1. Do not return to place of purchase Please contact our Toll Free Hotline 866 985 7877 for customer service amp warranty issues Important Instructions 1 Read all instructions before using this heater 12 To prevent a possible fire do not block air intakes or exhaust in any manner Do not use 2 This heater will get very hot while in use To on soft surfaces like a bed where openings avoid burning do not let bare skin touch hot may become blocked surfaces If provided use handles when moving this heater Keep flammable materials 13 A heater has hot and sparking parts inside Do such as furniture pillows bedding papers not use it in areas where gasoline paint or cloths and curtains at least 3 feet 0 9m from flammable liquids are used or stored the heater 14 Use this heater only as described in this 3 DO NOT LEAVE heater unattended Extreme manual Any other use not recommended by caution is necessary when any heater is used the manufacturer may cause fire electrical by or near children or disabled persons and shock or injury to persons whenever the heater is left operating and unattended 15 Avoid the use of an extension cord because the extension cord may overheat and cause a 4 Always unplug heater when not in use risk of fire However if you have to use an extension cord use either a 12 or 14 gauge 5 Do not operate any heater with a damaged wire which is rated not less then 1900 watts cord or plug if
2. length Read This 4 Do not place any objects such as furniture papers clothing or curtains closer than 3 ft to the front and sides of the heater NOTE your IR Heater main body electrical components amp bracket comes fully factory assembled Do NOT attempt repair or disassembly contact our toll free customer service hotline for assistance For optimal performance and safety concerns we HIGHLY RECOMMEND that the Infrared Heater Head be operated at a min of 84 ht with a 45 55 degree angle of operational spread To Adjust The IR Head Unit Swivel head unit up or down to desired position The head unit must be at a 45 55 degree angle for optimal operation and output There should only be a moderate amount of tension to maintain the swivel bracket If it becomes too loose tighten cae hex nuts and bolts at swivel points on head unit bracket arae tos Fig 7 Creates a Note Be sure electrical cord is routed and positioned away from head unit Step 1 Before turning on your Infrared Heating System adjust the head unit angle as desired Do NOT touch the head unit during operation or for 30 minutes AFTER shut off The head units GETS VERY HOT v 1500W Quartz Halogen 4555 N Lamp Uses standard 110V household current AT Refer to coverage area in Fig 7 for best positioning location p and heat spread coverage SAFE for INDOOR p Applications
3. List This appliance MUST be grounded When using outdoors we recommend using a certified GFI Ground Fault Interrupt outlet to protect against electrical shock Ensure that the heater mounting bracket is SECURELY fastened to the wall patio overhang or house eave Route electrical cable AWAY from main body of heater which gets very hot Do NOT cover or obstruct the main body of the heater during use All Installations must be in accordance with E E safety regulations or equivalent If you are unsure consult an electrical service professional Avoid the use of an extension cord with this appliance Do not place any objects such as furniture papers clothing or curtains closer than 3 ft to the front and sides of the heater NOTE your IR Heater main body electrical components amp bracket are fully factory assembled Do NOT attempt to service or disassemble without proper instructions PARTS LIST 1 IR Head Unit w Protective Aluminum Shield Pre installed wall mount component Preassembled aluminum main heating unit w 1500W quartz halogen lamp swivel bracket amp 12 ft 16 3 grounded electrical cord 2 Wal Mounting Bracket 3 Hardware 4 threaded bolts screws phillips pan head 4 wall anchors 1 short set screw With aluminum shield 2 pre installed 16 3 grounded electrical cord wall mount Wa component Mounting e Bracket Page 3 Important Notice
4. Mojave l Suni Infrared Heater Wall Mount Owner s Manual Model MS 1500WOIRPH WM Another lifestyle enhancing product from Fine Sent Recommended Primarily For Sheltered EXTERNAL Use Do NOT expose to rain or moisture READ amp SAVE These Instructions Carefully read and review before attempting to assemble install operate or maintain this product Observe all safety instructions and information FAILURE TO FOLLOW WARNINGS amp OPERATIONAL INSTRUCTIONS CONTAINED IN THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND OR PERSONAL INJURY CERTIFIED For Residential Use Only Important Notice Do not return to place of purchase Please contact our Toll Free Hotline 866 985 7877 for customer service amp warranty issues SAVE THESE INSTRUCTIONS u u TRAVELED LIVING Web www wtliving com Well Traveled Living Email cservice welltraveled net Amelia Island FL 32034 Important Notice Fine Sense Do not return to place of purchase Please contact our Toll Free Hotline 866 985 7877 for customer service amp warranty issues Safety Guidelines Read this manual carefully for guidance on the assembly and use of this product A DANGER 4 WARNING Indicates a potentially hazardous situation which ndicates a potentially hazardous situation if not if not avoided WILL result in serious injury or avoided COULD resul
5. clips to touch the actual lamp tube The clips should be about at the center point of the end connectors when re assembled NOTES Page 9 Trouble Shooting Unit fails to turn on Check electrical plug connection at wall outlet for complete snug fit Check GFI circuit reset breaker if necessary Possibly connected to wall switch that is in off position Damaged halogen lamp call customer service hotline Head unit is loose or unsteady Tighten connecting bolts nuts at swivel bracket Head unit is hard to adjust Loosen connecting bolts nuts at swivel bracket Smoke appears from head unit Unplug IMMEDIATELY amp call customer service hotline eak light output from halogen lamp Life span of lamp has been reached or damaged lamp Call customer service hotline for assistance Well Traveled Living N Amelia Island FL 32034 wW o Web www wtliving com Toll Free 866 WTL SUPP ELL TRAVELED LIVI NG Email cservice welltraveled net 985 7877 or f S 1 YEAR LIMITED WARRANTY Customers in the Continental US All components are warranted for a period of 1 year after date of purchase by the original owner against defects in materials and workmanship under normal use This warranty does NOT cover normal wear and weathering assembly and or maintenance OR use in a commercial application At Well Traveled Living s sole discretion products under warranty will be repaired and or replaced at no charge to the customer Any returns sent back
6. e or a bungee cord For extreme weather conditions it is recommended that you remove the unit from the wall bracket and store in a safe dry indoor location When not in use for extended periods of time the IR Head Unit can be easily removed from the wall mounting bracket for storage indoors Refer to step 3 page 5 of this manual The halogen lamp is fragile be careful not to hit or jar the head unit Store in a dry location placing the head unit on a soft cushioned surface Make sure the electrical cord is properly coiled and out of the way Maintenance Your infrared heating system is virtually maintenance free A few minutes to wipe down exposed surfaces is all it takes Read This Head Unit amp Aluminum Shield Use any non abrasive cleaner and soft cloth to wipe off debris and dirt from the exposed surfaces of the aluminum shield and outer body of the head unit and outer grill NEVER spray any liquids or cleaners into the housing area where the halogen lamp is located Do not try to disassemble or clean the inner cavity where the halogen lamp is located Note For any maintenance on the head unit please call the toll free customer service hotline For halogen lamp replacement instructions refer to information on page 8 of this manual Page 7 Important Notice Do not return to place of purchasel Please contact our Toll Free Hotline 866 985 7877 for customer service amp warranty issue
7. er unit Fig 3 Min Clearances 83 head unit height 10 from mounting wall 12 from surfaces above Pilot hole anchors the heater head unit 1 5 8 depth are 36 from sides and front 92 Min of head unit 45 55 degree angle of operational spread Drill 5 16 wall Route power cord below and away from head unit as show in box 5 6 sme 3 5 Dt s 3 set screw to lock position J V X of head unit Correct Correct Wrong Page 5 Ceiling Important Notice Do not return to place of purchase z Please contact our Toll Free Hotline Op erating F ine f Sena 866 985 7877 Instructions for customer service amp warranty issues This appliance MUST be grounded When using outdoors we recommend using a certified GFI Ground Fault Interrupt outlet to protect against electrical shock Ensure that the heater mounting bracket is SECURELY fastened to the A wall patio overhang or house eave Route electrical cable AWAY from main body of heater which gets very hot CAUTION Do NOT cover or obstruct the main body of the heater during use i All Installations must be in accordance with E E safety regulations or equivalent If you are unsure consult an electrical service professional Avoid the use of an extension cord with this appliance If one is used it MUST be at least a 14 3 wire grounded cord 50ft max
8. lting from the use of this product or arising out of any breach of this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other legal rights which vary from state to state Fire Sense is a registered trademark of Well Traveled Imports Inc Fire Sense Assembly Instruction presentations are properties of Well Traveled Imports Inc and are protected by US Copyrights and Trademarks All Rights Reserved IR HEATER Hd Unit Manual QXP 01 07 Page 10
9. nto the friction clips see 4 Pull apart the clips slightly and gently push the connectors into place Do not allow the metal clips to touch the actual lamp tube The clips should be about at the center point of the end connectors Re install safety grill fits along grooves in housing body Then re insert vent panels by gently f pushing the end clips into housing body align clip ends close to lamp end connectors and push TYM output operation o into place Now re attach end plates make sure side with beveled holes faces out Clip ends must be aligned as close to end connectors of lamp tube when installed Do NOT allow to touch tube lamp itself Front Vent Panel End connectors ake sure heater Is DISCONNECTED from electrical outlet BEFORE beginning A _ approved original equipment replacement quartz halogen lamps to insure safe proper and maxi your infrared heater 5 lamp assembly Lamp Tube Connecting wire lead Metal friction clips Push apart sligtly to remove lamp tube end connectors wire lead terminal connector Remove amp Replace ENTIRE Lamp assembly including lamp end connectors amp wire lead NOTE do NOT allow any metal to contact actual lamp tube Using gloves gently re insert connector ends of the NEW lamp assembly into the friction clips see 4 Pull apart the clips slightly and gently push the connectors into place Do not allow the metal
10. s Contact toll free customer service hotline to order approved replacement lamps and parts NOTE do NOT touch the new halogen lamp with your bare fingers Oils from your hand could reduce the life of the lamp by causing a heat spot Recommend using Halogen Lamp Replacement clean cotton or plastic gloves A clean paper towel may also work Quartz Halogen Lamp Replacement Be sure unit is unplugged from wall outlet Remove head unit assembly from wall mounting bracket refer to step 3 from page 5 Remove 8 screws from each end of the head unit and pull off end plates see 2 Note the placement of the 2 small sheet metal screws on each end plate Also note end plate side with beveled holes faces outward when re assembled Pull out amp remove the left amp right front air vent panels and protective wire grill see 3 Note position of end clips on vent panel They must be aligned as close to end connectors of lamp tube as possible when re assembled Pull out and or pushed into place Do NOT allow any metal parts to touch the actual lamp tube when re assembled Gently pull out entire old lamp assembly from the clips at the terminal connection ends see 4 amp 5 Slide and lift the connection ends out from the friction clips by gently pushing apart the clips Unscrew wire leads from terminal Remove entire old lamp assembly Using gloves gently re insert connection ends of the NEW lamp assembly i
11. s Required 2 or 3 Phillips Screwdriver or standard slotted screwdriver adjustable wrench pencil 5 16 drill bit amp drill and a ladder Step 2 Find a suitable location to mount the heater unit be sure to comply with ALL minimum required distances and clearance specifications See illustration below fig 3 Do not place any objects such as furniture papers clothing or curtains closer than 3 ft to the front and sides of the heater Position mounting bracket flush against the wall where you want to position the IR unit Make sure the bracket is level and mark the centers of the holes with a pencil Note the proper upright orientation of the bracket see fig 1 Drill 4 pilot holes approx 1 5 8 deep For mounting on stucco walls and or locations where there is not a wood stud be sure to use appropriate wall anchors to properly secure mounting bracket to wall Attach wall bracket using the 4 screws included and wall anchors if applicable Apply all 4 screws loosely at first check that the bracket is level and then tighten securely Step 3 Insert wall mount assembly from head unit into wall mount bracket See fig 2 Note orientation of bracket and head unit Align and apply small set screw to bottom of wall bracket and thru the wall mount of the head unit to lock head unit into place Tighten securely IMPORTANT NOTE be sure to route and keep the electrical cord AWAY from the main body of the heat
12. t in serious injury or death death CAUTION NOTICE Indicates a potentially hazardous situation which Indicated important information that if not if not avoided MAY cause moderate injury or followed may cause damage to the equipment damage to the equipment DANGER 1 ae Risk of Fire There is always a risk of fire when working with a heater Keep heater away from flammable liquids and materials 2 i Risk of Fire If falls over this unit might start a fire Follow instructions above and also for further prevention keep this unit at least 3 feet 9m away from everything 3 ibd Hot or Burn Hazard This unit may be extremely hot while in use Careful when handling especially around the head of the unit 4 Y Electrical Hazard Disconnect from electrical outlet before working on the unit to avoid chance of electrical shock 5 Electric Shock Do not use near water Do not use if cord has been damaged A CAUTION e Improper treatment of the heater can damage it and also shorten its life span e To prevent electrical shock ensure electrical plug is properly inserted into the electrical outlet Page 2 Important Notice Do not return to place of purchase Please contact our Toll Free Hotline Recommended Primarily For Sheltered EXTERNAL use m Do NOT expose to F Sense rain or moisture 866 985 7877 for customer service amp warranty issues Product Components amp Parts
13. the heater malfunctions or has The recommended length for a 14 gauge is 0 been dropped or damaged in any manner 50 feet but if need be long use a 12 gauge no Return heater to authorized service facility for longer then 100 feet repairs 16 SAVE THESE INSTRUCTIONS for future 6 Can be used indoors or outdoors operate 3 reference feet 0 9m from people or objects 7 Never operate heater near water or where it can be knocked over 8 Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Arrange cord away from traffic area and where it will not be tripped over 9 To disconnect heater remove plug from electrical outlet 10 Connect to properly grounded outlets only 11 Do not insert or allow foreign objects to enter ventilation or exhaust opening doing so may cause an electrical shock or fire or may damage the heater Page 4 Important Notice Do not return to place of purchasel Please contact our Toll Free Hotline 866 985 7877 for customer service amp warranty issues Assembly Fine f Sena amp Installation ea al oun Ste 1 with mounting p bracket attached Be sure to read and familiarize yourself with the overall assembly and installation instructions in this manual before beginning It may be helpful to have someone assist you with the installation This unit is primarily designed for outdoor applications Tool
14. to the manufacturer must be sent via prepaid freight Insure prompt warranty service return the enclosed warranty registration card within 30 days For warranty service contact Well Traveled Living at the address phone numbers or internet site and e mail listed in this owner s manual Be sure to have your sales receipt and original date of purchase All warranty service will be coordinated by the Well Traveled Living Amelia Island Florida service center This warranty is extended only to the original purchaser Proof of purchase will be required before warranty service is rendered Sales receipt and or validation of warranty registration are valid forms of proof of purchase This warranty only covers failures due to defects in materials or workmanship which occur during normal use Failures and or damage which result from accident negligence misuse abuse neglect mishan dling alteration or modification failure to maintain improper assembly or maintenance service by an unauthorized agency or use of unauthorized components or damage that is attributable to acts of God are NOT covered There are no express warranties except as listed above Purchaser assumes all risks in the assembly and operation of this unit FAILURE TO FOLLOW WARNIN PERATIONAL INSTRUCTION NTAINED IN THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND OR PERSONAL INJURY Well Traveled Living shall not be liable for incidental or consequential damages resu
15. too Step 2 The infrared electric heating system comes equipped with a heavy duty 16 3 gauge wire and grounded plug This appliance must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances Make sure that the heater is connected to an outlet having the same configuration as the plug shown in Fig 8 Do NOT use an adapter with this product Check with a licensed electrician if the grounding instructions are not understood completely or if the wall outlet does not match the plug Step 3 Always UNPLUG unit when not in use Your Mojave Sun infrared electric heating system is ready to enjoy Plug the appliance in and beginning enjoying the warmth Page 6 Important Notice Do not return to place of purchase Please contact our Toll Free Hotline Maintenance amp F ine Some 866 985 7877 Storage for customer service amp warranty issues Specifications Model MS 1500WOIRPH WM Voltage 120 volts ays Amps 12 5 amps AVA Wattage 1500 watts Lamp Type Quartz Halogen Min Operational Height 84 7 ft Weight 5 5 Ibs Head Unit Dimensions 4 5 x 7 x 22 Storage Always UNPLUG unit when not in use The IR Head unit can be left outside during the season as long as it is mounted under a covered protected location During expected moderate weather conditions we recommend wrapping the head unit with a poly bag and tap