Home
Unisar BR101 User's Manual
Contents
1. amp 9 9 If the ambient temperature is outside the thermome Err ter s range see Technical Feri Specifications Err will appear in the display see Fig 10 10 The Ear Thermometer Bo al stores and recalls the last 10 temperature readings Figure 11 To recall prior readings 8 simply press the MEM button The memory symbol top left corner the number of the reading and the tempera ture reading will appear on the display See Fig 11 11 To get the most precise temperature reading wait five seconds before taking a temperature again 12 The temperature will vary between both ears so try to take the temperature from the same ear each time The Ear Thermometer is a Personal Care Product and cannot be returned to the retailer All exchange and refund requests should be directed to the B b Sounds Help Desk at 1 888 232 6476 Mon Fri from 9 00AM 5 00PM EST 9 UNDERSTANDING THE SYMBOLS Degrees of temperature 395 Celsius oc Fahrenheit oF Temperature is being scanned 4 l l Memory symbol and number of the recorded reading D 8 Low battery warning D Smiling face indicating temperature lower than D 100 4 F 38 C Frowning face indicating temperature higher than D 100 4 F 38 C CARE AND CLEANING 1 N w gt nn n I The ear thermometer is a delicate electronic device Although the probe is waterproof the body of the thermometer is not
2. BebeSounds Ear Thermometer INTRODUCTION Thank you for purchasing the B b Sounds Ear Thermometer This thermometer will enable you to take an accurate temperature in just one second The ear thermometer is a delicate electronic device designed to measure body tempera ture This thermometer provides you with accurate and reliable temperature readings by detecting infrared heat from the eardrum The eardrum reflects the body s temperature because it shares blood vessels with the part of the brain that controls body temperature Temperature readings from an ear thermometer are considered to be as accurate as those taken orally Please keep in mind that body temperature will differ based on a person s age and the time of day when it is taken Temperature will also vary from ear to ear Therefore for best results temperature should be taken from the same ear whenever possible Use of this ear thermometer should not replace a visit to your doctor It is recom mended that you advise your doctor any time a temperature is above 100 F 37 8 C 2 Water proof _ Probe po vA Y Fi f LCD display A Battery lid Memory button Power amp Scan button KEY FEATURES e No probe cover needed e Probe can be wiped clean with water or alcohol e Each temperature reading takes only 1 second e A second temperature reading can be taken after just 5 seconds e 512 temperature scanning sequences per sec
3. Therefore to ensure proper functioning avoid direct contact of the body of the thermometer with water or other liquids Clean the probe with a soft cloth moistened with either water or alcohol Clean the body of the thermometer with a soft dry cloth Never use an abrasive Avoid touching the probe with your fingers Do not expose the thermometer to direct sunlight Keep out of the reach of children and in the storage case when not in use The optimal storage temperature is between 4 122 F 20 50 C The ear thermometer is designed for taking temperatures from the ear canal only Do not use it to take rectal oral or armpit temperatures Do not disassemble the thermometer 11 NOTE According to extensive clinical examinations the temperature readings given by an ear thermometer are equivalent to those given by its oral counterparts Use of this ear thermometer should not replace a visit to your doctor TROUBLESHOOTING 1 Consistent low temperature readings a The probe is not positioned properly in the ear canal The tip of the probe must be snug and fully seated against the opening of the ear canal Failure to properly position the probe may lead to a low temperature reading b The waterproof lens is dirty Clean the lens with a soft cloth moistened with water or alcohol 2 The measurement is out of the range of the ear thermometer a Switch the ear thermometer on before positioni
4. ient temperature e EN 980 1997 Graphical symbol for use in the labeling of medical devices e EN 60601 1 Medical electrical equipment Part 1 General require ment for safety e EN60601 1 2 Medical electrical equipment Part 2 Collateral stan dard Electromagnetic compatibility Requirements and tests LIMITED PRODUCT WARRANTY The B b Sounds Ear Thermometer distributed by Unisar Inc has a limited warranty against defects for a period of three years from the original purchase date Battery life or damage due to misuse or abuse are excluded from this warranty In Warranty Procedure In the event service is required due to defect or malfunction during the warranty period Unisar Inc will replace or repair the product under warranty The repair or replacement of the defective item will be free of charge Repair or replacement of the defective item is subject to verification of the malfunction or defect when delivered to Unisar Service Center 15 West 36th Street New York NY 10018 USA Please enclose dated proof of purchase with your return The Ear Thermometer is a Personal Care Product and cannot be returned to the retailer All exchange and refund requests should be directed to the B b Sounds Help Desk at 1 888 232 6476 Mon Fri from 9 00AM 5 00PM EST Unisar Inc 15 West 36th Street New York NY 10018 1 800 233 1196 visit us at www bebesounds com
5. ng it in the ear Please properly position the ear thermometer in the ear canal and then repeat the measurement 3 Low battery warning a Battery needs to be replaced See Battery Installation section of the manual 12 NOTE If you believe your thermometer is defective or otherwise not operating properly please check the battery first If the thermometer is still not operating properly or if you are having any other technical problems please contact Unisar Inc 15 West 36th Street New York NY 10018 1 888 232 6476 TECHNICAL SPECIFICATIONS e For household use only e Temperature readings are to the nearest 0 1 F or C e Temperature measurement range 93 2 109 4 F 34 C 43 C e Ambient operating environment 60 8 104 F 16 40 C e Ambient storage environment 4 122 F 20 50 C e Laboratory accuracy against an infrared reference source 95 102 2 F 35 39 C 0 4 F 0 2 C less than 96 8 F 36 C 0 5 F 0 3 C greater than 102 2 F 39 C 0 5 F 0 3 C e Requires one 3 volt CR 2032 battery included e Equipment is not category AP APG 13 APPLIED STANDARDS AND APPROVALS FDA approved For home use only This product conforms to the provisions of the EC directive MDD 93 42 EEC The following standards apply to design and or manufacturing of the products e ASTM E 1965 98 Standard Specification for infrared thermometers for intermittent determination of pat
6. ond ensure reliable accuracy e Ergonomic design makes the thermometer comfortable and easy to use e Stores and recalls last 10 readings e Small and lightweight design makes it ideal for home use and traveling e Powers off automatically after one minute of non use to ensure a long battery life for at least 5 000 measurements e Easy to read LCD display e Temperature shown in Fahrenheit F or Celsius C The Ear Thermometer is a Personal Care Product and cannot be returned to the retailer All exchange and refund requests should be directed to the B b Sounds Help Desk at 1 888 232 6476 Mon Fri from 9 00AM 5 00PM EST 4 BATTERY INSTALLATION See diagram below 1 Replace the battery when the low battery warning symbol appears 2 Slide the battery compartment lid off 3 Insert one 3 volt CR 2032 lithium battery with the anode facing up 4 Replace the battery compartment lid by sliding it forward INSTRUCTIONS FOR USE 1 N w A Press and realease the POWER SCAN button and the system will start its self testing cycle See Fig 1 Once the self testing is completed the display will show the last temper ature recorded See Fig 2 This indicates that the thermometer is ready for you to use Press the POWER SCAN button without releasing it so it will perform the automatic scanning sequences The word Lo may appear indicating the temperatu
7. re registering is lower than 93 2 F 34 C See Fig 3 BE D PEE Figure 1 Figure 2 Figure 3 Keeping the POWER SCAN button depressed insert the probe into the ear canal The probe must be inserted well 6 into the ear to allow the probe tip to continuously scan the ear canal This will ensure an accurate temperature measurement See Fig 4 After one second release the POWER SCAN button for a temperature reading 5 A beep will indicate the end of the temperature measurement See Fig 5 Remove thermometer from ear canal and view the temperature 363 Figure 4 e 5 Figure 5 6 To change the reading from Celsius to Fahrenheit press the POWER SCAN button without releasing it and then press the MEM button 7 A smiling face will appear in the display to indicate a temperature lower than 100 4 F 38 C 2 55 Figure 6 while a frowning face al 38 57 accompanied by one long and two short beeps will indicate a temperature higher than 100 4 F 38 C See Figs 6 amp 7 Figure 7 eae The thermometer s 1 temperature range is between 93 2 109 4 F Figure 8 and 34 43 C A Lo reading appears when the temperature measured Figure 9 is lower than 93 2 F 34 C while a Hi reading appears when the temperature measured is higher than 109 4 F 43 C See Figs 8
Download Pdf Manuals
Related Search
Related Contents
COwZ User's Guide - Queen's University Belfast Descarga aquí la ficha técnica de este producto Télécharger le packaging du produit au format PDF SC-40NE 取扱説明書 Mise en page 1 Sin Nombre Virus RT-PCR Detection Kit 取扱説明書を必ずご参照ください。 1/2 ** 2013 年 8 月 20 日 (第 4 版 "取扱説明書" Copyright © All rights reserved.
Failed to retrieve file