Home

Tripp Lite SU10KRT3U User's Manual

image

Contents

1. computer rooms network closets and rugged industrial locations Package Includes e SU10000RT3UPM 3U UPS power module e BP240V10RT3U external battery pack e SU10KXFMRRT3U step down transformer with manual bypass switch e Four post compatible rack rail kit 3 sets e Tower stands for upright tower configuration e PowerAlert software complete data cabling and user manual Features e Tripp Lite SU10KRT3U 10kVA 10 000VA 9000 watt on line double conversion UPS system in 9U total rack tower configuration 3U UPS power module 3U external battery pack and 3U step down transformer e Included stepdown transformer with manual bypass switch enables hot swappable UPS power module replacement with no interruption in output power to connected networking equipment e Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions e Hardwire input and output connections e Maximum installed rack depth of only 32 5 in 82 6cm e Full time active power conditioning provides clean continuous dual conversion AC output free of voltage fluctuations power interruptions and line noise e Double conversion operation converts raw input from AC to DC then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types e Maintains full time sine wave output within 2 of 208 240 an
2. without notice Photos may differ slightly from final products Qty
3. R Transfer time Transfer time economy mode Low voltage transfer to battery power setpoint High voltage transfer to battery power setpoint SPECIAL FEATURES Cold Start startup in battery mode during a power failure Economy mode operation High availability UPS features Green amp high efficiency features CERTIFICATIONS UPS Certifications UPS Certification details WARRANTY Product Warranty Period Worldwide No transfer time 0 ms in online double conversion mode 8 ms typical power failure response in optional economy mode 100V 300V Cold start operation supported Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of 10 Double conversion mode is automatically restored as mains voltage varies beyond 10 with less than 1 millisecond transfer time between modes Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module Hot swappable batteries High efficiency economy mode operation Schedulable daily hours of economy mode operation Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category A EMI IEC 61000 4 5 1995 B Surge Immunity 2 year limited warranty Connected Equipment Insurance U S Canada amp Puerto Rico Related Items Optional Products Related Model SNMPWEBCARD ENVIROSENSE SRSWITCH BP240V10RT3U WEX
4. T3 SU10K WEXT5 SU10K 2POSTRMKITHD RELAYIOMINI RELAYIOCARD MODBUSCARD BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH 250 000 Ultimate Lifetime Insurance Description For remote monitoring and control via SNMP Web or Telnet Monitors temperature humidity and contact closure inputs Requires SNUPWEBCARD or switched PDU Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE External Battery Pack and Cable 3U Expandable Black 3 Point Connector 3 Year Extended Warranty For SU10K models 5 Year Extended Warranty For SU10K models Enables 2 Post Rackmount Installation of 3U and Larger UPS Transformer and Battery Pack Components 3 Relay I O Mini module Programmable Relay I O Card For remote monitoring and control via MODBUS protocol External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm variables txtModellD 247 1 Copyright 2013 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change
5. Tripp Lite i AA 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SUI0OKRT3U SmartOnline 10kVA On Line Double Conversion UPS 9U Rack Tower 208 120V or 240 120V Hardwire output Highlights e 10kVA 10 000VA 9000W on line double conversion UPS 0 9 power factor e 208 120V or 240 120V 50 60Hz output Economy mode option e 9U Rack Tower compatible Hot swappable power and battery modules e USB RS232 amp EPO ports support for SNMP WEB and contact closure card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e Hardwire input 3 wire Hardwire output Description Tripp Lite SU10KRT3U 10 000VA 10kVA 9000 watt online double conversion UPS system offers complete power protection for critical network applications This system delivers online double conversion UPS protection with zero transfer time suitable for advanced networking applications Fault tolerant auto bypass prevents unexpected service interruptions during UPS overload or internal fault conditions Included stepdown transformer with manual bypass switch enables hot swappable replacement of entire UPS power module with no interruption to connected equipment Enhanced availability fault tolerance and simple hot swap replacement options make this UPS ideal for advanced networking applications in data centers
6. conversion mode 106 to 125 for 1 minute 126 to 150 for 30 Details seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95 or less Nominal Output 120V 208V 240V Voltage s Supported Frequency 50 60 Hz auto selectable compatibility Frequency Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to compatibility details 50Hz or 50Hz to 60Hz Output frequency regulation 0 05Hz free running Output voltage 2 regulation line mode Output voltage 10 regulation Economy line mode Output voltage 2 regulation Battery mode Output AC waveform Pure Sine wave AC mode Output AC waveform Pure Sine wave battery mode INPUT Rated input current 54A 208V 46 8A 240V at maximum load Nominal Input 208V AC 240V AC Voltage s Supported UPS input Hardwire connection type UPS input 3 wire single phase input L1 L2 G connection description Recommended 60A Electrical Service BATTERY Full load runtime 4 3 min 9000w minutes Half load runtime 12 5 min 4500w minutes Expandable battery Supports extended runtime with optional external battery packs runtime External battery BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH pack compatibility DC system voltag
7. d 120V nominal at 50 60Hz during brownouts as low 100V and overvoltages as high as 300V e Expandable runtime is supported with optional BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH external battery packs e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs e Battery independent restart ensures automatic UPS power up without user interaction after lengthy power outages even when batteries are expired and require replacement e PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto shutdown of connected systems as UPS batteries become depleted e Includes Free PowerAlert monitoring software packages PowerAlert LOCAL for desktops and small business networks PowerAlert NSA Network Shutdown Agent for larger networks and PowerAlert NMS Network Management System for monitoring up to 250 SNMP enabled UPS PDU and other networking devices e Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 and USB interfaces e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Optional SNMVPWEBCARD offers communications and control via secure remote web and networ
8. e 240 VDC Battery recharge Less than 6 hours from 10 to 90 rate included batteries Battery replacement Hot swappable user replaceable external battery packs description VOLTAGE REGULATION Voltage regulation 2 output voltage regulation in standard online double conversion mode description Overvoltage Corrects overvoltages up to 300V correction Undervoltage Corrects undervoltages as low as 100V correction LEDS ALARMS amp SWITCHES LED Indicators 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD screen offers additional information and control options Front panel LCD display Alarms Alarm cancel operation Switches Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options LED LCD panel rotates for viewing in rack tower formats LCD Display supports ENGLISH FRENCH GERMAN ITALIAN SPANISH and PORTUGUESE see manual Unique audible alarms for all major UPS environmental and power conditions see manual Alarm cancel switch 2 Switches control off on power status and alarm cancel self test operation 2 additional switches support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time EMI RFI AC noise suppression PHYSICAL Installation form factors supported wit
9. h included accessories Included mounting accessory description Installation form factors supported with optional accessories Optional mounting accessory notes Primary form factor UPS Power Module dimensions in primary form factor height x width x depth inches UPS Power Module dimensions in primary form factor height x width x depth cm Installed whole system maximum rack depth inches Installed whole system maximum rack depth cm Installed whole system total rack space height rack spaces Secondary form factor UPS Power Module weight Ibs Instantaneous Yes 4 post 19 inch rackmount mounting rail kit included Tower 3 sets of adjustable 4 post rack rails included 2 9USTAND tower kit included 2 post rackmount 2POSTRMKITHD 3 sets of 2POSTRMKITHD required for 2 post rackmount installation Rackmount 5 14 x 17 5 x 25 82 13 1 x 44 4 x 65 6 32 5 82 6 9U Tower 43 UPS Power Module weight kg Stepdown transformer dimensions height x width x depth inches Stepdown transformer dimensions height x width x depth cm Stepdown transformer weight Ibs Stepdown transformer weight kg Included battery pack dimensions height x width x depth inches Included battery pack dimensions height x width x depth cm Included battery pack weight Ibs Included battery pack weight kg UPS Shipping dimensions height x w
10. idth x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg UPS housing material Cooling method ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load AC economy mode BTU hr full load 19 5 5 25 x 17 5 x 26 13 3 x 44 4 x 66 102 46 3 5 25 x 17 5 x 25 13 3 x 44 4 x 63 5 158 7 72 48 25 x 40 x 48 122 6 x 101 6 x 121 9 460 208 8 Steel Fan 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 3415 1275 AC economy mode efficiency rating 100 load Operating Elevation ft Audible Noise Operating Elevation m COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable 96 0 3000m 0 to 10 000 ft 60 dBA at front side 1 meter 0 3000 m USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards RELAYIOMINI installation requires removal of panel containing USB ports Included USB DB9 serial and EPO cables included WatchDog Supports Watchdog application OS and hard reboot restart options for remote applications compatibility LINE BATTERY TRANSFE
11. k interfaces e Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification e Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification requires removal of USB interface module e Supports Emergency Power Off EPO via built in interface e Included rail kit supports 9U 19 inch rackmount installation in 4 post racks e Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks e Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level nominal voltage selection frequency conversion and other operational parameters e LED LCD display panel rotates for viewing in rackmount or tower configurations e Network grade AC surge and noise suppression e Industrial mode option factory preset enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions e Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz no de rating e External battery packs are field replaceable and hot swappable Specifications OUTPUT Output Volt Amp 10000 Capacity VA Output kVA capacity 10 kVA Output Watt 9000 Capacity watts Output kW capacity 9 0 Output power factor 0 9 Output Capacity Supports up to 105 load continuously in double

Download Pdf Manuals

image

Related Search

Related Contents

User manual ALFANET 95  UIH-2D取扱説明書 Manual (PDF)  03 - Win Task Gen  FLAT PRO SPOTIX - Musik Produktiv  3 Measuring reference values for ongoing accuracy  011.7071 - TONDEUSE SEMI PRO  New World NWIHT601  Sistema de transmisión trasero  Documento di valutazione dei rischi  LG LFC20760 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file