Home

Triarch 29321-17 User's Manual

image

Contents

1. es TI ASSEMBLY INSTRUCTION ITEM 29321 17 1 Tighten outlet box screw longer 2 full turns into mounting strip Secure with hex nut to be fully tightened later Secure with 5 32 hex nut The outlet box scew should extend long enough to protrude the canopy when it is mounted 2 Fasten mounting strip onto outlet box using outlet box screw shorter 3 Thread tube of fixture body to upper bushing of socket assembly 4 Connect the wires from the fixture to the power supply wires from outlet box Cover with wire connectors a Twist together white wire from the fixture with white wire from outlet box Cover with connectors b Twist together black wire form the fixture with black wire form outlet box Cover with connectors c Wrap the ground wires from the fixture and outlet box around the green ground screw located on the mounting strip Tighten the green ground screw to the mounting strip 5 Place canopy over outlet box Let heads of outlet box screw longer come through the holes of the canopy then secure by tightening with cap nut Thread nipple into bushing Secure with hex nut Install the bulbs not included Do not use greater than 60 watt the bulbs 8 Slide glass shade washer and secure with hex nut Do not too tighten Then set decorative cap and secure by tightening with finial NO NOTE Carefully remove the fixture from the carton Check that all parts shown in package parts 1 and parts 2 are included Be carefully not to
2. be in accordance with local codes ordjnances or the National Electrical Code If you are unfamiliar with methods of installing electrical wiring secure the services of a qualified licensed electrician These fixtures are intended to be mounted to a 4 x 2 4 deep metal octagon outlet box The box must be directly supported by the building structure Before starting the installation disconnect the power by turn ing off the circuit breaker or by removing the fuse at the fuse box Turning the power off using the light switch is not suffi cient to prevent electrical shock NOTE The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and sit uations that may occur It must be understood that common sense caution and care are factors which cannot be built into any product These factors must be supplied by the person s caring for and operating the fixture UNPACK THE FIXTURE Check the contents of the box You should receive Mounting hardware package e Lampholder assembly s e Mounting bracket e Shade s not provided on all models e Shade attachment screws 3 for each shade not provided on all models PREPARE THE FIXTURE NOTE FIRST TURN OFF ELECTRICITY ADJUST THE CROSS BAR If you are replacing an existing fixture disconnect and remove the old fixture Expose the supply wiring from the outlet box 2 Some fixtures are provided with a threaded nipple s
3. circuit Attach all grounding conductors to the mounting bracket with the green grounding attachment screw Make electrical connections SEE BELOW ELECTRICAL CONNECTIONS To make electrical connections Connect the white wire s from the fixture to the white wire of the supply circuit Connect the black wire s from the fixture to the black wire of the supply circuit Connect the green or bare copper colored wire to the grounding conductor of the supply circuit If your fixture is supplied with an SPT Cord connect the half of the SPT Cord that is ribbed surface to the white wire of the supply circuit Connect the smooth half of the wire the half with markings to the black wire of the supply circuit Use U L Listed wire connectors suitable for the size type and number of conductors No loose strands or loose wires should be present Secure wire connectors with U L listed electrical tape FINAL ASSEMBLY Spread the electrical splices so that the black wires are on one side of the outlet box and the white wires are on the other side Place fixture against mounting surface allowing the threaded nipple or machine screws to pass through the coverplate Se cure with mounting nut or acorn nuts For fixtures with chan nel shape mounting bracket place the coverplate over the channel and secure with screws provided If applicable place candle cover s over lampholder s be fore installing bulb s Install the lightbulb s n
4. misplace any of the screws or wire connectors which are needed for installing the fixture Package parts Description No of pieces Description No of pieces Wire connector 2 Cap nut 2 Green ground screw 1 Nut 2 Outlet box screw 2 Nipple 1 Mounting strip 1 Washer 1 Support screw 2 Decorative cap 1 5 32 Nut 2 Finial 1 1 OUTLET BOX WHITE WIRE WIRE CONNECTOR GREEN GROUND SCREW WIRE CONNECTOR TLET BOX SCREW MOUNTING STRIP SER Be AIRE ___ SUPPORT SCREW BLACK WIRE TUBE FIXTURE BODY UPPER BUSHING SOCKET ASSEMBLY m SOCKET BUSHING 4 NUT i gt NIPPLE GLASS WASHER NUT DECORATIVE CAP SN Y FINIAL LA YA s d A A A yA A A A READ 8 SAVE THESE INSTRUCTIONS BRS eee TFT TI INSTALLATION OPERATION INSTRUCTIONS TOOLS amp MATERIALS REQUIRED Blade screw driver Adjustable wrench e Step Ladder e Wire cutters e Wiring supplies as required by electrical code CAUTION Before assembling your Lighting fixture refer to the section titled ELECTRICAL CONNECTIONS If you feel you do not have electrical wiring experience refer to a do it yourself wiring handbook or have your fixture installed by a qualified licensed electrician GENERAL To ensure the success of the installation be sure to read these instructions and review the diagrams thoroughly before begin ning All electrical connections must
5. ee Fig 1 or machine screws see Fig 2 and 2A for attaching the fixture to the mounting bracket If your fixture is supplied with a threaded nipple screw the nipple 3 complete turns into the mounting bracket and lock into place with a hexagon lock nut If your fixture is supplied with machine screws thread the ma chine screws into the opposite side of the mounting bracket from the green ground screw Lock the machine screws into place with lock nuts EXCEPTION Ceiling mounted fixtures with keyhole slots should have machine screws entering mounting bracket from same side as green grounding screw see Fig 2A Fasten the mounting bracket to the outlet box using the two screws supplied with the outlet box If your fixture is supplied with a channel shape mounting bracket with keyhole slots for attachment to the mounting surface see Fig 3 it will be necessary to mark the location of the keyhole slots on the mounting surface and drill holes for fasteners not provided Use fasteners suitable for the mounting surface The narrow end of the keyhole slot should face up Attach grounding wire green or bare copper from the supply circuit to the mounting bracket with the green grounding at tachment screw provided Some models have a grounding wire attached to the fixture For models that employ a green or bare copper grounding wire it will be necessary to connect the green or bare grounding wire to the grounding conductor of the supply
6. ot provid ed CAUTION Refer to the relamping label located near the lam pholder for recommended maximum wattage do not exceed recommended wattage If applicable attach shades to fixture Some shades require the use of shade attachment screws Do not overtighten these screws ton much pressure could cause glass breakage See Fig 4 for placement of fabric spacer not supplied on ali mod els Outdoor wall fixtures must be caulked with suitable RTV or Silicone compound around the top and sides of the coverplate to reduce the chance of water intruding into the sphcing area Leave the bottom clear to allow moisture a means of escape Restore electricity and check the operation of your new light ing fixture