1. 6 Product name sent to the Jandy AquaLink RS display AL 0 which signifies Aqua Rite 7 Software revision level rl xx On the 8th push of the button the display will revert back to the default salt display Also if the button is not pushed for 30 seconds the display will revert back to the standard salt display Common Problems and Solutions 1 Power LED not on Check to make sure either 120VAC or 240VAC input power is connected to the proper screw terminals at the Aqua Rite control Verify input voltage with a voltme ter If there is input power the fuse may have blown The Aqua Rite is protected by a 20 amp slow blow fuse located on the bottom of the enclosure next to the wiring knockouts 2 Generating LED flashing The temperature of the pool water is too high or low to operate You can override this by switching the main switch to SUPER CHLORINATE The Aqua Rite will run at maximum output for the remainder of the current pump cycle or 24 hours whichever comes first 3 No Flow LED illuminated The Aqua Rite has sensed a no flow condition and has stopped generating chlorine Check that the flow switch is plugged into the connector on the bottom of the control unit and that the wire is not cut or damaged Make sure you have at least 12 of straight pipe before the flow switch If there is adequate flow and the LED is still on check that the arrows on the flow switch on top of hex are pointing in the direction of fl
2. and Aqua Trol products and IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL GOLDLINE CONTROLS INC BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDEN TAL DAMAGES OF ANY NATURE WHATSOEVER No wholesaler agent dealer contractor or other person is authorized to give any warranty on behalf of Goldline Controls Inc This warranty is void if the product has been altered in any way after leaving the factory 16 ELECTROLYTIC CHLORINE GENERATOR BASIC POOL MAINTENANCE REQUIREMENTS TEST IDEAL RANGE ADJUSTMENT REQUIRED Free Chlorine 1 0 3 0 ppm Turn output dial up to increase gt down to decrease OR increase ui or decrease pump filtration time pH 72 76 Too high add muriatic acid me Too low add soda ash p gt Alkalinity 80 120 ppm Add baking soda to increase E Add acid as required to decrease Salt 2700 3400 ppm Add salt as required to increase gt Stabilizer 60 80 ppm Add cyanuric acid to increase m z lt x Calcium 200 400 ppm Add calcium to increase gt Drain and add water to decrease Electrolytic Cell inspect amp clean Refer to section in manual Questions Refer to www goldlinecontrols com for latest manual revisions additional information and helpful service Or you may visit your local Authorized Aqua Rite Dealer or call 888 921 POOL 7665 for assista
3. day hours 2 the Desired Output setting 3 the amount of salt in the pool The filter pump timer should be set so that all of the water in the pool passes through the filter each day For pools with high chlorine demand the timer may have to be set longer to generate enough chlorine To find the optimum Desired Output setting start at approximately 50 Test the chlorine level every few days and adjust the dial up or down accordingly It usually takes 2 3 adjustments to find the ideal setting for your pool spa and after that it should only take minor infrequent adjustments Because the chlorine de mand of the pool increases with temperature most people find they have to adjust the dial up at the peak of the summer and down during the colder periods The Aqua Rite automatically stops generating when the pool water temperatures drops below 50 F This is usually not a problem because bacteria and algae stop growing at this temperature You can override this low temperature cutoff by switching to SUPER CHLORINATE for a day Prevent over chlorination during cold weather Check chlorine levels periodically Most pools require less chlorine during cold weather and the Desired Output dial should be turned down accordingly When using the optional Jandy AquaLink RS control The Jandy AquaLink RS is a multifunction pool controller and can fully control the function of the Aqua Rite chlorinator The AquaLink RS LED on the Aqua Ri
4. submerged It may be helpful to coil the wiring before immersing the cell The cell should soak for a few minutes and then rinse with a high pressure garden hose If any deposits are still visible repeat soaking and rinsing Replace cell and inspect again periodically Winterizing The Aqua Rite electrolytic cell and flow detection switch will be damaged by freez ing water just as your pool plumbing would In areas of the country which experi ence severe or extended periods of freezing temperatures be sure to drain all water from the pump filter and supply and return lines before any freezing conditions occur The electronic control is capable of withstanding any winter weather and should not be removed Spring Start up DO NOT turn the Aqua Rite on until the pool water chemistry has been brought to the proper levels This information can be found on page 1 INSTALLATION Installation must be performed in accordance with Local and NEC codes FILTER TIMER AQUA RITE 120 240 VAC une em POWER G e j eit HN FLOW ia 1i SWITCH FILTER ELECTROLYTIC CELL IN FLOOR CLEANER TO to SPA FROM FROM POOL POOL SPA Preparing Pool Spa Water Refer to page 1 for recommended chemical levels The pool s chemistry must be balanced BEFORE activating the Aqua Rite NOTE Ifthe pool does not have new water add 1 quart of metal remover and 1 quart of n
5. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 wdd og Gu 1 21 c 01 16 ze ZZ 89 r9 vs sr vs sr dd 9 vc 0 sl 9 ve 0 SL ZL GL cL OL 80 ZO me o7 ore 8 uz 9 Ez 2 09 8 1 i GD Kay c D 16 16 wdd 09 cS 8 vv ov Zt cS 8 vv ov Zt Ve oe Le vc 0 ZL el s er L9 ee 9 ve ze 6z Le GO cc 0 e 9 4 WL 91 v wdd os GIA OL Sig 09 SiG SA OL G9 09 Ss OS Sv Ov Ge 0 SiE 0 09 2 9 Lg gv c cv 6 9 e ve ore Gc io gi ro 81 dd OOL v6 28 08 OOL v6 Z8 08 vl Z9 09 vs Lv ov ee Le wdd Ov G2 12 49 79 09 419 z s 679 ev cv 8 oe Ge Ea Qe Ec temi 9 L SLL SOL OOL 6 9 L SLL 80L OOL 6 8 Sz L9 6S os cv ee 0 6 Gg c8 82 2 89 9 69 vs o s cv ce 9 8 ee uz ee uz wdd OGL 0 OEL OcL 0 09L 0 0 L 0 L OL OOL 06 os OL 09 09 ov oz 0 8 VoL 96 0 6 8 0 8 27 69 i79 6 s e s et cv Ze ze Ze ce wdd oL CLL VOL 9L 0 6 L CLL VOL 9L 0 6 SOL v6 Z8 OL 8S Lv 6 9 8 2 ov 86 6 9 8 62 2 19 1 9 9 6 e o e cv o wdd 0 00Z L8L 09L LV 00Z ZBL v 09L LV vel 0 L ZOL v6 08 L9 eG 0000gL 00SZtL 000SEL 00GZZL 0000ZL 00GZLL O00SOL 0076 00006 00SZ8 00087 00879
6. 00009 o0szs 000St oosze 00008 preise 000 0r 000 8E 000 9E 000 EZ 000ZE 0000 000 8Z 0009Z 0O00 vZ 000 ZZ 000 0Z 000 8L 000 9L O000 vL 000ZL oo0 0L 0008 Juano 19 em EdS IOOd Jo s193r1 pue suojeg INdd 08 O N QIOV DINNNVAD YIZNIAYLS 40 5y pue saNnod Controls Main Switch Note When the Aqua Rite is being controlled by the optional Jandy AquaLink RS the main switch will not funciton AUTO For normal operation the Main Switch should be left in the AUTO position In this position the Aqua Rite will produce chlorine according to the Desired Output adjustment setting for the entire filtering pumping cycle SUPER CHLORINATE When you have an abnormally high bather load a large amount of rain a cloudy water condition or any other condition which needs a large amount of purification to be introduced put the Main Switch in the SUPER CHLORINATE position This electronically super chlorinates shocks the water for 24 hours filter pump must be on during this time or until the power has been turned off whichever comes first At the end of the super chlo rinate time be sure to put the switch back into the AUTO position OFF The OFF position prevents the Aqua Rite from energizing the electrolytic cell In this position there is no chlorine generation NOTE To service any of the pool equipment or the Aqua Rite turn the power off at the circuit breaker Indicator LED s POWER Wh
7. PQUA FATE Electronic Chlorine Generator b G LDLING CONTROLS INC www goldlinecontrols com 888 921 POOL IMPORTANT SAFETY INSTRUCTIONS When using this electrical equipment basic safety precau tions should always be followed including the following READ AND FOLLOW ALL INSTRUCTIONS Disconnect all AC power during installation e Warning To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times A green colored terminal marked Earth Ground is located inside the wiring compartment To reduce the risk of electric shock this terminal must be con nected to the grounding means provided in the elec tric supply service panel with a continuous copper wire equivalent in size to the circuit conductors sup plying the equipment One bonding lug for US models two for Canadian models is provided on the external surface To reduce the risk of electric shock connect the local common bonding grid in the area of the swimming pool spa or hot tub to these terminals with an in sulated or bare copper conductor not smaller than 8 AWG US 6 AWG Canada All field installed metal components such as rails ladders drains or other similar hardware within 3 meters of the pool spa or hot tub shall be bonded to the equipment grounding bus with copper con ductors not smaller than 8 AWG US 6 AWG Canada SAVE THESE INSTRUCTIONS Table of Conten
8. Slave s Factory Default _ Additional Aqua Rite s if required Jand ios Jandy Aqua Rite Aqua Rite Controller Power Center Master Slave Notes 1 Never put more than 2 wires on a single terminal Use the optional Jandy multi plex PCB if necessary 2 There must be only 1 master unit All other Aqua Rite units must be config ured as slaves D Troubleshooting Visit www goldlinecontrols com for helpful information on operation maintenance and troubleshooting your Aqua Rite Electronic Chlorine Generator You may also call for technical assistance at 888 921 POOL Technicians at the factory are avail able from 8 00 AM to 8 00 PM Eastern Standard Time Monday through Friday Be sure to have the following information when you call 1 Model and Serial of control and cell 2 Date of installation 3 Installing Company or Dealer 4 Salt level Diagnostic Displays Sequential pushes of the small diagnostic button next to the LCD display will cause the Aqua Rite to display the following information 1 Pool temperature xx degrees Fahrenheit or Celsius 2 Cell voltage typically 22 0 to 25 0 volts when chlorine is being generated other wise 30 35V 3 Cell current typically 4 50 to 7 80 amps when chlorine is being generated other wise 0 amps 4 Desired Output OP 100P depending on knob position or input from Jandy AquaLink RS 5 Instant salinity Xxxx ppm or x xx grams Liter
9. d of chlorine Call Goldline 888 921 7665 for information regarding bromine generation Water Chemistry The table below summarizes the levels that are recommended by the National Spa and Pool Institute NSPI The only special requirements for the Aqua Rite are the salt level and stabilizer It 1s important to maintain these levels in order to prevent corrosion or scaling and to ensure maximum enjoyment of the pool Test your water periodically Your Authorized Aqua Rite Dealer AARD or most pool stores can provide you with the chemicals and procedures to adjust the water chemistry Be sure to tell the pool store that you are using an Aqua Rite chlorine generator CHEMICAL IDEAL LEVELS Salt 2700 to 3400 ppm Free Chlorine 1 0 to 3 0 ppm pH 7 2 to 7 6 Cyanuric Acid Stabilizer 60 to 80 ppm 80 ppm best Total Alkalinity 80 to 120 ppm Calcium Hardness 200 to 400 ppm Metals 0 ppm Saturation 2 to 2 0 best Index Saturation index The saturation index Si relates to the calcium and alkalinity in the water and is an indicator of the pool water balance Your water is properly balanced if the Si is 0 2 If the Si is below 0 2 the water is corrosive and plaster pool walls will be dissolved into the water If the Si is above 0 2 scaling and staining will occur Use the chart below to determine the saturation index Si pH Ti Ci Ai 12 1 Calcuim Total How
10. e salt in your pool spa is constantly recycled and the loss of salt throughout the swimming season should be small This loss is due primarily to the addition of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl salt that is greater than 99 pure This is common food quality or water softener salt and is usually available at build ing supply stores in 40 80 Ib bags labeled Coarse Solar Salt It is also acceptable to use water conditioning salt pellets however it will take longer for them to dis solve Do not use rock salt salt with yellow prussiate of soda salt with anti caking additives or iodized salt How to Add or Remove Salt For new plaster pools wait 10 14 days before adding salt to allow the plaster to cure Turn the circulating pump on and add salt directly into the pool Brush the salt around to speed up the dissolving process do not allow salt to pile up on the bottom of the pool Run the filter pump for 24 hours with the suction coming from the main drain use pool vac if there is no main drain to allow the salt to evenly disperse throughout the pool The salt display may take 24 hours to respond to the change in salt concentration The only way to lower the salt concentration is to partially drain the pool and refill with fresh water Always check stabilizer cyanuric acid when checking sal
11. en illuminated the Aqua Rite has input power GENERATING This LED is on steady during normal operation When flash ing the pool water is too hot or cold to operate SUPER CHLORINATE Illuminates during Super Chlorination See descrip tion above AQUALINK RS When illuminated indicates that the Jandy AquaLink RS is controlling the Aqua Rite the main switch and Desired Output adjustment are in active When flashing the AquaLink RS is in SERVICE or TIME OUT mode and the Main Switch and Desired Output adjustment are active NO FLOW When illuminated the flow switch has detected no water flowing and the Aqua Rite has stopped generating chlorine A flashing LED indicates a 15 60 second time delay period LOW SALT When flashing the salt level is low below 2700ppm and Aqua Rite is generating at low efficiency When illuminated steady the salt level is too low and Aqua Rite has shut down Before adding large quantities of salt it is advisable to have your salt level professionally checked HIGH SALT When flashing the salt level is high above 4000ppm but Aqua Rite will continue to operate When illuminated steady the salt level is too high and Aqua Rite has shut down INSPECT CELL A flashing indicator signifies that either the cell efficiency is reduced or that it is time for regularly scheduled cell inspection In either case inspect cell and clean if necessary When illuminated steady cell efficiency is greatly reduced and t
12. g Generating LED flashing Excessive scaling on cell High level of Nitrogen in pool water Yellow Out or similar treatment recently used Some yellow algae treatments will use chlorine at a very high rate and deplete the residual free chlorine Manu ally shock the pool if indicated in the directions on the algae treatment It still may be a matter of days before the pool returns to normal and chlorine tests will show the desired 1 3ppm free chlorine reading 14 Aqua Rite amp Aqua Trol Limited Warranty This warranty statement is applicable to all Aqua Rite and Aqua Trol units with product date codes of January 1 2002 and after and supersedes all warranty statements dated prior to January 1 2002 This Limited Warranty applies only to Aqua Rite and Aqua Trol Electronic Chlorine Generators Refer to the appropriate limited warranty statement for all other Goldline Controls products When installed on private single family residential swimming pools or spas within the USA and Canada Goldline Controls Inc Goldline warrants Aqua Rite and Aqua Trol to be free from defects in material or workmanship under normal use and service on private single family residen tial swimming pools within the USA and Canada for five years from date of the initial system installation provided it is installed in accordance with the installation instructions and specifications If written proof of the date of the initial system installation is n
13. he Aqua Rite has stopped producing chlorine Inspect clean or replace if necessary 6 Desired Output adjustment knob The Desired Output adjustment knob is located in the lower center of the Aqua Rite control panel This setting is used to control the amount of chlorine the Aqua Rite generates Raise this setting to increase chlorine level and lower it to decrease chlorine level Note The Desired Output adjustment will not function when the Aqua Rite is being controlled by the optional Jandy AquaLink RS Salt Display The Salt Display shows the current salt concentration of the pool water Readings are in ppm parts per million Refer to the Water Chemistry section for recom mended salt levels as well as how to add remove salt The factory default display is in English units ppm If Metric units grams per liter are preferred push the small button next the the display once The display will now show the pool temperature With the temperature displayed move the main switch from AUTO to SUPER CHLORINATE and back to AUTO The temperature display will instantly switch to Celsius and the salt display will switch to grams liter Repeat this process to switch back to English units ppm and Fahrenheit Operation Assuming that the water chemical levels are in the recommended range there are three factors that you can control which directly contribute to the amount of chlorine the Aqua Rite will generate 1 filter time each
14. lacement Servicing and Cleaning the Aqua Rite cell Turn off power to the Aqua Rite before removing the electrolytic cell Once re moved look inside the cell and inspect for scale formation light colored crusty or flaky deposits on the plates and for any debris which has passed through the filter and caught on the plates Ifno deposits are visible reinstall If deposits are seen use a high pressure garden hose and try to flush the scale off If this is not successful use a plastic or wood tool do not use metal as this will scratch the coating off the plates and scrape deposits off of plates Note that a buildup on the cell indicates that there is an unusually high calcium level in the pool old pool water is usually the cause If this is not corrected you may to have to periodically clean the cell The simplest way to avoid this is to bring the pool chemistry to the recommended levels as speci fied Mild Acid Washing Use only in severe cases where flushing and scraping will not remove the majority of deposits To acid wash turn off power to Aqua Rite Re move cell from piping In a clean plastic container mix a 4 1 solution of water to muriatic acid one gallon of water to one quart of muriatic acid ALWAYS ADD ACID TO WATER NEVER ADD WATER TO ACID Be sure to wear rubber gloves and appropriate eye protection The level of the solution in the container should just reach the top of the cell so that the wire harness compartment is NOT
15. nce GOLD L IN c East Greenwich RI 02818 USA CONTROLS INC 092009a
16. on copper based algaecide to the pool per manufacturers instructions This ensures a quick troublefree transfer to the Aqua Rite system Mounting the AquaRite Control The Aqua Rite is contained in a raintight enclosure that is suitable for outdoor mount ing The control must be mounted a minimum of 5 ft horizontal distance or more if local codes require from the pool spa The control is designed to mount vertically on a flat surface with the knockouts facing downward Because the enclosure also acts as a heat sink disperses heat from inside the box it is important not to block the four sides of the control Do not mount Aqua Rite inside a panel or tight enclosed area Plumbing Ensure that the Aqua Rite installation does not constitute a cross connection with the local potable water supply Consult local plumbing codes The flow switch and cell should be plumbed in the return line to the pool spa The preferred installation is after downstream all the pool equipment filter heater solar etc The electrolytic cell and flow switch tee fitting are designed to be plumbed into 2 PVC pipe Adapters not included can be used for systems with 12 plumb ing For proper plumbing refer to the overview diagram on page 9 Alternate configura tions 1 shows the flow switch can also be in front of the cell Configurations 2 and 3 allow for chlorination of both the pool and spa during spa spillover operation but prevent overchlorina
17. ot provided to Goldline the manufacturing datecode on the Aqua Rite and Aqua 77o electronics unit will be the sole determinant of the date of the initial system installation If a product is defective in workmanship or materials and is removed within 3 years 36 months after the date of the initial system installation and is returned freight prepaid Goldline Controls will at it s option either repair or replace the defective product and return it freight prepaid For years 4 and 5 Goldline will at it s option either repair or replace the defective product and will charge 60 of the current list price for such repairs or replacements plus shipping charges Goldline will not assume any of the cost incurred in removal or reinstalla tion of the product When installed on all other pools or spas The Limited Warranty for all other pools including but not limited to commercial pools public pools and pools located outside the USA and Canada is one year from date of the initial system installation provided it is installed in accordance with the installation instruc tions and specifications If written proof of the date of the initial system installation is not available the manufacturing datecode on the Aqua Rite and Aqua Trol electronics unit will be the sole determinant of the date of the initial system installation Ifa product is defective in workmanship or materials and is removed within 1 year 12 months after the date of the ini
18. ow 13 4 Low Salt LED illuminated or flashing Check salt level in pool spa If salt level is low add salt according to chart on page 4 Before adding large quantities of salt it is advisable to have your salt level professionally checked 5 High Salt LED illuminated Check salt level in pool spa If salt level is too high lower salt level by draining some of the pool water out of the pool and replace with fresh water Continue until the salt concentration is at recommended levels 6 Inspect Cell LED flashing Inspect and clean cell according to directions on page 8 When done press the diagnostic button for 3 seconds to stop the Inspect Cell LED flashing 7 Inspect Cell LED illuminated Remove and inspect the cell for scale If the cell is scaled follow the directions on page 8 for cell cleaning If the pool has the proper amount of salt and the Inspect Cell LED is still illuminated the cell may be worn and need replacement 8 Possible causes of little or no free chlorine residual Aqua Rite switch in OFF position Desired Output adjustment setting is too low Low stabilizer Cyanuric Acid Filter pump time too short 8 hours for average size pools more for large pools Salt level too low below 2500 ppm Low Salt LED on Salt level too high High Salt LED on Very warm pools increase chlorine demand increase Output or filter run time Cold water below 50F causes AquaRite to stop generatin
19. ration Wire the Aqua Rite to the LOAD SIDE ofthe filter pump timer Itis very important that the Aqua Rite is powered only when the pump is running Refer to the wiring label on the Aqua Rite as well as the diagram below to determine correct wiring connections The Aqua Rite is shipped from the factory with the configuration jumpers in 240V AC position If using 120VAC move the jumpers as shown below For Canadian models the Aqua Rite should be connected to a circuit protected by a class A ground fault interrupter Be sure to connect the ground wire to the green ground screw terminal located on the bottom of the enclosure TYPICAL 240 VAC WIRING 120 VAC TIMECLOCK SUBPANEL LINE Q S LOAD S S GROUND IMPORTANT MOVE JUMPERS TO POSITIONS SHOWN Q 7 BONDING LUG ERSTER BONDING LOOP Note Wire the pump directly to the timeclock do not use the Aqua Rite as a junction box Bonding A lug used for bonding is attached to the bottom of the Aqua Rite enclosure see diagram below The Aqua Rite must be bonded with an 8 AWG copper wire 6 AWG Canada to the pool bonding system Electrolytic Cell and Flow Switch The electolytic cell and flow switch cables are terminated with connectors which plug into the Aqua Rite for easy attachment and removal The door ofthe Aqua Rite must be open to access the cell cable connector The flow
20. switch plugs into a con nector similar to a telephone jack located outside on the bottom of the enclosure Refer to the diagram below for the location of these connections Cutout for cell cable a J uw G ws Bottom of FT e Aqua Rite Enclosure N Flow switch connector Bonding lug to 20 Amp Slow Blow Fuse pool bonding system 11 Input Power for use with Jandy AquaLink RS Wire the AquaRite DIRECTLY to 120 240VAC power not through timer or re lay JANDY AQUALINK RS 120 VAC AQUA RITE AQUA RITE 240 VAC 120 VAC SUBPANEL NEUTRAL GROUND BONDING BONDING UE VE Optional Jandy AquaLink RS The Jandy AquaLink RS and Aqua Rite use a 4 wire connection to communicate and can be wired up to 500 apart Any outdoor rated 4 conductor cable can be used Locate appropriate screw terminals on the circuit board according to the diagram below screw terminals are removable to aid in installation IMPORTANT Attach wires to like numbered screw terminal on both the Aqua Rite and AquaLink RS as shown in the diagram below Refer to Jandy s instructions for proper wire connec tion to the AquaLink RS D GREEN N Pa a 3 YELLOW 3 7 Ha N of E D2 BLACK Jumper Installed Jumper Removed 1 RED For Master j For
21. t These levels will most likely decline together Use the chart on page 5 to determine how much stabilizer must be added to raise the level to 80 ppm anid anid anid ana anid ania anid ana anid anid anid anid anid ang enira einig eia 009 MO MO oore esp IESDI ooze i S 000 09 zg EEL ZeL 008z une m cei Qu 192 ESZ 00vZ est rtt SS AS 00zz asi ZLL 00 ogg 000Z ra Loc 6s 19v err E 008L Eve Lec ZL eee 20S 00b 909r coc 6s2 009 OLS 00 roe 682 799 eeg ouch ese Qe ee 269 ogor voc ove 008 092 ee g6e gze 298 ze 003 ver cov ee6 288 oop esp oe coc 000 096 EA bie gp 09v o cp eso voc 6ee 9re 162 G2 cv eio ver 020 Sb ZD Go 0 Z90L LOL 096 406 Gg 008 Lvl 69 Or9 188 EEG 08v LCV ELE Oc 49c ELZ 000 0SL o0s zrL 000 SEL 00S 2zL 000 0ZL oos Z LL o00 s0 L 00g 26 00006 00g Z8 00082 00g Z9 00009 o0s zs 000St o0S z 0000 wdd 000 0 000 8E 000 9 000 E 000 ZE 0000 19 em BdS IOod Jo s19 T pue suoj es 000 8 000 9Z 000z 000 ZZ 0000Z 000 8L 000 9L OO0 vL OO0 ZL 000 0L 000 8 ISASI yes zua ung Wdd 00ZE O N Livs 40 5y pue saNnod
22. te chlorinator will be illuminated when Jandy AquaLink RS is in control Adjustment of the Aqua Rite output and also Superchlorination can be controlled from the main menu of the Jandy AquaLink RS Refer to the AquaLink RS instructions for more information The Aqua Rite salt display and LED indicators operate as nor mal but the main switch and Desired Ouput dial are disabled 7 Maintaining the Aqua Rite System To maintain maximum performance it is recommended that you open and visually inspect the cell every 3 months or after cleaning your filter The Aqua Rite will remind you to do this by flashing the Inspect Cell LED after approximately 500 hours of operation After you inspect the cell and clean if necessary press the small diagnostic button next to the display for 3 seconds to stop the flashing In spect Cell LED and start the timer for the next 500 hours The Aqua Rite electrolytic cell has a self cleaning feature incorporated into the elec tronic control s logic In most cases this self cleaning action will keep the cell work ing at optimum efficiency In areas where water is hard high mineral content and in pools where the water chemistry has been allowed to get out of balance the cell may require periodic cleaning The Inspect Cell LED will indicate if cell effi ciency is decreased and servicing is necessary If the Inspect Cell LED remains on after a thorough cleaning the cell may be worn and require rep
23. tial system installation and is returned freight prepaid Goldline will at it s option either repair or replace the defective product and return it freight prepaid Goldline will not assume any of the cost incurred in removal or reinstallation of the product Replacement parts If a purchased replacement part is defective in workmanship or materials and is removed within 1 year 12 months after the date of purchase and is returned freight prepaid Goldline will at it s option either repair or replace the defective purchased part and return it freight prepaid Warranty exclusions l Material supplied or workmanship performed by others in the process of installa tion 2 Damage resulting from improper installation 3 Problems resulting from failure to operate the products in accordance with recom mended instructions contained in product s owners manual 4 Problems resulting from failure to maintain pool water chemistry in accordance with recommended levels 15 Ri Problems resulting from installing less than one Aqua Rite unit per 40 000 gallons 25 000 gallons commercial public pools or one Aqua Trol unit per 18 000 gallons of pool water 6 Problems resulting from tampering accident abuse negligence unauthorized repairs or alterations fire flood lightning freezing external water war or acts of God The express warranty above constitutes the entire warranty of Goldline Controls Inc with respect to the Aqua Rite
24. tion of the spa during spa only operation Never use configu ration 4 ELECTROLYTIC 2 FLOW ELECTROLYTIC CELL CELL SWITCH P d Cl 7 12i L 1 VALVE VALVE an A E 1 121 min FLOW E POOL SPA SPA SWITCH POOL FLOW SWITCH E mm ELECTROLYTIC 7 ce ELECTROLYTIC CELL N 1 SPA smiren E i v POOL POOL Flow Switch IMPORTANT There must be at least a 12 30cm straight pipe run before upstream the flow switch If the switch is plumbed after the cell the cell can by counted as the 12 of straight pipe To ensure proper operation verify that the arrow on the flow switch located on top of gray hex points in the direction of wa ter flow Electrolytic Cell Install using the unions provided Tighten unions BY HAND for a watertight seal For pool spa combination systems with spillover use configurations 2 or 3 above to allow chlorina tion of both the pool and spa during spillover but preventing overchlorination when operating the spa only 10 Wiring Power must be shut off at the circuit breaker before performing any wiring Be sure to follow Local and NEC electrical codes To provide safe operation the Aqua Rite must be properly grounded and bonded Input Power For stand alone ope
25. to use Measure pool pH temperature calcium hardness and total alkalinity Use the chart above to determine Ti Ci and Ai from your measurements Insert values of pH Ti Ci and Ai into the above equation If Si equals 2 or more scaling and staining may occur If Si equals 2 or less corrosion or irritation may occur 2 0 2 CORROSIVE 4 amp 5 9 SCALING OK Salt Level Use the chart on page 4 to determine how much salt in pounds or Kgs need to be added to reach the recommended levels Use the equations below measurements are in feet gallons and meters liters if pool size is unknown Gallons Liters pool size in feet pool size in meters Rectangular Length x Width x Length x Width x Average Depth x 7 5 Average Depth x 1000 Round Diameter x Diameter x Diameter x Diameter x Average Depth x 5 9 Average Depth x 785 Length x Width x Length x Width x Oval Average Depth x 6 7 Average Depth x 893 The ideal salt level is between 2700 3400 ppm parts per million with 3200 ppm being optimal If the level is low determine the number of gallons in the pool and add salt according to the chart on page 4 A low salt level will reduce the efficiency of the Aqua Rite and result in low chlorine production A high salt level can cause the Aqua Rite to shutdown and may begin to give a salty taste to your pool gener ally the salt will begin to be tasted at a level of about 3500 4000 ppm Th
26. ts OPERATION Goernerrall MM Water Chemistry ien snenia nii Controls iea eden REUS Maintenance ee WARRANTY Warranty PR Aqua Rite is a registered trademark of Goldline Controls Inc AquaLink is a registered trademark of Waterpik Technologies Inc dun 15 OPERATION The Aqua Rite is an automatic chlorine generation system for pool or spa sanita tion The operation requires a low concentration of salt sodium chloride in the pool water These levels are low enough that it normally will not be tasted The Aqua Rite automatically sanitizes your pool by converting the salt into free chlorine which kills bacteria and algae in the pool Chlorine will revert back to sodium chloride after killing bacteria These reactions will continuously recycle virtually eliminating the need to add sanitizing chemicals to your pool The only time you may need to add more salt to the pool is when water is replenished due to backwashing draining or splashing not evaporation The Aqua Rite is designed to handle the purification needs of most residential swim ming pools up to 40 000 gallons 150 000 liters or the needs of most commercial pools up to 25 000 gallons 95 000 liters Check local codes for other restrictions The actual amount of chlorination required to properly sanitize a pool varies due to bather load rainfall temperature and the pool s cleanliness Bromine The system can also be used to produce bromine instea