1. Low voltage transfer to battery power setpoint High voltage transfer to battery power setpoint SPECIAL FEATURES Cold Start startup in battery mode during a power failure High availability UPS features Green amp high efficiency features CERTIFICATIONS UPS Certifications UPS Certification details WARRANTY Product Warranty Period International Product Warranty Period Mexico 17 5 Steel Fan 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 70 8 728 6 Audible Noise lt 50 dBA at Front Side 1 Meter USB HID enabled DB9 Serial Slot for SNMP Web interface Supports detailed monitoring of UPS and site power conditions Included USB and DB9 cabling included Supports Watchdog application OS and hard reboot restart options for remote applications 4 8 milliseconds 151 220V 158 230V 165 240V 266V 220V 278V 230V or 290V 240V Cold start operation supported Hot swappable batteries Greater than 95 efficiency GREEN UPS Tested to UL1778 USA Tested to CSA Canada CE Tested to GOST Russia Tested to SASO Saudi Arabia CE IEC 62040 2 year limited warranty 2 year limited warranty Product Warranty Period 2 year limited warranty Puerto Rico Related Items Optional Products Related Model Description Qty DCATV Network Surge Suppressor E
2. 50 500 0 7 220V 230V 240V 230V default voltage selection via back panel switches 50 60 Hz 9 5 5 6 C13 outlet s Includes 2 C13 to C14 output power cables Sine wave Pure Sine wave 3 6A 220V 3 5A 230V 3 4A 240V 220V AC 230V AC 240V AC C14 inlet IEC320 C14 input connection accepts a variety of detachable cordsets to match country or site specific wall receptacles 5 min 500w 15 min 250w 24 Less than 4 hours to 90 RBC24 SLT Battery access door Battery replacement description VOLTAGE REGULATION Voltage regulation description Overvoltage correction Undervoltage correction Severe undervoltage correction LEDS ALARMS amp SWITCHES LED Indicators Alarms Alarm cancel operation Switches Hot swappable user replaceable batteries Automatic voltage regulation AVR maintains line power operation with an input voltage range of 151 to 289V Voltage reduction of 13 applies when input is 232 265 220V 243 277 230V 254 289 240V Voltage boost of 15 applies when input is 178 198 220V 186 207 230V 194 216 240V Voltage boost of 32 applies when input is 151 173 220V 158 181 230V 165 189 240V 9 LEDs indicate line power battery power AVR overload and replace battery status with a 3 LED level meter for load and battery charge level Audible alarm indicates power failure and overload conditions Power fail alarm can be silenced u
3. nitoring options e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software Built in Emergency Power Off EPO interface with cable e Supports Tripp Lite s WatchDog software application requires optional WATCHDOGSW e 9 LEDs offer continuous status information of UPS operating parameters and site power quality e Hot swappable batteries allow on site battery replacement without powering off connected equipment e Single line Tel DSL and network Ethernet line surge suppression e UL USA cUL Canada CE IEC 62040 GOST SASO Specifications OUTPUT Output Volt Amp Capacity VA Output Watt Capacity watts Output power factor Nominal Output Voltage s Supported Nominal Voltage details Frequency compatibility Output voltage regulation line mode Output voltage regulation Battery mode Built in UPS output receptacles Included output power cables Output AC waveform AC mode Output AC waveform battery mode INPUT Rated input current at maximum load Nominal Input Voltage s Supported UPS input connection type UPS input connection description BATTERY Full load runtime minutes Half load runtime minutes DC system voltage VDC Battery recharge rate included batteries Replacement battery cartridge internal UPS battery replacement Battery Access 7
4. pn Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 lt E mail saleshelp tripplite com Model SMX750SLT SmartPro 75kVA Line Interactive Sine Wave UPS SNMPWEBCARD option Tower USB Serial 220 230 240V Highlights e 750VA line interactive tower UPS Sine wave output e 220 230 240V nominal output during brownouts and overvoltages e USB RS232 and optional SNMP Web card are available for simultaneous use e Front panel status LEDs with load level and battery capacity display e C14 input 6 C13 outlets Includes 2 C13 to C14 cables Description Tripp Lite s SMX750SLT intelligent line interactive sine wave UPS system protects servers networking accessories and telecommunications equipment from blackouts voltage fluctuations and transient surges Large internal batteries offer 15 minutes half load runtime and 5 minutes full load runtime 750VA 500 watt power handling capability and full time sine wave output offers guaranteed compatibility with networking telecom and other sensitive electronic applications Includes 6 protected C13 output receptacles total Network management interfaces support communications via USB RS 232 and optional SNMPWEBCARD network interface HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Network communications ports enable detailed monitoring of equipment load levels
5. self test data and utility power conditions Includes PowerAlert monitoring software and complete cabling Single line Tel DSL and network Ethernet line surge suppression Built in audible alarm and 9 LEDs offer status notification for line power battery power battery charge level load level plus AVR boost and trim operational status information Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges Attractive all black tower housing Package Includes e SMX750SLT UPS System e PowerAlert Software CD ROM e USB and serial cabling e User manual with warranty information Features e SMX750SLT line interactive UPS offers battery derived sine wave AC output during power outages voltage regulation during brownouts and overvoltages plus network grade AC surge suppression e 750VA 500 watt power handling capability with full time sine wave output offers guaranteed compatibility with networking telecom and other sensitive electronic devices e Large internal batteries offer runtimes of 15 minutes at half load 325VA 250 watts and 5 minutes at full load 750VA 500 watts e Automatic Voltage Regulation AVR circuits maintain user selectable 220 230 or 240V nominal output over an input voltage range of 158 to 277 e Includes 6 C13 output receptacles e IEC320 C14 input connection accepts a variety of detachable cordsets e Built in USB RS 232 and optional SNMPWEBCARD accessory mo
6. sing alarm cancel switch 2 Switches control off on power status and alarm cancel self test operation rear panel protected switches support nominal voltage selection SURGE NOISE SUPPRESSION UPS AC suppression joule rating UPS AC suppression response time UPS Dataline suppression EMI RFI AC noise suppression PHYSICAL Installation form factors supported with included accessories Primary form factor UPS Power Module dimensions in primary form factor height x width x depth inches UPS Power Module dimensions in primary form factor height x width x depth cm UPS Power Module weight Ibs UPS Power Module weight kg UPS Shipping dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs 480 Instantaneous 1 line TEL DSL 1 in 1 out 10 100Base T Ethernet Yes Tower Tower 10 25 x 6 75 x 13 25 26 x 17 1 x 33 7 34 1 15 5 14 x 9 75 x 18 5 35 6 x 24 8 x 47 38 6 Shipping weight kg UPS housing material Cooling method ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load Battery mode BTU hr full load Audible Noise COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable WatchDog compatibility LINE BATTERY TRANSFER Transfer time
7. ssential protection for TV VCR coaxial lines 1 DNET1 Network Surge Suppressor Essential protection for data and communication lines 1 DTEL2 Network Surge Suppressor Essential protection for data and communication lines 1 ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNUPWEBCARD 1 or switched PDU SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 U022 010 10 ft USB2 0 A B Gold Device Cable 1 A Male to B Male WATCHDOGSW WatchDog Service Monitoring Reboot Software 1 MODBUSCARD For remote monitoring and control via MODBUS protocol 1 More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm variables txtModellD 3021 Copyright 2013 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products