Contents
1. Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation of the device Cet appareillage num rique de la classe B r pond a toutes les exigences de l interference canadienne causant des r glements d quipement Lop ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interference re ue y compris l interference qui peut causer l op ration peu d sir e WARNING Changes or modifications to this receiver not expressly approved by Wayne Dalton Corp could void the user s authority to operate this equipment Copyright 2008 Wayne Dalton Corp Part No 0002906 Rev A New 09 23 08 For Assistance you may reach us online at www wayne dalton com access Printed in China
2. Way Application with 3 Way Remote Switch 18 ga MIN not supplied 0 HOT M A 4 5 3 Way Switch 120VAC Incandescent 50 60 Hz Lighting Load NEUTRAL 3 Switch Application Incandescent Lighting Load HOT A BLACK a 4 3 Way 3 Way 120VAC a Switch Switch 50 60 Hz j NEUTRAL HA14WD 4 Switch Application Incandescent Lighting Load 3 Way 4 Way 3 Way Switch Switch Switch b Common Incandescent m Lighting Load 3 Way 4 Way 4 Way 3 Way Common 120VAC B Switch Switch Switch Switch 50 60 Hz NEUTRAL HA14WD uo1 ejje su Installation Installation continued 3 Trim wires to 7 16 inch as shown in the adjacent diagram 4 Connect the BLACK wire of the HA14WD switch to the 120V HOT building wire the wire leading to the circuit breaker or fuse box using a twist connector provided NOTE nsert wires straight into the twist connector the twist clockwise Make sure all twist connectors are tight Secure each twist connector with electrical tape Verify no bare wire shows below the wire connector 5A FOR SINGLE POLE APPLICATION ONLY Connect the BLUE wire of the HA14WD to the LOAD wire using a twist connector provided 5B FOR 2 3 and 4 SWITCH and MULTI WAY APPLICATIONS Connect the BLUE wire of the HA14WD to the LOAD wire of the lighting load using a twist connector provided NOTE An additional wire run ma
3. ah Wayne Dalton Z Wave enabled 3 Way 600 Watt In Wall Dimmer Switch User Manual For Model HA14WD Thank you for purchasing the Z Wavee Enabled 3 Way 600 Watt In Wall Dimmer Switch Z Wavee products by Wayne Dalton allow you to manage and control your home by remote control for convenience comfort safety and energy conservation Your Z Wave Enabled 3 Way 600 Watt In Wall Dimmer Switch features 600 Watt capability for single pole or 3 way applications such as chandeliers foyer lights and outdoor flood lights and is a great addition to your Z Wavee network for lighting control In addition to indoor and outdoor lighting switches thermostats security systems garage door openers and window shades are just a few of the items you can easily control with additional Z Wavee certified products Your new Z Wavee Enabled 3 Way 600 Waitt In Wall Dimmer Switch is compatible with the complete range of Wayne Dalton Z Wavee certified controllers and will also work with Z Wavee certified controllers from other manufacturers and brands Please consult the user manual and your controller supplier for specific details SPEAKS Wave 71 Products that speak Z Wave work together better Home Control Basics Z Wave certified products will allow you to easily control multiple devices in a home with the push of a button in what is known as a scene Turning on your home s interior lights and activating the set
4. back on your thermostat from your in vehicle remote as you come home is an example of a scene Dimming the lights and automatically closing your curtains to watch TV with a single push of a button is another example of a scene To begin using Z Wavee Home Control technology it is helpful to understand that each Z Wavee module including the Z Wavee Enabled 3 Way 600W In Wall Dimmer Switch communicate with each other using a low power radio transmitter and receiver Large metal objects house wiring walls furniture refrigerators microwaves and similar items can interfere with communication between the modules to reduce the range or even prevent communication Placement of the Z Wavee Enabled 3 Way 600W In Wall Dimmer Switch and other Z Wavee modules is very important to obtain a reliable network A Z Wavee network is a collection of Z Wave modules in a mesh type of network Each Z Wavee module regardless of manufacturer communicates with other modules within range to route and repeat the signals from one device to the next this creates a highly reliable and robust transmission throughout the home In addition the network becomes stronger as more modules are added A Z Wavee network can have only one primary controller The primary controller establishes network security to ensure your network will not operate a neighbors network and vice versa It is a good practice to label and protect your primary controller since it is the only Z Wavee contro
5. d Z Wave programming support please e mail homesettings wayne dalton com Additional product information and general information on Wayne Dalton Home Control products may be found on our web site at www wayne dalton com access FCC and IC Statement FCC Regulatory Information NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures a reorient or relocate the receiving antenna b increase the separation between the equipment and receiver c connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help IC Regulatory Information This Class B digital apparatus meets all requirements of the Canadian Interference
6. ene in ON position INCLUDE EXCLUDE to Network or Press and Hold to ADD into Scene scene at specific DIM level Release at Press and Release to ADD into desired level Scene in OFF position Press and Hold to ADD into Scene at desired DIM level Release at desired level Troubleshooting Light does not turn ON e Lamp bulb is burned out Replace e Air Gap switch is in OFF position Move slide switch to left e Wire connection is broken Following all safety precautions remove switch and check all connections e Circuit breaker or fuse has tripped Reset Replace Light flickers e Lamp bulb is not screwed in properly Check and tighten e Wire connection is intermittent Following all safety precautions remove switch and check connections 3 Z Wave controller will not operate switch e Lamp bulb is burned out Replace e Switch was programmed in the OFF position Reprogram to ON position e Air Gap switch is in OFF position Move slide switch to left e Switch is not programmed to Network or Scene Reprogram Huiwweib01g Uu0le e Su Compliance Customer Support Technical Specifications TECHNICAL SPECIFICATIONS For control of permanently installed incandescent lamp fixtures only Ratings 600 Watts tungsten 40 Watts minimum 120 VAC 50 60 Hz De rating 500 Watts double gang 400 Watts triple gang Operating temperature range 32 F 104 F 0 C 40 C CUSTOMER SUPPORT For Installation an
7. lete modules from a network It is recommended that you mark the primary controller for each network for ease in modifying your network Replicate Copy from one controller to another Scene A scene is a Series of Z Wave modules programmed to turn to a specific level on off or dim normal mode save mode etc with the push of a button on a controller Schedule A timer based event in the software that will activate a scene or turn on off a zone at a specified time of day or at sunrise or sunset Secondary Controller A controller containing network information about other modules within the network and is created FROM the primary controller Secondary controllers cannot include or delete modules to the network INSTALLATION e ELECTRICAL SHOCK HAZARD RISK OF INJURY OR DEATH DISCONNECT ELECTRICAL POWER AT SERVICE PANEL BEFORE INSTALLING AND TEST THAT POWER IS OFF BEFORE WIRING WARNING FOLLOW LOCAL ELECTRICAL CODES DURING INSTALLATION e FOR INDOOR USE ONLY 2 Match your wiring application to the one of the diagrams below and refer to it for the remainder of the installation Single Pole Applicatio o M HoT BLACK BLUE JN LOAD 4 i RED Incandescent BARE _ Lighting Load gp COPPER HA14WwD m 2 Switch 3 Way Application with Single Pole Remote Switch incandescent Lighting Load BARE 120VAC COPPER 50 60 Hz PE R HA14WD 2 Switch 3
8. ller that can add modules to or remove modules from your network It is easy to add secondary controllers as your network grows Your Z Wavee Enabled 3 Way 600W In Wall Dimmer Switch can belong to only one network and therefore only one primary controller but it can be added to as many secondary controllers or Z Wavee scenes as you wish for added convenience For more tips and great ideas on how to create set up and use scenes for safety security comfort convenience and expand your network please visit our web site www wayne dalton com access __ _ _ _ _ eee IMPORTANT NOTICE Read the enclosed instructions carefully before installing your new Z Wave Enabled 3 Way 600 Watt In Wall Dimmer Switch Pay close attention to all warnings and notes and carefully follow the installation steps in the order they are presented to save time and minimize the risk of damaging the switch or the system it controls This manual should be retained for future reference Glossary Warnings Table of Contents Table of Contents Introduction and Z Wave Home Control Basics Table of Contents Warnings and Glossary Installation Programming Operation Troubleshooting Technical Specifications Compliance Warning IMPORTANT WARNINGS and SAFETY INSTRUCTIONS 1 Heed all warnings 2 Read and follow these instructions 3 Keep these instructions for future reference 4 lf yo
9. p switch This disconnects electrical power to the light fixture to prevent an electrical shock When the bulb has been replaced slide the switch back to the ON position OFF Indicator INSTALLATION INSTRUCTIONS CONTINUED ON NEXT PAGE Installation continued 10 Test switch by pressing the upper part of the rocker switch to turn the lights ON and pressing the lower part of the rocker switch to turn the lights OFF The lights should turn ON and OFF If lights do not turn on refer to the TROUBLESHOOTING section 11 Upon successful testing finish mounting the HA14WD unit to the wall box with the screws provided and install a decorator wall plate not provided Programming Operation Refer to your specific controller s user manual for detailed instructions on adding modules devices to a Z Wave network Refer to diagram below for control and programming functions of switch LED A LED ON indicates switch is ON B LED flashing indicates switch is Top of Rocker switch communicating with Z Wavee network A Press and Release to turn light ON Press and Hold to DIM light up to Bottom of Rocker switch specific level Release at desired A Press and Release to turn light OFF level B Press and Hold to adjust DIM level Press and Release to INCLUDE to desired level Release at desired EXCLUDE to Network or Scene level Press and Release to ADD into Alternate Press and Release to sc
10. u are unsure about any part of these instructions consult a qualified electrician or use a qualified electrician for this installation 5 Use this device only with copper or copper clad wire 6 3 Way switch applications may require an additional wire to be run refer to the wiring diagrams for further instruction 7 To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle a motor operated appliance a fluorescent lighting fixture or a transformer supplied appliance GLOSSARY Copy See Replicate Delete Erase transmitter or scene information from Controller Also known as Exclude Device Any item that is connected to a module for example lamps Exclude Remove a module transmitter or scene from the controller Include Add a module to the controller Also known as Inclusion Module Any Wayne Dalton or Z Wavee product that is controlled with a Wayne Dalton or Z Wavee remote controller A module can be part of more than one scene Network A collection of Z Wavee modules controlled by primary and secondary controllers operating on the same system A network has its own unique identification code so that no one else can control the system Node Single Z Wavee endpoint controller or module on a network Primary Controller The first controller used to set up your modules and network NOTE Only the Primary Controller can be used to include or de
11. y be necessary in multi switch applications to connect the HA14WD directly to the lighting load as shown in the wiring diagrams Consult with a qualified electrician if you are unsure about any part of the installation 6 Connect the ground wire from the box to the bare copper wire on the HA14WD switch If there is no ground wire connect the bare copper wire of the HA14WD to the wall box if it is metal If the wall box is plastic connect the bare copper wire to ground as supplied or consult with a qualified electrician 7A FOR SINGLE POLE APPLICATION ONLY Remove the semi stripped end of the RED wire and apply the twist connector to this wire without any connecting wire 7B FOR 2 3 and 4 SWITCH and MULTI WAY APPLICATIONS Connect the RED wire to the COMMON wire aka traveler of the next switch in the circuit 8 Tuck wires into wall box leaving room for the HA14WD unit For testing purposes partially screw mounting screws provided of the HA14WD into the wall box 9 Restore electrical power to the circuit NOTE Before operating the switch be sure the air gap switch small slide switch located below the rocker switch is in the ON position The switch is in the ON position if the vertical line ON symbol is visible to the right of the air gap switch NOTE When changing a light bulb slide the air gap switch to the OFF position The OFF position is indicated if there is an O OFF symbol visible to the left of the air ga