Home
Tripp Lite SMART2200RMXLN User's Manual
Contents
1. Single Phase Metered PDU 20A 120V OU Vertical Rackmount 28 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter Single Phase Monitored PDU 20A 120V 70 in OU Vertical Rackmount 24 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter Single Phase Monitored PDU 20A 120V 1U Horizontal Rackmount 8 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter Single Phase Switched PDU 20A 120V OU Vertical Rackmount 24 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter Single Phase Switched PDU 20A 120V 1U Horizontal Rackmount 16 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter Single Phase Auto Transfer Switch Switched PDU 20A 120V 1U Horizontal Rackmount 16 5 15 20R outlets 2 L5 20P 5 20P inputs Single Phase Hot Swap PDU 20A 120V 2U Horizontal Rackmount 4 NEMA 5 15R amp 4 NEMA 5 15 20R outlets 2 NEMA 5 20P input plugs More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm variables txtModellD 5427 Copyright 2013 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
2. 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 306 Communications USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface interface Network monitoring Pre installed SNMPWEBCARD network interface Supports detailed monitoring of UPS and site power conditions port description PowerAlert software Included Communications USB and DB9 cabling included cable WatchDog Supports Watchdog application OS and hard reboot restart options for remote applications compatibility LINE BATTERY TRANSFER Transfer time 5 milliseconds line to battery mode 1 millisecond battery to line mode Low voltage transfer 83 to battery power setpoint High voltage transfer 145 to battery power setpoint SPECIAL FEATURES Grounding lug Back panel grounding lug Cold Start startup in Cold start operation supported battery mode during a power failure High availability UPS Hot swappable batteries features Green amp high Greater than 95 efficiency GREEN UPS Individually controllable load banks efficiency features CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category A EMI WARRANTY Product Warranty 2 year warranty 3 year with registration Note registration is required for 3 year warranty Period Worldwide Connected 250
3. BP48V60RT 3U multi pack compatible compatibility DC system voltage 48 VDC Battery recharge rate Less than 4 5 hours from 10 to 90 included batteries Replacement battery RBC94 2U cartridge internal UPS battery replacement Battery Access Front panel battery access door Battery replacement Hot swappable user replaceable batteries description VOLTAGE REGULATION Voltage regulation Automatic voltage regulation AVR maintains line power operation with an input voltage range of 83 to 145 description Overvoltage Voltage reduction of 12 applies when input is between 127 and 145 correction Undervoltage Voltage boost of 12 applies when input voltage is between 96 and 108 correction Severe undervoltage Voltage boost of 24 applies when input voltage is between 83 and 95 correction LEDS ALARMS amp SWITCHES Front panel LCD Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data display plus configuration of voltage operating mode alarm function and a variety of additional options see manual for detailed LCD configuration and monitoring options Alarms Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions Alarm cancel Power fail alarm can be temporarily silenced using alarm cancel switch silent mode alarm configuration option operation available Switches 3 pushbutton switches control OFF ON pow
4. Line interactive UPS with Automatic Voltage Regulation AVR corrects brownouts and overvoltages from 83 to 145V e NEMA 5 20P input plug 4 NEMA 5 15 20R and 4 5 15R output receptacles Two independently switched output load banks e Maintains uninterrupted operation of connected networking equipment during blackouts surges brownouts and overvoltages e High 96 efficiency rating in line power mode offers reduced power consumption and BTU emisssions e Internal batteries offer 12 minutes at 50 load 960W and 4 5 minutes at 100 load 1920W e Extended runtime is available with optional BP48V24 2U limit 1 OR BP48V60RT3U no limit Output is reduced to 1600 watts maximum with external battery packs e External battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Hot swappable user replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment e Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5 bar battery charge graphic plus 7 selectable screens of detailed UPS and site power information e LCD interface also supports a number of advanced user setup and operating preferences e Ships with 4 post rackmount installation hardware Optional 2POSTRMKITWM enables 2 post rackmount wallmount installation Optional 2 9USTAND enables tower placement e Built in USB RS 232 and pre installed SNMPWEBCARD accesso
5. 000 Ultimate Lifetime Insurance Equipment Insurance U S Canada amp Puerto Rico Related Items Optional Products Related Model Description Qty WEXT5 2200 3000 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack 1 models 2200 3000VA or less BP48V24 2U External Battery Pack for UPS System 1 BP48V60RT 3U External Battery Pack and Cable 3U Expandable Blue 2 Point Connector 1 ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires UPS with 1 SNMPWEBCARD monitored PDU or switched PDU SRSWITCH Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE 1 2 9USTAND 2POSTRMKITWM WATCHDOGSW PDU1220 PDUV20 PDUMH20 PDUNV PDUMV20 PDUMNV20 PDUMNH20 PDUMV20NET PDUMH20NET PDUMH20ATNET PDUB20 Enables Tower Placement of Rackmount UPS Systems Enables 2 Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems WatchDog Service Monitoring Reboot Software Single Phase Basic PDU 20A 120V 1U Horizontal Rackmount 13 NEMA 5 15 20R outlets NEMA 5 20P input plug Single Phase Basic PDU 20A 120V OU Vertical Rackmount 14 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter Single Phase Metered PDU 20A 120V 1U Horizontal Rackmount 12 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter Single Phase Basic PDU 16A 100 240V 1U Rackmount C13 C19 outlets C20 input and C14 L6 20P L5 20P 5 20P and 5 15P adapters
6. er status MODE selection and MUTE ENTER control functions SURGE NOISE SUPPRESSION UPS AC suppression 570 joule rating UPS AC suppression Instantaneous response time EMI RFI AC noise Yes suppression PHYSICAL Installation form factors supported with included accessories Included mounting accessory description Installation form factors supported with optional accessories Primary form factor UPS Power Module dimensions in primary form factor height x width x depth inches UPS Power Module dimensions in primary form factor height x width x depth cm Installed whole system total rack space height rack spaces Secondary form factor UPS Power Module weight Ibs UPS Power Module weight kg UPS Shipping dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg UPS housing material Cooling method ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load COMMUNICATIONS 4 post 19 inch rackmount mounting rail kit included Adjustable mounting rail kit included 2 post rackmount 2POSTRMKITWM Wallmount 2POSTRMKITWM Tower 2 9USTAND Rackmount 3 43 x 17 32 x 19 46 8 7 x 44 x 49 4 2U Tower requires 2 9USTAND 57 6 26 2 7 9 x 21 7 x 24 2 20 1 x 55 1 x 61 5 68 8 31 2 Steel Fan
7. iled UPS and site power data plus enables a variety of UPS setup and configuration options Super fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot 96 line mode efficiency offers reduced heat emissions and operating costs Network management interfaces support communications via USB RS 232 and pre installed SNMUPWEBCARD network interface HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Network communications ports enable detailed monitoring of equipment load levels self test data and utility power conditions Includes PowerAlert monitoring software and complete cabling Switched output load banks enable scheduled and real time remote reboot and load shedding of select outlets Emergency Power Off EPO interface LCD display panel easily rotates for viewing in rackmount or tower configurations Audible alarm with push button momentary alarm cancel and silent mode configuration options Programmable self test Field replaceable hot swappable battery modules Package Includes e SMART2200RMXLN UPS system with Pre installed SNUPWEBCARD e PowerAlert software with USB Serial amp EPO cabling e 4 post installation kit e Owner s manual Features e Tripp Lite SMART2200RMXLN line interactive 2U rack tower UPS with 2200VA 2 2kVA 1920W capacity and extended runtime options e
8. ry e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software Built in Emergency Power Off EPO interface with cable Specifications OUTPUT Output Volt Amp 2200 Capacity VA Output kVA capacity 2 2 kVA Output Watt Capacity 1920 watts Output kW capacity 1 92 Output power factor 0 87 Output Capacity Output derates to 1600 watts in all external battery pack configurations Details Nominal Output 120V Voltage s Supported Frequency 60 Hz compatibility Output voltage 14 6 regulation line mode Output voltage 5 regulation Battery mode Built in UPS output 4 5 15R outlet s 4 5 15 20R outlet s receptacles Built in controllable Two switched single outlet load banks 1 5 15 20R amp 1 5 15R switched load banks Output AC waveform Pure Sine wave AC mode Output AC waveform Pure Sine wave battery mode INPUT Rated input current 16 0A at maximum load Nominal Input 120V AC Voltage s Supported UPS input 5 20P connection type UPS Input cord 10 length ft UPS Input cord 3 length m Recommended 20A 120V Electrical Service BATTERY Full load runtime 4 5 min 1920w minutes Half load runtime 12 min 960w minutes Expandable battery Extended runtime supported via optional external battery packs runtime External battery pack BP48V24 2U limit 1
9. ss Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 lt E mail saleshelp tripplite com Model SMART2200RMXLN SmartPro 2 2kVA 1 92kW Line Interactive Extended Run UPS Sine wave Pre installed SNMPWEBCARD 2U LCD USB Serial EPO 120V Highlights e 2 2kVA 2200VA 1920W line interactive 2U rack tower UPS 0 87 power factor e 120V nominal output during brownouts to 83V and overvoltages to 145V e Interactive LCD provides UPS status information and advanced configuration options e USB RS232 EPO and Pre installed SNMPWEBCARD interface e Expandable runtime Hot swap batteries 96 efficiency Sine wave output e 2 independently switchable output load banks e NEMA 5 20P input 4 NEMA 5 15 20R amp 4 5 15R outlets Description Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network grade power protection for critical server network and telecommunications equipment Line Interactive Uninterruptible Power Supply UPS with built in Auto Voltage Regulation AVR actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure Tripp Lite s unique configuration excels in exceptionally poor power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions Interactive LCD interface reports UPS operating mode deta