Home

Trion Supreme Series User's Manual

image

Contents

1. How to Maintain Your Air Cleaner The media filter cartridge in your air cleaner must be replaced periodically The frequency of filter replacement is best determined by visual examination On average filter cartridges should be replaced every 9 12 months with normal usage STEPS FOR REPLACING FILTER CARTRIDGE 1 Open access door by pulling the handle Remove door completely 2 Pull used filter straight out of cabinet and place to side 3 Remove new filter cartridge from plastic bag and save the bag 4 Slide new filter cartridge into cabinet with AIR FLOW arrow pointing in the direction of airflow 5 Replace door and place used filter in plastic bag for easy disposal Replacement Filter Cartridges For Your Media Air Cleaner Remember periodic inspection and replacement of your filter will ensure high efficiency air cleaning Contact your HVAC dealer for replacement filter cartridges Replacement Number of Filter Cartridge Filters Per Air Cleaner Model Filter Cartridge Size Part Number Carton Air Bear Supreme 1400 5 x 19 3 4 x 20 3 4 255649 103 20 x 20 Air Bear Supreme 1400 5 x 15 3 4 x 24 1 4 255649 105 16 x 25 Air Bear Supreme 2000 5 x 19 3 4 x 24 1 4 255649 102 20 x 25 Introduction Your media air cleaner is a high efficiency air filtration device designed to remove dirt dust pollen and other microscopic particles from the air passing through it How the Air Cleaner W
2. L OR CONSEQUENTIAL DAMAGES SO THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE Any warranty express implied or statutory representation or guarantee other than those set forth herein shall expire at the expiration date of this express limited warranty SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE LIMITATION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU Fedders Unitary Products reserves the right to make changes in the design and material of its products without incurring any obligation to incorporate such changes in units manufactured before the effective date of such a change CareCo 415 Wabash Ave PO Box 200 Effingham IL 62401 Phone 1 866 829 2440 email fiaqcustomerservice fedders com 10 by FEDDERS Air Bear Supreme Series Duct Mount Media Air Cleaner Installation Operation Maintenance CAUTION READ INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY FOR SAFE OPERATION 155595 010 7 04 LEII e mm eyaic aies Table of Contents Page NEKO CU CUO lt 4 secs csc a a N 1 UALEDIGOr aI osima aE 2 Capacity Selection Guide ccccssseeeeeeeeeeeees 2 Unit Dimensions seeria ie aea 3 istalla tioN anan il ance baci 4 Maintenance cities shcethus Wiens T 8 Warranty sarn a y r 10 Maintenance
3. MEDIA AIR CLEANER LIMITED TEN YEAR WARRANTY This limited warranty covers Fedders Unitary Products Residential Type Media Air Cleaners excluding door latch disposable media cartridge charcoal filter accessories ductwork and installation CareCo warrants that all new Trion Media Residential Air Cleaners are free from defects in material and workmanship under normal noncommercial use and service Trion will remedy any such defects if they appear within ten years from the date of original installation as evidenced by Proof of Purchase from an Authorized Trion Dealer subject to terms and conditions of this Limited Ten Year Warranty stated below 1 10 THIS LIMITED TEN YEAR WARRANTY IS GRANTED BY CARECO 415 WABASH AVE PO BOX 200 EFFINGHAM IL 62401 This warranty shall extend only to any noncommercial owner who has purchased the residential Media Air Cleaner other than for purposes of resale All components are covered by this limited warranty except expendable items such as charcoal filters and filter cartridges If within the warranty period any Trion residential Media Air Cleaner unit or component requires service it must be performed by a competent heating and or air conditioning contractor preferably the installing contractor CareCo will not pay shipping charges or labor charges to remove or replace such defective parts or components If the part or component is found by inspection to contain such defective material and work
4. manship it will be either repaired or exchanged free of charge at CareCo s option and returned freight collect In order to obtain the benefits of this limited ten year warranty the owner must notify the dealer or distributor in writing or by phone of any defect within 30 days of its discovery If after reasonable time you have not received an adequate response from the dealer or distributor notify in writing CareCo Warranty 415 Wabash Avenue Effingham IL 62401 or e mail to fiaqcustomerservice fedders com This limited warranty does not apply to any part or component that is damaged in transit or when handling has been subject to misuse neglect or accident has not been installed operated and serviced according to Fedders Unitary Product s instruction has been operated beyond the factory rated capacity or altered in any such way that its performance is affected There is no warranty due to neglect alteration or ordinary wear and tear Fedders Unitary Product s liability is limited to the replacement of defective parts or components and does not include the payment of labor charges to remove or replace such defective parts CARECO WILL NOT BE RESPONSIBLE FOR LOSS OF USE OF ANY PRODUCT LOSS OF TIME INCONVENIENCE OR ANY OTHER INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES WITH RESPECT TO PERSON OR PROPERTY WHETHER AS A RESULT OF BREACH OF WARRANTY NEGLECT OR OTHERWISE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTA
5. mum of 26 clearance in front of the access panel for filter cartridge replacement Transitions If the air duct does not fit the air cleaner cabinet opening gradual transitions are recommended to reduce air turbulence through the air cleaner and maximize efficiency Not more than 20 about 4 per running foot of expansion should be used on each side of the transition fitting Maximum 4 drop per linear foot lt gt Air Flow Air Flow Air Cleaner opening Furnace opening Furnace Air Cleaner Transition section
6. orks Dirty air enters the air cleaner by way of the return air duct system in your home Particles are collected by the special pleated filter media The pleats provide an exceptionally large filtering face area in a very compact space which allows maximum dirt holding capacities with minimum air flow resistance POLLEN amp SPORES DIRT amp DUST GREASE amp SOOT Unit Diagram Installation Air Bear Supreme 2000 20 x 25 x 5 Physical Installation Air Bear Supreme 1400 16 x 25 x 5 The air cleaner cannot be installed with the access door facing down The Air Bear Supreme 1400 20 x 20 x 5 section entitled Typical Mounting Positions pg 4 shows examples of proper 1 Cabinet 2 Filter Cartridge 3 Access Door air cleaner mounting with a variety of furnace installations Prior to Installing this Product 1 Read rules and instructions carefully for safe operation Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given on the product to make sure it is suitable for your application Remove the old furnace filter and discard 4 The air cleaner cannot remove existing dirt from the blower and ducts Clean the area thoroughly before beginning installation NOTE The following is a typical installation of the air cleaner on a highboy furnace You may have to alter the installation to fit your specific application 5 Loca
7. rn it around and replace in cabinet The directional arrows on the filter cartridge must point in the direction of air flow Humidifiers 1400 1400 2000 Location of the system humidifier is important to the operation of the air cleaner Filter Cartridge 16 x25 x5 20 x25 x5 When an evaporative type humidifier is used it may be installed between the furnace warm air duct and the return air duct without affecting the air cleaner Part Number Atomizing and spray type humidifiers should be installed downstream of the air Air Flow CFM 600 1400 600 1400 cleaner If the humidifier must be installed upstream allow at least 6 feet Dimensions sd between the air cleaner and humidifier A 7 1 8 181mm 7 1 8 181mm 7 1 8 181mm B 21 3 8 543mm 24 7 8 632mm 24 7 8 632mm C 20 1 4 514mm 16 1 4 413mm 20 1 4 514mm Duct Opening Jooo oS S o 19 483mm 22 1 2 572mm 22 1 2 572mm 17 7 8 454mm 13 7 8 352mm 17 7 8 454mm Filter Cartridge 9 12 months between changes Replacement UL class 2 Installation TYPICAL MOUNTING POSITIONS Air cleaner shown shaded in illustrations WARNING Before making changes to a HVAC system that may affect the ventilation of fuel burning appliances contact your heating contractor Transitions Basement Furnace Counterflow Lowboy Mounted Furnace horizontally in return Mounted horizontally in return duct just above the furnace plenum ju
8. st above the furnace Before Space Saver Furnace Highboy Side installation Mounted vertically where return air enters side inlet of furnace Horizontal Furnace Mounted vertically in return duct as close to the furnace as possible Offset Installation If there is less than 7 in for mounting the air cleaner between the duct and the furnace move the return air drop Installation Application This air cleaner is used in forced air heating cooling and ventilating systems The air cleaner should be installed in the system such that all the system air is circulated through the air cleaner Maximum performance is obtained with the system blower set for continuous operation Installation Requirements The best location for the air cleaner is in the return air duct next to the blower compartment In this location the blower motor and cooling coils will be kept clean Do not install the air cleaner in the discharge air duct Before installing the air cleaner consider the application If a transition between the ductwork and air cleaner is required refer to section entitled Transitions below The unit must be readily accessible for periodic inspection and replacement of the filter cartridge to maintain maximum efficiency and trouble free operation A clean coil will reduce utility costs by maintaining the coil s efficiency Failure to replace filter cartridge can cause damage to the cooling system Allow a mini
9. te the cabinet in the cold air return duct such that all of the return air flows through the unit If the furnace and air cleaner openings are different use a transition 6 Mounting holes are provided in the air cleaner cabinet for ductwork attachment The 140 diameter holes are sized for 8 sheet metal screws or 1 8 rivets If the adjoining ductwork is flanged install the screws with the screw heads inside the cabinet to prevent damage to the filter cartridge during removal and installation 7 Remove the plastic bag from the filter cartridge and replace filter cartridge in cabinet 8 After the unit has been secured seal seams air tight with duct tape or caulking Reinstall access door to ensure a tight seal Capacity Selection Guide Model Air flow CFM 600 800 1000 1200 1400 1600 1800 2000 Air Bear Supreme Air Bear Supreme Air Bear Supreme 1400 20 x 20 1400 16 x 25 2000 20 x 25 Resistance Inches W G Blower Compartment Mounting Holes Installation Turning Vanes If the air cleaner is installed adjacent to a 90 duct elbow add turning vanes inside the duct to improve the air distribution across the face of the air cleaner Turning Vanes Direction of Air Flow Through the Air Cleaner The air cleaner is set up for left to right air flow when facing the access door For right to left air flow remove filter cartridge tu