1. 3 Using 2 or more people lift range hood onto protective covering 4 Determine and mark the centerline on the wall where the canopy hood will be installed 5 Select a mounting height between 30 and 36 76 2 cm and 91 4 cm above the range to the bottom of the hood and mark reference line on the wall NOTE For installation locations with reduced ceilings heights the vent hood may be installed using the lower vent cover for both vented and non vented recirculating installations 6 Tape template in place aligning the template centerline and 10 11 12 13 bottom of template with hood bottom line and with the centerline marked on the wall A Centerline B Mounting hook location C Fastener locations D Mounting height reference Mark centers of the 6 fastener locations through the template to the wall IMPORTANT At least two of the screws must be installed into wood Remove the template Drill 764 2 75 mm pilot holes at all locations where screws are being installed into wood Determine and make all necessary cuts in the wall for the vent system Install the vent system before installing the hood See Venting Requirements section Determine the required height for the 1 conduit and drill a 1 8 2 cm hole at this location Run wire through the 2 conduit according to the National Electrical Code or CSA Standards and local codes and ordinances There must be enough 12 conduit an
2. lio Hae Exemple de circuit ra d vacuation 2 pi 1 coude 90 5 pi 1 5 m 0 6 m section droite de 8 pi 2 4m 8 pi 2 4 m 1 bouche de d charge murale Opi 0m Longueur quivalente totale du syst me 13 pi 8 9 m 18 AVERTISSEMENT Risque de choc lectrique D connecter la source de courant lectrique avant l entretien Replacer pi ces et panneaux avant de faire la remise en marche Le non respect de ces instructions peut causer un d c s ou un choc lectrique IMPORTANT La hotte doit tre correctement reli e la terre en conformit avec les codes et r glements locaux en vigueur ou en l absence d un tel code conform ment aux prescriptions de la plus r cente dition du National Electrical Code ANSI NFPA 70 ou du Code canadien des installations lectriques CSA C22 1 Si les codes en vigueur le permettent et si on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre Pour obtenir un exemplaire des codes mentionn s ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 L appareil doit tre aliment par un circuit de 120 V CA 60 Hz CA seulement 15 amp res prot g par fusible On recommande galement d utiliser un fusible ou un disjoncteur
3. 12 GARANTIE DE LA HOTTE DE CUISINI RE 26 WIRING DIAGRAM seen nnn 13 SCHEMA DE C BLAGE 27 RANGE HOOD SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean A DANGER WARNING All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed You can be killed or seriously injured if you don t immediately follow instructions You can be killed or seriously injured if you don t follow instructions IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING m Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch the power off at the service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device
4. m Utiliser un extincteur SEULEMENT si 1 s agit d un extincteur de classe ABC dont on connait le fonctionnement I s agit d un petit feu encore limit l endroit o il s est d clar Les pompiers ont t contact s est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu Recommandations tir es des conseils de s curit en cas d incendie de cuisine publi s par la NFPA m AVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique ne pas utiliser ce ventilateur avec un quelconque dispositif de r glage de la vitesse semi conducteurs CONSERVEZ CES INSTRUCTIONS 15 EXIGENCES D INSTALLATION Rassembler les outils et pi ces n cessaires avant de commencer IMPORTANT Observer les dispositions de tous les codes et l installation Lire et suivre les instructions fournies avec les outils r glements en vigueur indiqu s ici Installer la hotte d extraction distance de toute zone expos e Outillage n cessaire des courants d air telle que fen tres portes et bouches de m niveau chauffage Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards Les dimensions indiqu es prennent en compte les valeurs minimales des d gagements de s paration perceuse avec forets de 11 4 3 2 cm 38 9 5 mm 7 amp 4 2 75 mm et 3 mm crayon n cessaires m pince d nuder ou coute
5. 3 2 cm cet endroit Installer les conducteurs n cessaires dans le conduit de respecter les prescriptions du Code national de l lectricit ou de la norme CSA en vigueur ou des codes et r glements locaux en vigueur Il faut que la longueur des conducteurs et du conduit de 12 soit suffisante pour qu il soit possible de r aliser la liaison entre le tableau de distribution et les connexions dans la boite de connexion de la hotte Utiliser un calfeutrant pour assurer l tanch it au niveau de chaque ouverture NOTE Ne pas mettre le syst me sous tension avant d avoir compl tement termin l installation Fixer 2 crochets de montage sur le mur aux emplacements marqu s sur le gabarit A h ls A Crochets de montage B Axe central trac sur le mur 19 Installation de la bride du cache conduit Configuration d installation avec cache conduit sections sup rieure et inf rieure t lescopiques 1 Positionner la bride de fixation du cache conduit sur le mur environ 8 3 mm du plafond 2 Marquer la position des trous 3 Percer des trous de 38 9 5 mm pour les organes d ancrage et ins rer les chevilles placer les chevilles en affleurement avec le mur 4 Fixer sur le mur la bride de fixation du cache conduit A Bride de fixation du cache conduit B Axe central trac sur le mur Configuration d installation avec hauteur sous plafond r duite Lors de l installation de la
6. 76 2 cm 94 1 cm au dessus du plan de travail Avant de s lectionner la hotte installer mesurer la hauteur libre sous plafond et la hauteur maximum disponible pour la hotte AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la cuisini re Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure Si c est possible d brancher et d placer la cuisini re cuisini re autonome ou encastr e retirer la cuisini re de son espace d installation entre les placards pour faciliter l acc s au mur arri re Si ce n est pas possible placer un pais mat riau de protection sur le plan de travail et la table de cuisson ou la cuisini re pour la protection contre des dommages et contre les souillures S lectionner une surface plane pour l assemblage de la hotte Recouvrir cette surface avec un mat riau de protection AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisini re Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure Pour l op ration de levage de la hotte pour la placer sur la surface de travail prot g e faire intervenir 2 personnes ou plus D terminer la position appropri e et marquer l axe central de la hotte sur le mur l endroit o la hotte sera install e S lectionner une hauteur de monta
7. INSTALLATION INSTRUCTIONS 6 INSTRUCTIONS D INSTALLATION 19 Prepare Location onere eher e e ER cecus 6 Pr paration de l emplacement 19 Install Range n 7 Installation de la hotte de cuisini re 20 Install Vert aesti rss ces 8 Installation du circuit d vacuation 20 Make Electrical Connection 8 Raccordement lectrique 21 Complete Installation 9 Achever l installation 21 Install Filters heat aan Latin gr d 9 Installation des filtres 22 Check Operation Bresse durs sinus 9 Contr le du fonctionnement 22 RANGE HOOD USE 2 24 RB eee 10 UTILISATION DE LA HOTTE DE CUISINI RE 23 Op ration sas pd eek ueber RR ES UE 10 Fonctionnement 642 6 asec crane 23 RANGE HOOD CARE 10 ENTRETIEN DE LA HOTTE DE CUISINI RE 23 Cleaning caa eee ete 10 Nettoyage uude E a EOS ete ale N nr 23 sasuke REG RO EUR RC Re 11 ACCeSSOIFGS ue REX hielo REG RE ERG E RR 24 ASSISTANCE OR SERVICE 11 ASSISTANCE OU SERVICE 25 RANGE HOOD WARRANTY
8. ment de surface fonctionner puissance de chauffage maximale sans surveillance Un renversement d bordement de mati re graisseuse pourrait provoquer une inflammation et la g n ration de fum e Utiliser une puissance de chauffage moyenne ou basse pour le chauffage d huile Veiller toujours faire fonctionner le ventilateur de la hotte lors de la cuisson avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber savoir cr pes Suzette cerise jubil e steak au poivre flamb Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e Utiliser toujours un ustensile adapt la taille de l l ment chauffant AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APRES LE DECLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIERE APPLIQUER LES RECOMMANDATIONS SUIVANTES m Placer sur le r cipient un couvercle bien ajust une t le biscuits ou un plateau m tallique POUR ETOUFFER LES FLAMMES puis teindre le br leur gaz ou lectrique VEILLER A EVITER LES BRULURES Si les flammes ne s teignent pas imm diatement EVACUER LA PIECE ET APPELER LES POMPIERS m NE JAMAIS PRENDRE EN MAIN UN R CIPIENT ENFLAMME vous risquez de vous br ler m NE PAS UTILISER D EAU ni un torchon humide ceci pourrait provoquer une explosion de vapeur br lante
9. such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes amp standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other utilities Ducted systems must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE m Never leave the surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings m Always turn hood ON when cooking at high heat or when flameing food i e Crepes Suzette Cherr
10. 1 Pour contr ler le fonctionnement de la hotte r tablir installer le filtre charbon sur le carter du ventilateur faire l alimentation lectrique tourner la manette du filtre dans le sens horaire R p ter ceci pour chaque autre filtre charbon A l O 1 0123 A Commutateur d clairage B Commutateur du ventilateur 2 Pousser le commutateur d clairage la position 1 La lampe devrait s allumer 3 Pousser le commutateur d clairage la position 0 La A Carter du ventilateur lampe devrait s teindre E 4 Placer le commutateur du ventilateur la position 1 pour le Le fonctionnement basse vitesse la position 2 pour le fonctionnement vitesse moyenne ou position 3 pour Quelle que soit la configuration d installation ins rer le bord y du filtre m tallique dans la rainure arri re de l ouverture le fonctionnement haute Ve a d installation du filtre 5 Placer le commutateur du ventilateur a la position O Le Pousser la manette vers l arri re et pousser le filtre vers ventilateur devrait Wl de fonctionner MEM le haut 6 Sila hotte ne fonctionne pas d terminer si le circuit est correctement aliment disjoncteur ouvert ou fusible grill D connecter la source de courant lectrique du circuit et v rifier que le c blage est correct Tirer le filtre vers l avant et ins
11. 4 Move the blower switch to the 1 position for low speed 2 position for medium speed 3 position for high speed 5 Move the blower switch to the 0 position The blower should turn off 6 If range hood does not operate check that the circuit breaker has not been tripped or the house fuse blown Disconnect power supply and check that the wiring is correct RANGE HOOD USE The canopy hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen Hood control panel The hood controls are located on the underside of the canopy TE Cp 0123 A Light switch B Blower switch Operating the light 1 Move the light switch to the 1 position The light should turn on 2 Move the light switch to the 0 position The light should turn off Operating the blower 1 Move the blower switch to the 1 position for low speed 2 position for medium speed 3 position for high speed 2 Move the blower switch to the 0 position The blower should turn off RANGE HOOD CARE Be sure lights are cool before cleaning the hood Exterior surfaces Clean the range hood with a mild detergent and soft cloth Do not use abrasive cleanser or steel wool pads Metal grease filters The filt
12. Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez crire Whirlpool Canada Inc en soumettant toute question ou probl me au Centre d interaction avec la client le Whirlpool Canada Inc 1901 Minnesota Court Mississauga Ontario L5N 3A7 Dans votre correspondance veuillez indiquer un num ro de t l phone o l on peut vous joindre dans la journ e GARANTIE DE LA HOTTE DE CUISINI RE Pendant un an compter de la date d achat lorsque cet appareil est utilis et entretenu conform ment aux instructions jointes ou fournies avec le produit Whirlpool Corporation paiera pour les pi ces et la main d uvre de toute intervention sur votre hotte de cuisini re sauf ampoules et filtres n cessaire du fait d un vice de mat riau ou de fabrication Whirlpool Corporation ne paiera pas pour 1 Les visites de service pour rectifier l installation de l appareil montrer l utilisateur comment utiliser l appareil remplacer des fusibles ou rectifier le c blage du domicile ou remplacer des ampoules lectriques accessibles par le propri taire Pi ces consomptibles comme ampoules et filtres o PON Les r parations lorsque l appareil m nager est utilis des fins autres que l usage unifamilial normal Le ramassage et la livraison L appareil m nager est con u pour tre r par domicile Les dommages caus s par accident modification m susage abus incendie inondation mauvaise insta
13. Retirer les filtres graisse m talliques pousser la manette vers l arri re et tirer vers le bas 3 Tirer le filtre vers l avant conserver le filtre part 4 R p ter ces op rations pour la d pose de l autre filtre m tallique 5 Installer le filtre charbon sur le carter du ventilateur faire tourner la manette du blocage du filtre dans le sens horaire A Carter du ventilateur B Manette C Filtres charbon 6 R p ter ces op rations pour la d pose de l autre filtre charbon R installation des filtres graisse m talliques 7 Ins rer le bord arri re du filtre m tallique dans la rainure arri re de l ouverture d installation du filtre 8 Pousser la manette vers l arri re et pousser le filtre vers le haut 9 Tirer le filtre vers l avant et ins rer le filtre dans la rainure avant Remplacement des filtres charbon 1 Commander l arr t du ventilateur et l extinction des lampes 2 Enlever les filtres graisse m talliques Pousser la manette vers l arri re et tirer vers le bas 3 Tirer le filtre vers l avant et conserver le filtre part A R p ter ces op rations pour la d pose de l autre filtre 5 Faire tourner la manette de blocage du filtre charbon dans le sens antihoraire 6 Enlever et jeter le filtre charbon 7 R p ter ces op rations pour l autre filtre charbon 8 Installer un filtre charbon sur le carter du ventilateur faire tourner la man
14. d entretien m filtre s format ad quat selon le mod le et la taille m vis et ancrages pour panneaux de gypse 2 crochets de montage m gabarit de montage m cache conduit 2 sections m ruban adh sif caoutchouc 16 Espacements d installation D 17 8 cm 2 50 1 mm 7 17 8 cm max zones de passage pour le conduit d vacuation et le c ble d alimentation T lectrique r i 40 6 cm placard mn placard lat ral d lat ral 30 76 2 cm gt minimum 30 36 76 2 cm 91 4 cm entre la limite axe central inf rieure de la hotte et la table de cuisson Le circuit d vacuation de l air doit se terminer l ext rieur Ne pas terminer le circuit d vacuation dans un espace ferm grenier ou autre Ne pas utiliser une bouche de d charge murale de 4 10 2 cm du type utilis pour un appareil de buanderie Utiliser uniquement du conduit m tallique On recommande l emploi de conduit rigide Ne pas utiliser de conduit de plastique ou de m tal tr s mince Pour obtenir un fonctionnement efficace et silencieux Utiliser autant que possible des sections droites et minimiser le nombre de coudes Ne pas utiliser plus de trois coudes 90 Veiller ce qu il y ait une section droite de conduit de 24 61 cm ou plus entre deux coudes si on doit utiliser plus de un raccord coud Ne pas connecter ensemble deux raccords coud s Assure
15. except light bulbs and filters which are defective in materials or workmanship Whirlpool Corporation will not pay for 1 Service calls to correct the installation of your appliance to instruct you how to use your appliance to replace house fuses or correct house wiring or to replace owner accessible light bulbs Consumable parts such as light bulbs and filters Repairs when your appliance is used in other than normal single family household use Pickup and delivery Your appliance is designed to be repaired in the home Damage resulting from accident alteration misuse abuse fire flood improper installation acts of God or use of products not approved by Whirlpool Corporation or Whirlpool Canada Inc o PF D WHIRLPOOL CORPORATION AND WHIRLPOOL CANADA INC SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so this exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state or province to province Outside the 50 United States and Canada this warranty does not apply Contact your authorized Whirlpool dealer to determine if another warranty applies If you need service see the Requesting Assistance or Service section or call the Whirlpool Customer Interaction Center 1 800 253 1301 toll free from anywhere
16. hotte il est possible de n utiliser que la section inf rieure du cache conduit plus une pi ce de bois de 6 4 mm 1 Pour que le cache conduit puisse glisser vers le bas et s engager au sommet de la hotte il faut que la bride de fixation du cache conduit soit mont e 1 4 6 4 mm au dessous du plafond 2 L espace r siduel au dessus du cache conduit peut tre obtur l aide d une pi ce de contreplaqu de 6 4 mm configur e selon la forme du profil interne du couvre chemin e il suffira ensuite de r aliser une finition assortie celle du plafond 3 Couper le ruban adh sif de caoutchouc fourni avec la hotte en 4 sections identiques Apposer deux sections de ruban adh sif sur chaque c t de la bride de fixation au plafond A Ruban adh sif caoutchouc AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisini re Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure 1 Retirer la hotte de son emballage placer la hotte sur une surface prot g e 2 Incliner la hotte vers l arri re et enlever les filtres m talliques 20 3 Suspendre la hotte sur les 2 crochets de montage travers les ouvertures rectangulaires l arri re de la hotte 4 tablir l aplomb de la hotte utiliser les vis de r glage de l aplomb dans les crochets de montage ou les ouvertures rect
17. in the U S A For parts and service in Canada please call 1 800 807 6777 For product related questions in Canada please call 1 800 461 5681 Keep this book and your sales slip together for future Dealer name reference You must provide proof of purchase or installation date for in warranty service Address Write down the following information about your appliance to Phone number better help you obtain assistance or service if you ever need it You will need to know your complete model number and serial Model number number You can find this information on the model and serial number label plate located on your appliance Serial number Purchase date 12 WIRING DIAGRAM YIG d x2v18 ALIHM BROWN hi SIA ALIHM BLUE GREEN YELLOW GREEN 13 14 S CURIT DE LA HOTTE DE CUISINI RE Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de bless
18. more people to move and install range hood Failure to do so can result in back or other injury Remove hood from carton and set on protected surface Tip range hood back and remove metal filters Hang hood on 2 mounting hooks through the rectangular cutouts on back of hood 4 Level the hood with leveling screws in mounting hooks or rectangular cutouts using a level across bottom of hood A Mounting hooks B Mounting screws C Leveling screws D Centerline on wall 5 Secure hood with 4 screws through remaining 4 holes in hood Vented Installations 1 Fit vent system over transition piece 2 Seal connection with duct tape C A Vent system B Transition Non Vented Recirculating Installations Install the deflector inside lower vent cover with screws provided A Deflector AWARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock 1 Disconnect power 2 Remove terminal box cover 3 Remove the knockout in terminal box cover and install the UL or CSA listed 1 conduit 4 wires black white and green 14 AWG 2 conduit from service panel to terminal box A Conduit 5 Use twist on connectors and connect black wires together 6 Use twist on connectors and connect white wires together AWARNING Electrical Shock Hazard Electrically ground
19. rer le filtre dans la rainure avant UTILISATION DE LA HOTTE DE CUISINIERE La hotte est con ue pour extraire fum e vapeurs de cuisson et odeurs au dessus de la table de cuisson Pour obtenir les meilleurs r sultats mettre le ventilateur de la hotte en marche avant d entreprendre une cuisson et laisser le ventilateur fonctionner pendant plusieurs minutes apr s l ach vement d une cuisson pour pouvoir vacuer de la cuisine toute trace d odeur de cuisson vapeur ou fum e Tableau de commande de la hotte Les commandes de la hotte sont situ es sur la face inf rieure de la hotte A P e B 15 A Commutateur d clairage B Commutateur du ventilateur 0 123 Fonctionnement de la lampe d clairage 1 Pousser le commutateur d clairage la position 1 La lampe devrait s allumer 2 Pousser le commutateur d clairage la position 0 La lampe devrait s teindre Fonctionnement du ventilateur 1 Placer le commutateur du ventilateur la position 1 pour le fonctionnement basse vitesse la position 2 pour le fonctionnement vitesse moyenne ou la position 3 pour le fonctionnement haute vitesse 2 Placer le commutateur du ventilateur la position 0 Le ventilateur devrait cesser de fonctionner ENTRETIEN DE LA HOTTE DE CUISINIERE Avant toute op ration de nettoyage de la hotte v rifier que les lampes ont refroidi S
20. temporis Il est recommand d alimenter la hotte par un circuit distinct qui n alimente que cet appareil Ne pas utiliser une tuyauterie de gaz pour le raccordement la terre En cas de doute quant la qualit de la liaison la terre de la hotte consulter un lectricien qualifi Ne pas installer un fusible dans le conducteur neutre ou dans le conducteur de liaison la terre La hotte doit tre raccord e au r seau lectrique uniquement avec des conducteurs de cuivre La hotte de cuisini re doit tre reli e directement au tableau de distribution coupe circuit avec fusibles ou disjoncteurs par un c ble blind flexible ou un conduit m tallique flexible B lataille des conducteurs doit satisfaire aux prescriptions de la plus r cente dition du National Electrical Code ANSI NFPA 70 ou du Code canadien des installations lectriques normes CSA C22 1 94 et C22 2 n 0 91 et aux prescriptions de tous les codes et r glements locaux en vigueur INSTRUCTIONS D INSTALLATION 6 On ne doit couper un poteau de colombage ou une solive que si c est absolument n cessaire S il est n cessaire de couper un poteau ou une solive on devra construire une structure de support appropri e Avant d ex cuter les d coupages v rifier la disponibilit d un espace de passage suffisant dans le plafond ou le mur pour le conduit d vacuation Nous recommandons que la hotte soit install e 30 36
21. 0 442 1111 For further assistance If you need further assistance you can write to Whirlpool with any questions or concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence If you need assistance or service in Canada For product related questions please call the Whirlpool Canada Inc Customer Interaction Center toll free 1 800 461 5681 Monday to Friday 8 00 a m 6 00 p m EST Saturday 8 30 a m 4 30 p m EST Our consultants provide assistance with Features and specifications on our full line of appliances Referrals to local dealers For parts accessories and service in Canada Call 1 800 807 6777 Whirlpool Canada Inc designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in Canada For further assistance If you need further assistance you can write to Whirlpool Canada Inc with any questions or concerns at Customer Interaction Center Whirlpool Canada Inc 1901 Minnesota Court Mississauga Ontario L5N 3A7 Please include a daytime phone number in your correspondence 11 RANGE HOOD WARRANTY For one year from the date of purchase when this appliance is operated and maintained according to instructions attached to or furnished with the product Whirlpool Corporation will pay for labor and any parts of your range hood
22. 30 76 2 cm WALL MOUNT CANOPY RANGE HOOD HOTTE D ASPIRATION POUR MONTAGE MURAL 30 76 2 cm Table of Contents Table des mati res 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION RESIDENTIELLE UNIQUEMENT IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference Save installation instructions for local inspector s use IMPORTANT Installateur Remettre les instructions d installation au propri taire Propri taire Conserver les instructions d installation pour consultation ult rieure Conserver les instructions d installation pour consultation par l inspecteur local 9760267A TABLE OF CONTENTS TABLE DES MATI RES RANGE HOOD SAFETY 2 S CURIT DE LA HOTTE DE CUISINI RE 14 INSTALLATION REQUIREMENTS 4 EXIGENCES D INSTALLATION 16 Tools and Parts 2255522 e ERE tees mes Peed ods 4 Outillage et pi ces 16 Location Requirements 4 Exigences d emplacement 16 Venting Requirements 5 Exigences concernant l vacuation 17 Electrical Requirements 6 Sp cifications lectriques 18
23. and Use amp Care Guide m filter s depending on model and size screws and drywall anchors m 2 mounting hooks m mounting template 2 piece vent cover m rubber tape Installation Clearances D 17 8 cm 2 50 1 mm min 7 17 8 cm max vent and power supply cable entry location side side cabinet cabinet 30 76 2 cm gt minimum 30 to 36 76 2 cm to 91 4 cm bottom of canopy to cooking surface centerline Vent system must terminate to the outside Do not terminate the vent system in an attic or other enclosed area Bi Do not use 4 10 2 cm laundry type wall caps Use metal vent only Rigid metal vent is recommended Do not use plastic or metal foil vent For the most efficient and quiet operation Use a straight run or as few elbows as possible Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used Do not install two elbows together Use duct tape to seal all joints in the vent system Use caulking to seal exterior wall or roof opening around the cap Cold weather installations An additional backdraft damper should be installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of th
24. angulaires placer un niveau en travers du bas de la hotte pour le contr le A Crochets de montage B Vis de montage C Vis de r glage de l aplomb D Axe central sur le mur 5 Immobiliser la hotte avec 4 vis plac es dans les 4 trous restants de la hotte Installation avec d charge l ext rieur 1 Connecter le circuit d vacuation sur le raccord de transition 2 Assurer l tanch it avec du ruban adh sif pour conduit L A Circuit d vacuation B Raccord de transition Installation sans d charge l ext rieur recyclage Installer le d flecteur l int rieur de la section inf rieure du cache conduit utiliser les vis fournies A D flecteur AVERTISSEMENT Risque de choc lectrique D connecter la source de courant lectrique avant l entretien Replacer pi ces et panneaux avant de faire la remise en marche Le non respect de ces instructions peut causer un d c s ou un choc lectrique 1 D connecter la source de courant lectrique 2 ter le couvercle de la bo te de connexion 3 Dans le couvercle de la bo te de connexion ter l opercule arrachable et installer le conduit de 2 homologation UL ou CSA 4 Installer conducteurs dans le conduit de 1 2 conducteurs noir blanc et vert de calibre AWG 14 depuis le tableau de distribution jusqu la boite de connexion A Conduit 5 Connecter les conducteurs noirs ensemble utiliser un co
25. ap 90 elbow Example vent system 2ft 1 90 elbow 5ft 1 5m 8 ft 2 4 straight 8ft 2 4m 1 wall cap Oft 0m system length 138 3 9 m AWARNING I Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock IMPORTANT The hood must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this hood be provided Do not ground to a gas pipe B Check with a qualified electrician if you are not sure range hood is properly grounded BI Do not have a fuse in the neutral or ground circuit The range hood must be connected with copper wire only The range hood s
26. au utilitaire On doit disposer d une prise de courant lectrique reli e la m m tre ruban ou r gle terre Voir la section Sp cifications lectriques pince La hotte d extraction a t configur e l usine pour la d charge m pistolet de calfeutrage et compos de calfeutrage r sistant travers le toit ou le mur Pour une installation sans d charge l eau l ext rieur recyclage voir Installation sans d charge l ext rieur m ruban adh sif pour conduits recyclage la section Installation du circuit d vacuation a sciesauteuse oi scie On devra assurer l tanch it de toutes les ouvertures plafond et 9 mur d coup es pour l installation de la hotte m tournevis lame plate m cisaille de ferblantier m jeu de cl s Allen Pi ces n cessaires Dimensions du produit m conduit 1 x 1 m 1 bouche de d charge pour toit ou mur pos cm m circuit d vacuation conduit m tallique m 2 filtres charbon pour installation sans d charge m l ext rieur recyclage seulement 11 9 cm min Pi ces fournies 85 1 A Retirer les pi ces de l emballage v rifier la pr sence de toutes les pi ces m hotte d extraction avec ventilateur lampes et raccord de 20 transition avec clapet anti reflux install 63 0 2 ju m d flecteur pour installation sans d charge l ext rieur 76 2 cm max recyclage m Instructions d installation et Guide d utilisation et
27. blower Connect ground wire to green and yellow ground wire in terminal box Failure to do so can result in death or electrical shock 7 Use twist on connectors and connect green or bare wire with yellow green wire 8 Replace terminal box cover 9 Check all light bulbs to make sure they are secure in their sockets 10 Reconnect power 1 Install vent cover When using both upper and lower vent cover push lower cover down onto hood and lift upper cover to ceiling and install screws A Upper vent cover B Lower vent cover For reduced ceiling height installations when using only the lower cover push lower cover down onto hood and snap vent into place around vent cover bracket 1 For non vented recirculating installations install charcoal filter over grill on blower housing and turn filter handle clockwise Repeat with other charcoal filter A Blower housing B Handle C Charcoal filters 2 For all installations insert back edge of metal filter into rear channel of the filter opening 3 Push handle toward the rear and push filter up 4 Pull filter toward the front and insert into front channel 1 Check operation of the range hood by turning the power on A l TE A Light switch B Blower switch 0123 2 Move the light switch to the 1 position The light should turn on 3 Move the light switch to the 0 position The light should turn off
28. coal Filter Kit Part Number 4396848 ASSISTANCE OR SERVICE If you need assistance or service in U S A Call the Whirlpool Customer Interaction Center toll free at 1 800 253 1301 Our consultants are available to assist you When calling Please know the purchase date and the complete model and serial number of your appliance This information will help us better respond to your request Our consultants provide assistance with Features and specifications on our full line of appliances Installation information Use and maintenance procedures Accessory and repair parts sales Specialized customer assistance Spanish speaking hearing impaired limited vision etc Referrals to local dealers service companies and repair parts distributors Whirlpool designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the designated service company in your area you can also look in your telephone directory Yellow Pages If you need replacement parts If you need to order replacement parts we recommend that you use only factory authorized parts These parts will fit right and work right because they are made to the same exacting specifi cations used to build every new Whirlpool appliance To locate factory authorized parts in your area call our Customer Interaction Center telephone number your nearest authorized service center or 1 80
29. d wires from the fused disconnect or circuit breaker box to make the connection in the hood s electrical terminal box Use caulk to seal all openings NOTE Do not turn on power until installation is complete Attach 2 mounting hooks to the wall at locations marked on the template A a ls A Mounting hooks B Centerline on wall Vent Cover Bracket Installation Installations using telescoping upper and lower vent cover assembly 1 Position vent cover bracket wall about 3 mm away from the ceiling 2 Mark the hole locations 3 Drill 6 9 5 mm holes for wall anchors and insert anchors flush with the wall 4 Attach vent cover bracket to wall A Vent cover bracket B Centerline on wall Installation locations with reduced ceiling heights The vent hood may be installed using only the lower vent cover plus 1 4 6 4 mm thick wood filler 1 For the vent cover to slide down and engage the top of the hood the vent cover bracket must be mounted 6 4 mm below the ceiling 2 The remaining space above the vent cover can be filled with a 74 6 4 mm thick piece of plywood cut to the inside cross section of the chimney cover and finished to match the ceiling 3 Out the self adhesive rubber tape supplied with the hood in 4 identical pieces Attach two pieces of tape to each side of the ceiling bracket A Rubber tape AWARNING Excessive Weight Hazard Use two or
30. e thermal break The break should be as close as possible to where the vent system enters the heated portion of the house Make up air Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area Venting methods This canopy hood is factory set for venting through the roof or wall A 6 15 2 cm round vent system is needed for installation not included The hood exhaust opening is 6 15 2 cm round NOTE Flexible vent is not recommended Flexible vent creates back pressure and air turbulence that greatly reduces performance Vent system can terminate either through the roof or wall To vent through a wall a 90 elbow is needed For non vented recirculating installations see Non Vented Recirculating Installations in Install Vent section deflector 6 15 2 round vent wall cap Non vented recirculating Roof venting Wall venting Calculating Vent System Length To calculate the length of the system you need add the equivalent feet meters for each vent piece used in the system Vent piece 6 15 2 cm round 45 elbow 2 5 feet 0 8 m 9 90 elbow 5 0 1 5 S Maximum equivalent vent length is 35 feet 10 7 meters e ft 1 8 m wall c
31. ers should be washed frequently Place metal filters in dishwasher or hot detergent solution to clean Drain water through edge holes and let each filter dry thoroughly before replacing it To remove metal filters 1 Turn blower and lights off 2 Push handle toward the rear and pull downward 3 Pull filter toward the front 10 To replace the metal grease filters 4 Insert back edge of filter into rear channel of the filter opening 5 Push handle toward the rear and push filter up 6 Pull filter toward the front and insert into front channel Charcoal Filters For non vented recirculating installations The charcoal filters are not washable or reusable They should be changed every 6 months in normal use The charcoal filters capture unpleasant cooking odors To install charcoal filters 1 Turn blower and lights off 2 Remove the metal grease filters by pushing handle toward the rear and pull downward 3 Pull filter toward the front and set aside A Repeat to remove other metal filter 5 Install charcoal filter over grill on blower housing and turn filter handle clockwise A A Blower housing B Handle C Charcoal filters 6 Repeat to install other charcoal filter To replace the metal grease filters 7 Insert back edge of filter into rear channel of the filter opening 8 Push handle toward the rear and push filter up 9 Pull filter toward the front and insert into front channel To rep
32. ette de blocage dans le sens horaire 9 R p ter ces op rations pour l autre filtre charbon R installation des filtres graisse m talliques 10 Ins rer le bord arri re du filtre m tallique dans la rainure arri re de l ouverture d installation du filtre 11 Pousser la manette vers l arri re et pousser le filtre vers le haut 12 Tirer le filtre vers l avant et ins rer le filtre dans la rainure avant 24 Remplacement d une lampe L clairage sous la hotte est assur par des lampes incandescence de type E12 120 volts 40W culot E12 Avant toute intervention v rifier que l alimentation lectrique de la hotte est interrompue et que les lampes ont pu refroidir 1 Placer le commutateur d clairage la position 0 extinction des lampes 2 Retirer les filtres graisse m talliques en poussant la manette vers l arri re et en tirant vers le bas Tirer le filtre vers l avant conserver le filtre part R p ter ces op rations pour la d pose de l autre filtre Enlever chaque lampe d fectueuse Installer une lampe neuve la place de chaque lampe d fectueuse R installation des filtres graisse m talliques 7 Ins rer le bord arri re du filtre m tallique dans la rainure arri re de l ouverture d installation du filtre 8 Pousser la manette vers l arri re et pousser le filtre vers le haut 9 Tirer le filtre vers l avant et ins rer le filtre dans rainu
33. ge entre 30 et 36 76 2 cm et 94 1 cm au dessus de la cuisini re entre la cuisini re et la rive inf rieure de la hotte Marquer cette ligne de r f rence sur le mur NOTE Lorsque la hauteur libre sous plafond l emplacement d installation est r duite il est possible d utiliser le cache conduit plus court pour l installation de la hotte pour une installation avec conduit d vacuation et une installation sans d charge l ext rieur recyclage 10 11 12 13 Fixer le gabarit avec du ruban adh sif aligner l axe central du gabarit et le bas du gabarit avec les lignes correspondantes trac es sur le mur bas de la hotte et axe central A Axe central B Position de montage pour crochets C Position pour organes de fixation D Ligne de r f rence position selon la hauteur de montage travers le gabarit marquer sur le mur la position des 6 organes de fixation IMPORTANT faut qu au moins deux des vis de fixation Soient ancr es dans du bois Enlever le gabarit Percer un avant trou de 764 2 75 mm chaque emplacement de pose d une vis dans le bois Pour le passage du circuit d vacuation d terminer les emplacements appropri s et r aliser les ouvertures n cessaires dans le mur Installer le circuit d vacuation avant d installer la hotte Voir la section Exigences concernant l vacuation D terminer la hauteur n cessaire pour le conduit de 12 percer un trou de 1
34. hould be connected directly to the fused disconnect or circuit breaker box through flexible armored cable or flexible metallic conduit Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standard C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances INSTALLATION INSTRUCTIONS E Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Before making cutouts make sure there is proper clearance within the ceiling or wall for exhaust vent We recommend the hood be installed 30 36 76 2 cm 91 4 cm above the countertop Check your ceiling height and the hood height maximum before you select your hood AWARNING Excessive Weight Hazard Use two or more people to move and install range Failure to do so can result in back or other injury 1 If possible disconnect and move freestanding or slide in range from cabinet opening to provide easier access to rear wall Otherwise put a thick protective covering over countertop cooktop or range to protect from damage or dirt 2 Select a flat surface for assembling the unit Cover that surface with a protective covering AWARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury
35. ies Jubilee Peppercorn Beef Flamb m Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter m Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING m SMOTHER FLAMES with a close fitting lid cookie sheet or other metal tray then turn off the gas burner or electric element BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN you may be burned m DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation Read and follow the safety instructions provided with any tools IMPORTANT Observe all governing codes and ordinances Canopy hood locatio
36. l installation un circuit d vacuation constitu de conduit rond de diam tre 6 15 2 cm non fourni est n cessaire L orifice de sortie de la hotte est circulaire diam 6 15 2 cm NOTE On d conseille l emploi de conduit flexible Un conduit flexible peut susciter une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance La d charge de l air aspir peut tre effectu e travers le mur ou le toit Pour la d charge travers le mur on doit utiliser un raccord coud 90 Pour une installation sans d charge l ext rieur recyclage voir Installation sans d charge l ext rieur recyclage la section Installation du circuit d vacuation conduit rond d flecteur bouche de d charge murale installation sans d charge l ext rieur recyclage d charge travers le toit d charge travers le mur 17 Calcul de la longueur effective du circuit d vacuation Pour calculer la longueur effective du circuit d vacuation n cessaire ajouter les longueurs quivalentes pieds m tres de tous les composants utilis s dans le syst me Composant du circuit Coude 45 2 5 pi 0 8 m 9 Coude 90 5 0 pi 1 5 m S La longueur quivalente du circuit ne doit pas d passer 35 pieds 10 7 m tres Conduit rond dia 6 15 2 cm bouche de Coude 90 6 1 8
37. lace charcoal filters 1 Turn blower and lights off 2 Remove the metal grease filters by pushing handle toward the rear and pull downward Pull filter toward the front and set aside Repeat to remove other filter Turn charcoal filter handle counterclockwise Remove and discard charcoal filter Repeat to remove other charcoal filter Install replacement charcoal filter over grill in blower housing and turn filter handle clockwise 9 Repeat to install other charcoal filter D N O 5o To replace the metal grease filters 10 Insert back edge of filter into rear channel of the filter opening 11 Push handle toward the rear and push filter up 12 Pull filter toward the front and insert into front channel Replacing a light bulb The range hood uses 120 volt 40W type E12 incandescent bulbs Before you begin make sure that the range hood is turned off and that the bulbs have had sufficient time to cool 1 Move light switch to the 0 off position 2 Remove the metal grease filters by pushing handle toward the rear and pull downward Pull filter toward the front and set aside Repeat to remove other filter Remove the light bulb s Replace with new light bulb s To replace the metal grease filters 7 Insert back edge of filter into rear channel of the filter opening 8 Push handle toward the rear and push filter up 9 Pull filter toward the front and insert into front channel Char
38. llation actes de Dieu ou utilisation de produits non approuv s par Whirlpool Corporation ou Whirlpool Canada Inc WHIRLPOOL CORPORATION ET WHIRLPOOL CANADA INC N ASSUMENT AUCUNE RESPONSABILIT POUR LES DOMMAGES FORTUITS OU INDIRECTS Certains tats ou certaines provinces ne permettent pas l exclusion ou la limitation des dommages fortuits ou indirects de sorte que cette exclusion ou limitation peut ne pas tre applicable dans votre cas Cette garantie vous conf re des droits juridiques sp cifiques et vous pouvez galement jouir d autres droits qui peuvent varier d un Etat un autre ou d une province une autre l ext rieur du Canada et des 50 tats des tats Unis cette garantie ne s applique pas Contacter votre marchand Whirlpool autoris pour d terminer si une autre garantie s applique Si vous avez besoin de service voir la section Demande d assistance ou de service ou appeler sans frais le Centre d interaction avec la client le Whirlpool au 1 800 250 1301 de n importe o aux E U Pour les pi ces et le service au Canada veuillez appeler le 1 800 807 6777 Pour des questions relatives aux produits au Canada veuillez appeler le 1 800 461 5681 Conservez ce manuel et votre recu de vente ensemble pour r f rence ult rieure Pour le service sous garantie vous devez pr senter un document prouvant la date d achat ou d installation Inscrivez les renseignements suivants au sujet de votre appareil m nager pour mie
39. n should be away from strong draft areas listed here Tools needed such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance m level m drill with 174 3 2 cm 38 9 5 mm 764 2 75 mm and Grounded electrical outlet is required See Electrical 1 3 mm drill bits Requirements section m pencil The canopy hood is factory set for venting through the roof or Ji wall For non vented recirculating installations see Non Vented T E Sinipper or D EDS Recirculating Installations in Install Vent section Mo tape or ruler All openings in ceiling and wall where canopy hood will be m pliers installed must be sealed m caulking gun and weatherproof caulking compound m duct tape W jig saw or keyhole saw P Di m flat blade screwdriver roduct Dimensions m metal snips g m metric Allen wrench set 20 3 cm Parts needed m 1x 12 conduit 41716 20 3 11 9 m 1 wall or roof cap 131346 m metal vent system 85 1 cm max m 2 charcoal filters for non vented recirculating 2078 Parts supplied 53 0 cm min Remove parts from packages Check that all parts were included 76 2 mak installations only m hood canopy assembly with ventilator light bulbs and transition with back draft dampers installed m deflector for non vented recirculating installations m Installation Instructions
40. nnecteur de fils vis 6 Connecter les conducteurs blancs ensemble utiliser un connecteur de fils vis AVERTISSEMENT D Risque de choc lectrique Relier le ventilateur la terre Brancher le fil reli la terre au fil vert et jaune reli la terre dans la boite de la borne Le non respect de ces instructions peut causer un d c s ou un choc lectrique 7 Connecter ensemble le conducteur vert ou nu de liaison la terre et le conducteur jaune vert utiliser un connecteur de fils vis 8 R installer le couvercle sur la boite de connexion 9 Contr ler chaque lampe v rifier que chaque lampe est bien fix e dans sa douille 10 Reconnecter la source de courant lectrique Installer le cache conduit Pour une configuration d installation avec utilisation des deux sections du cache conduit ins rer la section inf rieure du conduit dans la hotte et pousser la section sup rieure du cache conduit jusqu au plafond installer les vis A Section sup rieure du cache conduit B Section inf rieure du cache conduit Pour une configuration d installation avec hauteur sous plafond r duite et utilisation de la section inf rieure du cache conduit seulement ins rer la section inf rieure de cache conduit dans la hotte et emboiter le cache conduit en place autour de la bride de fixation 21 1 22 Pour une installation sans d charge l ext rieur recyclage
41. r l tanch it de chaque jointure du circuit d vacuation avec du ruban adh sif pour conduit Utiliser un calfeutrant pour assurer l tanch it autour de la bouche de d charge l ext rieur entre le conduit et l ouverture travers le toit ou le mur Installation dans une r gion climat froid convient d installer un clapet anti reflux additionnel pour minimiser les reflux d air froid et d installer au sein du circuit d vacuation un mat riau non m tallique isolant thermique pour minimiser la conduction de chaleur entre l ext rieur et l int rieur de la maison Par rapport l isolant thermique le clapet anti reflux devrait tre situ du c t froid L isolant thermique doit tre plac aussi pr s que possible de l endroit o le circuit d vacuation p n tre dans la partie chauff e de la maison Air d appoint Le code du b timent local peut exiger l utilisation d un systeme d introduction d air d appoint dans le cas o la capacit d extraction pieds cubes d air par minute de la hotte est sup rieure une valeur sp cifi e La valeur sp cifi e d bit d air en pieds cubes par minute est variable d une juridiction une autre Pour d terminer les exigences sp cifiques consulter un professionnel local des installations de chauffage et climatisation M thodes d vacuation Cette hotte d extraction a t configur e l usine pour la d charge travers le toit ou le mur Pour
42. r le fonctionnement correct de tout appareil gaz combustion et vacuation des gaz combustion par la chemin e pour qu il n y ait pas de reflux des gaz de combustion Respecter les directives du fabricant de l quipement de chauffage et les prescriptions des normes de s curit comme celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les prescriptions des autorit s r glementaires locales Lors d op rations de d coupage et de percage dans un mur ou un plafond veiller ne pas endommager les c blages lectriques ou canalisations qui peuvent s y trouver Les syst mes d vacuation doivent toujours d charger l air l ext rieur MISE EN GARDE Cet appareil est congu uniquement pour la ventilation g n rale Ne pas l utiliser pour l extraction de mati res ou vapeurs dangereuses ou explosives MISE EN GARDE Pour minimiser le risque d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS M TALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINI RE m Ne jamais laisser un l
43. re avant Filtre charbon Pi ce num ro 4396848 ASSISTANCE OU SERVICE Si vous avez besoin d assistance ou de service aux Etats Unis T l phoner au Centre d interaction avec la client le Whirlpool sans frais au 1 800 253 1301 Nos consultants sont disponibles pour vous aider Lors de votre appel Veuillez conna tre la date d achat et les num ros de mod le et de s rie au complet de votre appareil Ces renseignements nous aideront mieux r pondre votre demande Nos consultants fournissent de l assistance pour m Caract ristiques et sp cifications de notre gamme compl te d appareils m nagers m Renseignements d installation m Proc d s d utilisation et d entretien m Vente d accessoires et de pi ces de rechange m Assistance sp cialis e au client langue espagnole malentendants malvoyants etc m Les r f rences aux concessionnaires compagnies de service de r paration et distributeurs de pi ces de rechange locaux Les techniciens de service d sign s par Whirlpool sont form s pour remplir la garantie des produits et fournir un service apr s garantie partout aux Etats Unis Pour localiser la compagnie de service d sign e dans votre r gion vous pouvez galement consulter les Pages jaunes Si vous avez besoin de pi ces de rechange Si vous avez besoin de commander des pi ces de rechange nous vous recommandons d employer uniquement des pi ces d origine Ces pi ces conviendron
44. t et fonctionneront bien parce qu elles sont fabriqu es avec la m me pr cision utilis e dans la fabrication de chaque nouvel appareil Whirlpool Pour localiser des pi ces de rechange d origine dans votre r gion t l phoner au Centre d interaction avec la client le au centre de service d sign le plus proche ou appeler le 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez crire Whirlpool en soumettant toute question ou probl me Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Dans votre correspondance veuillez indiquer un num ro de t l phone o l on peut vous joindre dans la journ e Si vous avez besoin d assistance ou de service au Canada Pour des questions relatives aux produits veuillez appeler sans frais le Centre d interaction avec la client le de Whirlpool Canada Inc au 1 800 461 5681 Du lundi au vendredi de 8 h 00 18 h 00 HNE Le samedi de 8 h 30 16 h 30 HNE Nos consultants fournissent de l assistance pour Caract ristiques et sp cifications de notre gamme compl te d appareils m nagers R f rences aux concessionnaires locaux Pour pi ces accessoires et service au Canada T l phoner au 1 800 807 6777 Les techniciens de service d sign s par Whirlpool Canada Inc sont form s pour remplir la garantie des produits et fournir un service apr s garantie partout au Canada
45. ure grave si vous ne DANG ER suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous AVERTISSEM ENT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions IMPORTANTES INSTRUCTIONS DE S CURIT AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE CHOC LECTRIQUE OU DOMMAGES CORPORELS RESPECTER LES INSTRUCTIONS SUIVANTES m Utiliser cet appareil uniquement dans les applications envisag es par le fabricant Pour toute question contacter le fabricant m Avant d entreprendre un travail d entretien ou de nettoyage interrompre l alimentation de la hotte au niveau du tableau de disjoncteurs et verrouiller le tableau de disjoncteurs pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de verrouiller le tableau de disjoncteurs placer sur le tableau de disjoncteurs une tiquette d avertissement pro minente interdisant le r tablissement de l alimentation m Tout travail d installation ou c blage lectrique doit tre r alis par une personne qualifi e dans le respect des prescriptions de tous les codes et normes applicables y compris les codes du b timent et de protection contre les incendies m Une source d air de d bit suffisant est n cessaire pou
46. urfaces externes Nettoyer la hotte avec un d tergent doux et un chiffon doux Ne pas utiliser un produit de nettoyage abrasif ou un tampon de laine d acier Filtres graisse m talliques Laver fr quemment les filtres graisse Placer les filtres graisse m talliques dans un lave vaisselle ou une solution de d tergent chaude Drainer l eau par les trous des bords et laisser chaque filtre s cher compl tement avant de le r installer D pose des filtres graisse m talliques 1 Commander l arr t du ventilateur et l extinction des lampes 2 Pousser la manette vers l arri re et tirer vers le bas 3 Tirer le filtre vers l avant R installation des filtres graisse m talliques 4 Ins rer le bord arri re du filtre m tallique dans la rainure arri re de l ouverture d installation du filtre 5 Pousser la manette vers l arri re et pousser le filtre vers le haut 6 Tirer le filtre vers l avant et ins rer le filtre dans la rainure avant Filtres charbon pour configuration d installation sans d charge l ext rieur recyclage Les filtres charbon ne sont pas lavables ou r utilisables On doit normalement changer les filtres charbon intervalle de 6 mois service normal Les filtres charbon ont pour fonction de retenir les compos s responsables des odeurs de cuisson 23 Installation des filtres charbon 1 Commander l arr t du ventilateur et l extinction des lampes 2
47. ux vous aider obtenir assistance ou service en cas de besoin Vous devrez conna tre le num ro de mod le et le num ro de s rie au complet Vous pouvez trouver cette information sur la plaque signal tique situ e sur votre appareil 26 Nom du marchand Adresse Num ro de t l phone Num ro de mod le Num ro de s rie Date d achat SCH MA DE C BLAGE JAUNE VERT 27 Printed in Italy 9760267A Imprim en Italie 2005 Whirlpool Corporation 04 2005