Home

Wayne 351301-001 User's Manual

image

Contents

1. 237 0987 Please provide following information Address parts correspondence to Model number Wayne Water Systems Serial number if any 100 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A Description 1 Power cord 2 Discharge fitting 3 Outer housing with o ring 4 Impeller Volute gasket 6 Volute cover with screen TSC130 250 31006 002 15875 28053 001 19023 001 23097 23122 28056 001 TSC160 31006 002 15875 002 28053 001 19023 001 23097 23122 28056 002 Ne Operating Instructions and Parts Manual Limited Warranty For one year from the date of purchase Wayne Water Systems Division Wayne will repair or replace at its option for the original purchaser any part or parts of its Sump Pumps or Water Pumps Product found upon examination by Wayne to be defective in materials or workmanship Please call Wayne 800 237 0987 for instructions or see your dealer Be prepared to provide the model number and the serial number when exercising this warranty All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser This Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayne s written instructions THERE IS NO OTHER EX
2. Operating Instructions and Parts Manual TSC Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or prop erty damage Retain instructions for future reference Description This portable submersible utility pump is designed for non automatic use in water The units are equipped with an 8 ft 3 prong grounding type power cord The motor is oil filled and sealed for cooler operation The discharge fit ting is designed for convenient attach ment to a garden hose IMPORTANT THIS PUMP IS NOT SUITABLE FOR AQUATIC LIFE Unpacking After unpacking the unit carefully inspect for any damage that may have occurred during transit Check for loose missing or damaged parts Very Important Safety Information Danger indicates ADAN G E i an imminently haz ardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially haz ardous situation which if not avoided COULD result in death or serious injury Caution indicates a CAU TI 0 N potentially haz ardous situation which if not avoided MAY result in minor or moderate Notice indicates important informa tion that if not followed MAY cause damage to equipment S J This manual c
3. PRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited warranty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall Wayne or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of prof it or revenues loss of use of the products or any associated equipment damage to associated equipment cost of capital cost of substitute products facilities services or replacement power downtime costs or claims of buyer s customers for such damages You MUST retain your purchase receipt along with this form In the event you need to exercise a warranty claim you MUST send a copy of the purchase receipt along with the material or correspondence Please call Wayne 800 237 0987 for return authorization and instructions DO NOT MAIL THIS FORM TO WAYNE Use this form only to maint
4. ain your records MODEL NO SERIAL NO INSTALLATION DATE ATTACH YOUR RECEIPT HERE
5. he pump Follow the cleaning Dancealiod steps listed below ANOTKE pump to run dry The shaft seal depends on water for lubrication Operating pump without b Remove the 3 screws at the bot water will damage the shaft seal and tom of the pump cause pump failure c Remove the volute cover Note Maintenance the alignment marks DANGER Always disconnect electric supply before attempting to a Unplug the power cord d Remove the gasket Note how the openings in the gasket align with the openings in the pump install service relocate or per base form any maintenance Failure to do so could result in fatal electrical shock e Remove the debris and make sure Minimal service is required for this the impeller turns freely pump If pump should fail to operate perform the following troubleshooting guidelines 1 The motor housing of the pump is completely sealed and requires no service Sf 25 Ft Max Disassembly of the motor l housing or alteration of the power cord could result in fatal electrical shock 2 Verify pump is operating correctly a Disconnect pump from power source b Disconnect discharge hose from pump Water Level c Immerse pump in a bucket or tub of water d Plug power cord into a grounded 115 volt AC power outlet If pump operates correctly proceed to step 3 If pump does NOT Figure 1 Water Level Operating Instructions and Parts Manual For Replacement Parts call 1 800
6. ontains information that is very important to know and under stand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following _ Read these rules and instructions carefully Failure to follow these instructions could cause serious bodily injury and or proper ty damage 2000 Wayne Water Systems Pump Do not pump flammable or explosive fluids such as gaso line fuel oil kerosene etc Do not use in a flammable andlor explosive envi ronment Pump only clear water Personal injury and or property dam age will result DANGER Risk of electric shock This pump has not been tested for use in swimming pool areas Never place pump in pools while people are in the water DANGER Do not handle pump with wet hands or when standing in water or on a damp surface DANGER Risk of electric shock This pump is supplied with a grounding conductor and grounding type attachment plug Use a grounded receptacle to reduce the risk of fatal electrical shock This pump con tains dielectric motor oil for motor heat transfer Care should be taken when disposing of this oil Do not use this pump in ponds or fountains because the motor oil can be harmful to aquatic life yy YY Wear safety glasses at all times when working with pumps TO Ww It is strongly recommended that this unit be plugged into a Ground Faul
7. t Circuit Interrupter GFCI Consult a local electrician for installation and availability Do not use the power cord or dis charge hose to carry or handle the pump Damage to the power cord or discharge hose may occur Use the lifting ring supplied on the pump Submersible Utility Installation and Operation ee DS A Always disconnect electric supply before attempting to install service relocate or perform any maintenance If the power source is out of sight lock and TAG IN OPEN OFF POSITION to pre vent unexpected power application Failure to do so could result in fatal electrical shock This unit is not designed for use in septic tanks or under ground vaults to pump raw sewage or effluents Never use in hazardous or explosive locations 1 This pump has been designed to attach to a standard garden hose Thread the female end of the gar den hose to the male discharge on the pump 2 To reduce leakage between the pump and the hose place a hose washer not included on the gar den hose before installing to the pump 3 For best pump performance unwind the hose before starting the pump This will help remove any kinks or binds in the hose and allow the unit to pump with less restriction 4 Set the pump on a hard surface in the water Do not set the pump directly on mud or sand surfaces This will cause the inlet screen to clog 5 The water level must be at least 1 2 inches for the p
8. ump to operate Water levels less than 1 2 inches will not allow the impeller to contact water and no water will be pumped 351301 001 1 00 Operating Instructions and Parts Manual Installation and Operation operate unplug power cord and f Replace the gasket making sure Continued proceed to maintenance guide the openings are aligned line item 4 in this section DANGER Do not handle pump with wet hands or when standing in water or on a damp surface when the g Replace the volute cover 3 Verify discharge hose is correctly installed h Replace the 3 screws a Connect hose to another water unit is operating or fails to operate source such as a faucet If water Always disconnect pump power cord flows through hose proceed to from power source before handling step 3b If water is restricted ver 6 Plug the power cord into a ground ify discharge hose is unwound ed 115 volt AC power outlet The Remove all kinks bends or pump will start operating as soon as en eee the power cord is plugged into the obstructions in hose power outlet b Verify pumping height does NOT 7 The pump will remove water down exceed 25 feet See Figure 1 If to 1 8 inches of the hard surface the pumping height is greater than pump was placed on 25 feet this pump will NOT work 8 The pump should be turned off 4 Periodic cleaning of pump is once the water level reaches the required to maintain performance 1 8 inch mark of t

Download Pdf Manuals

image

Related Search

Related Contents

Addictions sans substance. Guide Repère(s.  Baixe - Pioneer  DV04T_FN-93_NCL β2-M尿std.indd    取扱説明書 - Pivot  Isséo N°17 - Fév. 2015 - Silene  LA HAUTE – SAVOIE  Operator manual - ALE  Controlador de Interrupciones (Versión programable) Manual  取扱説明書 - 三菱電機  

Copyright © All rights reserved.
Failed to retrieve file