Home
Xantrex SW Communications Adapter User's Manual
Contents
1. 2002 Xantrex Technology Inc 10 P N 973 0022 01 01 RevA 04 2002 3 0 OPERATION The SWCA Programming Menu Function Keys Programming features are accessed by pressing ALT P and by using the function keys as described in Table 3 1 Purpose Changes SWCA ID number from the default of 1 to any number up to 8 After changing the ID number write the adapters new ID number on the outside of the adapter s gray housing to make later identification of the adapter easier Changes the adapter s configuration code This alters the operation of the adapter Do not change this code from the default value of 06 For typing in any text string to allow later identification of the adapter Type in desired information and press lt Enter gt ECS Leaves the programming menu Table 3 1 The SWCA Programming Menu NOTE Ifthe program does not find an adapter it indicates a TIMEOUT ERROR Check the adapter and cable for proper connection and retry the program 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev 04 2002 11 3 0 OPERATION LED Control Indicators The codes indicate the status of the inverter s LEDs The two letter codes are as follows Abbreviation Definition Over Current Table 3 2 LED Control Indicator Definitions If no codes display it is because there are no LEDS on or the adapter is not responding NOTE LED is flashing it may not appear each time you pressed 1 bec
2. 4 225 SI JOJONPUOD uo spuedep 38 LSNW Sele x Y i s poarts 1 7 Ez d i SEL Buipoo 10 oo pue sjueuuuBisse uid jo 10 ez z ainBi4 ees gt i Jejdepy leuas Buipoo 19Joo pue uid jo 104 27 7 eiun i4 ees gt VOMS MBA euoudoje3 Lry arewa smoys SNOLLVTIV LSNI H3 LH3ANI F1dILINW NI SVOMS Installation Concerns continued Figure 2 2 SWCAs in Multiple Inverter Installations 2002 Xantrex Technology Inc P N 973 0022 01 01 RevA 04 2002 2 0 INSTALLATION BLACK YELLOW RED GREEN GREEN RED YELLOW BLACK Depending on the Cable Installation Figure 2 2a Enlargement of Pin Assignments and Color Coding on Custom made Serial Port Adapter BLACK YEL
3. Virtual Control Panel Trace SW Series Front Panel Simulator DOS Version 1 05 27 19 98 Set Inverter AC1 GOOD OFF SRCH ON CHG FLOAT ADAPTER 3 COM PORT 1 MENU ITEM SET POINTS MENU HEADINGS GEN ON OFF AF2A VF3V AF4A vr5v AF6A F7 F8 c 1996 98 TRACE ENGINEERING INC Arlington WA USA 360 435 8826 Figure 3 1 Virtual Display using DOS emulation program The DOS software program allows an IBM compatible personal computer to operate as a virtual control panel for up to eight SW series inverter chargers As shown in Figure 3 1 the function keys on the computer are the key to operating the inverter using the software They act as the up and down arrow keys for each different function of the inverter just as the up and down arrow keys do on the inverter The screen graphically displays which keys perform which functions Since the display mimics the inverter operation is very easy for anyone already familiar with the SW series controls Ks NOTE If the adapter is plugged into the inverter after the inverter is already on the computer LCD display may be blank until a key is pressed on the computer or the inverter itself The textual LED indicators on the computer will work normally If you are new to the SW series inverters reading the owner s manual in full will ensure getting the most from the system To the right of the LCD d
4. Data bits 8 Parity No or None Stop Bits 1 Flow control Either setting NOTE These are the only acceptable values Properties __ Figure 3 5 COMI Properties Click OK and a blank window opens 2002 Xantrex Technology Inc 18 P N 973 0022 01 01 RevA 04 2002 3 0 OPERATION TESTING THE SWCA In order to test the SWCA it must be plugged it into an inverter that is powered up on batteries or a suitable power supply Press the number 1 If everything is correct the inverter should reply with a UNIT1 and possibly some two character codes 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev 04 2002 19 3 0 OPERATION 02002 Xantrex Technology Inc 20 P N 973 0022 01 01 Rev 04 2002 4 0 TROUBLESHOOTING Symptom Recommendation 1 Check the ID number of the adapter you are trying to access Ensure itis correct This will display when there is no adapter with the ID number you are entering 2 Check the connection from the adapter to the remote Display reads port ADAPTER OFFLINE 3 Check the connection from the COM Port to the This is displayed when remote port running the DOS display emulation program when 4 Check the LED on the SWCA Adapter there is no adapter response illuminates when connected to the inverter s remote port then the adapter is recognized does not illuminate when connected to the inverter s remote port then the adapter is malfunctioning
5. NOTE This statement is important Follow instructions closely NOTE Cette d claration est importante Suivre les instructions de pr s e All electrical work must be done in accordance with local national and or international electrical codes Before installing or using this device read all instructions and cautionary markings located in the manual and on the inverter the batteries and the PV array Do not expose this unit to rain snow or liquids of any type This product is designed only for indoor usage This product contains no user serviceable parts Do not attempt to repair this unit 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev 04 2002 Table of Contents IMPORTANT SAFETY 1 5 iii 1 0 INTRODUCTION vossen iure etx envio epus do 1 2 0 INSTALLATION riae to iens ida 3 the 5 eor 6 53 Connecting the SWCA to a Computer using a Modem Assdulicse M 4 Additional Possible Requirements sss 4 Connecting Multiple SWCAs to a Single 4 Advanced Monitoring Software 5 Installation Concerns 5 M ltiple SWEA S teri etie 145 Positive Ground or PV Ground Fault Protection Installations 2 5 Installing the SWCPS DOS Progratm ssccccsss
6. PORT on the SW inverter charger TO INSTALL THE SWCA 1 Connect the SWCA adapter to the SW series inverter charger remote port located on the left end of the inverter near the AC wiring compartment NOTE There are two ports located on the inverter one is used for the stacking cable and the other is for the remote control port Make sure you connect the SWCA to the correct port If a SW series remote control is being used it will have to be disconnected while the SWCA is in use 2 Connect the phone cable to the phone jack on the gray SWCA housing and to the black serial port adapter 3 Plug the serial port adapter into the computer serial port Fs NOTE On some computers a DB9 to DB25 adapter may be needed to allow connection ecc Ed aa T Bass Ecco Figure 2 1 SW Inverter Charger Remote Port Location Es NOTE The location of the REMOTE PORT may vary slightly depending upon the model of SW inverter charger being used All models should be labeled however to simplify the identification and location of the port 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 3 2 0 INSTALLATION Connecting the SWCA to a Computer using a Modem The SWCA can be connected directly to a modem for use in remote sites where a computer may not be available Reguirements To use a modem the following is reguired e at terminal emulation program See SECTION 3 0 OPERATION Use of
7. the inverter s LED indicators are displayed Any active LEDs are displayed by the label description of the LEDs function being shown If the LED is flashing on the inverter then the label description of the LED will also flash on the control panel simulator Since the same menu system is used with the control panel simulator as with the inverter itself the operation of the SWCA will be familiar to anyone who has programmed a SW series inverter charger system The only difference is the use of the function keys instead of the buttons The SWCA Programming Menu The SWCA Programming Menu provides the means to change the SWCA ID number or for changing the adapter s configuration code It also provides the means for applying a textual identification labels Below the LCD display on the computer version the word ADAPTER appears This shows which inverter is being accesssed To access the different inverters simply enter the ID number of the inverter 1 8 that you want to control by using the computer s numeric keys Sine Wave Communications Memory Adapter PROGRAMMING MENU Adapter ID Number 3 Configuration A 06 Configuration B 00 Serial Number 0000 0000 1015 Software ID SWCA Ver1 01 7 087 lt Fi gt New Adapter ID F2 Neu Configuration lt F3 gt New Customer ID 98 Customer ID STATUS OK Press lt ESC gt to return to SM Front Panel Simulation Figure 3 2 SWCA Programming Menu Display
8. LOW RED GREEN GREEN RED YELLOW BLACK gt Depending on the Cable Installation Figure 2 2b Enlargement of Pin Assignments and Color Coding for 25 foot 4 conductor telephone standard Cable BLACK YELLOW RED GREEN GREEN RED YELLOW BLACK ola p fo lr Depending on the Cable Installation Figure 2 2 Enlargement of Pin Assignments and Color Coding on SWCA Adapter 2002 Xantrex Technology Inc P N 973 0022 01 01 RevA 04 2002 7 2 0 INSTALLATION INSTALLING THE SWCPS DOS PROGRAM A control panel simulation software program included on the floppy disk allows an IBM compatible personal computer to operate as a virtual control panel for up to eight SW series inverter chargers For other computer platforms See SECTION 3 0 OPERATION Use of the HE SWCA with Terminal Emulation Programs on page 9 To install the software insert the floppy disk into your computer floppy drive and copy the file swcps exe from the floppy disk provided to the hard disk on the computer Remember the location of this file on the hard disk for later reference Alternately the program can be run directly from the floppy disk 2002 Xantrex Technology Inc 8 P N 973 0022 01 01 Rev 04 2002 3 0 OPERATION USING THE SWCPS DOS PROGRAM This section describes the operation of the SWCPS DOS program SWCA DOS Display Emulation Software
9. WCA code only manipulates the inverter s display or remote SWRC keypad strokes The included DOS software emulates these keystrokes There are companies that have used these keystroke s bits of information coming out of the SWCA to develop advanced monitoring software This software can provide monitoring and data logging capability Additional information on these programs can be found at www righthandeng com or www mauisolarsoftware com NOTE Xantrex Technology Inc assumes responsibility for the use or function of these advanced monitoring software programs INSTALLATION CONCERNS Multiple SWCAs If using multiple SWCAs and multiple inverters the green wire must be isolated from each other as shown in Figure 2 2 on page 6 NOTE This could be a red wire depending on the cable installation from the SWCA Positive Ground or PV Ground Fault Protection Installations When using the SWCA in inverter installations that have DC ground fault protection PVGFP or where the inverter is connected in a positive ground configuration it is recommended that an opto isolator be connected somewhere between the SWCA and the computer com port Opto isolators can be obtained through www blackbox com part SP400A R3 and PS576 9Vdc power supply 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 5 2 0 INSTALLATION Bulpoo Jojoo pue uid 20 qz z
10. and needs to be replaced Data via modem is not Ensure the BAUD rate for the modem and the dial up recognizable program is fixed at 9600 Run the DOS emulation program to determine if the Modem is not connecting adapter is functioning and all connections to the adapter are correct Table 4 1 Troubleshooting the SWCA 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 21 4 0 TROUBLESHOOTING 02002 Xantrex Technology Inc 22 P N 973 0022 01 01 Rev A 04 2002 APPENDIX A PRODUCT AND SYSTEM INFORMATION WARRANTY Xantrex Technology Inc warrants its power products against defects in materials and workmanship for a period of two 2 years from the date of purchase established by proof of purchase or formal warranty registration and extends this warranty to all purchasers or owners of the product during the warranty period Xantrex does not warrant its products from any and all defects e arising out of material or workmanship not provided by Xantrex or its Authorized Service Centers when the product is installed or exposed to an unsuitable environment as evidenced by generalized corrosion or biological infestation resulting from abnormal use of the product alteration or use in violation of the instructions in components parts or products expressly warranted by another manufac turer Xantrex Technology Inc agrees to supply all parts and labor to repair or replace defects covered by t
11. ation Policy Return Material Procedure IMFOMMALION nmi errem bon eni er E teen TEE EE OE 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 vi Figure 1 1 Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure 2 1 2 2 2 2a 2 2b 2 2c 3 1 3 2 3 3 3 4 3 5 List of Figures SW Communications Adapter SWCA 1 SW Inverter Charger Remote Port Location 3 SWCAs in Multiple Inverter Installations 6 Enlargement of Pin Assignments and Color Coding on Custom made Serial Port Adapter 7 Enlargement of Pin Assignments and Color Coding for 25 foot 4 conductor telephone standard Cable 7 Enlargement of Pin Assignments and Color Coding or SWCA Adapter scere tete be a E 7 Virtual Display using DOS Emulation Program 9 SWCA Programming Menu 10 Making a New Connection 16 Telephone Number Dialog 17 Com T Properties ooo ias 18 2002 Xantrex Technology Inc P N 973 0022 01 01 RevA 04 2002 List of Tables Table 3 1 The SWCA Programming Menu 11 Table 3 2 LED Control Indicator Definitions s
12. ause it was not illuminated when the SWCA sent the data to the computer A flashing o LED should be indicated by the LED two letter code being repeated on the display 2002 Xantrex Technology Inc 12 P N 973 0022 01 01 RevA 04 2002 3 0 OPERATION Keyboard Commands The following keystrokes enable navigation through the menus and provide the means to change available settings Keystroke Function Select inverter 1 through 8 is the inverters ID number 1 is the default Menu Headings Menu Headings Menu Itme towards top Menu towards bottom Set Point lower value Set Point higher value Inverter On OFF Menu same as the RED button on the inverter control panel Generator On OFF Menu G same as the GREEN button on the inverter control Setup Menu lt Ctrl gt lt S gt same as pushing Generator and On OFF Menu at the same time Version number of SWCA Set terminal mode 3 If you see lots of strange characters display trying pressing T for terminal mode Table 3 3 Keyboard Commands for using Terminal Emulation Programs 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 13 3 0 OPERATION Starting the Program From Windows 1 Open MY COMPUTER or WINDOWS EXPLORER 2 Locate the file swcps exe and double click it or 1 Click START 2 Select RUN 3 Type swcps and press lt Enter gt From DOS or a DOS prompt within Windows 1 Locate the file sw
13. cps exe 2 Type swcps and press lt Enter gt When the program starts a line drawing of the SW series control panel will appear on the computer screen You can resize the MSDOS window for better viewing of the control panel if the labeling is not clear ID Numbers Once the program has started it looks for an SWCA programmed with an ID number of 1 This is the default ID number of all adapters If two adapters are connected to a PC with the same ID number you will not be able to communicate with either until the adapters have different ID numbers Refer to Table 3 1 on page 11 for information on accessing the SWCA Programming Menu to reprogram the adapters with a different ID number The program also assumes that the SWCA is connected to a serial port with a COM number of 1 If you are using a COM port other than one refer to the paragraph in this section titled Changing the PC s COM Port Number Changing the PC s COM Port Number To change the COM port number that the control panel simulator DOS program uses to find the adapter add the COM port ID number 1 4 after the DOS command used to start the SWCPS program as follows C gt SWCPS 2 This command causes the program to look at the COM 2 port on the PC for the SWCA adapters 2002 Xantrex Technology Inc 14 P N 973 0022 01 01 Rev A 04 2002 3 0 OPERATION Accessing HELP Information from the SWCPS Program Help is available while using the SWCPS progra
14. e of your choice 2 Enter SWCA in the Name location 3 Select the desired icon 4 Click OK Connection Description 2 ay New Connection Enter and choose an icon for the connection Name SWEA loon Figure 3 3 Making a New Connection 2002 Xantrex Technology Inc 16 P N 973 0022 01 01 RevA 04 2002 3 0 OPERATION Use ofthe SWCA with Terminal Emulation Programs continued Establishing the Connection 1 2 3 Enter Country code e g United States of America 1 Enter Area code e g 360 Enter Phone Number e g 435 8826 For connections to the SWCA with a cable select Direct to COM1 If you are using a port other than choose the com port you are using For connections to the SWCA with a modem select xxx Bps Data Fax Modem where xxx is the transmission speed of the modem being used Click OK Phone Number 2 Enter details for the phone number that you want to dial County code United States of America 1 Area code 360 Phone number Connect using 14 4 Bps Data Fax Modem Direct to Com 1 Direct to Com 2 Direct to Com 3 Figure 3 4 Telephone Number Dialog Box 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev 04 2002 17 3 0 OPERATION COM Port Values You need to enter the following values for the COM port as shown in Figure 3 5 Bits per second 9600 BAUD
15. esvescsosssecssesseavesescsessestenecaseoses 8 3 0 OPERATION eio one dea als eee sa zip sen ebek 9 Using the SWCPS DOS Program tr retine 9 SWCA DOS Display Emulation Software Virtual Control Panel Function Keys and Other Displays 10 The SWCA Programming 10 The SWCA Programming Menu Function Keys n LED Control ette ee ia etes 12 Keyboard Command S 2 13 Starting the Program 14 ID ertt iners 14 Changing the PC s COM Port Number 14 Accessing HELP Information from the SWCPS Program 15 Accessing the SETUP MENU from the SWCPS Program 15 Switching Between Multiple SWCA Adapters inverters 15 Exiting the SWCPS 15 Use of the SWCA with Terminal Emulation Programs Making a New Connection Telephone Number 17 Port tet e toto eb bn Gad odere 18 19 4 0 TROUBLESHOOTING t sa 21 2002 Xantrex Technology Inc iv P N 973 0022 01 01 Rev 04 2002 Table of Contents continued APPENDIX A PRODUCT AND SYSTEM INFORMATION A 1 War arty aeiee Return Material Authoriz
16. his warranty with parts or products of original or improved design at the company s option Xantrex Technology Inc also reserves the right to improve the design of its products without obligation to modify or upgrade those previously manufactured Defective products must be returned to Xantrex Technology Inc or its Authorized Service Center in the original packaging or equivalent The cost of transportation and insurance on items returned for service is the responsibility of the customer Return transportation UPS Ground or equivalent as well as insurance on all repaired items is paid by Xantrex Technology Inc All remedies and the measure of damages are limited to the above Xantrex Technology Inc shall in no event be liable for consequential incidental contingent or special damages even if Xantrex Technology Inc has been advised of the possibility of such damages Any and all other warranties expressed or implied arising by law course of dealing course of performance usage of trade or otherwise including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited in duration for a period of two 2 years from the original date of purchase Some states or countries do not allow limitations on the term of an implied warranty or the exclusion or limitation of incidental or consequential damage which means the limitations and exclusions of this warranty may not apply to you Even tho
17. isplay is a representation of the inverter s LED lighted status indicators All status functions shown by the inverter s LED s are displayed on the screen The only difference is that the computerized display does not show the status lights it shows words that represent each function When an LED status light on each unit is flashing the word or words on the computer version will flash also 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 9 3 0 OPERATION Function Keys and Other Displays On the virtual control panel simulation the buttons of the real control panel have been replaced with labels shown as F1 through F10 These refer to the function keys of the computer keyboard which are located either above or next to the main keyboard area Each function key is associated with a specific inverter operation Pressing the appropriate function key causes the display on both the inverter and the PC screen to change accordingly The virtual control panel also shows the LCD display window on the inverter s control panel This will show the same information that is available at the inverter When no adapter is available the text ADAPTER OFFLINE appears When an SWCA has been successfully connected the LCD display window of the control panel simulator shows what is displayed on the inverter LCD display e g adapter 3 To the right of the LCD display area on the control panel simulator is an area where the status of
18. m by pressing F10 on the computer keyboard To leave the help screen press the ESC key to return to control panel simulation program Accessing the SETUP MENU from the SWCPS Program To access the inverter SETUP MENU press ALT F8 together This feature is available for inverters with Rev 4 01 and higher software versions To leave the SETUP MENU press F7 which returns you to the SET INVERTER main menu display Switching Between Multiple SWCA Adapters inverters To select another inverter simply press the number key for the SWCA adapter that was programmed in and written on the outside of the adapter as previously discussed Use numbers from 1 to 8 Exiting the SWCPS Program To exit the SWCPS program press ALT X You can also use the ESC key to guit as well 02002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 15 3 0 OPERATION USE OF THE SWCA WITH TERMINAL EMULATION PROGRAMS Modem connection reguires the use of a terminal emulation program as described in the following sections A modem is reguired at both the inverters and at the computer with a phone line available to make the connection The SW Communications Adapter SWCA supports use with terminal emulation programs Any computer that has available serial communications port and terminal emulation software can communicate with the SW series inverter using a cable and modem connection Making a New Connection 1 Start the terminal emulation softwar
19. rough product updates photographs and or illustrations used in this manual may not exactly match your unit Xantrex Technology Inc reserves the right to update this product without notice or releasing an updated manual when fit form or function are not affected Date and Revision April 2002 Revision A Part Number 973 0022 01 01 Contact Information Web www xantrex com Email dpm xantrex com Phone 360 435 8826 Fax 360 435 2229 2002 Xantrex Technology Inc ii P N 973 0022 01 01 Rev A 04 2002 IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of this product To reduce the risk of electrical shock and to ensure the safe installation and operation of this product the following safety symbols have been placed throughout this manual to indicate dangerous conditions and important safety instructions WARNING A DANGEROUS VOLTAGE OR CONDITION EXISTS IN THIS AREA USE EXTREME CAUTION WHEN PERFORMING THESE TASKS AVERTISSEMENT UNE TENSION OU CONDITION DANGEREUSE EXISTE DANS CETTE ZONE FAIRE PREUVE D EXTREME PRUDENCE LORS DE LA REALISATION DE CES TACHES CAUTION This procedure is critical to the safe installation or operation of the unit Follow these instructions closely ATTENTION Cette proc dure est essentielle a l installation ou l utilisation de l unit en toute s curit Suivre ces instructions de pr s
20. ss 12 Table 3 3 Keyboard Commands for using Terminal Emulation Programs coin etna 14 Table 4 1 Troubleshooting the SWCA sss 21 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 vil 02002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 1 0 INTRODUCTION The Sine Wave Communications Adapter SWCA allows any SW series inverter charger to be connected to a computer serial port or directly to a modem to be controlled and monitored over long distances The SWCA package includes the following items SWCA adapter gray plastic housing with green LED phone jack and a 25 pin connector e Custom made Serial Port Adapter black plastic housing with phone jack and 9 pin connector e 25 foot 4 conductor phone cable with RJ11 jack tabs on the same side of the cable e 3 5 floppy disk with DOS program SWCPS EXE simulates the inverters control panel SWCA Owner s Manual Please be sure all of these parts are included before trying to use the SWCA Phone Cable SWCA Adapter Custom Made Serial Port Adapter Figure 1 1 SW Communications Adapter SWCA 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 1 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 2 0 INSTALLATION The SWCA converts the REMOTE port on the SW series inverter charger into a standard RS232 type communications port interface See Figure 2 1 for the location of the REMOTE
21. the SWCA with Terminal Emulation Programs a modem capable of auto answer and supporting a 9600 baud connection adapter for the DB9 connection from the phone cable to serial port adapter a NULL MODEM adapter will be required for most applications Contact the modem provider and modem documentation for more information Additional Possible Reguirements The modem at the inverter location might need to be DC powered if it is necessary to connect to the inverter during a fault condition where the inverter has shut off its AC output Connecting Multiple SWCAs to a Single Computer Up to eight SWCAs can be used with a single computer serial port The phone cable four conductors are simply run in parallel using standard phone cable line splitters The splitters must connect the wires of the same color together not switch the colors around Before connecting multiple adapters to a serial port connect each adapter individually to ensure it operates properly The adapter ID number must be changed by using the DOS program provided on the disk before they are connected to the same computer serial port The ID number can only be changed with a single adapter connected to the computer s serial port 2002 Xantrex Technology Inc 4 P N 973 0022 01 01 Rev 04 2002 2 0 INSTALLATION Advanced Monitoring Software The SWCA was developed to change the SW inverter raw data output to an RS232 protocol output The S
22. ts and makes every effort to ensure your unit fully meets your independent powering needs If your product needs repair contact our Customer Service department at 360 435 8826 to obtain an RMA and shipping information or fax this page with the following information to 360 474 0616 Please provide Part Number Purchase Date Problem Include a telephone number where you can be reached during business hours and a complete return shipping address P O Box numbers are not acceptable Name Address City State Province Zip Postal Code Country Phone FAX ___ E mail Address 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev A 04 2002 A3 APPENDIX A PRODUCT amp SYSTEM INFORMATION Notes 02002 Xantrex Technology Inc A 4 P N 973 0022 01 01 RevA 04 2002 xantrex Smart Choice for Power 1360 435 8826 f 1 435 2229 dpm xantrex com www xantrex com P N 973 0022 01 01 Rev A Printed in USA
23. ugh this warranty gives you specific legal rights you may also have other rights which vary from state to state 2002 Xantrex Technology Inc P N 973 0022 01 01 Rev 04 2002 A 1 APPENDIX A PRODUCT amp SYSTEM INFORMATION RETURN MATERIAL AUTHORIZATION POLICY You must obtain a Return Material Authorization RMA number from Xantrex before returning a product directly to Xantrex Products returned without an RMA number or shipped collect will be refused When you contact Xantrex to obtain servcie be prepared to supply the serial number of your product and its date of purchase as well as information about the installation and use of the unit Record this information in Information About Your System on page A 3 ofthis guide RETURN MATERIAL PROCEDURE If you are returning a product follow this procedure 1 Obtain an RMA number and a shipping address from Xantrex 2 Package the unit safely preferably using the original box and packing materials Include the following The RMA number A copy of your dated proof of purchase A return address where the repaired unit can be shipped A contact telephone number A brief description of the problem 3 Ship the unit freight prepaid to the address provided in step 1 2002 Xantrex Technology Inc A 2 P N 973 0022 01 01 RevA 04 2002 APPENDIX PRODUCT amp SYSTEM INFORMATION SERVICE INFORMATION Xantrex Technology Inc takes great pride in its produc
24. xantrex Smart Choice for Power Owner s Manual SW Communications Adapter SWCA About Xantrex Xantrex Technology Inc is a world leading supplier of advanced power electronics and controls with products from 50 watt mobile units to 1 MW utility scale systems for wind solar batteries fuel cells microturbines and backup power applications in both grid connected and stand alone systems Xantrex products include inverters battery chargers programmable power supplies and variable speed drives that convert supply control clean and distribute electrical power Trademarks Trace and Xantrex are registered trademarks of Xantrex International Notice of Copyright SW Communications Adapter SWCA Owner s Manual April 2002 Xantrex Technology Inc All rights reserved Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide Xantrex International assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Since the use of this manual and the conditions or methods of installation operation use and maintenance of the unit are beyond the control of Xantrex Technology Inc the company does not assume responsibility and expressly disclaims liability for loss damage or expense arising out of or any way connected with such installation operation use or maintenance Due to continual improvement th
Download Pdf Manuals
Related Search
Related Contents
Man. KT-380EE User's Manual - Libero PROGRAMME - Coopération Santé Craftsman 917.37945 Lawn Mower User Manual peer level stander™ adjustments Altec Lansing IMT800 home audio set Nouveautés 2014 - SubZero Requirement Elicitation - School of Information Technologies User Manual Copyright © All rights reserved.