Bedingungen leuchtet die Leuchte UNREG ungeregelt auf Schutzvorrichtungen Der Ausgang ist mit einem eigenen Kurzschlu schutz versehen und mittels Diode vor Umkehrspannungen gesch tzt Kontinuierlicher Umkehrstrom darf 3 Amp nicht berschreiten Transiente Str me k nnen jedoch wesentlich h her liegen Der Ausgang ist vor extern angelegten Durchla spannungen von bis zu 7V Betrieb Allgemein Verbraucheranschlu Der Verbraucher ist an die positive rote und negative schwarze Ausgangsklemme anzuschlie en Bei beiden Anschl ssen handelt es sich um vollkommen potentialfreie die jeweils geerdet werden k nnen Reihen und Parallelschaltung mit anderen Ausg ngen Da der Ausgang des Netzteils vollst ndig potentialfrei ist kann er mit anderen Netzger ten zur Erzeugung hoher Gleichspannungen bis maximal 300V in Reihe geschaltet werden Die maximal zul ssige Spannung zwischen einer beliebigen Klemme und Erde betr gt 300V Gleichspannung Die maximal zul ssige Spannung zwischen einer der beiden Kle
51. st temporary degradation or loss of function or performance which is self recovering Performance criterion C During test temporary degradation or loss of function or performance which requires operator intervention or system reset occurs Where Performance B is stated it is because DC Output regulation may deviate beyond Specification limits under the test conditions However the possible deviations are still small and unlikely to be a problem in practice Note that if operation in a high RF field is unavoidable it is good practice to connect the PSU to the target system using screened leads which have been passed together through an absorbing ferrite sleeve fitted close to the PSU terminals Cautions To ensure continued compliance with the EMC directive observe the following precautions a after opening the case for any reason ensure that all signal and ground connections are remade correctly and that case screws are correctly refitted and tightened b In the event of part replacement becoming necessary only use components of an identical type see the Service Manual Safety This power supply is a Safety Class instrument according to IEC classification and has been designed to meet the requirements of EN61010 1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use It is an Installation Category Il instrument intended for operation from a normal single phase supply This instrum
52. t controls to minimum Switch output ON Check LED is on and check for a reading of 00 0V 0 1V on the Volts display and DMM check the Amps display reads 0 00 0 01A Set voltage and current controls to maximum Adjust VR5 VR105 maximum output volts for a reading of 35 16V to 35 24V on the DMM Adjust VR6 VR106 measured output volts until the Volts display matches the reading on the external DMM Switch output OFF Adjust VR10 110 preset volts until the Volts display shows 35 2 Current Calibration Switch output OFF Set output voltage to nominally 2V Set current control to minimum Connect the DMM set to Amps and load in series across the output Switch output ON Adjust VR8 108 offset compensation of current control error amp for a reading of 0 003A 001A on the DMM Check that the CC LED is ON Increase voltage controls and current control to maximum Adjust load until the DMM reads 4 00A 0 02A Adjust VR7 107 measured output current until the Amps display matches the DMM reading Reduce load until the CC LED is ON Adjust VR4 104 maximum output current until the Amps display shows 4 05 Voltage Regulation Connect the DMM set to Volts across the output no load output ON Adjust voltage controls for a reading of 18 xxxx on the DMM note exact reading Connect load set current control to maximum and adjust load for 4A output current Note that the DMM should be connected at the back of the output terminal
53. the board it is necessary to remove the top cover WARNING When the instrument is connected to its supply the removal of covers is likely to expose live parts The instrument should be disconnected from all voltage sources before it is opened for any adjustment replacement maintenance or repair Capacitors inside the power supply may still be charged even if the power supply has been disconnected from all voltage sources but will be safely discharged about 5 minutes after switching off power Any adjustment maintenance and repair of the opened instrument under voltage shall be avoided as far as possible and if inevitable shall be carried out only by a skilled person who is aware of the hazard involved Remove the 6 side screws and the front handle screw to release the top cover Component adjustment references are given as Channel A Channel B e g VR5 VR105 Channel A is the left hand output VR110 O O vr10 O O VR4 VR104 VERDE VRS VR107 O VR7 O O VRS vha O vrs vR109 O O O VR108 O VR106 Control pcb calibration points viewed from rear Equipment Required A 5 digit multimeter with better than 0 05 accuracy on dc volts and better than 0 1 accuracy on dc current to 5A alternatively use a precision shunt for current measurement Rheostat or other high power load arrangement to provide up to 5A load at 35V Voltage Calibration 10 Connect the DMM set to Volts across the output Set voltage and curren
54. to de todas las fuentes de tensi n Los capacitores dentro del aparato pueden permanecer cargados a n cuando las fuentes de tensi n hayan sido desconectadas pero quedar n seguramente descargadas a 10 minutos de haber desconectado la corriente Todo ajuste mantenimiento o reparaci n del instrumento abierto bajo tensi n debe ser evitado en lo posible pero si fuera ineludible estos trabajos deben ser realizados exclusivamente por un personal cualificado consciente del riesgo que implican Si el instrumento fuera claramente defectuoso hubiera sido sometido a un da o mec nico a humedad excesiva o a corrosi n qu mica su protecci n de seguridad puede fallar y el aparato debe sacarse de uso y devolverse para comprobaci n y reparaci n Aseg rese que s lo se empleen fusibles de la clasificaci n y tipo especificados para todo recambio Est prohibido utilizar fusibles improvisados as como el corto circuito de portafusibles El instrumento no debe humedecerse al ser limpiado Los s mbolos a continuaci n son utilizados en el instrumento y en este manual Terminal a tierra alimentaci n principal ON conectada Corriente cont nua cc O alimentaci n principal OFF desconectada Ny corriente alterna ca Instalaci n Tensi n de la Red El ctrica Este instrumento tiene un rango de entrada universal y funcionar sin necesidad de ajustes en suministros el ctricos de 115V o 230V Compruebe que el suministro local sat
55. un fusible entonces es muy probable que el repuesto tambien se fundir porque se ha desarrollado una aver a en la alimentaci n el ctrica en tales circunstancias ser necesario devolver el instrumento al fabricante para una revisi n Asegurar que se empleen s lo fusibles de la clasificaci n y del tipo especificado para todo recambio Est prohibido utilizar fusibles improvizados as como el cortocircuito del portafusibles Para cambiar un fusible primero desconectar el instrument de la alimentaci n el ctrica de CA Quitar los 7 tornillos que sujetan la tapa y alzar la tapa Reemplazar el fusible con uno del tipo correcto y volver a colocar la tapa Limpieza 32 Si la unidad de suministro de fuerza necesita ser limpiada utilizar un pa o brevemente humedecido en agua o en un detergente suave La ventana de visualizaci n debe lustrarse con un pa o suave y seco ADVERTENCIA PARA EVITAR CHOQUES ELECTRICOS O DA AR A LA UNIDAD DE SUMINISTRO DE FUERZA NUNCA DEJE ENTRAR AGUA AL ENVASE PARA EVITAR QUE EL ENVASE O LA VENTANA DE VISUALIZACION SEAN DA ADOS NUNCA LIMPIE CON SOLVENTES Warranty Information Warranty What does this warranty cover This Limited Warranty is provided by Xantrex Technology Inc Xantrex and covers defects in workmanship and materials in your XPH series This warranty lasts for a Warranty Period of three years 3 years from the date of purchase at point of sale to you the original end user cust
56. verificato un malfunzionamento nell alimentazione In queste circostanze lo strumento deve essere restituito al produttore per la riparazione Per la sostituzione accertarsi che vengano usati fusibili del tipo e della corrente nominale specificati E proibito usare fusibili di ripiego o cortocircuitare i portafusibili Per sostituire un fusibile scollegare prima lo strumento dall alimentazione CA Rimuovere le 7 viti di fissaggio del coperchio e sollevare quest ultimo Sostituire il fusibile con un fusibile di tipo corretto e riporre il coperchio Pulizia Se si deve pulire il dispositivo di alimentazione usare uno strofinaccio appena bagnato con acqua o con un detergente neutro Pulire la finestrella di visualizzazione con un panno asciutto e morbido ATTENZIONE PER EVITARE SCOSSE ELETTRICHE ED EVENTUALI DANNI AL DISPOSITIVO DI ALIMENTAZIONE NON PERMETTERE MAI ALL ACQUA DI ENTRARE ALL INTERNO DELL ALLOGGIAMENTO PER EVITARE DANNI ALL ALLOGGIAMENTO E ALLA FINESTRELLA DI VISUALIZZAZIONE NON PULIRE MAI CON SOLVENTI 27 28 Seguridad Este es un instrumento de Clase de Seguridad seg n la clasificaci n del IEC y ha sido dise ado para cumplir con los requisitos del EN61010 1 Requisitos de Seguridad para Equipos El ctricos para la Medici n Control y Uso en Laboratorio Es un equipo de Categor a de Instalaci n Il que debe ser usado con un suministro monof sico normal Este instrumento se suministra habiendo sido comp
57. x directly at Phone 1 800 733 5427 toll free 1 858 450 0085 direct Fax 1 858 678 4481 Email service programmablepower com Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual For some products Xantrex maintains a network of regional Authorized Service Centers Call Xantrex or check our website to see if your product can be repaired at one of these facilities In any warranty claim dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex Proof of purchase may be in any one of the following forms e The dated purchase receipt from the original purchase of the product at point of sale to the end user or e The dated dealer invoice or purchase receipt showing original equipment manufacturer OEM status or e The dated invoice or purchase receipt showing the product exchanged under warranty 33 What does this warranty not cover This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal installation or troubleshooting of the customer s electrical systems This warranty does not apply to and Xantrex will not be responsible for any defect in or damage to a the product if it has been misused neglected improperly installed physically damaged or altered either internally or externally or damaged from