Home

Tripp Lite SU3000RTXL3U User's Manual

image

Contents

1. Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional DNET1 Network Surge Suppressor Essential protection for data and communication lines Qty optional DCATV Network Surge Suppressor Essential protection for TV VCR coaxial lines Qty optional Tower Stands 2 9USTAND Tower Stand Expandable Tower Base Stand UPS Accessory Qty optional More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 3023 2009 Tripp Lite All Rights Reserved
2. AS400CABLE KIT SNMP Accessories ENVIROSENSE SNMPWEBCARD Surge Protectors DTEL2 3 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 2200 3000VA 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 2200 3000VA or less BP72V15 2U External Battery Pack for UPS System BP72V28RT 3U External Battery Pack for UPS System Tripp Lite Power Strip Multiple outlets wherever you need them Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Universal 2 Post Rackmount Kit Supports 2U to 4U UPS systems and battery packs Power Management Tools UPS Communication Cable Kit for System i AS400 iSeries Servers Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU For remote monitoring and control via SNMP Web or telnet Network Surge Suppressor Essential protection for data and communication lines Maintains continuous operation without using battery power during overvoltages to 138V Above this point output is supported from battery derived AC power Tested to UL1778 USA CSA C22 2 No 107 3 Canada NOM Mexico Class A emissions FCC Part 68 Industry 3 5 year warranties plus next day and on site warranty coverage available for select opportunities Contact Tripp Lite for Qty optional Qty optional Qty optional Qty optional
3. Unit Dimensions HWD cm Material of construction Form factors supported Cooling method Battery Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max Battery mode BTU hr Max COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility WatchDog compatibility Yes 112 44 55 53 11 25 x 23 x 31 5 28 5 x 58 4 x 79 3 73 85 33 49 5 25 x 17 75 x 26 13 3 x 45 x 66 Steel Rack 3U Built in cooling fan User replaceable hot swappable battery replacement supported via front access panel 0 to 95 non condensing 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 1219 3 BTU hr worst case 1328 4 BTU hr worst case Includes USB and DB9 serial ports Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Yes includes PowerAlert software CD ROM and complete cabling Yes includes slot for optional SNMPWEBCARD accessory SNMPWEBCARD Yes compatible with Tripp Lite s Watchdog system service to restore operation to locked equipment through soft reboot of application OS or hard power off on reboot of connected equipmenta ideal for unattended kiosk applications L
4. INE BATTERY TRANSFER Transfer time from line power to battery mode Low voltage transfer to battery power Zero online UPS continuously converts incoming AC to DC then back to AC When commercial power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Maintains continuous operation during undervoltages as low as 65V 80V at load levels over 70 Below this switchover point output is supported from battery derived AC power High voltage transfer to battery power SPECIAL FEATURES EPO port Cold Start Appearance Supports Emergency Power Off via set of dedicated built in EPO jacks Yes inverter can be cold started to enable temporary AC output during a power failure Attractive black steel rackmount housing BATTERY PACK ACCESSORY optional Battery Pack Accessory optional CERTIFICATIONS Certifications BP72V15 2U limit 1 BP72V28RT 3U multi pack compatible Canada telecommunications ROHS compliant WARRANTY Product Warranty Period Connected Equipment Coverage Optional Coverage 2 year product warranty 250 000 connected equipment insurance USA and Canada only additional information Related Items Extended Warranties WEXT3 2200 3000 WEXT5 2200 3000 External Battery Packs BP72V15 2U BP72V28RT 3U Power Distribution PS7224 PDU1215 Rackmount Wallmount Kits 2POSTRMkKITWM Shutdown Cable Kits
5. Tripp Lite 1111 West 35th Street l Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SU3Q00O0RTXL3U SmartOnline Expandable 3U Rack Tower UPS System On line double conversion sine wave UPS with PDU switching current monitoring and fault tolerant auto bypass Highlights e 3000VA 2400W on line double conversion extended run 3U rack tower UPS e Zero transfer time on line double conversion and economy mode operation supported e Maintains sine wave 110 120V 2 output during overvoltages to 138 and brownouts as low as 65V 50 60Hz auto sensing e Simultaneous use communications via HID compliant USB port serial port SNMP Web card slot and EPO interface e Fault tolerant auto bypass mode current monitoring and switched PDU control via 2 switchable output load banks e Input NEMA L5 30P 120V Output 4 NEMA5 15R 4 NEMA5 15 20R amp 1 NEMA L5 30R e 2 year product warranty 250 000 Ultimate Lifetime Insurance USA amp Canada only e Estimated Retail Pricing 1 400 00 Description 3000VA on line double conversion UPS system for critical server network and telecommunications equipment 3U rackmount form factor with an installed depth of 26 inches Expandable battery runtime with optional BP72V15 2U and BP72V28RT 3U external battery packs Full time sine wave 110 or 120V 2 output Uninterruptible Power Supply UPS actively converts raw incomin
6. Y 100 75 50 25 LED display panel easily rotates for better viewing in rackmount or tower configurations Alarms Multi function audible alarm with distinctive ring patterns offer notification of backup operation 2 seconds on 0 5 seconds off low battery warning 1 25 seconds on 0 5 seconds off overload sounds continuously UPS fault 4 2 seconds on 1 second off input voltage out of frequency 2 1 seconds on 0 14 seconds off and high input voltage 2 1 seconds on 0 07 seconds off Switches Includes power off on switch to enable system turn on press ON switch UPS battery test press ON switch during normal AC operation buzzer silence press ON switch during battery operation and OFF press OFF switch all switch functions require that the switch be pressed and held for longer than 2 seconds but less than 4 seconds SURGE NOISE SUPPRESSION AC surge 480 joules suppression AC suppression 480 joules response time Dataline suppression Set of 8 wire RJ style interface jacks offer surge suppression for network ethernet or TEL DSL connection Pins 1 2 3 and 6 offer ethernet protection starting at 7 5V and the center two wires pins 4 amp 5 offer TEL DSL line suppression starting at 260V EMI RFI AC noise suppression PHYSICAL Shipping weight Ibs Shipping weight kg Shipping Dimensions HWD in Shipping Dimensions HWD cm Unit weight Ibs Unit weight kg Unit Dimensions HWD in
7. g AC power to DC then re converts output back to completely regulated filtered AC output Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V Highly efficient operation in optional economy mode setting saving BTU heat output and energy costs NEMA L5 30P input plug NEMA 5 15 NEMA 5 15 20R and NEMA L5 30R output receptacles Network grade AC surge and noise suppression Zero transfer time between AC and battery operation Network management interfaces support simultaneous communications via USB port DB9 serial port and SNUPWEBCARD slot Includes USB and DB9 serial ports Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Supports simultaneous detailed monitoring of equipment load levels self test data and mains power conditions via all 3 network interfaces at once Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface Integrated two bank PDU switching supports load shedding and remote reboot of connected equipment 3 stage metered current monitoring and battery charge status LEDs Dataline surge suppression for dialup DSL or network ethernet connection Mains power and voltage regulation LEDs Audible Alarm Self test Fault tolerant auto bypass mode LED display panel easily r
8. on INPUT Maximum input amps Input connection type Input cord length Recommended Electrical Service BATTERY Full load runtime Half load runtime Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Replacement Battery Cartridge 4 NEMA 5 15R 4 NEMA 5 15 20R 1 NEMA L5 30R 2 controllable load banks support load shedding and remote reboot on demand of locked network devices each bank has 4 outlets Via 40A input breaker 24A NEMA L5 30P 10ft 3m 120V 30A dedicated circuit 5 minutes 2400 watts 14 minutes 1200 watts Supports extended runtime with optional external battery packs BP72V15 2U limit 1 and BP72V28RT 3U multi pack compatible 72VDC 3 6 years depending on usage less than 6 hours to 90 RBC96 3U qty 1 VOLTAGE REGULATION Voltage regulation description Overvoltage On line double conversion power conditioning maintains output within 2 of 110 120 volts at all times Maintains output of selected nominal 2 during overvoltages to 138V AC correction Brownout Maintains output of selected nominal 2 during undervoltages to 65V AC at loads greater than 70 undervoltage correction correction extends to 80V LEDS ALARMS amp SWITCHES Front panel LEDs LED STATUS DISPLAY line power green online green bypass yellow on battery green overload red battery low yellow 4 LED LOAD BATTERY LEVEL DISPLA
9. otates for better viewing in rackmount or tower configurations 4 post rackmount accessories 2 9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware accessories available Field replaceable hot swappable internal batteries and external battery packs Attractive all black UPS design Two year warranty with 250 000 connected equipment insurance Extended warranty and service contracts available Applications e Ideal for protection of critical 120V equipment in server rooms internetworking closets and telecommunications systems in rackmount or tower applications Common applications include corporate or departmental servers workstations hubs routers bridges CAD CAM workstations concentrators IP telephony and traditional PBX switching systems Package Includes e SU3000RTXL3U UPS System e PowerAlert Software and Cabling e Mounting hardware for 4 post rack enclosures e Instruction manual with warranty information Features e SmartOnline high performance UPS system is ideal for critical voice data medical and industrial network applications e True on line double conversion UPS provides perfectly regulated sine wave output within 2 of 110 120V user selectable under all usage conditions e Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time e Removes harmonic distortion fast electrical impulses frequency variations and other hard to solve power problems not addre
10. ssed by other UPS types e Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 110 120V 2 values e Standard internal battery set offers 14 minutes runtime at half load 1200W and 5 minutes at full load 2400W e Expandable battery runtime with optional BP72V15 2U and BP72V28RT 3U external battery packs e Compact rackmount form factor installs using only 3 rack spaces 3U with a maximum installed depth of 26 inches e Ships with all mounting accessories for 4 post rackmount installation e Optional 2POSTRMKITWM enables 2 post rackmount installation e Optional 2 9USTAND accessory enables small footprint upright tower placement e Fault tolerant auto bypass maintains continuous utility output to connected equipment even in cases where the UPS suffers internal failure and requires maintenance e Network interfaces support simultaneous communications via built in USB DB9 serial contact closure and SNUPWEBCARD slot e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP e UPS interface supports on battery low battery power restored AC voltage DC voltage output current monitoring battery charge current battery capacity AC line frequency timed inver
11. ter shutoff activate self test load bank output power control and remote reboot UPS nominal voltage adjustment and UPS line to battery power voltage setpoints e Built in Emergency Power Off EPO interface with cable e NEMA L5 30P input plug NEMA 5 15 20R amp L5 30R output receptacles e Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks each bank has four outlets e Front panel LEDs offer current monitoring and battery charge level information e UPS ships fully assembled in full compliance with DOT regulations no time consuming connection of internal batteries by user required e Single line TEL DSL or network ethernet line surge suppression e 2 year manufacturer s product warranty 250 000 Ultimate Lifetime Insurance Specifications SYSTEM OVERVIEW Voltage compatibility Frequency compatibility OUTPUT Output VA Output watts Output nominal voltage Output voltage regulation Output frequency regulation 120V AC 100 110 120V 50 60 Hz compatible auto sensing 3000 2400 120V AC 100 110 120V Maintains full time sine wave output within 2 of selected nominal less than 3 total harmonic distortion linear load 5 total harmonic distortion computer load Less than 5 THD on line and on battery Regulates line frequency to 50 60Hz 0 05Hz Outlet quantity type Customized load management receptacles Overload protecti