Home
Transition Networks F-SM-MM-06 User's Manual
Contents
1. OPERATION Using Status LEDs Use the status LEDs to monitor the Media Converter operation in the network Pwr Steady LED indicates connection to external AC and DC power Link left Steady LED indicates multimode fiber link connection Link right Steady LED indicates singlemode fiber link connection TX RX TX RX techsupport transition com Select the Transition Now Link for a Live Web Chat 3 F SM MM 06 CABLE SPECIFICATIONS TECHNICAL SPECIFICATIONS The physical characteristics must meet or exceed ANSI TI 646 1995 ITU G 957 For use with Transition Networks Model F SM MM 06 or equivalent specifications Product is certified by the manufacturer to comply with DHHS Rule 21 CFR y ply Bit Error Rate lt 10 10 Subchapter J applicable at the date of manufacture Multimode 1300 nm Standards ANSI TI 646 1995 ITU G 957 Recommended 62 5 125 um Data Rate 622 Mb s Optional 100 140 85 125 50 125 pm Case Dimensions 4 7 x 3 0 x 1 0 119 mm x 76 mm x 25 mm Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Weight 10 oz 283 g approximate Fiber Optic Receiver Sensitivity min 26 0 dBm max 14 0 dBm Link Budget 7 0 dB Power Consumption 3 1 W Minimum cable distance 2 meters 6 6 ft Power Supply 12VDC 0 4 A minimum Typical maximum cable distance 2 km 1 2 miles DC Output minimum output regulation 5 Connector 2 1mm barrel center pin positive Singlemode MTBF 51 185 hour
2. A CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkstorgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb
3. TRANSITION t networks Part Number Port One Fiber Optic USER S GUIDE F SM MM 06 Stand Alone Media Converter e OC 12 ATM SONET e Singlemode to Multimode Transition Networks F SM MM 06 Ethernet Media Converter extends ATM or SONET over singlemode fiber optic cable up to 40 km Port Two Fiber Optic F SM MM 06 SC 1300 nm multimode SC 1310 nm singlemode 2 km 1 2 miles 15 km 9 3 miles F SM MM 06 XL SC 1300 nm multimode SC 1310 nm singlemode 2 km 1 2 miles 40 km 24 9 miles Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the network See the Cable Specifications on page 4 for more information on the cable length Optional Accessories sold separately Part Number Description SPS 1872 SA Optional External Power Supply 18 72VDC Stand Alone Output 12 6VDC 1 0A SPS 1872 CC Optional External Power Supply 18 72VDC Piggy back Output 12 6VDC 1 0A E MCR 03 12 Slot Media Converter Rack includes universal internal power supply 17 x 15 x 5 in 432 x 381 x 127 mm WMBL Optional Wall Mount Brackets Length 4 0 in 102 mm Fits converter length 4 7 in 119 mm WMBV Optional Vertical Mount Bracket Length 5 0 in 127 mm WMBD Optional DIN Rail Mount Bracket Length 5 0 in 127 mm WMBD F Optional DIN Rail Mount Bracket flat Length 3 3in 84 mm Installation 242244000 60885008 2 Operat
4. at live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 RANSITION taS teu eke DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model F SM MM 06 Series Media Converters Part Number s F SM MM 06 F SM MM 06 XL Regulation EMC Directive 89 336 EEC Purpose To declare that the F SM MM 06 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 801 3 801 4 IEC 950 21 CFR subpart J I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s eee oe re january 1 1997 Stephen Anderson Vice President of Engineering Date techsupport transition com Select the Transition Now Link for a Live Web Chat 7 COMPLIANCE INFORMATION UL Listed C UL Listed Canada CISPR22 EN55022 Class
5. dieses Ger tes Rundfunkst rungen auftreten in weichen Fallen der Benutzer fur entsprechende Gegenma nahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors a l utilsateur de prende les measures sp cifiques appropri es Trademark Notice All trademarks and registered trademarks are the property of their respective owners Copyright Restrictions 1997 2003 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33055 C
6. ion esas ccs eee e eect es 3 Cable Specifications 4 Technical Specifications 5 Fault Isolation and Correction 6 ContactUs 2025 2Gh aaudcd es Ae 7 Compliance Information 8 F SM MM 06 INSTALLATION Installing the Cable FIBER 1 Locate or build fiber cable with male two stranded TX to RX connectors installed at both ends 2 Connect the fiber cables to the Media Converter as described e Connect the male TX cable connector the female TX port e Connect the male RX cable connector to the female RX port 3 Connect the fiber cables to the other device another media converter hub etc as described e Connect the male TX cable connector the female RX port e Connect the male RX cable connector to the female TX port Connect the fiber cable Connect the fiber cable to the Media Converter to the other device as shown media converter hub etc as shown _ _ FE H TX Power the Media Converter AC 1 Install the power adapter cord to the back of the Media Converter 2 Connect the power adapter plug to AC power Verify that the Media Converter is powered by observing the illuminated LED power indicator light DC Consult the User s Guide for the Transition Networks SPS1872 xx DC External Power Suppy for powering the Media Converter 2 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00
7. s MIL217F2 V5 0 MIL HDBK 217F Recommended 9 um 124 339 hours Bellcore7 V5 0 F SM MM 06 1310 nm Environment Tmra O to 50 C 32 to 122 F Fiber Optic Transmitter Power min 15 0 dBm max 8 0 dBm Storage Temp 20 to 85 C 4 to 185 F Fiber Optic Receiver Sensitivity min 28 0 dBm max 7 0 dBm Humidity 10 to 90 non condensing Link Budget 13 0 dB Altitude O to 10 000 feet Minimum cable distance 2 meters 6 6 ft Warranty eine Typical maximum cable distance 15 km 9 3 miles V stated E F SM MM 06 XL 1310 nm CAUTION Visible and Invisible Laser Radiation When Open Do Not Stare Fiber Optic Transmitter Power min 3 0dBm max 2 0 dBm Into Beam Or View Directly With Optical Instruments Fiber Optic Receiver Sensitivity min 29 0 dBm max 7 0 dBm Link Budget 26 0 dB CAUTION Use of controls adjustments or the performance of procedures Minimum cable distance 2 meters 6 6 ft other than those specified herein may result in hazardous radiation exposure Typical maximum cable distance 40 km 24 9 miles Actual distance is dependent upon the characteristics of the network installation 4 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00 techsupport transition com Select the Transition Now Link for a Live Web Chat 5 F SM MM 06 FAULT ISOLATION and CORRECTION If the Media Converter fails isolate and correct the failure by determining the answers to the following q
8. uestions and then taking the indicated action 1 Is the PWR LED on the Media Converter illuminated NO e Is the power adapter the proper type of voltage and cycle frequency for the AC outlet e Is the power adapter properly installed in the Media Converter and in the outlet e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 YES e Proceed to step 2 Is the multimode Link LED on the left illuminated NO e Check the fiber cables for proper connection e Verify that the TX and RX cables on the Media Converter are connected to the RX and TX ports respectively on the other device e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 YES e Proceed to step 3 Is the singlemode Link LED on the right illuminated NO e Check the fiber cables for proper connection e Verify that the TX and RX cables on the Media Converter are connected to the RX and TX ports respectively on the other device e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 YES e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 6 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00 CONTACT US Technical Support Technical support is avialable 7 00 AM 6 00 PM CST GMT 6 00 US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Ch
Download Pdf Manuals
Related Search
Related Contents
York 363857-YUM-A-0208 Air Conditioner User Manual Samsung B2310 دليل المستخدم BNP En matières d`animation Harvie Krumpet Halo RL560WH6940R Instructions / Assembly User`s Manual Astro-Smart External Dew Annihilator What is Alarm Rationalization? Model 700BF(I) Lire l`actualité du 8 au 12 novembre - AdDen avocats Manual Copyright © All rights reserved.