1. The Welch Allyn Propag LT Continuous Monitoring for Ambulatory Bedside and Transport Applications The Propag LT is specially designed to extend continuous amp monitoring capabilities to care areas where technical complexity or cost made it impossible in the past Frontline caregivers all over the world are caring for growing numbers of more acutely ill patients At the same time a critical shortage of clinicians face increasing requirements for higher care standards and regulations How will today s healthcare providers meet these increasing challenges With advancements in technology that offer new paradigms of care The Propag LI marks such an advancement For a little more than half the price of a traditional bedside monitor the Propaq LT allows caregivers to extend continuous monitoring to areas never covered before Appropriate for transport ambulatory and bedside monitoring applications the Propaq LT has the versatility to meet your needs Its simple and highly intuitive user interface allows highly skilled or less skilled clinical staff to operate the monitor with ease The Propag LT can even be uniquely configured for a particular care area With all this the new Propaq LT is the perfect solution for today s fast paced frontline hospital environment Our most compact rugged and versatile Propag monitor to date the Propag LI features e A compact design weighing less than 1 kilo about the size of the ave
2. All Propag vital signs monitors come standard with smartcuf technology a new standard in NIBP accuracy This patented software offers industry leading performance and accuracy in the presence of motion artifact This monitor is approved for use during all phases of flight aboard U S Army aircraft MIL STD 461E Army CE101 CE102 CS101 CS114 CS115 CS116 RE102 RS103 Jasmo SET Only Masimo SET SpO sensors including LNCS series of cables and NR value disposable sensors should be used with Masimo pulse oximetry Masimo Masimo SET LNCS and NR are registered trademarks of Masimo Corporation NELLCOR Only Nellcor OxiMax pulse oximetry sensors should be used with the Nellcor pulse oximetry option Nellcor and OxiMax are registered trademarks of Nellcor Puritan Bennett Inc UK Customer Services Welch Allyn UK Ltd Cublington Road Aston Abbotts Buckinghamshire HP22 4ND England Tel 44 0 207 365 6780 Fax 44 0 207 365 9694 South Africa Customer Services Welch Allyn SA 394 Surrey Avenue Ferndale 2194 P O Box 809 Fontainebleau 2032 south Africa Tel 27 11 777 7555 Fax 27 11 777 7556 Welch Allyn European Customer Services Navan Business Park Dublin Road Navan Co Meath Republic of Ireland Tel 353 46 90 67790 Fax 353 46 90 67754 2007 Welch Allyn All rights reserved Acuity Propag and Smartcuf are registered trademarks and FlexNet is a trademark of W
3. Hz extended mode Paediatric neonate 0 5 to 80 Hz monitor mode 0 05 to 80 Hz extended mode Hypertronics connector Heart rate measurement range 25 to 300bpm display Heart rate accuracy 3bpm or 3 Pacer detection and display Electrosurgery and defibrillator protected Sweep speed 25 mm sec 6 25 mm sec respiration only User selectable size mV cm 8 4 2 1 0 5 0 2 QRS tone med low off e 3 0 sec waveform duration at 25 mm sec for single waveform 6 0 sec waveform duration at 25 mm sec for cascading waveform QRS detector range Adult or paediatric mode 0 22 to 5 0 mV RTI Neonatal mode 0 1 to 5 0 mV Neonatal width 40 to 120 msec Paediatric width 40 to 120 msec Adult width 70 to 120 msec NIBP Oscillometric method e Automatic intervals between 1 to 60min and manual modes Quick action NIBP start stop button TurboCuf 5min of repeated NIBP readings systolic diastolic and mean display On screen manometer e Store and view up to 150 readings Standard cuff sizes Neonates 1 to 5 infant child small adult adult large adult thigh Cuff overpressure protection Typical measurement time 30 to 45 sec smartcuf motion tolerant NIBP technology Blood pressure range Adult systolic 30 to 260 mmHg Diastolic 20 to 235 mmHg Mean 20 to 255 mmHg Paediatric systolic 30 to 160 mmHg Diastolic 15 to 130 mmHg Mean 15 to 140 mmHg Neonate systolic 25 to 120 mmHg Diastolic
4. 10 to 105 mmHg Mean 10 to 110 mmHg e Blood pressure target inflation Adult 160 mmHg Paediatric 120 mmHg Neonate 90 mmHg e Pulse rate accuracy 3 bpm or 3 e Pulse rate range 30 to 220 bom p0 Masimo e Masimo SET technology e Perfusion Index and Signal IQ display e Sensitivity modes Normal MAX APOD e Masimo SET sensors e Waveform and pulse amplitude meter e Pulse tone pitch indicator e Saturation range 1 to 100 e Probe accuracy 25 to 41 C No motion Adult Paediatric 70 to 100 2 digits 0 to 69 unspecified Neonatal 70 to 100 3 digits 0 to 69 unspecified During motion Adult Paediatric Neonatal 70 to 100 3 digits 0 to 69 unspecified e Pulse rate measurement range Adult Paediatric Neonatal No motion 26 to 239 bpm During motion 26 to 239 bpm e Pulse rate accuracy No motion 3 digits During motion 5 digits p0 Nellcor Nellcor OxiMax sensors e Waveform and pulse amplitude meter e Normal fast and slow response modes e Saturation range 1 to 100 e Accuracy Probe 70 to 100 28 to 42 C Adult Paediatric digit 2 counts Neonate digit 3 counts e Pulse rate accuracy no motion 3 bpm e Pulse rate range 25 to 300 bpm Respiration e Breath rate source impedance pneumography e Two user selectable leads RA LA RA LL e Automatic cardiovascular artifact CVA rejection e Respiration rate range Adult Paediatric modes 2 to 150 br m Neon
5. ate mode 3 to 150 br m e Respiration detection threshold 175 milliohms or 2X CVA whichever is greater e Respiration rate accuracy 2 br m or 2 e Sweep speed 6 25 mm sec Physical e Monitor Height 137 1 mm Width 190 5 mm Depth 53 3 mm Weight 904 3 g with FlexNet radio 765 g without radio e Charging station Height 144 7 mm Width 193 mm Depth 152 4 mm Weight 680 3 g e Colour display e 3 5 in colour transflective LCD e Viewable in direct sunlight Environmental e Operating temperature 0 to 40 C e Operating relative humidity 5 to 95 noncondensing e Monitor operating altitude 610 to 4 572 m e Cradle operating altitude 152 to 4 572 m e Shipping storage temperature 20 to 60 C e Shock 75 g e Vibration Random and Sinusoidal designed to meet RTCA DO 160D categories section 8 modified e Electromagnetic compatibility EMC per IEC 601 1 2 Drip proof per IEC 529 level IPX1 Power e Rechargeable lithium ion internal battery pack External recharger e Input voltage 12 to 28 VDC e AC power adapter 110 and 220 V DC vehicle conversion e Operating time on battery typical ECG Resp only 24 hours ECG Resp SpO and NIBP 8 hours e Battery recharge time lt 3 hours Performance may vary based on monitor configuration and battery condition Fully charged new battery at 25 C NIBP every 15 minutes display and backlight operating in power save mode Communicatio
6. elch Allyn Other product and company names mentioned herein are for identification purposes only and may be the trademarks or registered trademarks of their respective companies SM2833EU Rev E WelchAllyn Advancing Frontline Care
7. ns e PC Utility USB interface via charging station Supports Microsoft Windows XP 2000 and later Autoprint utility allows printing of tabular trends and snapshots to connected laser printer e Acuity Central Station Wireless FlexNet Network 802 114 5 GHz Able to operate on shared 802 11a b g network Alarms e All parameters upper lower limits specific to patient mode e Factory default or programmable settings for all patient modes e Alarm indicator red e Alarm s off indicator yellow e Audible alarm tone high med low e Alarm silence reset 90 sec Qne button Param set for adjusting specific parameter alarm limits programmable Equipment alert yellow Trends e Tabular numeric and graphical formats All parameters trended viewable e Resolution non NIBP trends entered every 1 min e NIBP trends entered after each reading e Duration 24 hr non NIBP trends up to 150 NIBP readings e Page up down trend view e Up to 20 data snapshots 7 sec behind and 14 sec ahead of snapshot event of displayed data captured Certifications Standards e Complies with all relevant AAMI IEC EN CSA and UL standards CE marked according to the European Medical Device Directive CSA certificate of compliance for use in the U S and Canada Warranty e Monitor and recharger two years e Accessories 90 days Extended warranties available All specifications subject to change without notice
8. rage paperback book Shock resistance of up to 75 g enough to withstand a 1 8 m drop Heart rate 3 or 5 lead ECG SpO NIBP respiration Neonatal paediatric and adult patient modes Masimo SET motion tolerant SpO or Nellcor SpO Highly intuitive easy to use user interface Custom configurable to user care area Operates in spot check and or continuous monitoring modes Direct action operation with camcorder type controls Three display modes to accommodate varying user skill sets Colour Transflective LCD viewable indoors and outdoors 24 hour tabular and graphical trending Stores up to 20 full disclosure data snapshots Transfers trends and snapshots to PC for printing Wireless connectivity option to Acuity Central Station via FlexNet Smartcuf NIBP e U S Military flight certified for fixed and rotary wing aircraft WelchAltyn Advancing Frontline Care Propag LT Specifications General e Available in two configurations Standalone model 802LTON Networked via wireless radio model 802LTRN Adult paediatric and neonatal patient modes Electrosurgery interference suppression ESIS all channels except impedance respiration All channels electronically isolated ECG Automatic 3 and 5 lead monitoring and cable type detection selectable leads Il Ill aVR VL VF V Lead fault detection and autoconfigure e Bandwidth Adult 0 5 to 80 Hz monitor mode 0 05 to 80
Download Pdf Manuals
Related Search
Related Contents
Boîte à trucs USER`S MANUAL Graco PD250304A User's Manual Samsung SEW-HDR145R User Manual Philips 32HFL3331/93 Flat Panel Television User Manual MASF User`s Manual (1).cdr ZPX04/08 User's Manual Porta-Davit500-Qualité F Wheel end bearing and seal installation guide Cisco IP Phone SPA504 Basic User Guide Copyright © All rights reserved.