Home

Tripp Lite SU10000RT3UG User's Manual

image

Contents

1. Puerto Rico amp Canada only 3 year 5 year next day and on site warranty coverage available for select opportunities contact Tripp Lite for more information BP240V10RT3U External Battery Pack for UPS System Qty optional External battery pack for use with select Tripp Lite UPS Systems Qty optional External battery pack for use with select Tripp Lite UPS Systems Qty optional External battery pack for use with select Tripp Lite UPS Systems Qty optional BP240V1037C 1PH Power Distribution PDUNV PDUMV20HV PDUMV20HVNET Rackmount Wallmount Kits 2POSTRMKITWM Shutdown Cable Kits AS400CABLE KIT SNMP Accessories ENVIROSENSE SNMPWEBCARD Start Up Warranty Services WEXT3 SU10K WEXT5 SU10K WEXT3 SU8000 WEXT5 SU8000 W02 BWO W02 BW2 1BD W02 BW2 247 W02 BW3 1BD W02 BW3 247 W02 EWO W02 EW2 1BD W02 EW2 247 W02 EW3 1BD W02 EW3 247 W02 BW1 1BD W02 BW 1 247 W02 EW1 1BD W02 EW1 247 External battery pack for use with select Tripp Lite UPS Systems Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Metered OU Vertical Rack PDU Metered Power Distribution Unit for Network Applications Switched Metered PDU with Remote Monitoring OU Vertical Rackmount Power Distribution Unit for Networks with Individually Switchable Outlets Current Metering Remote Monitoring and Control Two Post Rackmount Wallmount Kit buy 1 for
2. each power module and battery pack Power Management Tools UPS Communication Cable Kit for System i AS400 iSeries Servers Power Management Tools Environmental Sensor Power Management Tools Internal SNMP Web Card 3 Year Extended Warranty 1 year extension of standard 2 year warranty 5 Year Extended Warranty 3 year extension of standard 2 year warranty 3 Year Extended Warranty 1 year extension of standard 2 year warranty 5 Year Extended Warranty 3 year extension of standard 2 year warranty Regular business hours start up excludes on site warranty Regular business hours start up and two year on site next business day break fix warranty service for locations within 350 miles of a covered service area Regular business hours start up and two year on site 24 by 7 break fix warranty service for locations within 250 miles of a covered service area Regular business hours start up and three year on site next business day break fix warranty service for locations within 350 miles of service area Regular business hours start up and three year on site 24 by 7 break fix warranty service for locations within 250 miles of service area Evening or weekend hours start up excludes on site warranty Evening or weekend hours start up and two year on site next business day break fix warranty service for locations within 350 miles of service area Evening or weekend hours start up and two year on site 24 by 7 break fix warranty se
3. Tripp Lite H 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SU10000RT3UG SmartOnline Expandable Rack Tower UPS System Online double conversion protection for mission critical applications Highlights e Global 10 000VA 10kVA on line 6U rack tower UPS with expandable runtime 3U Power Module 3U Battery Pack e Zero transfer time on line double conversion and economy mode operation supported e Detachable PDU with manual bypass switch enables hot swap UPS replacement without powering off connected loads e 200 208 230 or 240V selectable input output voltage with hardwire input and six individually breakered C19 outlets e 2 output voltage regulation over an input voltage range of 156 to 296 e Simultaneous use RS232 and contact closure monitoring ports SNMP Web Card Slot and EPO interfaces e 250 000 Ultimate Lifetime Insurance USA Puerto Rico amp Canada only Description Global 10 000VA 10kVA on line double conversion UPS system for critical server network and telecommunications equipment Installs in only 6 rack spaces 3U power module and 3U battery pack maximum installed rack depth of 32 5 in Worldwide shipping version with 6 C19 outlets Maximum installed rack depth of 32 5 inches Expandable battery runtime with optional BP240V10RT3U external battery packs Full time sine wave 200 208 220 230 or 240V 2 output Act
4. boot of application OS or hard power off on reboot of connected equipmentAideal for unattended kiosk applications LINE BATTERY TRANSFER Transfer time from line power to battery mode Low voltage transfer to battery power High voltage transfer to battery power SPECIAL FEATURES EPO port Cold Start Appearance Zero online UPS continuously converts incoming AC to DC then back to AC When line power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Maintains continuous operation during undervoltages as low as 156VAC Below this point output is maintained utilizing battery reserves Maintains continuous operation during overvoltages to 276V AC Above this point output is maintained utilizing battery reserves Includes dedicated EPO emergency power off interface and cabling Inverter can be cold started to enable temporary AC output during a power failure Attractive all black color scheme BATTERY PACK ACCESSORY optional Battery Pack Accessory optional CERTIFICATIONS Certifications WARRANTY Product Warranty Period Connected Equipment Coverage Optional Coverage Related Items External Battery Packs BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1407C 1PH BP240V10RT3U Tested to UL1778 USA CSA Canada CE European Union NOM Mexico Class A Emissions ROHS Compliant 2 year product warranty 250 000 USA
5. e Tower Base Stand UPS Accessory buy 1 for each 9U worth of Qty optional rack equipment to be placed in a tower configuration More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 3899 2009 Tripp Lite All Rights Reserved
6. ight Ibs Unit weight kg Unit Dimensions HWD in Unit Dimensions HWD cm Material of construction Form factors supported Cooling method 106 7 x 85 1 x 58 4 Power Module 55 Ibs Battery Pack 136 5 Ibs Power Module 25 kg Battery Pack 62 kg Power Module 5 14 x 17 5 x 25 Battery Pack 5 16 x 17 5 x 25 Installed depth of power module extends to 32 5 inches with detachable PDU backplate installed Power Module 13 3 x 44 4 x 63 5 Battery Pack 13 4 x 40 6 x 63 5 Installed depth of power module extends to 82 6 cm with detachable PDU backplate installed Steel Rack 6U Fan Battery Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max Battery mode BTU hr Max COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility WatchDog compatibility User replaceable hot swappable external battery pack 0 to 95 non condensing 5 to 122 degrees Fahrenheit 32 to 104 degrees Fahrenheit 3022 btu hr 3022 btu hr Includes 2 built in DB9 monitoring ports 1 RS232 1 contact closure Includes PowerAlert UPS monitoring software for all common network and standalone operating systems Cabling included Built in accessory slot accommodates internal SNMP Web card and other network accessories Compatible with Tripp Lite s Watchdog system service to restore operation to locked equipment through soft re
7. installed depth of 32 5 in e Offers 4 min runtime at full load 10 000VA 8000W and 10 min at half load 5000VA 4000W Runtime is expandable with any number of optional BP240V10RT3U external battery packs e Full time sine wave 200 208 220 230 or 240V 2 output user selectable e Actively converts raw incoming AC power to DC then re converts output to completely regulated filtered AC output e Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V e Standard 3 wire 208V hardwire input connection e 6 individually breakered C19 outlets e Detailed LCD panel with scroll buttons provides detailed diagnostic test information on startup and during self tests plus real time data on input and output voltage frequency Hz load percentage battery charge level and more e Network grade AC surge and noise suppression e Zero transfer time between AC and battery operation e Network management interfaces support communications via RS 232 contact closure port and optional SNMPWEBCARD slot e Supports detailed monitoring of equipment load levels self test data and mains power conditions via network interfaces Includes PowerAlert monitoring software and complete cabling e Emergency Power Off EPO interface e Front panel LEDs provide at a glance confirmation of line power status battery power status AC to DC amp DC to AC conversion bypass mode and output power status e Fault tolerant auto bypa
8. ire DC cable 240VDC 4 6 years Less than 8 hours to 90 included battery set only VOLTAGE REGULATION Voltage regulation description Overvoltage correction Brownout correction On line double conversion process give this UPS the ability to maintain output voltage within 2 of selected nominal voltage at all times Maintains continuous operation without using battery power during overvoltages to 276V AC regulating output within 2 of selected nominal Maintains continuous operation without using battery power during brownout undervoltage conditions to 156V AC regulating output within 2 of selected nominal LEDS ALARMS amp SWITCHES Front panel LEDs 6 LED display line power bypass inverter charger output AC and battery operation LED LCD display panel easily rotates for better viewing in rackmount or tower configurations Alarms Multi function audible alarm offers notification of UPS start backup operation low battery overload UPS fault inverter fault DC bus fault overtemperature remote shutdown shutdown imminent and shutdown complete Switches Includes main power off on switch plus 2 switches to set and execute scrollable LCD functions SURGE NOISE SUPPRESSION AC suppression Instantaneous response time EMI RFI AC noise Yes suppression PHYSICAL Shipping weight Ibs 336 Shipping weight kg 152 5 Shipping Dimensions 42 x 33 5 x 23 HWDi in Shipping Dimensions HWD cm Unit we
9. ively converts raw incoming AC power to DC then re converts output back to completely regulated filtered AC output Operates continuously without consuming battery power during brownouts to 156V and overvoltages to 276V Highly efficient operation in optional economy mode setting saving BTU heat output and energy costs Standard 3 wire 208V hardwire input connection 6 individually breakered C19 output receptacles Detachable input output PDU module with manual bypass switch enables hot swap UPS replacement without disrupting power to connected equipment Network grade AC surge and noise suppression Zero transfer time between AC and battery operation Network management interfaces support communications via RS 232 contact closure port and optional SNMPWEBCARD slot Supports detailed monitoring of equipment load levels self test data and utility power conditions via network interfaces Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface Front panel LEDs provide at a glance confirmation of line power status battery power status AC to DC conversion DC to AC conversion bypass mode and output power status LED LCD display panel rotates for better viewing in rackmount or tower configurations Detailed LCD panel with scroll buttons provides detailed diagnostic test information at startup and during self tests plus real time data on input and output voltage frequency Hz load percentage and battery charge level A
10. rvice for locations within 250 miles of service area Evening or weekend hours start up and three year on site next business day break fix warranty service for locations within 350 miles of service area Evening or weekend hours start up and three year on site 24 by 7 break fix warranty service for locations within 250 miles of service area Regular business hours start up and one year on site next business day break fix warranty service for locations within 350 miles of a covered service area Regular business hours start up and one year on site 24 by 7 break fix warranty service for locations within 250 miles of a covered service area Evening or weekend hours start up and one year on site next business day break fix warranty service for locations within 350 miles of service area Evening or weekend hours start up and one year on site 24 by 7 break fix warranty service for locations within 250 miles of service area Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Tower Stands 2 9USTAND Tower Stand Expandabl
11. ss mode prevents loss of output during UPS fault conditions or excessive UPS loading e 4 post rackmount and upright tower installation accessories included 2POSTRMKITWM 2 post rackmount hardware accessories available e Field replaceable hot swappable power module and external battery packs e Attractive all black color scheme e 2 year warranty 250 000 connected equipment insurance e Extended warranty and service contracts available Specifications SYSTEM OVERVIEW Voltage compatibility Frequency compatibility OUTPUT Output VA Output watts Output nominal voltage Output voltage regulation Output frequency regulation Outlet quantity type 208V AC 200 208 220 230 240V 50 60 Hz 10000 8000 208V AC 200 208 220 230 240V Maintains pure sine wave output at all times regulated within 2 of selected nominal output voltage less than 3 total harmonic distortion when used with computer loads Regulates line frequency to 50 60Hz 0 05Hz 6 individually breakered C19 outlets INPUT Maximum input amps Input connection type BATTERY Full load runtime Half load runtime Expandable battery runtime Connects to UPS via DC system voltage Typical battery lifespan Battery recharge rate 200V 46 7A 208V 44 9A 220V 42 4A 230V 40 6A 240V 38 9A Hardwire 4 min 10 000VA 8000W 10 min S000VA 4000W Runtime is expandable with optional BP240V10RT3U external battery packs Included 3 w
12. udible alarm Self test Fault tolerant auto bypass mode 4 post rackmount accessories and 2 9USTAND tower kit included 2POSTRMKITWM 2 post rackmount hardware accessories available Field replaceable hot swappable power module and external battery packs Attractive all black color scheme 2 year warranty and 250 00 connected equipment insurance extended warranty and service contracts available Applications e Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection Common applications include any mix of servers workstations hubs routers concentrators IP telephony and traditional PBX switching systems e Global C19 outlet configuration allows a single UPS model to be specified for worldwide use Package Includes e 3U power module with detachable hot swap PDU input output panel and bypass switch e 3U external battery pack e Two sets of 4 post rackmount rails one for each of the 3U components e One set of tower stands for upright tower configuration e PowerAlert software complete data cabling user manual with warranty information Features e Global 10 000VA 10kVA on line double conversion UPS system high voltage input high voltage output e Detachable input output PDU module with manual bypass switch enables hot swap UPS replacement without powering off connected equipment e Installs in only 6 rack spaces 3U power module 3U battery pack with a maximum