Home
Vicks v9070 User's Manual
Contents
1. to the original purchaser of this product from the original date of purchase Atits option Kaz will repair or replace this product if it is found to be defective in material or workmanship Defective product should be returned to the place of purchase in accordance with store policy Thereafter while within the warranty period defective product may be returned to Kaz This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual Return defective product to Kaz Inc with a brief description of the problem Include proof of purchase and a 10 check or money order for handling return packing and shipping charges Please include your name address and daytime phone number You must prepay shipping charges Send to In US Kaz Inc Attn Returns Department 4755 Southpoint Drive Memphis TN 38118 USA Patent Pending Manufactured by KAZ Inc under license from The Procter amp Gamble Company Cincinnati Ohio USA VICKS is a registered trademark of the Procter amp Gamble Company 2004 Kaz Inc All Rights Reserved P N 035 04007 001 Rev 3 Artwork 043 01271 001
2. useful life of the filter NOTE The Main Filter is not washable CLEANING AND STORAGE We recommend that you clean the air purifier at least once a month and before extended storage Use only a dry cloth to wipe the external surfaces of the air purifier DO NOT USE WATER WAX POLISH OR ANY CHEMICAL SOLUTION If your Air Purifier will not be used for more than 30 days we recommend e Remove the Main Filter from the unit Wrap the Main Filter in an air tight plastic bag FREQUENTLY ASKED QUESTIONS My Air Purifier is starting to make noise and the air output is less What s wrong The filters may be dirty High amounts of contaminates can block the pores in the filter and stop the air from moving through it Replace the Filter How long should I run my Air Purifier For best results you should operate your Air Purifier 24 hours a day This unit will be more effective when doors and windows are closed Can I wash my Main filter No Washing the Main filter will destroy it lt P aly o A 035 04007 001_R3 V9070 OM Eng fm Page 4 Tuesday October 19 2004 12 21 PM CONSUMER RELATIONS NOTE IF YOU CONTINUE TO EXPERIENCE A PROBLEM PLEASE RETURN THE AIR PURIFIER TO THE PLACE OF ORIGINAL PURCHASE OR SEE YOUR WARRANTY DO NOT ATTEMPT TO OPEN THE AIR PURIFIER YOURSELF DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY IF YOU HAVE ANY QUESTIONS REGARDING THE A
3. A 035 04007 001_R3 V9070 OM Eng fm Page 1 Tuesday October 19 2004 12 21 PM A VICKS Q VvV i HEPA AIR PURIFIER Models V9070 and V9071 10 Do not expose the air purifier to rain or use near IM PORTANT water in a bathroom laundry area or other damp location SAF ETY 11 The air purifier must be used in its upright position or horizontal position only N ST RU CTI O N S 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or READ AND SAVE THESE m to the air purifier Do not block air outlets or intakes SAFETY INSTRUCTIONS 13 Locate air purifier near the outlet and avoid using an extension cord BEFORE USING THIS 14 This appliance has a polarized plug one blade is PRODUCT wider than the other To reduce the risk of shock this plug is intended to fit only one way in a When using electrical appliances basic precautions polarized outlet If the plug does not fit fully in the should always be followed to reduce the risk of fire outlet reverse the plug If it still does not fit contact electric shock and injury to persons including the a qualified electrician DO NOT attempt to defeat following this safety feature 15 A loose fit between the AC outlet receptacle and 1 Read all instructions before operating the air purifier plug may cause overheating and a distortion of the Place air purifier where it is not easily knocked over plug Contact a qu
4. IR PURIFIER PLEASE CALL OR WRITE Kaz Inc Consumer Relations Department 250 Turnpike Road Southborough MA 01772 Toll Free 1 800 827 6712 E mail consumerrelations kaz com ACCESSORIES REPLACEMENT FILTERS To order replacement Filter 16216 visit our website at www kaz com or call us at 1 800 827 6712 Washable Pre Filter 16266 5 25 Main Filter 16216 29 99 3 YEAR LIMITED WARRANTY You should first read all instructions before attempting to use this product A This 3 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship This warranty does not apply to damage resulting from commercial abusive unreasonable use or supplemental damage Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY o Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only
5. LL MAIN FILTER position see Fig 3 This will power the lonizer SEE S on To turn the lonizer feature off simply turn The Filter is supplied within the air purifier It is the knob to the OFF O position wrapped to ensure purity e Turn off and unplug the air purifier While NIGHTLIGHT FEATURE pressing on the two notches along the front grille pull the grille towards you and remove it The nightlight provides soft illumination See Fig 2 Gently push down on the top filter frame and pull forward To turn the night light on press the nightlight e Remove the protective wrap from the Filter button see Fig 3 e Place back into the air purifier housing and To turn it off press the nightlight button again snap filter grille into place S ad 035 04007 001_R3 V9070 OM Eng fm Page 3 Tuesday October 19 2004 12 21 PM ELECTRONIC FILTER CHANGE REMINDER This model air purifier has an electronic filter check to remind you when to check or replace the Main filter based on the air purifier s hours of use Once a filter has reached the end of its expected life its light will remain on until it is RESET You may unplug the air purifier without interrupting the filter check memory function A red LED light will illuminate when it is time to change the filter Please replace with Honeywell Main replacement filter number 16216 You should periodically check the filter Depending on operating conditions the Fil
6. OPERATION Stage 4 Electronic lonizer ee 4 Stage Cleaning System Fig 1 Ensure the air purifier is plugged into a working electrical outlet and the Power Knob and lonizer Knob are OFF Turn the Power Knob to the High position for several minutes and then rotate the Power AT Knob to the desired cleaning level Low 7 Meaner Air Il Medium III High 99 HEPA Filter CarboniFilter lonizer Field Washable Pre Filter Room Air It is recommended you run your air purifier 24 a hours a day to ensure continuous cleaning Portable air purifiers are more effective in rooms where all doors and windows are SET UP closed Select a firm level and flat location For proper IONIZER FEATURE airflow locate the unit at least 3 feet 1 M from any wall or furniture The lonizer helps boost the performance of the air e When operating large volumes of air are purifier and helps freshen the air drawn toward the air purifier Surrounding Fig 3 areas should be cleaned and or vacuumed frequently to prevent build up of dust and other contaminates This may also help prolong the life of the filter If the unit is placed on a light colored carpet a small mat or rug should be L used underneath to prevent permanent Power Speed staining This is especially important in homes AL O ia Control with contamination from smoking or fireplaces Knob Ss Turn the Ionizer Control Knob to the ON 1 INSTA
7. alified electrician to replace loose by persons in the household or worn outlet 3 Always turn the air purifier controls to the OFF 16 Do not sit stand or place heavy objects on the air position and unplug from the wall outlet when not in purifier use 17 Disconnect power supply before servicing 4 To disconnect the air purifier first turn controls to the 18 SAVE TH ESE INSTRUCTIONS OFF position grip the plug and pull it from the wall outlet Never pull by the cord 5 Do not use any product with a damaged cord or plug WARNING TO REDUCE THE RISK OF FIRE OR or if product malfunctions is dropped or damaged in ELECTRIC SHOCK DO NOT USE THIS AIR any manner Keep the cord away from heated PURIFIER WITH ANY SOLID STATE SPEED surfaces CONTROL DEVICE 6 Do not use air purifier outdoors 7 Never use air purifier unless it is fully assembled 8 Do not run power cord under carpets and do not cover with throw rugs Arrange cord such that it will not be tripped over 9 Do not use air purifier where combustible gases or vapors are present A gt 035 04007 001_R3 V9070 OM Eng fm Page 2 Tuesday October 19 2004 12 21 PM HOW YOUR AIR PURIFIER WORKS This model air purifier incorporates a 4 stage cleaning system to help clean the air that passes through the filter in the unit Fig 1 Stage 1 Washable Particle Pre Filter Stage 2 Carbon Filter Stage 3 99 HEPA Filter with ProTec antimicrobial treatment
8. ter should be replaced every 6 months To RESET the Electronic Filter Check Fig 4 Filter Monitor Reset When the filter monitor light remains on it is time to check replace the Main filter and reset the filter monitor if needed With the unit powered on insert the tip of a ball point pen or paperclip next to the LED filter check light and hold for approximately 5 seconds until the light turns off Fig 4 Depending upon your individual usage environment and hours used you may need to check and replace the filter more or less frequently If the Main filter is replaced before the filter monitor light turns on the filter monitor should be reset at the same time MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE FILTER The stage 1 particle pre filter helps pick up large airborne particles that enter the front grille This pre filter can be periodically removed and shaken to clean it Alternatively it can be rinsed by hand under warm water o o Let the pre filter air dry completely before inserting back into the unit If you need to replace this item please see Consumer Relations section on the next page WHEN TO REPLACE THE MAIN FILTER These replacement intervals are intended as guidelines only Useful life expectancy of any filter media is dependent upon the concentration of contaminates going through the system High concentrations of contaminates such as dust pet dander and pollen will reduce the
Download Pdf Manuals
Related Search
Related Contents
mode d`emploi de participation des commerçants Toshiba Qosmio X505-Q887 MODE D`EMPLOI LG Shine II User's Manual Lorex SC325000 User's Manual exacqVision Web Server Quick start Guide REF Series Undercounter Refrigerator Nantucket Pavers 31034 Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file