Model 700BF(I)
Contents
1. m 257 8 657 gt TOP VIEW DRAWER PANEL THICKNESS NOT INCLUDED SUB ZERO Planning Information Model 7OOBF I INTEGRATED MODEL OPTIONS v All Freezer Drawers 700BF All Freezer Drawers with Automatic Ice Maker 700BFI PANEL OPTIONS v Integrated custom panels Classic Stainless Steel Finish S Platinum Stainless Steel Finish P Carbon Stainless Steel Finish B Stainless steel drawer front panels are ordered and shipped as sales accessories and include tubular handles ACCESSORIES gt Tubular handles in classic platinum and carbon stainless steel gt Dual installation heater kit BBDUAL Accessories are available through your Sub Zero dealer To obtain local dealer information visit the Locator section of our website subzero com Dimensions in parentheses are in millimeters unless otherwise specified SPECIFICATIONS v Model 700BF I All Freezer Drawers Overall Width 27 686 Overall Height 341 2 876 Overall Depth 24 610 Freezer Capacity 5 1 cu ft 144 L Minimum Height levelers in 34 864 Drawer Clearance 191 2 495 Electrical Requirements 115 V AC 60 Hz 15 amp circuit Plumbing Requirements 1 4 copper line Water Supply 20 100 psi Annual Energy Usage 488 kWh 41 based on 8 29 cents per kilowatt hour Shipping Weight 190 Ibs 86 kg Special Note Drawer panels and handles are available in three stainles
2. CABINETRY APPLICATIONS Integrated refrigeration is compatible with virtually any style and look of cabinetry The models can be used with framed as well as frameless cabinets Because of the precise application and the look you may want to achieve there are important questions you need to answer before ordering panels for the drawers As you look at styles of cabinets keep some important facts in mind Weight Limitations The weight of each drawer panel cannot exceed 12 Ibs 5 kg Panel Thickness Drawer panels must be a minimum of 5 8 16 thick The toe kick clearance can vary with the height of the lower drawer panel the maximum panel height is 1611 16 424 You must keep a minimum space of 4 102 clear below the bottom edge of the lower drawer panel so the unit can be properly vented We recommend using D style handles Locate handles in the top center area of the drawer panels IMPORTANT NOTE The depth of each Integrated unit is 24 610 from the front of the unit to its back You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit SUB ZERO Planning Information Model 7OOBF I INTEGRATING CABINETRY E INTEGRATED FRAMED CABINETRY v SUB ZERO CABINET UNIT TO WALL FRAME CABIN
3. ET DOOR gt Traditional Frame full overlay 24 SUB ZERO CABINET UNIT TO WALL FRAME CABINET 1 8 3 PANEL DOOR REVEAL gt Traditional Frame standard overlay 24 SUB ZERO UNIT TO WALL CABINET FRAME m CABINET DOOR m gt Traditional Frame 3 8 10 offset Dimensions in parentheses are in millimeters unless otherwise specified FRAMED CABINETRY APPLICATIONS Framed cabinetry applications present you with different questions to address The illustrations on this page show common applications of framed cabinetry These are not meant to be the only alternatives but are suggestions from designers around the country Also refer to the full scale illustrations at the end of this section for specifics on door openings IMPORTANT NOTE The depth of each Integrated unit is 24 610 from the front of the unit to its back You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit Refer to the illustrations Illustrations on the following pages give dimensions for an Integrated base or tall unit installed within a framed cabi netry beaded inset application Review the illustrations giving particular attention to the overal
4. SUB ZERO Planning Information Model 700BF I All Freezer Drawers INTEGRATED Model 700BF Model 7OOBFI with Ice Maker Seamless molding Location of serial number Magnetic drawer gaskets Front venting with removable kickplate gt The Sub Zero Model 7OOBF and 7OOBFI integrated design accepts custom wood or stainless steel drawer panels Stainless steel panels and handles are available as sales accessories in three finishes classic platinum and carbon Dimensions in parentheses are in millimeters unless otherwise specified 10 05 Electronic digital control panel Upper freezer storage drawer Automatic ice maker Model 700BFI Lower freezer storage drawer These appliances are Star K certified from the factory to meet strict religious regulations in conjunction with specific instructions found on star k org No extra wiring harness is required one using this two drawer unit in conjunction with a Model 601R all refrigerator Many customers do not have the need for lots of freezer storage in their home With the emphasis on fresh food customers need more refrigerator space Now you can satisfy this need with the combination outlined above There is one temperature for the entire unit and the range you have is from 5 F 20 C to 5 F 15 C Also keep in mind that this unit can be ordered with and without an ice maker SUB ZERO Planning Inf
5. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit This will require a minimum rough opening depth of 25 635 See Installation Instructions shipped with unit for detailed specifications Dimensions in parentheses are in millimeters unless otherwise specified SUB ZERO Planning Information Model 7OOBF I INSTALLATION NOTES gt Refer to the illustrations and specifications for overall dimensions finished rough opening dimensions and installation specifics gt The depth of Model 7OOBF I is 24 610 from the front of the unit to its back Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit This will require a minimum rough opening depth of 25 635 Refer to the installation illustration gt The anti tip bracket must be installed to prevent the unit from tipping forward gt Integrated units are compatible with virtually any style of cabinetry They can be used with framed as well as frameless cabinets gt The weight of each drawer panel cannot exceed 12 Ibs 5 kg Drawer panels must be a minimum of 5 8 16 thick gt For the bottom drawer the maximum panel height is 1611 16 424 You must keep a minimum space of 4 102 clear below the bottom edge of the lower drawer panel so the unit can be properly vented In addition any decorative base molding must be removable for possible servicing and cleaning of the cond
6. enser gt We recommend using D style handles which should be located on the top center area of the drawer panel gt Two Integrated units may be installed next to one another Refer to page 10 for additional information gt For Integrated models with an automatic ice maker rough in the water supply line Connect a 1 4 OD copper line to the house supply being sure to use an easily accessible shut off valve between the supply and the unit This shut off valve should not be installed behind the unit gt Do not use self piercing valves A saddle valve kit 4200880 is available from your Sub Zero dealer To obtain local dealer informa tion visit the Locator section of our website subzero com Dimensions in parentheses are in millimeters unless otherwise specified gt Aline filter is required when water condi tions have a high sediment content The ice maker operates on water pressure of 20 psi 1 4 bar to 100 psi 6 9 bar In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently gt When routing the water through the side walls you must place the water line within 1 2 13 of the floor and as close as possible to the back wall The line must be routed around the anti tip bracket so it clears the bracket and leveling feet of the unit Refer to the installation illustration for placement of the water line gt Do not route water supply line
7. in front of the compressor tray The tray must be slid forward for service gt Regardless of the routing allow for 27 686 of excess copper tubing to remain outside the wall or floor for easy connection to the unit as shown in the installation illustration gt A115 volt 6OHz 15 amp circuit breaker and electrical supply are required A separate circuit servicing only this appliance is necessary gt All Integrated models are equipped with a power supply cord with a 3 prong grounding plug which must be plugged into a mating 3 prong grounding type wall receptacle The electrical outlet must be placed so the ground ing prong is to the right of the thinner blades The outlet must be flush with the back wall Locate electrical within the shaded area shown in the installation illustration gt Do not use an extension cord or two prong adapter Electrical ground is required on this appliance Do not under any circumstances remove the power supply cord ground prong gt You must follow all National Electrical Code regulations In addition be aware of local codes and ordinances when installing your service gt The Integrated Installation Guide packed with the appliance will give you step by step proce dures for making sure the unit is installed properly SUB ZERO Planning Information Model 7OOBF I INTEGRATING CABINETRY INTEGRATED Dimensions in parentheses are in millimeters unless otherwise specified
8. l panel specifica tions SUB ZERO Planning Information Model 7OOBF I FRAMED CABINETRY BEADED i 24 GW SUB ZERO TO WALL CABINET DOOR A TOP VIEW A ALL REVEALS ARE 1 8 3 INSET APPLICATION y The illustration shows an Integrated base unit installed within a framed cabinetry beaded inset application IMPORTANT NOTE Dimensions are based on a 1 8 3 reveal A reveal of up to 1 4 6 is possible but panel dimensions need to be adjusted accordingly B DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS C BOTTOM RAIL MUST BE REMOVABLE DIMENSIONS MAY VARY SHADED AREA INDICATES STATIONARY STYLES AND RAILS m 263 4 679 gt PANEL WIDTH INTEGRATED 1341 2 876 686 4 11 2 38 FRONT VIEW Installation of an Integrated base unit within framed cabinetry Dimensions may vary Dimensions in parentheses are in millimeters unless otherwise specified 11 38 4 102 GO SIDE VIEW SUB ZERO Planning Information Model 7OOBF I i FRAMELESS CABINETRY APPLICATIONS The illustration below shows a hypothetical installation of m a Integrated base unit within frameless cabinetry Review INTEGRATED the illustration giving particular attention to the overall panel specifications IMPORTANT NOTE Dimensions are based on a 1 8 3 reveal A reveal of up to 1 4 6 is possib
9. le but panel FRAMELESS CABINETRY V dimensions need to be adjusted accordingly 263 4 679 gt lt an gt PANEL WIDTH Gio A 7 i 139 16 345 A PE Fo 876 1611 16 424 Y a 102 y A Ps 27 gt TOE KICK S85 SIDE VIEW FINISHED OPENING A ALL REVEALS ARE 1 8 3 DIMENSIONS MAY VARY Installation of an Integrated base unit within frameless cabinetry Dimensions may vary Dimensions in parentheses are in millimeters unless otherwise specified SUB ZERO Planning Information Model 7OOBF I CABINETS 3 27 i TOP VIEW gt Installation without side panels CABINETS 27 E MINIMUM 5 8 16 SIDE PANELS gt lt gt Installation with side panels CABINETS Waa GEE TOP VIEW gt Installation of two units side by side CABINETS 27 E MINIMUM 5 8 16 SIDE PANELS gt Installation at end of run Dimensions in parentheses are in millimeters unless otherwise specified INTEGRATED INSTALLATION OPTIONS The illustrations on this page show some typical installations and their dimension considerations The depth dimension in the illustrations may vary depending on cabinet styles treatment of counter tops or other design options IMPORTANT NOTE The depth of each Integrated unit is 24 610 fro
10. m the front of the unit to its back Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit This will require a minimum rough opening depth of 25 635 Refer to the illustrations DUAL INSTALLATIONS If two or more Integrated models are installed side by side where there is 2 51 or less of space between the units a heater kit is recommended TTDUAL for two tall units installed side by side and BBDUAL for two base units or a base unit and a tall unit installed side by side These optional compo nents are available through your Sub Zero dealer 10 SUB ZERO Model 7OOBF I INTEGRATED TOE KICK AREA DETAIL v Planning Information TOE KICK CLEARANCE The toe kick clearance can vary with the height of the lower drawer panel the maximum panel height is 1611 16 424 IMPORTANT NOTE You must keep a minimum space of 4 102 clear below the bottom edge of the lower drawer panel so the unit can be properly vented In addition any decorative base molding must be removable for possible servicing and cleaning of the condenser The illustration below shows the area below the lower drawer where the operating mechanical equipment of the Integrated unit is housed IMPORTANT NOTE The depth of each Integrated unit is 24 610 from the front of the unit to its back Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit This will require a minimum r
11. ormation Model 7OOBF I FEATURES gt Base unit with freezer storage drawers gt Model 7OOBFI has automatic ice maker gt Integrated design for point of use refriger ation anywhere in the home gt Refrigeration system ensures the best food storage and energy efficiency gt Microprocessor offers precise temperature control gt Electronic digital controls are easily accessed in the top storage drawer OVERALL DIMENSIONS v 27 p 686 go y 3 8 UNIT DIMENSION UNIT DIMENSION 10 gt Flat to the ceiling bright lighting in storage drawers gt Alarm will let you know with an audible beeping if a drawer is left open gt Top drawer has a removable divider gt Meets strict Department of Energy requirements gt UL approved for US and Canada gt Two five and twelve year residential warranty exclusions apply warranty information can be found on our website subzero com INTEGRATED S gt He e S5 131 4 NY DRAWER 1 2 337 MOUNTING DETAIL 13 t oo oo o o n he aaa 101 4 876 260 i 203 8 93 4 518 248 I T Y FRONT VIEW aog SIDE VIEW 1 2 13 ADJUSTMENT IN LEVELING LEGS Dimensions may vary by s 3 Dimensions in parentheses are in millimeters unless otherwise specified 24 610 DRAWER CLOSED gt lt 191 2 495
12. ough opening depth of 25 635 Refer to the illustration 10 268 PANEL 164 424 PANEL 10 254 OPTIONAL BASE MOLDING MUST BE REMOVABLE 67 5 a 23 To 4 gt 102 iia FLOOR 24 TO WALL A Dimensions in parentheses are in millimeters unless otherwise specified 11
13. s steel finishes Specifications are subject to change without notice SUB ZERO Planning Information Model 7OOBF I INSTALLATION SPECIFICATIONS TOP VIEW TOP VIEW A i 1 p A t A m t antie 6 L 11 2 BRACKET i 152 ANT TIP 38 431 a gt a0 k 131 2 BRACKET i INTEGRATED 25 843 c 27 843 c 27 EE 1 9 9 L 9 lt 15 1 2 t gt gt pa a SIDE ENTRY WATER LINE LOCATIONS H BOTTOM ENTRY P Y LOCATION Y Y 11 2 gt 11 2 38 38 27 686 WATER LINE SIDE ENTRY NOTE ANTI TIP BRACKET MUST BE INSTALLED TO ANTI TIP LOCATION PREVENT UNIT FROM TIPPING FORWARD BRACKET Va FRONT VIEW SIDE VIEW LOCATE ELECTRICAL WITHIN SHADED AREA ORIENT GROUND PRONG TO RIGHT AS SHOWN ANTI TIP BRACKET LOCATE WATER LINE REAR ENTRY WITHIN SHADED AREA lt 13 330 gt lt 9 gt 1 4 9 229 3 4 a L21 cosy 19 41 2 114 3 76 151 2 394 gt Dimensions may vary by 1 8 3 DIMENSIONS v Finished Rough Opening Width 27 686 Finished Rough Opening Height 341 2 876 Finished Rough Opening Depth 25 635 Location of Electrical Within shaded area Location of Plumbing Within shaded area The depth of the Model 700BF I is 24 610 from the front of the unit to its back
Download Pdf Manuals
Related Search
Related Contents
Memory BIST Training Workbook JVC 0405AIMMDWJEM Stereo System User Manual Permactive RF manual.pub Land Pride RCR18 User's Manual PEDAGOGIA, CURRÍCULO E LITERATURA INFANTIL TRICOTINS FACILES 議事録 - 総務省 Einstellungen Olympus 1040 Digital Camera User Manual Moog DS2100 User's Manual Copyright © All rights reserved.