Home

Weslo Daybreak SPRW52464 User's Manual

image

Contents

1. Model No SPRW52464 Serial No Write the serial number in the space above for reference Serial Number Decal QUESTIONS As a manufacturer we are com mitted to providing complete customer satisfaction If you have questions or find that there are missing or damaged parts we will guarantee complete satis faction through direct assistance from our factory TO AVOID UNNECESSARY DELAYS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m MST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future reference DayBr eak USER S MANUAL A pH testing kit not included is required for proper use and maintenance of the DAYBREAK A pH testing kit can be pur chased at any spa or pool supply store TABLE OF CONTENTS LIMITED WARRANTY o A A A O SS 2 IMPORTANT SAFETY INSTRUCTIONS 1 0 0 000 cc eee 3 WARNING DECAL PLACEMENT sua rad eek Seed eee ea ae ae bb aes 5 BEFORE YOU BEGIN surco ala lA dandy a de eae 6 CHOOSING A LOCATION FOR THE DAYBREAK 0 000 nee eae 7 ASSEMBLY a A ea a enti ia ieee dati MS A Aa T 8 USING THE DAYBREAK faemina caida A a dd Bie ee 12 MAINTENANCE cui A SR Madde Ba Se ed 15 TROUBLE SHOOTING mira na ia ari
2. and adjusting the pH SANITIZING THE DAYBREAK Please refer to your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa The most common sanitizing agent is a solid bromine concentrate The amount required varies according to several factors such as user load temperature water conditions and so forth Proper water maintenance is a fairly complex process We recommend that you contact your local pool and spa supplier for information on how you should best accomplish this TROUBLE SHOOTING Most problems can be solved by following the simple steps below Find the symptom that applies and follow the steps listed If further assistance is needed call our Customer Service Department toll free at 1 800 999 3756 Monday through Friday 6 a m until 6 p m Mountain Time SYMPTOM THE SPA WILL NOT OPERATE a Check the power cord The power cord must be plugged into a grounded outlet see PLUG GING IN THE DAYBREAK on page 12 b Check to see if the GFCI breaker is tripped or was not turned on Reset the GFCI breaker SYMPTOM THE CIRCUIT BREAKER OR GFCI BREAKER TRIPS WHILE THE SPA IS OPERATING a Reset the circuit breaker If the circuit breaker trips again contact a qualified electrician for service SYMPTOM THE PUMP HUMS a The filter may be dirty or damaged Remove the filter housing from the spa jet unit and clean or replace the filter b The p
3. be tight The water will heat at about 1 5 F an hour with the cover on If you are using the DAYBREAK indoors and the room temperature is maintained at 70 F it will take approximately 36 to 48 hours for the water to reach the set temperature The temperature and water flow can be set or changed by the controls on the console see USING THE CONSOLE on the next page TESTING AND TREATING THE WATER The DAYBREAK comes with a starter chemical pack for maintaining the water in the spa Disregard the directions on the individual packages of QUICK pHix It DOWN and QUICK pHix It UP However the directions on the bottle of Non chlorine Shox and Bromine Base are correct Always keep the chemi cals away from children and pets The first time you use the spa you should test and treat the water Once you have verified that the spa jet unit is functioning properly and have allowed the water to circulate for a while you should remove the spa cover and add 1 3 of the Bromine Base bottle and 1 3 of the Non chlorine Shox bottle to the water in the spa Allow the water to circulate for five min utes You should now test the pH level of the water You will need a pH test kit not included which can be obtained at a pool and spa supply store The pH reading should be between 7 2 and 7 8 If the level is too low add half of one of the QUICK pHix It UP packets to the water Let the water circu late t
4. calling 1 The MODEL NUMBER of the product SPRW52464 2 The NAME of the product DAYBREAK by WESLO 3 The SERIAL NUMBER of the product see the front cover of this manual 4 The KEY NUMBER and DESCRIPTION of the desired part s see the PART LIST on page 18 of this manual Part No 143642 HO0032 C RO198A Printed in USA O 1998 ICON Health 4 Fitness Inc
5. Bracket 6 into the Side Brackets 5 Attach the Angle Bracket to the other Side Panel with a Bracket Screw 4 Continue to connect the remaining Side Panels 1 in the same manner e Read each assembly step before you begin During assembly make sure that all parts are ori ented as shown in the drawings TOOLS REQUIRED FOR ASSEMBLY Your own phillips screwdriver The included allen wrench Llo You may also need a hammer 4 Place the Insulated Floor Cover 8 inside the assembled Side Panels 1 The edge of the Insulated Floor Cover should cover the bottom two inches of the Side Panels see the inset drawing Measure the width of the DAYBREAK from the top center of one Side Panel 1 to the top center of the Side Panel directly across from it Take two mea surements as shown Both measurements must be the same The measurement should be between 56 and 58 If the frame is not squared the Spa Cover not shown will not fit properly If measurements necessary adjust the positions of the Side Panels must be equal so the frame is squared 5 Place the Spa Liner 9 on top of the Insulated Floor Cover 8 Smooth out the Spa Liner working the wrinkles to the edges The seam in the Spa Liner should be lined up with a joint between two of the Side Panels 1 Stretch the edge of the Spa Liner 9 over the top of the Side Panels 1 working the wrinkles to t
6. Nozzle Spa Cover Edge Protector Spa Jet Unit Small Edge Protector Lower Heat Control Nut Filter Cover Screw Suction Cover Suction Fitting Pump Motor Buckle Heat Controller Buckle Screw Heat Sensor Electronic Control Tri jet Nozzle Headrest Nut Upper Heat Control Nut Rubber Insulator Washer Whirlpool Diverter Key No Qty h h h i ld _ O 2 A ANAND d HAH AH N a RSH RB CUO CUNO AH NNNM ot RO198A Description Rubber Damper Wire Harness Air Control Knob On Off Switch Assembly Thermostat Knob w Screw Primer Cap Housing Screw Console Overlay Micro Switch Wire Control Mounting Screw Control Mounting Nut Motor Mount Bracket Housing Support Bracket Cable Clamp Filter Cover 3 8 Compression Fitting Temperature Tube Set Screw Primer O ring Short Head Fitting Motor Endcap Motor Cap Screw Power Cord Grommet Trim Filter Cover Screw Support Ball Set Key Allen Wrench Starter Chemical Pack User s Manual Video Note indicates a non illustrated part Specifications are subject to change without notice 18 EXPLODED DRAWING Model No SPRW52464 RO198A ORDERING REPLACEMENT PARTS To order replacement parts simply call our Customer Service Department toll free at 1 800 999 3756 Monday through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please be pre pared to give the following information when
7. OVER REMOVE STANDING WATER CHILD CAN DROWN ON TOP OF COVER REMOVE COVER S COMPLETELY BEFORE ENTRY OF BATHERS ENTRAPMENT POSSIBLE NON SECURED OR IMPROPERLY SECURED COVERS ARE A HAZARD FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN INJURY OR DROWNING THIS IS NOT A SAFETY COVER PREVENT DROWNING SUPERVISE CHILDREN AT ALL TIMES ATTACH SPA COVER AFTER EACH USE SPA HEAT CAN CAUSE HYPERTHERMIA AND UNCONSCIOUSNESS SPA HEAT IN CONJUNCTION WITH ALCOHOL DRUGS OR MEDICATION CAN CAUSE UNCONSCIOUSNESS PREVENT ELECTROCUTION NEVER PLACE ANY ELECTRIC APPLIANCE WITHIN 5 FEET OF SPA NEVER SUBMERGE ENTIRE EQUIPMENT PACK IN WATER REFER TO OWNER S MANUAL FOR PROPER INSTALLATION BEFORE YOU BEGIN Thank you for selecting the DAYBREAK by WESLO The innovative DAYBREAK offers the features and quality of a traditional hot tub at an affordable price Best of all the DAYBREAK is fully portable so you can take it wherever there is an electrical outlet The DAYBREAK allows you to relax and unwind in the comfort of your own home For your benefit read this manual carefully before using the DAYBREAK by WESLO If you have addi tional questions please call our Customer Service Console Under Spa Cover Side Panel Power Cord Ground Fault Circuit Interrupter GFCI Department toll free at 1 800 999 3756 Monday through Friday 6 a m until 6 p m Mountain Time excl
8. around the DAYBREAK to permit servicing of the unit The diameter of the tub is 60 You should allow for this size plus the size of the spa jet unit when choosing the loca tion Be sure to note any other considerations such as aesthetics or privacy concerns which may affect the safety or enjoyment of using the DAYBREAK ASSEMBLY Before beginning assembly carefully read the following information and instructions e Place all parts in a cleared area and remove the packing materials do not dispose of the packing materials until assembly is completed e Assembly requires two people Tighten all parts as you assemble them unless instructed to do otherwise 1 Before beginning assembly be sure that you have read and understand the information in the box above and on the previous page Press a Floor Cap 2 onto the bottom of each of the eight Side Panels 1 Be sure to align the indicat ed holes The Side Panels must be oriented and fully inserted in the Floor Caps as shown in the inset drawing 2 Slide an Angle Bracket 3 between one of the Side Panels 1 and the Floor Cap 2 as shown Attach the Angle Bracket to the Side Panel with a Bracket Screw 4 Attach an Angle Bracket 3 to each of the remaining Side Panels 1 in the same manner 3 Slide two of the Side Panels 1 together as shown The indicated Angle Bracket 3 should go between the Side Panel and the Floor Cap 2 Slide a Connector
9. d 104 F 40 C are considered to be safe for healthy adults However if you plan to remain in the DAYBREAK for more than 10 to 15 minutes a lower temperature is rec ommended Lower temperatures are also rec ommended for children WARNING To reduce the risk of injury Always use an accurate thermometer to determine the water temperature before using the DAYBREAK 27 28 29 30 31 32 WARNING To reduce the risk of injury Pregnant women should consult with their physician before using the DAYBREAK Pregnant women should not use the DAY BREAK if the water temperature is above 100 F 38 C the unborn child could be seri ously harmed DANGER To reduce the risk of drowning Prolonged immersion in the DAYBREAK may cause hyperthermia a dangerous condition which occurs when the internal body temper ature rises several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia are nausea dizziness drowsi ness and fainting Effects include a lack of awareness inability to perceive heat or dan ger and a greater risk of drowning due to a loss of consciousness Special note Individuals suffering from hyperthermia may be unable to realize that they must exit the DAYBREAK and they also may be physically unable to do so WARNING To reduce the risk of drowning Heat from the water in conjunction with alco hol or drugs can cause unconsciousness Do not use the DAYBREAK if y
10. d to soak it in a cleaning solution which can be obtained from a pool and spa supply store Inspect the filter for damage Replace the fil ter if there are any signs of damage 5 Re insert the cleaned filter into the spa jet unit 4 MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover hang it over a clothes line and spray it with a hose Leave the cover on the clothes line until it is fully dry WINTER USE AND CARE The DAYBREAK is designed for year round use If you decide to store the DAYBREAK for the winter store it in a warm dry location See DRAINING THE DAYBREAK and DRAINING THE PUMP on page 14 WATER CHEMISTRY The DAYBREAK comes with a starter chemical pack for maintaining the water in the spa See TESTING AND TREATING THE WATER on page 12 Additional chemicals can be purchased at a pool and spa supply store CAUTION The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous Always follow these basic guide lines when handling the chemicals 1 Always read and follow the directions on the label unless directed otherwise Never mix different chemicals Do not exceed the recommended amounts follow the directions on the label closely 2 3 15 4 Keep all chemicals out of the reach of chil dren and pets 5 Keep all containers closed tightly when not in use 6 Never add water to the chemicals always add th
11. days contact our customer service department or a local spa and pool service provider SYMPTOM THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW a Adjust the water level This usually occurs only when the water level is low Add water until the filter and jets are covered SYMPTOM THE SPA JET UNIT CAVITATES DURING USE a This problem is caused by excess air in the pump circulation system Check to see if the primer cap is fully tightened Prime the pump again and fully tighten the primer cap see PRIMING THE SPA JET UNIT on page 12 SYMPTOM THE WATER IS NOT BEING CLEANED BY THE FILTER a Check to see if the filter is in place Clean the filter if it is dirty b Check the chemical balance of the water If the pH is incorrect the sanitizing agents will not function properly 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF b A clamp or seal inside the spa jet may be loose Check the floor around the spa jet unit for excess water and watch the spa jet unit while it is operating to see if water drips from the spa jet unit housing If you can identify the location of the leak inside the spa jet unit tight en the clamp or replace the damaged seal a To turn the spa jet unit on press the ON OFF control once To turn the spa jet unit off press the control twice After you press it once the spa jet unit will shut off for about 30 seconds and restart Press the control again The spa jet u
12. e only Do not use the DAYBREAK in any com mercial rental or institutional setting Use the DAYBREAK only on a level surface Do not use the DAYBREAK on carpet or other materials that could be damaged by moisture Do not use the DAYBREAK on rough or sharp surfaces such as gravel or wood chips The DAYBREAK will weigh approximately 1600 pounds when it is assembled and filled with water Be sure that the location you select for the DAYBREAK will support this weight plus the weight of the occupants Inspect and tighten all parts regularly Replace any worn parts immediately DANGER Risk of injury Do not remove or alter the covers on the suction fittings Never operate the DAYBREAK if the suction guard is missing or broken Keep hair and body away from the suction guard If you need to replace a suction fitting be sure that the flow rate of the replacement is compatible Do not bring any object into the DAYBREAK that could puncture the liner Never insert any object into any opening Do not sit on the spa cover or place objects on it It is not designed to support weight Remove any water which may collect on the spa cover Keep children and pets away from the DAY BREAK when it is not in use 13 14 15 16 17 18 19 Keep all chemicals away from children and pets The pH and chemical balance of the water must be maintained as explained in this man ual see page 15 Failure to do so may ca
13. e chemicals to the water as directed 7 Always store chemicals in a cool dry place 8 Always keep chemicals away from chil dren and pets MAINTAINING THE PROPER PH BALANCE The pH factor is a measure of relative acidity or alka linity in the water It is measured on a scale of 1 to 14 Pure water has a value of 7 which is neutral Any value above 7 is alkaline and any value below 7 is acidic You should maintain a slightly alkaline pH level between 7 2 and 7 8 in the DAYBREAK Severe problems can occur when the pH balance is not maintained within this range If the pH level exceeds 7 8 dissolved minerals can build up and clog the plumbing in the spa jet unit If the pH level falls below 7 2 the acid level in the water will begin to cor rode the metal parts in the spa jet unit Also the sani tation agents in the water will not be effective if the pH level is not properly maintained Damage caused by improper pH levels is not covered under the warranty To maintain the proper pH level you should test the pH of the water regularly You will need a pH test kit not included which can be obtained at a pool and spa supply store The pH reading should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again after five minutes See the instructions with your pH test kit for additional information about testing
14. epaired or replaced by a qualified electrician 20 21 22 23 24 25 26 Keep all electrical appliances such as radios telephones televisions and lights at least five feet 1 52 meters away from the water A wire connector is provided on the pump motor of this unit to connect a minimum No 8 AWG 804 mm solid copper conductor between this unit and any metal equipment electrical enclosure made of metal metal water pipes or conduit within five feet 1 52m of the unit DANGER Risk of electric shock Do not set up the DAYBREAK within five feet of any metal objects or surfaces As an alternative you may use the DAYBREAK within five feet of metal objects if each metal object is per manently connected to the wire connector on the pump motor of this unit by a minimum No 8 AWG 804 mm solid copper conductor see instruction 21 DANGER Risk of drowning Exercise extreme caution to prevent unauthorized and unsupervised use of the DAYBREAK by chil dren Children must always be supervised DANGER To reduce the risk of drowning e Never use the DAYBREAK alone e Children should not use the DAYBREAK unless they are supervised by an adult e Keep pets away from the DAYBREAK at all times Always replace and lock the spa cover when the DAYBREAK is not in use WARNING To reduce the risk of injury The water temperature should never exceed 104 F 40 C Temperatures between 100 F 38 C an
15. h enough water to cover the water jets and the pump has been primed the power cord can be plugged in and the spa jet unit can be turned on Note The first time the power cord is plugged in the spa jet unit will turn on automatically When connecting the power cord plug the power cord directly into a grounded circuit capable of carrying 15 Grounded circuit capable of carrying 15 or more amps 12 or more amps No other appliance should be on the same circuit Replace the power cord immediately if it becomes damaged The power cord is equipped with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord You should always test the GFCI before using the DAYBREAK First turn on the DAYBREAK by pressing the power button on the console Once the unit is running press the GFCI test button The DAYBREAK should shut off Press the reset button The DAYBREAK should resume normal operation If the DAYBREAK contin ues to run after the test button is pressed then the GFCI is damaged Do not use the DAYBREAK until the GFCI has been repaired or replaced by a qualified electrician STARTING THE DAYBREAK Once you have tested the GFCI you should verify the water flow from the pumping unit Set the air control on the console to the lowest setting see USING THE CONSOLE on the next page The pumping unit will heat the water as it pumps Cover the DAYBREAK with the spa cover The spa cover must
16. he top The edge of the Spa Liner should hang over the Side Panels about two inches 6 Place the Small Edge Protector 14 on top of the Side Panel 1 closest to the electrical outlet which you will use to power the DAYBREAK This is the Side Panel where the Spa Jet Unit not shown will be placed Place the seven Edge Protectors 12 around the top of the remaining Side Panels 1 7 Remove the power cord from the Spa Jet Unit 13 Place the Spa Jet Unit over the Side Panel 1 with the Small Edge Protector 14 Be extremely care ful not to tear the Spa Liner 9 as you slide the Spa Jet Unit into place 8 Before you fill the DAYBREAK be sure that it is in the position you want and that it can be easily ser viced if needed Once the DAYBREAK is filled with water it will need to be drained to be moved Using a garden hose or other clean water source begin filling the DAYBREAK Be sure to check for wrinkles which may form in the Spa Liner 9 as the water begins to cover the bottom lt is very important that you remove as many wrinkles from the floor and sides of the DAYBREAK as possible To do this you should smooth any wrinkles out toward the sides and then smooth the wrinkles to the top It is normal to have some wrinkles around the Spa Jet Unit 13 Continue to fill the DAYBREAK until the jet and fil ter openings on the Spa Jet Unit 13 are covered with water Do not fill the DAYBREAK above the bo
17. hrough the spa jet unit for five minutes Test the pH level again Repeat until the pH level is correct If the level is too high add half of one of the QUICK pHix It DOWN packets to the water Let the water cir culate through the spa jet unit for five minutes Test the pH level again Repeat until the pH level is correct Replace the spa cover and allow the water to contin ue to heat See WATER CHEMISTRY on page 15 for information concerning proper water maintenance DIAGRAM OF THE CONSOLE PRIMER DIVERTER SECURING THE SPA COVER The spa cover can be secured by snapping the latch es on the spa cover into the buckles on the side panels The buckles can be locked by inserting the key and turning it clockwise a quarter turn To unlock the buckles insert the key and turn it counter clockwise a quarter turn Always keep the buckles locked when the spa is not in use Keep the keys in a safe place out of the reach of children AIR CONTROL a es FRONT P gt TINS fo S f USING THE CONSOLE Refer to the console diagram above The function of each console control is explained below Primer This opening allows you to prime the spa jet unit before operation see PRIMING THE SPA JET UNIT on page 12 Diverter Controls the flow of water through the hydro therapy jets and the whirlpool diverter The direction of the flow can be adjusted by turning the diverter control When the cont
18. is filled with water plus the weight of the occupants The DAYBREAK weighs approx imately 1600 pounds when filled with water Do not use the DAYBREAK above a finished living area due to the risk of water damage Be sure that there is room around the DAYBREAK to permit servicing of the unit The diameter of the tub is 60 You should allow for this size plus the size of the spa jet unit when choosing the loca tion Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the DAYBREAK If you set up the DAYBREAK outside 1 You should check your local building codes con cerning the use of outdoor spas The location must be close to an electrical outlet Do not use an extension cord with the DAY BREAK The DAYBREAK should be close to a source of water We recommend that you place the DAYBREAK on a water and stain resistant non slip surface Be sure that the location you choose is stable It must be able to support the weight of the DAY BREAK when it is filled with water plus the weight of the occupants The DAYBREAK weighs approx imately 1600 pounds when filled with water Think about environmental factors such as rain wind shade sunlight and so forth You should be able to monitor the use of the DAY BREAK from your home to prevent unauthorized use by children Be sure that there is room
19. n ee ae ed ee 16 WIRING DIAGRAM soci a tein arated een ae asians AAA E haan enya amary 17 PART EIS Tor e Than aia o a DTS Obata A RT a leah a Sure Et 18 EXPLODED DRAWING isa A AAA A a 19 ORDERING REPLACEMENT PARTS 0 0000 cece eee teens Back Cover WESLO is a registered trademark of ICON Health amp Fitness Inc LIMITED WARRANTY ICON Health amp Fitness Inc ICON warrants this product to be free from defects in workmanship and material under normal use and service conditions for a period of ninety 90 days from the date of pur chase This warranty extends only to the original purchaser ICON s obligation under this warranty is lim ited to replacing or repairing at ICON s option the product at one of its authorized service centers All products for which warranty claim is made must be received by ICON at one of its authorized service cen ters with all freight and other transportation charges prepaid accompanied by sufficient proof of purchase All returns must be pre authorized by ICON This warranty does not extend to any product or damage to a product caused by or attributable to freight damage abuse misuse improper or abnormal usage or repairs not provided by an ICON authorized service center products used for commercial or rental pur poses or products used as store display models No other warranty beyond that specifically set forth above is authorized by ICON ICON is not responsible or liable for indi
20. nit will remain off for three hours at which 12 SYMPTOM THERE ARE WRINKLES IN THE time it will begin running the filter cycle At any LINER time after the spa jet unit has been shut off the pump will begin cycling the water if the temper a Drain the water from the DAYBREAK until the ature falls below the minimum setting 11 SYMPTOM THE WATER LEVEL DROPS a Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the DAYBREAK then the liner may have a leak Locate the leak and patch it using a pool patch kit that you can pur chase at any pool and spa supply store WIRING DIAGRAM POWER GFCI SUPPLY BLACK HOT water level is below the wrinkles Smooth out any wrinkles that you can see Begin to refill the DAYBREAK Be sure to check for new wrinkles that may form in the spa liner as the water begins to cover the bottom Smooth out any wrinkles toward the sides and then smooth the wrinkles to the top It is normal to have some wrinkles around the spa jet unit ion GROUNDING CONDUCTOR LUG Pressure Wire Connector GREEN GROUND See the manufacturer s wiring diagram on the pump motor for more information 17 PART LIST Model No SPRW52464 Key No Qty OONDARWNDN Description Side Panel Floor Cap Angle Bracket Bracket Screw Side Bracket Bracket Connector Bolt Insulated Floor Cover Spa Liner Spa Jet
21. ou are under the influence of drugs or alcohol WARNING To reduce the risk of injury or drowning Consult your physician about pos sible side effects of any medications you may be taking before using the DAYBREAK Heat from the water in conjunction with some medications may cause drowsiness and increase the risk drowning Others can effect blood pressure heart rate and circulation WARNING To reduce the risk of injury It is especially important for persons over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulatory prob lems or diabetes to consult your physician before using this product If you feel pain or dizziness at any time while using the DAYBREAK discontinue use and contact a physician WARNING Read all instructions before using the DAYBREAK ICON assumes no responsibility for personal injury or property damage sustained by or through the use of this product SAVE THESE INSTRUCTIONS WARNING DECAL PLACEMENT The decals shown below have been placed on the DAYBREAK If a decal is missing or if it is not legible please call our Customer Service Department toll free at 1 800 999 3756 Monday through Friday 6 a m until 6 p m Mountain Time to order a replacement decal Apply the decal in the location shown AVOID DROWNING RISK STAY OFF COVER WILL NOT SUPPORT WEIGHT KEEP CHILDREN AWAY CHILDREN OR OBJECTS CANNOT BE SEEN UNDER C
22. oves in the Side Panel Remove the latch Attach the Buckle to the Side Panel with two Buckle Screws 23 Note It may be helpful to use a hammer and a nail to tap starter holes in the Side Panels You may also want to apply a little soap or wax to the screw threads Attach the other six Buckles 21 to the Side Panels 1 in the same manner 11 USING THE DAYBREAK The DAYBREAK is designed for up to four adults The six water jets can be regulated to provide a relaxing massage to sooth away stress and the strength of the water massage can be adjusted by the air control The DAYBREAK holds 170 gallons of water and offers an automatic programmable heating 70 F to 104 F and filtration system The guidelines below explain how to properly use the DAYBREAK Follow these guidelines to maintain the DAYBREAK for your long term enjoyment PRIMING THE SPA JET UNIT The water pump in the spa jet unit must be primed before you use the DAYBREAK the first time You must also prime the pump before using the unit each time you re fill the DAYBREAK PRIMER To prime the spa jet unit remove the primer cap from the console Fill the spa jet unit with at least 64 oz of water Replace and tighten the primer cap IMPOR TANT The spa jet unit may be seriously damaged if the pump is not properly primed or if the primer cap is not replaced and fully tightened PLUGGING IN THE DAYBREAK Once the DAYBREAK is filled wit
23. rect special or consequential damages arising out of or in con nection with the use or performance of the product or damages with respect to any economic loss loss of property loss of revenues or profits loss of enjoyment or use costs of removal installation or other consequential damages of whatsoever nature Some states do not allow the exclusion or limitation of inci dental or consequential damages Accordingly the above limitation may not apply to you The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of merchantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth herein Some states do not allow limitations on how long an implied warranty lasts Accordingly the above limitation may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state ICON HEALTH amp FITNESS INC 1500 S 1000 W LOGAN UT 84321 9813 IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of drowning electric shock or serious injury read the following important precautions before using the DAYBREAK READ AND FOLLOW ALL INSTRUCTIONS 10 11 12 It is the responsibility of the owner to ensure that all users of the DAYBREAK are ade quately informed of all precautions Use the DAYBREAK only as described in this manual The DAYBREAK is intended for home us
24. rol is set to front the flow will be through the hydro therapy jets when it is set to side the flow will be through the whirlpool diverter when it is set to all the flow will be evenly distributed through both the hydro therapy jets and the whirlpool diverter Thermostat Controls the temperature of the water The water heats at about 1 5 F an hour with the cover on The thermostat can be set to heat the water from LOW 70 F to 104 F You should use a medical or other accurate thermometer to check the temperature of the water On Off Turns the spa jet unit on and off To turn the spa jet unit on press the control once To turn the spa jet unit off press the control twice After you press it once the spa jet unit will shut off for about 30 sec onds and restart Press the control again The spa jet unit will remain off for three hours at which time it will begin running the filter cycle At any time after the spa jet unit has been shut off the pump will begin cycling the water if the temperature falls below the minimum setting Note To keep the filter and heat cycles from running the power cord must be unplugged Air Control Determines the amount of air that is in the spa jet system during operation If the control is turned to the left the amount of air flowing through the jets will increase If the control is turned to the right the amount will decrease SPA JET UNIT OPERATION The spa jet uni
25. t features five hydro therapy jets a whirlpool diverter a suction vent and a filter housing The five hydro therapy jets A located on the front of the spa jet unit focus the water massage on your neck and back The whirlpool diverter B located on the left side of the spa jet unit directs the flow of the water to create a whirlpool action in the DAYBREAK The suction vent C located on the right side of the spa jet unit pulls the water into the spa unit in order to operate the system The suction cover should always be in place over the suction vent Never operate the DAY BREAK without the suction cover in place The filter D is locat ed on the left side of the spa jet unit behind the Filter Cover 47 The filter can be removed for cleaning and replace ment by removing the Filter Cover and the two Filter Cover Screws 57 and then pulling the filter from the spa jet unit The spa jet unit features an automatic filter cycle and freeze protection If the spa jet unit has not been operated for three hours the pump will begin circulat ing the water for twenty minutes to filter any impuri ties Also if the water temperature falls below 40 F the pump will begin circulating and heating the water to prevent the water from freezing DRAINING THE DAYBREAK To drain the DAYBREAK you must use a garden hose to siphon the water Place one end of the hose in the DAYBREAK and hold i
26. t in front of a hydro ther apy jet until there is a flow of water coming out of the hose Turn off the spa unit and unplug the power cord The unit will be damaged if it is run without water circulating Be sure the end of the hose in the DAYBREAK is on the floor of the spa DRAINING THE PUMP After the DAYBREAK is drained see DRAINING THE DAY BREAK above the pump in the spa jet unit should also be drained if the DAY BREAK will be stored for more than thirty days or if it may be exposed to freezing temperatures To drain the pump remove the spa jet unit from the side panels Be careful not to tear the spa liner Locate the pump inside the spa jet unit Remove the indicated bolt from the pump Tip the spa jet unit slightly until all the water has drained from the pump Replace the drain plug MAINTENANCE CLEANING THE SPA LINER The liner should be cleaned with a mild soap solution Do not use solvents The liner should always be clean and dry before being moved or stored CHECKING AND CLEANING THE FILTER The filter should be checked periodically for build up of dirt and oil If the filter needs to be cleaned follow the steps below 1 Turn off the power 2 Remove the filter from the spa jet unit by pulling the white filter from the side of the spa jet unit Check the filter for any dirt or debris If the fil ter needs to be cleaned rinse the filter with a hose If the filter still is dirty you will nee
27. ttoms of the Edge Protectors 12 After the DAYBREAK is full you must prime the Spa Jet Unit 13 before using the DAYBREAK see PRIMING THE SPA JET UNIT on page 12 9 Insert the Support Ball 58 into the mesh pocket on the underside of the Spa Cover 11 Mesh Pocket See inset drawing A Insert the inflation tube into the hole in the Support Ball 58 Inflate the Support Ball See inset drawing B When the Support Ball 58 is inflated remove the inflation tube from the Support Ball and insert the ball plug through the mesh into the Support Ball The head of the ball plug will hold the Support Ball in place Note The Support Ball 58 is not a toy Inflation 9 Tube IS 4 Lx 299 Wi Ty WN ity WHY A rrr 188 IAE ML 04 YY MM Md yl HAS 199444 10 10 Place the Spa Cover 11 over the Side Panels 1 and the Spa Jet Unit 13 Be sure that the Spa Strap Cover is properly centered and that the corners of the Spa Cover line up with the corners of the Side Panels 1 Latch 23 A Snap a Buckle 21 onto each of the seven latches NS aoe on the Spa Cover 11 or See the inset drawing Position one of the Buckles 21 on the Side Panel 1 and hold the Buckle in place so the strap on the Spa Cover 11 is tight Note It may be easier to position the Buckles if a second person holds the strap on the opposite side of the Spa Cover tight Do not place the Buckle over one of the gro
28. uding holidays To help us assist you please note the product model number and serial number before calling The model number is SPRW52464 The serial number can be found on a decal attached to spa jet unit see the front cover of this manual Before reading further please familiarize yourself with the parts that are labeled in the drawing below A Floor Cap Locking Buckle CHOOSING A LOCATION FOR THE DAYBREAK There are many factors to consider when choosing a location to set up the DAYBREAK These factors vary depending on whether you use the DAYBREAK inside or outside We have listed several factors you may wish to consider as you decide where you want to use the DAYBREAK If you set up the DAYBREAK inside 1 The DAYBREAK will increase the level of humidity in your home The location you choose should be well ventilated You may need to install a ventila tion fan or use a dehumidifier The location must be close to an electrical outlet Do not use an extension cord with the DAY BREAK The DAYBREAK should be close to a source of water Do not use the DAYBREAK on carpet or other material that may be damaged by moisture We recommend that you place the DAYBREAK on a water and stain resistant non slip surface with a floor drain for any water that may splash from the DAYBREAK Be sure that the location you choose is stable It must be able to support the weight of the DAY BREAK when it
29. ump may have a foreign object stuck in the impeller Contact our customer service department or a local spa and pool service provider c The pump may have a loose wire connection Contact our customer service department or a local spa and pool service provider SYMPTOM THE PUMP HUMS BUT DOES NOT ROTATE a The pump may be jammed Contact our cus tomer service department or a local spa and pool service provider SYMPTOM THE PUMP IS NOISY WHILE OPERATING a There may be debris in the pump Contact our customer service department or a local spa and pool service provider b The pump may have a bad bearing Contact our customer service department or a local spa and pool service provider 6 SYMPTOM THE WATER DOES NOT HEAT 8 a The pump in the spa jet unit is the heater If the pump is operating the water should heat Cover the DAYBREAK with the spa cover The spa cover must be tight Set the air control to low The water will heat at a rate of 1 5 F an hour If you are using the DAYBREAK indoors and the room temperature is maintained at 70 F it will take approximately 36 to 48 hours for the water to reach the set temperature b If you are using the DAYBREAK outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 36 to 48 hours 50 F 70 F 2 to 4 days 30 F 50 F 4 to 6 days If the water still has not heated after six
30. use injury to users or damage to the spa jet unit and will void the warranty The water pump in the spa jet unit must be primed before you use the DAYBREAK the first time You must also prime the pump before using the unit each time you re fill the spa The spa jet unit may be seriously dam aged if the pump is not properly primed see PRIMING THE SPA JET UNIT on page 12 DANGER When connecting the power cord see PLUGGING IN THE DAYBREAK on page 12 plug the power cord directly into a grounded circuit capable of carrying 15 or more amps No other appliance should be on the same circuit Replace the power cord immediately if damaged Do not use an extension cord with the DAY BREAK This could damage the motor and will void the warranty DANGER If you will be using the DAY BREAK outside do not bury the power cord you should also keep the power cord away from lawn mowers hedge trimmers and other similar equipment WARNING The power cord is equipped with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord The GFCI must be tested before each use To test the GFCI press the test button while the spa jet unit is running The spa jet unit should shut off Press the reset button The spa jet unit should resume normal oper ation If the spa jet unit continues to run after the test button is pressed then the GFCI is damaged Do not use the DAYBREAK until the GFCI has been r