Home

Uniden UH088SX CB User's Manual

image

Contents

1. MEM appears when the displayed channel is programmed either in GS or OS Memory 22 GROUP SCAN Indicator GS The GS icon appears when Group Scan Mode is activated Open scan is indicated by the absence of the GS icon UNIDEN UHE CB Transceiver Controls Indicators Connections CONNECTIONS FRONT PANEL 23 MICROPHONE SOCKET The microphone plug is inserted into this socket BAGK PANEL 24 25 26 EXTERNAL SPEAKER JACK used for remote receiver monitoring When the external speaker is connected the internal speaker is automatically disconnected The connecting wire must use a 3 5mm miniature plug only ANTENNA CONNECTOR Connect the Antenna here using a standard UHF PL259 type connector DC POWER CORD DC Power is connected to the transceiver through this jack A power cord is supplied with the transceiver UNIDEN UHE CB Transceiver Introduction The Uniden uh088sx is designed to provide you with years of trouble free service It s rugged components and materials are capable of withstanding harsh environments We are certain that you will enjoy your uh088sx Please read this operating Manual carefully to ensure you gain the optimum performance of the unit Features Transmit amp Receive FM 40CH UHF CB TX Power 5w 7 Segments LCD CTCSS function Tone Squelch Selcall Capability Duplex Capability from CHO1 CH08 per channel Open Scan Group Scan Variable Sguelch Level adjust Vo
2. oun 47668 S 31 477175 12 476100 32 477200 13 476725 gs 477225 1 476750 ga 477250 15 47618 gs 477275 16 476800 36 477300 17 47688 37 477325 18 47680 38 477350 19 47688 39 477375 20 476800 40 47740 Note Channel 05 and 35 are Emergency Channels and Channel 11 is a calling channel Tone Frequency Hz CTCSS TONE List Tone Frequency Hz 18 8 Tone Tone No Frequency Hz 103 5 107 2 167 9 Tor 60 No No KO Ug NOTE Channel 05 and 35 are not CT CSS programmable 01 06 825 08 18 UNIDEN UHE CB Transceiver ONE YEAR LIMITED WARRANTY IMPORTANT Evidence of the original purchase is reguired for warranty service WARRANTOR Uniden New Zealand Limited Uniden Australia Pty Ltd ACN 001 865 498 ELEMENTS OF WARRANTY Uniden warrants to the original retail owner for the duration of this warranty its uh088sx hereinafter referred to as the Product to be free from defects in materials and craftsmanship with only the limitations or exclusions set out below WARRANTY DURATION This warranty to the original retail owner only is only valid in the original country of purchase and shall be of no further effect 12 months after the date of original retail sale This warranty will be deemed invalid if the Product is 4 Damaged or not maintained as reasonable and necessary B Modified altered or use
3. UNTER RADIO uh088sx Owners Manual Microphone Mounting Bracket Knobs Microphone Hanger Screws Rubber washer Washer Stars and washers and Screws DC Power Cord with fuse UNIDEN UHE CB Transceiver Setting the Sguelch 1 To turn the unit ON rotate volume clockwise Adjust volume to a comfortable level Unigizen Sundowner UH 088 You must select a eas 00000000 channel which is 20000000 not in use before 24770004 888888 setting the SOUELCH 20022000 000000 control see p 10 2 Think of the Squelch control as a gate If you turn SQUELCH fully clockwise it raises the Sguelch Gate so that no signals get through Strong Signals vv Medium Signals Weak Signals 3 If you turn the SQUELCH fully counter clockwise it lowers the Squelch Gate so that everything gets through noise weak signals and strong signals Strong Signals gt gt Medium Signals gt d Weak Signals E Noise 4 To set the Squelch Gate to the desired level turn SQUELCH counterclockwise until you hear noise Then turn the SQUELCH Strong Signals _ mm Hip clockwise just until the noise stops Now only strong signals get through medium Signals gt Weak Signals gt Noise 1 UNIDEN UHE CB Transceiver SELECTING A CHANNEL Press U or a button to select a channel Unigi
4. EN UHE CB Transceiver Selective Calling Optional Selcall PCB Reguired Outline Selective Calling SELCALL is a special Seguential Tone Sguelch System that allows the user to receive transmit calls selectively from to an individual or group on a shared busy channel The uh088sx has an Optional Selective Calling system Exceptional features like Receiver Ouieting Tone Sguelch Scanning Tone and Group Calling make the uh088sx superior to any transceivers in its class Receiver Quieting Tone Sguelch When activated it automatically mutes the receiver audio circuit of the radio It will stay in this Quiet mode as long as the SELCALL tone code SELCALL ID required to open the muting circuit is not received Call Alarm When a received code matches to your SELCALL ID an alarm CA Alert will be emitted informing you that a caller is on the channel Tone Squelch Scanning Scans only tone squelched Channels Tone Calling Allows you to selectively call another radio Group Calling Capability Transmits and Responds to Group Calls 17 UNIDEN UHF CB Transceiver FM CB Frequency List Australia amp New Zealand Simplex Mode Aa Mode Simplex Mode Transmit Receive ransmit Transmit Receive CH No Frequency MHz Frequency MHz CH No Frequency MHz 06 476 550 477300CH36 26 477 050 08 476600 477350CH38 28 477 100 09 47668 29 477125 10 476680 DD go 477 180
5. ISPLAY LCD PANEL Indicators for TX CAL MEM TSQ GS OS SCN PRI Channel Number Frequency Signal Strength Level S Transmit Power Level RF CTCSS Code and DUP 2 UP DOWN CHANNEL SELECTOR These controls are used to select the desired communication channel 3 ON OFF VOLUME amp SQUELCH CONTROLS ON OFF amp Volume Control Centre Knob Turns the uh088sx power ON or OFF and adjusts the volume Squelch Control Outer Ring Eliminates background noise in the absence of an incoming spiral 4 PUSH TO TALK PTT SWITCH Press to transmit and release to receive 5 TONE CALL CONTROL BUTTON Press to transmit SELCALL codes it functions on condition that SELCALL option is installed 6 DUPLEX Control Press this button momentarily to choose semi duplex opeartion for channels 1 through 8 7 OPEN SCAN GROUP SCAN CONTROL OS GS Switches operation between OPEN SCAN and GROUP SCAN Mode 8 SCAN CONTROL SCAN Press to activate Normal OS GS scanning or press and hold to enable Seek Mode OS GS Scanning UNIDEN UHE CB Transceiver Controls Indicators Connections 9 MEMORY CONTROL MEM Places channel numbers into the memory scan list OS or GS 10 TONE SQUELCH CONTROL TSQ Controls Tone Squelched operation quiet Mode on condition that SELCALL option is installed 10 Secondary function Continuous Tone Coded Squelch System CTCSS is a feature that allows a group to talk to each other without hearing other
6. Uniden OWNER S MANUAL UNIDEN uh088sx CB RADIO UNIDEN UHE CB Transceiver Controls Indicators Connections COMO idas 3 A A 4 Comes non 5 Introduction Fealutes an as nel 6 Preventative Maintenance elek 6 Trouble oo a 6 Memory BACKUP anni anos 6 TA VOU aaa ae sah T Included with your uh088sx CB radio 8 Operation Setting thesSguel Mees 9 Selectins Channel euer 10 A Serene NAAN AGE 10 Using Repeater Chann sss sees 10 Operating the uh088sx in Duplex Mode n nee 11 SA AA AA 11 Open SCAN OS MONG une 11 Group Scan GS Mode 12 Choosing a Priority Channel 13 Drop OUT CLAY ans ee 13 Programming Scan Channels 14 Channel Seeking Operation 15 UNIDEN UHE CB Transceiver Continuous Tone Coded Squelch System CTCSS n eenn 16 Selective Calling Optional Selcall PCB Reguired QUITTING a ie NE Maui 17 Selective Calling SELCALL 101111 nman uamaumm 17 Receiver Quieting Tone Squclchi sss 17 A E A 17 Tone Squelch SCANNING ca 17 Tong GAMING ee 17 Group Calling Capability 0 enenee 17 Tables FIM GB Freuen LASS 2 EN 18 CT GSS TONE LAS sauna 18 WU AA 19 UNIDEN UHE CB Transceiver Controls Indicators Connections uh088sx CONTROLS Uniden Sundewner UH 088 20000000 HEI CAL MEM CS yumg N7 l NG 20000000 ae nt nn a ME 20000000 3858 LU EE 00000000 C3 iz 200000 E SY V uniden J 1 LIQUID CRYSTAL D
7. ation I Firstly activate scan mode by pressing 2 Press and hold until a beep is heard The SCN icon starts to flash 3 Ifan active channel is detected the uh088sx will stop on that channel for 4 seconds eg CH17 4 After 4 seconds the uh088sx will start seeking again for active channels 5 Ifyou find the channel interesting simply press either the PTT switch or GA to stop the operation before the 4 second timer elapses When GW is pressed again SEEK is still the mode of operation To change back to SCAN while SEEKING press and hold GA until a beep is heard The SCN icon stops flashing SEEK checks the same channel stored in SCAN memory Thus you can Seek either in OS or GS Mode 15 UNIDEN UHE CB Transceiver Operation Continuous Tone Coded Sguelch System CTCSS This feature allows signals to be received only from callers who have selected the same CTCSS code Press WW or fa to select the desired channel to use CTCSS Press and hold for 2 seconds CTCSS code flashes SCAN 05 65 DUPLEX Press Y or N to select the desired CTCSS code 01 38 Press CI once to store the new setting To turn CTCSS OFF please follow the above steps but select the desired CTCSS code oF before code 01 Channels 05 and 35 are Emergency Channels CTCSS cannot be selected on these channels If a button is not pressed within 10 seconds the uh088sx will automatically exit Select Mode 16 UNID
8. d as part of any conversion kits subassemblies or any configurations not sold by Uniden C Improperly installed D Repaired by someone other than an authorised Uniden Repair Agent for a defect or malfunction covered by this warranty E Used in conjunction with any equipment or parts or as a part of a system not manufactured by Uniden F Only available in the original country of sale PARTS COVERED This warranty covers for one 1 year the uh088sx transceiver only All accessories Mounting bracket Microphone etc are covered for 90 days only STATEMENT OF REMEDY In the event that the Product does not conform to this warranty at any time while this warranty is in effect the warrantor at its discretion will repair the defect or replace the Product and return it to you without charge for parts and service THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEOUENTIAL DAMAGES THIS GUARANTEE IS IN ADDITION TO AND DOES NOT IN ANY WAY AFFECT YOUR RIGHTS UNDER THE CONSUMER GUARANTEE ACT PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY in the event that the Product does not conform to this warranty the Product should be shipped or delivered freight prepaid with evidence of original purchase e g a copy of the sales docket to the warrantor at UNIDEN AUSTRALIA PTY LIMITED UNIDEN NEW ZEALAND LIMITED SERVICE DIVISION SERVICE DIVISION 345 Princes Highway 150 Harris Road Rockdale East Tama
9. en Sundowner UH 088 90000000 90000000 90000000 90000000 90000000 900000 TRANSMITTING za A p Select the desired channel Press the Microphone s PTT button hold it approx 7cm from your mouth and speak normally into the microphone The icon will light Release the PTT button to end A Caen the transmission and listen for a reply USING REPEATER CHANNELS UHF CB Repeaters are used to retransmit or relay your signal Repeaters will extend the range of your radio and overcome the shielding effect caused by solid obstructions In normal Simplex operation your radio transmits on one particular frequency and receives on that same frequency If there is a barrier that partially blocks your transmitted signal the probability of another radio receiving the signal is very slim Hills tall buildings metallic structures etc tend to act as a screen between radios Repeater Station y x U m IS D D D D IS D D D D oO Normal Simplex Operation Transmitting on CH 31 No Signal being Received lt DD DDDDDD DD DS OOOOO0000000 OOOOOOO00000 D DDDDDDDDD DD m 000 000 000 000 000 000 000 000 000 000 DDD OOO000000 000000000 oon0000000 OOOOOOO00 HnOOOOO000 OOOOO00000 OOOOO0000 oooooooo0o0 Standard Operation without Operation with the aid of the aid of a Repeater Station Repeater Station Duplex The Signal coming from your radio is received by the Repeater Stati
10. ki NSW 2216 Auckland AUSTRALIA NEW ZEALAND Fax 02 9599 3278 Fax 09 274 4253 www uniden com au www uniden co nz 19 Uniden 2004 Uniden Australia Pty Limited Uniden New Zealand Limited Printed in the in China UTZZ019247Z
11. lume Control with power ON Off Switch Preventative Maintenance The following system checks should be made every six to twelve months e Check the standing Wave Ratio SWR e Inspect the tightness of all electrical connections e Inspect the antenna coaxial cable for wear or breaks on the shielding e Inspect the tightness of all screws and all other mounting hardware Troubleshooting Should the unit malfunction or perform poorly follow these procedures e Check the power cord and fuse If there is trouble with receiving e Check the VOLUME control setting Be sure the SQUELCH is adjusted properly Possibly the radio is over squelched If there is trouble with transmitting e Check that the transmission line coaxial cable is securely connected to the ANTENNA connector e Check that the antenna is fully extended for proper operation e Check that all transmission line coaxial cable connections are secure and free of corrosion Memory Backup A built in EEPROM protects the channels stored in the uh088sx memory after the DC power cable is disconnected UNIDEN UHE CB Transceiver Introduction LAYOUT Front Panel Layout Linien Sundowner UH 088 20020000 iY CAL MEM GS NI 7 20000000 DUP 750 ngi SON te Dar Dei 90000000 585883 mie L 20000000 20000000 000200 Microphone Layout PIT Tone Call UNIDEN UHF CB Transceiver Included with your uh088sx CB radio 1 uniden J SSX EN whos
12. nal to return otherwise scanning resumes To skip the active channel press momentarily Scanning resumes To deactivate scan press GUN while scanning or the PTT button on the microphone If SCAN is deactivated while on an s ml active channel the uh088sx will stay V GI on that active channel If no channels are active the uh088sx will reinstate the starting channel 11 UNIDEN UHE CB Transceiver Group Scan GS Mode Allows you to monitor a priority channel while scanning To use GS Mode Scanning press the key GS icon appears on the display OS Mode is indicated by the absence of the GS icon GS Scanning checks the priority channel activity regularly If the Priority channel becomes active the radio will stay on that channel for as long as the signal is active sell 2 If the received signal ceases the unit will wait 3 seconds 415825 me for the signal to return otherwise scanning resumes If scanning stops on a channel which is not a Priority channel uh088sx will continue monitoring the priority channel for activity while listening to the active one eg CH40 becomes active If SCAN is deactivated while it is turned to an active channel the ub088sx will stay on that active channel If none of the channels are active the uh088sx will reinstate the starting channel If GS is initiated when there are no channels programmed in GS memory an error tone will be heard and scanning will not s
13. on and then retransmitted at the same time on another channel This operation is called Duplexing For example CHO1 on Duplex Mode will Receive on CH 01 but Transmit on CH31 CH02 on Duplex Mode will Receive on CH 02 but Transmit on CH32 etc If you transmit on CHO1 Duplex mode you are actually transmitting on CH31 the repeater station down converts your signal and retransmits on CH01 10 UNIDEN UHE CB Transceiver Operating the uh088sx in Duplex Mode For this example we are adopting CH01 as the channel being used in your area for repeater use 20 Press to switch Duplex On The duplex icon DUP appears 22 If Duplex is not required press again to switch Duplex off Only channels 01 08 are available for Duplex 20 2 H 088 Check with your local Retailer to determine if there is a Repeater in your area Scanning The uh088sx has a scanning feature that allows you to search for active channels automatically Furthermore the uh088sx is designed to have two types of scanning Open Scanning OS and Group Scanning GS to give you flexibility and allow you to use the radio more effectively Press and scanning starts The scan icon SCN appears Open Scan OS Mode Allows continuous scanning of channels stored in the Open Scan memory If an active channel is found scanning will stop on that channel This example shows CH40 active If the received signal ceases the unit will wait 3 seconds for the sig
14. tart see programming Scan Channels below 12 UNIDEN UHE CB Transceiver Operation Choosing a Priority Channel The starting channel when Group Scanning is initiated is always the priority channel Changing the PRI channel setting while scanning eg PRI Channel is CH17 476 825 Mhz a press fa to select a higher channel scanning pauses Of Drop out delay While scanning the uh088sx stops at a busy channel and receives a transmission When the received signal is over the unit will wait for three seconds for the return of the signal otherwise the radio resumes scanning 15 UNIDEN UHE CB Transceiver Programming Scan Channels I Select which Scanning Mode you wish to use on the channel Fats OS or GS Mode 20 GO DG 20 2 Select the channel you want to store r UH 088 700 2700 2700 200 702 70 3 Press and hold for 1 5sec to store MEM icon appears and a short tone gt beep is heard IN 200 TOO POO PO 4 To remove the channel form memory press and hold QED for 1 5 sec once more Two successive beeps are heard and the MEM icon disappears 14 UNIDEN UHE CB Transceiver Operation Channel Seeking Operation Unlike normal scanning CHANNEL SEEK is used more often when checking for active channels Ifa signal is detected while seeking the uh088sx will tune to that signal for 4 seconds only and the resumes Seeking Operation Changing from SCAN to SEEK Mode Oper
15. users on the same channel INDICATORS 11 Channel Indicator Indicates the channel number currently selected On TX SELCALL usage the Channel Indicator becomes a Memory location indicator 12 Scan Indicator SCN SCN icon appears when normal Scan mode is activated When Seek mode Scanning is selected the SCN icon blinks 13 Priority Indicator PRD Indicates that priority channel is active when continuously lit or flashes when it is regularly being checked for activity while GS scanning 14 Continuous Tone Coded Sguelch System CTCSS Code Indicates the CTCSS code selected for the current channel 15 Freguency Indicator Shows the freguency of the current selected channel 16 RECEIVE SIGNAL RF LEVEL indicator S RF Indicates the relative signal strength level when receiving S or the relative transmit power RF when transmitting 17 DUPLEX Indicator DUP The DUP icon appears when duplex operation is selected 18 TRANSMIT indicator TX TX appears when the PTT button on the microphone is pressed and the radio is transmitting The RF icon also appears at this time 19 TONE SQUELCH indicator TSQ The TSQ icon will appear when the selected channel is set to operate in Quiet Mode or flashes when the radio is called using SELCALL 20 CALL Indicator CAL The CAL icon appears when the uh088sx radio is called using SELCALL Italso appears when SELCALL codes are being transmitted 21 MEMORY Indicator MEM