1. NEMA 5 15 20R and NEMA L5 20R output receptacles Network grade AC surge and noise suppression Zero transfer time between AC and battery operation Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Supports simultaneous detailed monitoring of equipment load levels self test data and utility power conditions via all 3 network interfaces Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface Integrated 2 bank PDU switching supports load shedding and remote reboot of connected equipment 3 stage metered current monitoring and battery charge status LEDs Dataline surge suppression for dialup DSL or network Ethernet connection Utility power and voltage regulation LEDs Audible alarm Self test Fault tolerant auto bypass mode Field replaceable hot swappable internal batteries and external battery packs Attractive all black color scheme 2 year warranty and 250 00Cconnected equipment insurance extended warranty and service contracts available Applications e Ideal for protection of critical servers internetworking equipment and other other sensitive electronic loads Common applications include corporate or departmental servers workstations hubs routers bridges CAD CAM workstations concentrators IP telephony
2. NOM Mexico Class A emissions FCC Part 68 Industry Canada telecommunications ROHS Compliant Product Warranty 2 year product warranty Period Connected 250 000 connected equipment insurance USA and Canada only Equipment Coverage Optional Coverage 3 5 year warranties plus next day and on site warranty coverage available for select opportunities Contact Tripp Lite for additional information Related Items Audio Cables CT120 Instant Read AC Outlet Circuit Tester Qty optional External Battery Packs BP48V24 2U BP48V242U External Battery Pack for UPS System Qty optional BP48V60RT 3U External Battery Pack and Cable 3U Expandable Blue 2 Point Connector Qty optional Shutdown Cable Kits AS400CABLE KIT Power Management Tools UPS Communication Cable Kit for System i AS400 iSeries Qty optional Servers SNMP Accessories ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or Qty optional switched PDU SNMPWEBCARD For remote monitoring and control via SNMP Web or telnet Qty optional Surge Protectors DTEL2 Network Surge Suppressor Essential protection for data and communication lines Qty optional DNET1 Network Surge Suppressor Essential protection for data and communication lines Qty optional DCATV Network Surge Suppressor Essential protection for TV VCR coaxial lines Qty optional More information including related products owner s
3. and traditional PBX switching systems Package Includes e SU2200XLNAFTA UPS System e PowerAlert Software and cabling e Instruction manual with warranty information Features e SmartOnline high performance UPS system is ideal for critical voice data medical and industrial network applications e True on line double conversion UPS provides perfectly regulated sine wave output within 2 of 110 120V user selectable under all usage conditions e Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time e Removes harmonic distortion fast electrical impulses frequency variations and other hard to solve power problems not addressed by other UPS types e Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 110 120V 2 values e Standard internal battery set offers 14 minutes runtime at half load 800W and 4 5 minutes at full load 1600W e Optional BP48V60 3UNAFTA external battery packs offer expandable battery runtime e Space saving upright tower format e Fault tolerant auto bypass maintains continuous utility output to connected equipment even in cases where the UPS suffers internal failure and requires maintenance e Network interfaces support simultaneous communications via built in USB DB9 serial and SNMUPWEBCARD slot e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e
4. complete cabling Yes includes slot for optional SNMPWEBCARD accessory SNMPWEBCARD Yes compatible with Tripp Lite s Watchdog system service to restore operation to locked equipment through soft reboot of application OS or hard power off on reboot of connected equipmentideal for unattended kiosk applications LINE BATTERY TRANSFER Transfer time from line power to battery mode Low voltage transfer to battery power High voltage transfer to battery power SPECIAL FEATURES EPO port Cold Start Appearance Zero online UPS continuously converts incoming AC to DC then back to AC When commercial power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Maintains continuous operation during undervoltages as low as 65V 80V at load levels over 70 Below this switchover point output is supported from battery derived AC power Maintains continuous operation without using battery power during overvoltages to 138V Above this point output is supported from battery derived AC power Supports Emergency Power Off via set of dedicated built in EPO jacks Yes inverter can be cold started to enable temporary AC output during a power failure Attractive black steel housing BATTERY PACK ACCESSORY optional Battery Pack Accessory optional CERTIFICATIONS Certifications WARRANTY BP48V60 3UNAFTA optional Tested to UL1778 USA CSA Canada
5. Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP e UPS interface supports on battery low battery power restored AC voltage DC voltage output current monitoring battery charge current battery capacity AC line frequency timed inverter shutoff activate self test load bank output power control and remote reboot UPS nominal voltage adjustment and UPS line to battery power voltage setpoints e Built in Emergency Power Off EPO interface with cable e NEMA 5 20P input plug user installable NEMA 5 15P replacement plug included NEMA 5 15 20R amp NEMA L5 20R output receptacles e Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks e Front panel LEDs offer current monitoring and battery charge level information e UPS ships fully assembled in full compliance with DOT regulations no time consuming connection of internal batteries by user required e Single line TEL DSL or network ethernet line surge suppression e 2 year manufacturer s product warranty 250 000 Ultimate Lifetime Insurance Specifications SYSTEM OVERVIEW Voltage 120V AC 110 120V compatibility Frequency 50 60 Hz compatible auto sensing compatibility OUTPUT Output VA 2200 Output watts 1600 Output nominal 120V AC 110 120V voltage Output voltage Maintains full time si
6. Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SU2200XLNAFTA SmartOnline Expandable Tower UPS System NAFTA assembled version of SU2200XLa Highlights e 2200VA 2 2kVA on line double conversion extended run tower UPS e Maintains sine wave 110 120V 2 output during overvoltages to 138 and brownouts as low as 65V 50 60Hz auto sensing e Simultaneous communications via HID compliant USB port serial port SNMP Web card slot and EPO interface e Fault tolerant auto bypass mode current monitoring and switched PDU control via 2 switchable output load banks e Input NEMA 5 20P 120V optional 5 15P included Output 6 NEMA 5 15 20R and 1 NEMA L5 20R 120V e 2 year product warranty 250 000 Ultimate Lifetime Insurance USA amp Canada only Description 2200VA on line double conversion UPS system for critical server network and telecommunications equipment Upright tower form factor Expandable battery runtime with optional BP48V60 3UNAFTA external battery packs Full time sine wave 110 or 120V 2 output Online double conversion Uninterruptible Power Supply UPS actively converts raw incoming AC power to DC then re converts output back to completely regulated filtered AC output Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V NEMA 5 20P input plug optional 5 15P inlcuded
7. ight Ibs Unit weight kg Set of 8 wire RJ style interface jacks offer surge suppression for network ethernet or TEL DSL connection Pins 1 2 3 and 6 offer ethernet protection starting at 7 5V and the center two wires pins 4 amp 5 offer TEL DSL line suppression starting at 260V Yes 58 6 26 6 15 25 X 13 X 24 38 7 X 33 X 61 53 4 24 2 Unit Dimensions HWD in Unit Dimensions HWD cm Material of construction Form factors supported Cooling method Battery Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max Battery mode BTU hr Max Audible Noise COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility WatchDog compatibility 10 25 X 9 X 19 5 26 X 22 9 X 49 5 Steel Tower Built in cooling fan User replaceable hot swap battery replacement supported via access panel 0 to 95 non condensing 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 792 BTU hr 741 BTU hr less than 45 dB 1m Includes USB and DB9 serial ports Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Yes includes PowerAlert software CD ROM and
8. manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 3543 2009 Tripp Lite All Rights Reserved
9. ne wave output within 2 of selected nominal less than 3 total harmonic distortion linear load regulation 5 total harmonic distortion computer load Less than 5 THD on line and on battery Output frequency Regulates line frequency to 50 60Hz 0 05Hz regulation Outlet quantity 6 NEMA 5 15 20R 1 NEMA L5 20R type Customized load 2 controllable load banks support load shedding and remote reboot on demand of locked network devices 3 outlets per management load bank receptacles Overload Via 30A input breaker protection INPUT Maximum input 16A 120V 17 6 110V amps Input connection NEMA 5 20P user installable NEMA 5 15P also included type Input cord length 10ft 3m Recommended Electrical Service BATTERY Full load runtime Half load runtime Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Replacement Battery Cartridge 120V 20A dedicated circuit 4 5 minutes with internal batteries 1600w 14 minutes with internal batteries 800w Supports extended runtime with optional external battery pack BP48V60 3UNAFTA multi pack compatible 48VDC 3 6 years depending on usage Less than 5 hours to 90 RBC48 SUTWR VOLTAGE REGULATION Voltage regulation description Overvoltage On line double conversion power conditioning maintains output within 2 of 110 120 volts at all times Maintains output of selected nominal 2 during overvol
10. tages to 138V AC correction Brownout Maintains output of selected nominal 2 during undervoltages to 65V AC at loads greater than 70 undervoltage correction correction extends to 80V LEDS ALARMS amp SWITCHES Front panel LEDs LED STATUS DISPLAY line power green online green bypass yellow on battery green overload red battery low yellow 4 LED LOAD BATTERY LEVEL DISPLAY 100 75 50 25 Alarms Multi function audible alarm with distinctive ring patterns offer notification of backup operation 2 seconds on 0 5 seconds off low battery warning 1 25 seconds on 0 5 seconds off overload sounds continuously UPS fault 4 2 seconds on 1 second off input voltage out of frequency 2 1 seconds on 0 14 seconds off and high input voltage 2 1 seconds on 0 07 seconds off Switches Includes power off on switch to enable system turn on press ON switch UPS battery test press ON switch during normal AC operation buzzer silence press ON switch during battery operation and OFF press OFF switch all switch functions require that the switch be pressed and held for longer than 2 seconds but less than 4 seconds SURGE NOISE SUPPRESSION AC surge 570 joules suppression AC suppression Instantaneous response time Dataline suppression EMI RFI AC noise suppression PHYSICAL Shipping weight Ibs Shipping weight kg Shipping Dimensions HWD in Shipping Dimensions HWD cm Unit we