Home
TOA Electronics C-RM500 User's Manual
Contents
1. i pee O ae Camera control Alarm input 3 cable cable E ae 5 L A a 10 i i o 0 Combinati o 5 10 Sensor ombination camera is Eo 1 A 1 oo 2 Camera control Alarm input i i Monitor TV z 3 cable cable 4 1 5 i 9 i o 0 5 10 Sensor Combination camera The use of each camera s alarm input permits connection of 8 sensors for each camera Alarm input unit ALARM REMOTE IN C AL80 bkeeeeeeeeeeee als beeeeeeeeceeeeeee oe ah RS 232C 47 48 7 5 Connection When Controlling the System from 2 Locations By connecting 2 C RM500 Remote Controllers the system can be controlled from 2 locations Set the operation mode of one controller for MASTER and the other controller for SLAVE Refer to p 24 Operation mode Note Set the I O SPEED REMOTE of the MASTER designated C RM500 Controller and I O SPEED SWITCHER of the SLAVE designated C RM500 Controller to the same transfer rate Refer to p 29 O SPEED Slave unit remote control terminal GND ooieoe
2. 01 02 Camera number 03 04 l GROUP i Step 2 Press the 4 Segment Split Screen SELECT Montor seen LOroup 2 key again or the Group Selector key The images of camera numbers 5 8 or Group 2 will be displayed on the 05 06 monitor 07 08 GROUP Monitor screen Group 3 SELECT Step 3 Repeat Step 2 to display other succeeding the images of camera or numbers The displayed camera 09 10 group is switched to Group 3 Cameras 9 12 Group 4 Cameras 13 16 and then back to Group 1 each time the 4 Segment Split Screen key is pressed 5 2 7 Viewing sequential displays The outputs of all cameras connected to the switcher can be displayed on the monitor in sequential order at viewing intervals preset at the switcher For details refer to the instruction manual included with the switcher Sequential full screen viewing SEQUENCE LCD screen Press the Sequence key The images for Cameras 1 16 are SEQUENCE displayed in sequential order Note that if the Tour Sequence function has been set the Monitor screen camera images will be switched Camera No 1 Camera No 3 in the order of the specified reproduction number Refer to p 39 Tour sequence Note In this example Camera No 2 is not displayed on the monitor because it is Camera name Camera name not connected Camera No 16 booom Camera name Sequential 4 segment split screen
3. 2 5 8 Jo SET key REMOTE CONTROLLER C RM500 Freeze key Control key Full screen key 5 2 1 Displaying the camera number only active when the Multi Switcher is connected CH Step 1 Press the Channel Call key while a camera image is displayed on the monitor All connected camera numbers will be displayed Note The camera number is displayed even when the camera is not connected When confirming the camera number and operating its display Step 2 Enter the camera number with the numeric keypad Step 3 Press either the Full Screen or Freeze Screen key The camera image will be displayed in full screen or freeze screen format LCD screen CHANNEL CALL Monitor screen 10 segment split screen display 13 5 2 2 Viewing the freeze screen only active when the Multi Switcher is connected Example Step 1 Enter the camera number to freeze using the numeric keypad Step 2 Press the Freeze Screen key The F indication will flash on the corresponding camera image screen Step 3 Repeat Steps 1 and 2 to freeze other camera images Note In a system using the RS 232C to control the Multi Switcher the freeze screen display is only possible when the full screen mode is selected Simultaneously resetting all freeze displays Press the Freeze Screen key Resetting individual freeze displays Step 1 Enter the
4. ni U 13 CHANNEL CONTROL This camera can be operated CONTROL LCD screen Ae Camera name Lights 13 CONTROL Monitor screen 10 segment split screen display 10 5 1 2 Rotating the camera with the joystick Any connected Combination camera can be rotated in the desired direction using a joystick With the camera selected tilt the joystick in the direction in which the camera is to be rotated The camera will rotate in the direction the joystick was tilted Example When panning the camera to the right LCD screen MANUAL Joystick 5 1 3 Activating the wiper When a Combination camera with built in wiper is connected to the system the wiper can be activated using the Wiper key WIPER Press the Wiper key while the camera is selected LCD screen The camera s built in wiper is activated while the key is held down 5 1 4 Activating the defroster When a Combination camera with built in defroster is connected to the system the defroster can be activated using the Defroster key aie DEF Step 1 Press the Defroster key while the Lights LCD screen camera is selected DEFROSTER The defroster indicator will light and the camera s built in defroster will be DEF DEF activated Step 2 Press the Defroster key again The defroster indicator will extinguish and the defroster will stop
5. GND Switcher control terminal Example C RM500 MASTER I O SPEED REMOTE 9600 bps C RM500 SLAVE I O SPEED SWITCHER 9600 bps C RM500 Operation mode MASTER 0000000000000 00000000000000 Shielded twisted pair cable 0000000000000 00000000000000 C RM500 Operation mode SLAVE 7 6 Alarm Output Control Input Terminal Connections 7 6 1 Pin functions Shown below are the numbers and names of the Alarm I O terminal pins Alarm output control input emea YY 13 1 ooo0oo0o000000000 AA a E C RM500 Function Function Ground Alarm Output 10 Alarm Output 1 Alarm Output 11 Alarm Output 2 Alarm Output 12 Alarm Output 3 Ground Ground Alarm Output 13 Alarm Output 4 Alarm Output 14 Alarm Output 5 Alarm Output 15 Alarm Output 6 Alarm Output 16 Ground Alarm Output Alarm Output 7 Alarm Input Alarm Output 8 Home Position Selection Input Alarm Output 9 Auxiliary Input Ground CO N OD or A OJIN Alarm Output Terminal Pin No 1 16 The terminal of the number corresponding to the alarm activated camera number shorts with the ground terminal Alarm output terminals 1 16 are the NPN open collector output Operating current Maximum 20 V 20 mA Alarm Output Terminal Pin No 22 This terminal is shorted with the g
6. Step 4 Tilt the joystick left or right to select the desired Example setting content Tip eee gt Se RETURN Pressing the Clear key before Step 4 is 10SEC completed will return the display to the screen DOWN last shown in Step 2 before the SET key was pressed Step 5 Press the SET key to confirm the setting Step 2 contents SET gt AUTO RETURN The display returns to the screen in Step 2 to O select the setting item a Step 6 Repeat Steps 2 5 to continue to set other items Press the Menu key when returning to the normal screen after setting completion 23 24 6 4 Setting the Functions Perform the following settings referring to the Basic Setting Operations on p 23 6 4 1 Operation mode Sets the unit s operation mode Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select OPERATION MODE and confirm it by pressing the SET key The setting contents will be displayed on Line 2 OPERATION MODE 1 MASTER Step 3 Tilt the joystick left or right to select either of the following setting contents and confirm it with the SET key Setting contents 1 MASTER Be sure to select Master when only a single C RM500 unit is used When 2 units are connected set either unit as the Master and the other as SLAVE 2 SLAVE When 2 units are connected set either unit as SLAVE and the other as MASTER Note Operation mode is set as 1
7. Tilt the joystick to the left or right or use the numeric keypad to enter the designed abbreviated number and confirm the setting with the SET key Enter a number from 1 512 The flashing cursor moves to the camera number Enter the camera number using the numeric keypad and confirm with the SET key Enter a number from 1 to 999 The flashing cursor moves to the position number Enter the position number with the numeric keypad Enter a number from 1 to 255 Tip Entering 0 will switch the screen to full screen display and will not execute position playback Setting the camera s alarm contact output After confirming the camera number and position number the flashing cursor will move to the rightmost position Step 6 Step 7 Step 8 Tilt the joystick to the left or right to select either space or If is selected the camera s auxiliary contact output 2 can be set to be made when the camera designed with the abbreviated number receives an alarm signal Press the SET key to confirm the settings The procedure returns to Step 3 Repeat Steps 3 6 to continue setting other abbreviated numbers Press the Clear key to return to the setting item display Deleting Settings After pressing the Alarm Reset key press the SET key Abbreviated No ABBREVIATION 1 512 CAMxx POS Position No Camera No ABBREVIATION CAM x POS Example L
8. Combination camera Combination camera Combination camera Remote Controller C RM500 e a Kor a b c lt 1 2km Connected Camera Termination Switch Setting Make sure that the termination switches of the cameras connected to the system are set as follows Cameras other than the last connected camera Termination switch OFF Last connected camera Termination switch ON Remote Controller C RM500 Combination camera Terminal switch OFF Combination camera Terminal switch OFF Combination camera Terminal switch ON 44 7 3 Connection to the Multi Switcher s RS 232C Terminal e When connecting the camera s video output cable to the Multi Switcher match the Multi Switcher s camera input terminal number with the camera s address number e The C CC551 and C CC554 Combination cameras permit settings of up to 255 camera positions camera orientation and the C CC501 and C CC504 permit settings of up to 64 positions All are equipped with 8 alarm input terminals To expand the alarm input connect the C AL80 Alarm Input Unit to the C RM500 Remote Controller e To switch the display to the fixed camera output when an alarm signal is received connect a sensor to the switcher s alarm input terminal that corresponds to the video input number the fixed camera is connected to RS 232C reverse cable ee Female D sub 9 pin connector to Femal
9. 5 2 6 Viewing multi screen displays only active when the Multi Switcher is connected 16 segment split screen viewing ccceeceeeeeeeeeeeeeeeeeeaeeeeeeeeeeteeeeees 10 segment split screen viewing 2 ccceeceeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeeees 9 segment split screen viewing 2 ceeeeceeceeeeeeeeeeeeeeaeeaeeeeeeeeeeteeeeees 4 segment split screen viewing 2 ceeeeceeceeeeeeeeeeeeeececaeeeeeeeeeeeeeeeees 5 2 7 Viewing sequential displays Sequential full screen viewing ccceeeeceeeeeeeeeeeeeeeeeeeeeaeeeseeeeeeaeeeeaeeee Sequential 4 segment split screen VIEWING ccccseeecessteeeeeesssteeeeeees 5 3 Alarm Hold and Reset 5 3 1 Holding the alarm ssori eniaint iaeiae seats 5 3 2 Displaying alarm activated camera images cceeeeeeeeeeeteeeeeeeeeeeeeeeetees 5 3 3 Resetting the Alarm keener eE AEEA EEEE SRA RA 6 SETTINGS 6 1 Setting Items and Their Descriptions 0 ceeceeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeaeeeeeaeeeeeas 21 6 2 Operating Keys and Display Screen ccceceeeeeeeeeeeeeeeeeeeeeaeeeseeeesecaeessaeeseaes 22 6 3 Basic Setting Operations cceceeceeseeeceeeeeeeneeeeeeeeeeeeaeeeeeeeeeeeaeeeseeeeseaeeseaeeeeeas 23 6 4 Setting the Functions 6 4 1 Operation mode 00 eee ececcececeeeeenee cence eeeeaeeeneeeeeeaaeeeseeeeeesaeseeeneeseaeeeeeaeeeeeas 24 6 42 27 SWilGHErs wissses sits etic ia Nantel fe wetbes i ycPrastel Pa
10. SECURITY RELATED FUNCTIONS OF THIS PRODUCT 1 SAFETY PRECAUTIONS e Be sure to read the instructions in this section carefully before use e Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included e We also recommend you keep this instruction manual handy for future reference Do not expose the unit to rain or an environment where it may be AN WARNING splashed by water or other liquids as doing so may result in fire or electric shock A WAR N l NG Indicates a potentially hazardous situation which if mishandled could result in death or serious personal injury e Use the unit only with the voltage specified on the unit Using a voltage higher than that which is specified may result in fire or electric shock e Do not cut kink otherwise damage nor modify the power supply cord In addition avoid using the power cord in close proximity to heaters and never place heavy objects including the unit itself on the power cord as doing so may result in fire or electric shock e Avoid installing or mounting the unit in unstable locations such as on a rickety table or a slanted surface Doing so may result in the unit falling down and causing personal injury and or property damage e Should the following irregularity be found during use immediately stop the power supply to the unit and contact your nearest TOA dealer Make no furth
11. a D U 5 1 5 Controlling an auxiliary contact The Combination camera s Auxiliary Contact Output 1 can be switched ON and OFF Step 1 Press the Auxiliary key while the iie LCD screen camera is selected The Auxiliary indicator will light and the gt AUXILIARY SW auxiliary contact is switched ON x Step 2 Press the Auxiliary key again The Auxiliary indicator will extinguish AUX and the auxiliary contact is switched st reas AU A U 5 1 6 Activating the automatic functions When a Combination camera is connected to the system its automatic functions can be enabled using the Auto key AUTO AUTO Step 1 Press the Auto key while the camera 4 Lights LCD screen is selected The camera s automatic AUTO functions Auto Pan Auto Trace gt L or Preset Sequence 3 will begin to operate Set the automatic functions to be enabled on the Camera Menu Refer to p 40 1 The camera s automatic panning function 2 Automatic repetition of manual camera operations that have been stored in memory 3 Automatic sequential display of camera positions in the order that their position numbers were selected AUTO AUTO Step 2 Press the Auto key again The Auto indicator extinguishes and automatic operations are stopped 5 1 7 Activating the zoom
12. 1 3 Activating the Wiper ooo e cece et eeee eee eeeeeeeeeeeeeeaeeeeeeeeaeeeeeeeeeaeeeeeeeeaaeees 5 1 4 Activating the defroster 0 eeccceceeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteneaeeeeeeeeaaeees 5 1 5 Controlling an auxiliary contact 0 0 ee cece ee ceeeeeeceeeeeeeeeeetaeeeeeaeeseeeeeeeaeersaes 5 1 6 Activating the automatic FUNCTIONS ec e eeeeeeeeeeteeeeeeeeeeeteeeaeeeeeeeeaeees 5 1 7 Activating the ZOOM FUNCTION oe eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeaaeees 5 1 8 Activating the focus FUNCTION eee eect eeeeeee eee eeeeeeeeeeeeeeeeeeeeeneaeeeeeeeeaaeees 5 1 9 Changing the lens speed ccsccceeeeeeeeeeeeeeeeeeeeaeeeeeeeeseaaeseeaaeeseaeeeeeaeeesaes 5 1 10 Activating the auto focus FUNCTION e ec eeceeeeeeeeeeeteeeeeeeeeteeeeeeeeeeneaaeees 5 1 11 Selecting the Camera position ececceeceeeeeeeeeeeeeeeeeeeeaeeeeaeeeeeaeeeeeaeeteaes 5 2 Monitor Display 5 2 1 Displaying the camera number only active when the Multi Switcher is Connected cscccesseteeeeees 5 2 2 Viewing the freeze screen only active when the Multi Switcher is Connected ccsccceeseeeeeeees 5 2 3 Using the Function Keys o oo eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeseeeaeeeeeeeeaeeees 5 2 4 Using the abbreviated numbers cc cceeeeeeeeeeeeeeeeeeeeeeeeeeeeeteneaeeeeeeeeaaeees 5 2 5 Viewing full screen displays eeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeaaeees
13. MASTER by the factory 6 4 2 Switchers Sets the type of switcher to be connected to the unit Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select SWITCHER and confirm it with the SET key The setting contents will appear on Line 2 SWITCHER 1 161NPUT Step 3 Tilt the joystick left or right to select one the following setting contents and confirm it with the SET key Setting contents 1 16 INPUT Select this setting when the 16 channels Multi Switcher is connected to the switcher control terminal RS 485 Select this setting when the system includes a switcher other than Multi Switcher or Smart Switcher and the number of control channels is 16 or less 2 9 INPUT A Select this setting when the 9 channels Multi Switcher is connected to the switcher control terminal RS 485 and Camera 9 s 4 segment split screen display is set for OFF in the Multi Switcher settings 3 9 INPUT B Select this setting when the 9 channels Multi Switcher is connected to the switcher control terminal RS 485 and Camera 9 s 4 segment split screen display is set for ON in the Multi Switcher settings 4 16 INPUT 2 Select this setting when the 16 channels Multi Switcher is connected to the switcher control terminal RS 232C 5 9 INPUT A 2 Select this setting when the 9 channels Multi Switcher is connected to the switcher control terminal RS 232C and Camera 9 s 4 segment split scr
14. OFF be sure to connect the optional C AL80 Alarm Input Unit e This selection is set to 1 ON by the factory 6 4 12 Camera check Checks Combination cameras connected to the camera control terminal for 30 seconds Note Once the Camera Check has been completed only the cameras connected when the check was made can be controlled Therefore be sure to perform the camera check again whenever new cameras are added Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select CAMERA CHECK and confirm the selection with the SET key The check takes approximately 30 seconds All keys are disabled during the check The check interval is counted down from 30 seconds displayed to the right of Line 1 The camera numbers of the connected Combination cameras are displayed in numerical order on Line 2 Example CAMERA CHECK 20 1 2 10 15 16 20 The indication OK is displayed after the 30 second check is completed CAMERA CHECK OK 1 2 10 15 16 20 After check completion connected cameras can be confirmed by tilting the joystick to the left or right to scroll the screen CAMERA CHECK OK CAMERA CHECK OK 1 2 10 15 16 20 gt 30 RIGHT LEFT IGHT or Step 3 Press the Clear key to return to the menu screen 33 34 6 4 13 Camera alarm preset Sets the position number to automatically change the Combination camera s orientation when an alarm signal is received from the c
15. at the specified time interval Viewing intervals are set at the switcher CH call key 2 Displays the camera number on the monitor for a preset period of time This key is convenient for finding the camera number when no indication or only the camera name is displayed Menu key Displays the menu on the Remote Controller s LCD screen for setting functions To enable press lightly with a pointed object When the menu is opened and the desired item is selected the screen under the setting will be displayed Pressing the key again will close the setting screen and the display will disappear LCD screen Displays character information for the setting menu numeric keypad input status current operation etc Zoom key Sets the Combination camera s zoom lens for TELESCOPE or WIDE ANGLE operation The Zoom key can only be used while the Control indicator is on Focus key 2 Sets the Combination camera s zoom lens for FAR or NEAR operation The Focus key can only be used while the Control indicator is on Lens speed key Indicator Adjusts the speed of lens operation when the Zoom or Focus key is pressed Joystick 3 Controls the attached pan tilt head s horizontal and vertical movement The joystick can only be used while the Control indicator is on 18 19 20 21 22 23 24 25 26 Numeric keypad 0 9 Used to enter the camera number position number abbreviated numb
16. o ABBREVIATION 8 CAM POS 1 Example AOR ABBREVIATION 18 CAM28 POS Example ABBREVIATION 18 CAM28 POS116 ABBREVIATION 18 CAM28 POS116 ARAR 6 4 20 Tour sequence The Tour Sequence function switches multiple camera outputs in sequence at a set time interval Merely pressing the Sequence key permits up to 128 camera outputs to be displayed on the full screen in the order of their set playback number The camera number position number and viewing time can be set for individual playback numbers Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Press the Menu key to display the menu screen Tilt the joystick up or down to select TOUR SEQ and confirm the selection with the SET key The unit will wait for the entry of YES to use the function or NO to not use the function Set by the factory Tilt the joystick to the left or right to select either YES or NO and confirm the entry by pressing the SET key The setting is displayed on Line 2 if YES is selected and the unit switched to Playback Number Entry Waiting mode Note that when the camera number or the position number is not programmed in advance the x x indication is displayed in place of the number Enter the playback number using the numeric keypad or by tilting the joystick to the left or right and confirm the entered
17. the outlet may cause damage to the power cord resulting in fire or electric shock When removing the power cord be sure to hold its plug to pull e Avoid installing the unit in humid or dusty locations in locations exposed to the direct sunlight near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock e Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage e Contact your TOA dealer as to the cleaning If dust is allowed to accumulate in the unit over a long period of time a fire or damage to the unit may result e If dust accumulates on the power supply plug or in the wall AC outlet a fire may result Clean it periodically In addition insert the plug in the wall outlet securely e Disconnect the power supply cord for safety purposes when cleaning or leaving the unit unused for 10 days or more Doing otherwise may cause a fire or electric shock 2 GENERAL DESCRIPTION The TOA C RM500 Remote Controller is used to remotely control TOA s Combination cameras over communication lines RS 485 It can remotely control video image switching and cameras in combination with TOA s Multi Switcher or Smart Switcher 3 FUNCTIONS e Display Selection The following screen formats can be selected for display of camera images connec
18. viewing m Press the sequential 4 LCD screen iD l Segment Split Screen key Tip The Program Sequence function is made operational Monitor screen when the Smart Switcher is Group 1 Group 2 connected For details refer to the instruction manual included with the Smart Switcher Camera name Group 4 5 3 Alarm Hold and Reset The Alarm can be held or reset when 1 KEY has been selected in the Alarm Hold setting and is not activated when 2 ALWAYS has been selected Refer to p 36 Alarm hold 5 3 1 Holding the alarm Press the Alarm Hold key The Alarm Hold indicator light will flash RESET HOLD RESET HOLD C1 Flashes LCD screen o Co Ch gt OH When an alarm signal is received during Alarm Hold The Alarm Reset indicator light flashes while the AL HOLD indication is displayed on the monitor RESET HOLD RESET HOLD Monitor screen Flashes 4 segment split screen display OO gt CO H 5 3 2 Displaying alarm activated camera images Press the Alarm Hold key The Alarm Hold indicator light will extinguish displaying the alerted camera image on the monitor in full screen format RESET HOLD RESET HOLD Monitor screen ALARM 5
19. 2 00800o000000000 oo a C RM500 Smart switcher Monitor TV Alarm input unit Monitor TV Alarm input unit 7 2 Connection to Combination Cameras Connect the Combination camera s control cable to the unit s Camera Control terminal making sure to match their polarities C RM500 Operation mode MASTER Camera control terminal GND OlOlO O O 0000000000000 00000000000000 Shielded twisted pair cable Video output cable Camera control cable Monitor TV Combination camera Connection cables e Recommended cable type CPEV S type shielded twisted pair cable thicker than 0 65 mm in diameter e The maximum cable distance between the unit and the Combination camera is 1 2 km when connected in a matched pair If multiple cameras are connected to a system the maximum distance between connected equipment is 1 2 km in total
20. 3 3 Resetting the alarm Press the Alarm Reset key The Alarm Reset indicator light will extinguish resetting the alarm state RESET HOLD RESET HOLD Monitor screen CI CI o CI ae UL 01 02 03 04 Note The alarm cannot be reset when 2 LEVEL has been selected in the Alarm Signal setting The state of alarm continues as long as an alarm signal input is received Refer to p 35 Alarm signal 20 6 SETTINGS 6 1 Setting Items and Their Descriptions Operation mode Refer to p 24 Switcher Refer to p 25 Contact point Refer to p 26 Automatic reset Refer to p 27 Home position Refer to p 28 I O speed Refer to p 29 Buzzer Refer to p 30 Initial screen Refer to p 30 Channel designation Refer to p 31 Sensor alarm Refer to p 32 Camera alarm Refer to p 32 Camera check Refer to p 33 Camera alarm preset Refer to p 34 Alarm signal Refer to p 35 Alarm interval Refer to p 35 Alarm function Refer to p 36 Alarm hold Refer to p 36 Function key Refer to p 37 Abbreviation Refer to p 38 Tour sequence Refer to p 39 Camera menu Refer to p 40 Password Refer to p 40 Designates the unit as a master or slave Determines the type of switcher to be connected to the unit Sets the Alarm Contact Output Terminal s operation Only valid when MASTE
21. 6 4 15 Alarm time Sets the interval between alarm input and alarm reset Note The Alarm Time can only be set when 1 EDGE has been selected in the Alarm signal setting This setting item is not displayed on the menu screen when 2 LEVEL has been selected Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select ALARM TIME and confirm the selection with the SET key The setting is displayed on Line 2 ALARM TIME 3 20SEC Step 3 Tilt the joystick to the left or right to select one of the following settings and confirm it with the SET key Setting contents 1 10SEC 10 seconds 6 2MIN 2 minutes 2 15SEC 15 seconds 7 3MIN 3 minutes 3 20SEC 20 seconds 8 4MIN 4 minutes 4 30SEC 30 seconds 9 5MIN 5 minutes 5 1MIN 1 minute 10 NO LIMIT no time limit Notes e If 10 NO LIMIT is selected the alarm can only be reset when the Alarm Reset key on the unit s top panel is pressed e This selection is set to 3 20SEC by the factory 35 6 4 16 Alarm function Sets the camera image monitor method to be used when an alarm signal is received Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select ALARM FUNCTION and confirm the selection with the SET key The setting will appear on Line 2 ALARM FUNCTION 1 SEQ Step 3 Tilt the joystick to the left or right to select either of the following settings a
22. 7 2 from the list shown below 1 TRACE 2 POSI Step 7 Press the SET key to confirm the operation setting for 2 The procedure returns to Step 3 and the settings are displayed on the LCD screen Step 8 To further set other channels repeat Steps 3 7 To return to the setting display press the Clear key HOME POS CH 7 1 TRACE 2 OFF Home position selector terminal operation settings Orients the camera in the direction of Position 1 as set at the camera Orients the camera in the direction of Position 2 as set at the camera Activates the Auto Pan function Activates the Auto Trace function 2 Activates the Preset Sequence function s 1 Automatically pans the camera pan tilt head 2 Automatically executes manual camera operations stored in memory 3 Automatically sequences camera positions in the order that the position numbers were selected Notes e Make sure to perform each camera setting when POS2 TRACE or P SEQ is selected The unit could malfunction if this setting is not correctly performed e This selection is set to POS1 by the factory 6 4 6 I O speed Sets each control terminal s transfer rate Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Press the Menu key to display the menu screen Tilt the joystick up or down to select I O SPEED then press the SET key to confirm the selection The screen for selecting the control terminal is d
23. CD screen selected SO ifr AUTO FOCUS The indicator remains lit while the Auto Focus function is in operation AF Auto focus operation is completed L 5 1 11 Selecting the camera position Example Step 1 Enter the camera position number with the numeric keypad el Step 2 Press the Position key POSITION LCD screen The camera image corresponding to the selected position will be displayed on the monitor 5 POSITION Note When the Trace function is used in the camera setting the selection of Position No 255 executes Auto Trace operations 5 2 Monitor Display Operation keys 16 segment split screen key Alarm hold key Alarm reset key Function key FUNCTION h g d GROUP D E F G a i Ey SELECT SEQUENCE 10 segment split screen key 9 segment split screen key 4 segment split screen key Sequential 4 segment split screen key CH MENU 1 z CH call key Sequential key Group selector key WIPER DEF AUX AUTO FREEZE POSITION CONTROL FULL oOo oO oOo oO oO PLLA Ld LJ Numeric keypad 1 4 7 Cc
24. G ae FUNCTION A B Cc D E F G H ADD onga D9 OOOVOOOD MO B ao i fr sca ENCE cli MENU Ke g 1 2 lis p LIL IL WIDE 4 5 6 7 8 9 C 0 SET REMOTE CONTROLLER C RM500 DDIAD O 8 DM B Notes Depending on the system configuration the operation of some keys may be disabled The corresponding keys are marked with the following indications 1 Does not function in systems using only with Combination cameras 2 Does not function in systems using the Smart Switcher 3 Functions only when connected to the Combination camera 4 Connect the DC power supply of 12 V over 150 mA to either input terminal Function keys A H A single depression of one of these keys displays the full screen image of the key s corresponding camera number and position number Each key can also be set to activate automatic operations panning tracing and sequential switching of the selected Combination camera Alarm reset key Al
25. R has been selected in the Option mode setting Sets the function to automatically return the camera to a specified Home position after operation completion Sets the Combination camera s standby status Sets the transfer rate of each control terminal Sets whether or not to sound a buzzer when an alarm is engaged Sets the screen to be displayed on the monitor immediately after the power is switched ON Sets the channel camera number to be displayed first when the power is switched ON ON when using the Sensor Alarm function ON when using the Combination camera s alarm contact input Checks the Combination camera connected to the camera control terminal for 30 seconds Sets the position number and direction in which the Combination camera will automatically face when an alarm signal is received from the camera Only valid when ON has been selected in the Camera alarm setting Sets the type of alarm activation signal Sets the time interval from alarm signal reception to reset Sets the monitor display method when an alarm signal is received Only valid when EDGE has been selected in the Alarm signal setting Sets the monitor display to be switched when an alarm signal is received Displays the corresponding preset camera image camera number and position number on the monitor Displays the corresponding preset camera image camera number and position number on the monitor when the abbreviated n
26. Screen key The images of camera numbers 1 8 Group 1 and 2 more images set with the Switcher will be displayed on the monitor Press the 10 Segment Split Screen key again or the Group Selector key The images of camera numbers 9 16 Group 2 and 2 more images set with the Switcher will be displayed on the monitor 9 segment split screen viewing Step 1 Step 2 Press the 9 Segment Split Screen key The images of camera numbers 1 9 Group 1 will be displayed on the monitor Press the 9 Segment Split Screen key again or the Group Selector key The images of camera numbers 10 16 Group 2 will be displayed on the monitor Camera number Camera name LCD screen 10 SEGMENT Monitor screen Group 1 Note Camera images can be freely selected for Screens XX and YY using the switcher or a Camera number or GROUP SELECT GROUP SELECT Monitor screen Group 2 LCD screen 9 SEGMENT Monitor screen Group 1 Monitor screen Group 2 17 4 segment split screen viewing Step 1 Press the 4 Segment Split Screen key EoD sergen The images of camera numbers 1 4 Group 1 4 SEGMENT will be displayed on the monitor Monitor screen Group 1
27. Za OA f OPERATING INSTRUCTIONS REMOTE CONTROLLER C RM500 ALARM FUNCTION RESET HOLD GROUP 6668 SEED ATD MM D E o o GSE G9 Gee CD BB SELECT sequence CH MENU WIPER DEF AUX AUTO FREEZE POSITION CONTROL FULL oo Oo Oo Oo LENS SPEED LOW HIGH ooo00 REMOTE CONTROLLER C RM500 Please follow the instructions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference TOA Corporation TABLE OF CONTENTS 1 2 3 SAFETY PRECAUTIONS iio coe itoedetatntn ati ae GENERAL DESCRIPTION assciccctescscscsgsssesset seuss tosthatovigtukcacl gene thapetauetgnantelliaaeht FUNCTIONS 2106 22ufu5 cain a Gin ane NOMENCIATURE AND FUNCTIONS OPERATION 5 1 Operating the Camera 5 1 1 Selecting cameras for operation cceeceeeeeeeeeeeeeeeeeesecaeeeeeeeseeeeeenaeeeeaes 5 1 2 Rotating the camera with the joystick ccc ceeeeceeeeeeeeeeeeeeeeeeeeeeeeeeaees 5
28. amera Note This setting can only be performed when 1 ON has been selected in the Camera alarm setting This setting item is not displayed on the menu screen when 2 OFF has been selected Different camera positions can be programmed into each of 8 camera alarm contact inputs It is also possible to make a camera contact output that has received an alarm signal by interlocking the contact output with the alarm Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Press the Menu key to display the menu screen Tilt the joystick up or down to select PRESET CAM ALARM and confirm the selection with the SET key The Camera Alarm Preset setting is displayed on Line 2 and the unit switches to Camera Number Entry Waiting mode Enter the camera number using the numeric keypad and confirm with the SET key The flashing cursor will move to the alarm number Tilt the joystick to the left or right to select the alarm number and confirm the selected alarm number with the SET key The flashing cursor will move to the preset position number Using the numeric keypad enter the number of the position to be displayed when the alarm contact is made and confirm the number with the SET key The flashing cursor will move to the rightmost position Tilt the joystick to the left or right to select either space or If is selected the camera s auxiliary contact output 2 can be set
29. arm indicator Resets the system s Alarm mode The indicator light flashes during Alarm operation Alarm hold key Hold indicator Places activated Alarm inputs on hold The indicator light flashes during Alarm Hold 4 16 segment split screen key Displays camera images in the 16 segment split screen format 10 segment split screen key 2 Displays camera images in the 10 segment split screen format Subsequent depressions of this key can toggle between two separate groups of 10 segment split screen displays 6 9 segment split screen key 2 Displays camera images in the 9 segment split screen format Subsequent depressions of this key can toggle between two separate groups of 9 segment split screen displays 10 11 12 13 14 15 16 17 4 segment split screen key Displays camera images in the 4 segment split screen format Subsequent depressions of this key can cycle through 4 separate groups of 4 segment split screen displays Sequential 4 segment split screen key Sequentially cycles through all connected camera outputs of up to 4 groups of cameras at a preset time interval Program sequencing and viewing intervals are set at the Smart Switcher when connected Group selector key 2 Switches on screen camera groups during 4 9 or 10 segment split screen display Sequence key Sequences all connected camera outputs to the full screen
30. camera number to reset the freeze display using the numeric keypad Step 2 Press the Freeze Screen key 14 FREEZE Ci FREEZE C Flashes L Freeze display indication Camera name LCD screen Monitor screen 10 segment split screen display FREEZE Note Two lower screens can be freely set using the switcher FREEZE FREEZE CI CI Example LJ gt Le S Q FREEZE FREEZE Are The freeze display will be reset LCD screen Monitor screen 10 segment split screen display LCD screen Monitor screen 10 segment split screen display FREEZE 5 2 3 Using the Function keys By simply pressing a Function key A H the camera image camera number and position number programmed into the key can be displayed on the monitor Refer to p 37 Function key programming Press a Function key A H The corresponding camera image camera number and position number is displayed on the full screen of the monitor FUNCTION A B Cc D E F G CONTROL H Lights LCD screen 5 2 4 Using the abbreviated numbers coon gt O V Display of the camera number programmed into the Function key By merely pressing the abbreviated number followed by the SET key the camera image camera number and position number programmed under t
31. ch ath aaa eedlss ete 25 61453 CONLACE eeraa E savectenbsance tent EO EEE EE T EEEE AEE A EEREN EKRE TERRE ERRESA 26 6 4 4 Automatic reset iseler ai neds eee teehee eee ds eden ted REEE 27 6 4 5 HOE POSHION gea ie eae E e EAEE beady eth any ES EE eyetaertansutdent TERESETA 28 6 4 6 VO speed irase eai aia ae a a a a aiid ane 29 047i BUZZER iiaii didai i aia e ives in ae eee ee i ee 30 64 8 ntal SGFEGIT a tae cizg tesbenagetceechcte cae a pees Saabs con faa aa a a ea aA aana S 30 6 4 9 Channel designation ssessesseessenssrresrrsesrrstintrtntttnstttnesrnnssrnssrnnnsrnsssrnnnnn 31 BA10 Sansor alarm orreina O A AA EE EA E O A N 32 6 4 11 Camera alarm soossesoosssnnoossnnestrnneeertnreeertnneeertnneeertnneeertnneeertnnneennnn nenene 32 6412 Camera CHECK sevaceseuccestecectutaaddesvvieaccdeces va adeacevaditescecenstedsctetaud Meawtvhdoestenwseue 33 6 4 13 Camera alarm preset cccceeseceeeeeeeseaeeeeeneeeceaeeeeeneeseeaeeseaaeeseeaeeeeaaeeninees 34 6 4 14 Alarm SIQMal sre Ta eee eae eE EE EEEE EAE AEE AE EAEE EERE 35 6 4 15 Alanm timMe Aiia a artian iai ada d eiaa aait 35 6 4 16 Alarm fUNCHON ieena ia aiie iii iaai idae ia aaa aa 36 6 417 Alarmi hold ann n nee na eae ae 36 6 4 18 Function key programming sssssessssssrrsssssrrsssrirrsssinnsssttnnnnstinnnnstennnnntnn n 37 6 4 19 Ab bbreviat OA a a a aae a a aa aaa aa aaa A raa aaa a EE a aai 38 6 4 20 TOU SEQUENCE ssasssssseesesrneeessrresrrrnnesennnnesetnnnnnnnnnnnnu
32. contact corresponding to the channel number camera number is made when each channel is selected for full screen display In the alarm state when an alarm signal is input the contact corresponding to the channel number is made Notes e When 10 OTHER has been selected in the Switchers settings only 1 SELECTION CHANNEL can be set e This selection is set to 2 ALARM by the factory 6 4 4 Automatic reset Enables the function that automatically resets the camera to a fixed position if the camera is not operated for a preset time interval Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select AUTO RETURN and confirm it with the SET key The setting will appear on Line 2 AUTO RETURN 1 0N Step 3 Tilt the joystick left or right to select either of the following settings and confirm it with the SET key Setting contents Confirming this setting displays the screen for setting the time interval before Automatic Reset occurs following camera operation AUTO RETURN 1 0N 10SEC Tilt the joystick left or right to select the reset interval 10 SEC 15 SEC 20 SEC 30 SEC 1 MIN 2 MIN 3 MIN 4 MIN and 5 MIN The selected time is confirmed with the SET key Note SEC stands for seconds and MIN for minutes Disables the Automatic Reset function Note This selection is set to 2 OFF by the factory 2 6 4 5 Home position Sets
33. e D sub 9 pin connector C RM500 Switcher control terminal Camera control terminal GND RS 232C Alarm output terminal WOOOOOOOo ae CEA S LC Fixed camera Shielded twisted pair cable p A P B Alarm I O Monitor output if Ccu Jp lt p a Corresponding to the fixed camera A 1 Se Camera control Alarm input 2 oo cable cable i 4 6 Corresponding to i the fixed camera B L ooe oo Nese 5 10 Sensor Sensor Combination camera 1 o 2 Camera control Alarm input Monitor TV 3 cable cable 4 i 4 6 5 l i 0 Eog cooo Neer 5 10 Sensor Combination camera ca The use of each camera s alarm input permits connection of 8 sensors for each camera Connect this cable only when 2 LEVEL is selected in the unit s Alarm signal setting Refer to p 35 Connect the C RM500 s alarm output corresponding to the Combination Camera address to the Multi Switcher s alarm input while leaving other output terminals not corresponding to any Camera address unconnected 45 46 7 4 Connection to the Smart Switcher s RS 232C Terminal e When connecting the camera s video output cable to the Multi Switcher match the Multi Switcher s camera input terminal number with the camera s address number
34. e Multi Switcher is connected Equipment Which Can Be Controlled with the C RM500 Shown below are equipment that can be controlled with the C RM500 Camera C CC501 C CC504 C CC551 and C CC554 Up to 31 cameras can be connected to the unit s Camera control terminal and controlled The use of the C IF500 Interface Unit will increase the number to up to 64 cameras when the C SS8 switcher is in use Note that the cameras cannot be controlled if their number is greater than the number of inputs of a connected switcher Switcher C MS90D C MS90S C MS160D C MS160S and C SS8 Only one switcher can be connected for remote camera control However as to the C SS8 1 master designated unit and up to 7 slave designated units can be connected to remotely control the cameras About the Camera Control Terminal The Camera control terminal is used to connect the C CC501 C CC504 C CC551 or C CC554 Combination Camera or the C IF500 Interface Unit Up to 31 pieces of equipment can be connected to the terminal About the Descriptions in This Manual e The explanations in this manual assume that the C RM500 Remote Controller is connected to a C MS160D S or C MS90D S Multi Switcher and the C SS8 Smart Switcher e Camera number Refers to the camera input terminal number connected to the switcher e Position number Combination camera orientation can be programmed for No 1 255 4 NOMENCLATURE AND FUNCTIONS Top D ALARM RESET HOLD
35. e The C CC551 and C CC554 Combination cameras permit settings of up to 255 camera positions camera orientation and the C CC501 and C CC504 permit settings of up to 64 positions All are equipped with 8 alarm input terminals To expand the alarm input connect the C AL80 Alarm Input Unit to the C RM500 Remote Controller Note Do not use the Smart Switcher s Alarm input terminal as the unit could malfunction e To switch the display to the fixed camera output when an alarm signal is received connect the Alarm Input Unit to the unit Also in the unit s abbreviated number setting set the position number of the fixed camera to be switched to when an alarm signal is received to 0 e The Alarm Input Unit activates the alarm for the abbreviated number For details refer to the section Abbreviation on p 38 in this manual and the instruction manual included with the Alarm Input Unit A C RM500 Camera control terminal Switcher control terminal Alarm input terminal GND RS 232C RS 232C PalPolojo o olojojolo at e qene kJ RS 232C reverse cable Female D sub 9 pin connector to Female D sub 9 pin connector i Fixed camera gt S Shielded twisted pair cable RS 232C reverse cable Female D sub 9 pin connector to Female D sub 9 pin connector Smart switcher P op O O Hi if ih ae OW OOO VAQO RS 232C
36. een display is set for OFF in the Multi Switcher settings 6 9 INPUT B 2 Select this setting when the 9 channels Multi Switcher is connected to the switcher control terminal RS 232C and Camera 9 s 4 segment split screen display is set for ON in the Multi Switcher settings 7 SMART Select this setting when a Smart Switcher is connected to the switcher control terminal RS 232C Confirming this setting will cause the unit to wait for the entry of the number of connected Smart Switchers SWITCHER 7 SMART 1 Enter the number of Smart Switchers connected to the system If the number has already been set the set number is displayed Confirm the number of switchers with the SET key Note Up to 8 Smart Switchers can be connected Be sure to enter the correct number If the wrong number is entered such symptoms will occur that unconnected cameras are selected or connected cameras cannot be selected 8 OTHER 16 2 Select this setting when the system includes a switcher other than Multi Switcher or Smart Switcher and the number of control channels is 16 or less 9 OTHER 16 gt 64 7 Select this setting when the system includes a switcher other than Multi Switcher or Smart Switcher and the number of control channels is between 17 and 64 10 OTHER Test mode 1 Power synchronization cannot be chosen by setup menu of the camera in this setting 2 Camera alarm is unreceivable in this setting Note The switch
37. enu screen and performs various Combination camera settings such as the storage of preset camera positions For detailed operations and settings of the camera menu refer to the instruction manual included with the camera Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select CAMERA MENU and confirm the selection with the SET key The unit will wait for entry of the camera number that starts up the menu CAMERA MENU CH Step 3 Enter the camera number with the numeric keypad and confirm the entered number with the SET key The selected camera menu appears on the monitor Pressing the Menu key again while the menu is being displayed on the monitor will turn off the display returning the display to the camera number entry screen Step 4 Repeat Steps 2 and 3 to continue to set other camera numbers Press the Clear key to return to the setting item display 6 4 22 Password Sets the password required when opening the menu Step 1 Press the Menu key while holding down the Alarm Reset key The password setting screen will appear PASSWORD REE Step 2 Enter the password 4 digits with the numeric keypad and confirm the password with the SET key The display will return to the normal screen 7 CONNECTIONS Note To eliminate noise be sure to connect the shield of a shielded twisted pair cable to be used for connection between control terminals for control to the GND termina
38. er etc Clear key C Used to correct entry errors Also turns off the buzzer when sounded by an activated alarm SET key Used in conjunction with the numeric keypad to program the camera number or position number Also if pressed after entering the set abbreviated number with the numeric key the camera image corresponding to that number can be displayed on the monitor Wiper key 3 Remotely controls the outdoor use Combination camera s wiper This key can only be used while the Control indicator is on Defroster key Indicator Remotely controls the outdoor use Combination camera s defroster This key can only be used while the Control indicator is on Auxiliary contact key Indicator Controls makes or breaks the Combination camera s Auxiliary Contact Output 1 The indicator is on when auxiliary contact is at make and off when the contact is at break This key can only be used when the Control indicator is on Auto key Indicator 3 Enables or disables the Combination camera s automatic functions Auto Pan Auto Trace and Preset Sequence The Auto key can only be used when the Control indicator is on e Auto Pan Automatically pans a camera pan tilt head e Auto Trace Automatically executes manual camera operations stored in memory e Preset Sequence Automatically sequences camera positions in the order of preset position numbers Auto focus key Indicator Enables the Combination camera s A
39. er attempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds If it is malfunctioning no image appears e To prevent a fire or electric shock never open nor remove the unit case as there are high voltage components inside the unit Refer all servicing to your nearest TOA dealer e Do not touch a power plug during thunder and lightning as this may result in electric shock e Do not place cups bowls or other containers of liquid or metallic objects on top of the unit If they accidentally spill into the unit this may cause a fire or electric shock CAUTION Indicates a potentially hazardous situation which if mishandled could L i result in moderate or minor personal injury and or property damage e Never plug in nor remove the power supply plug with wet hands as doing so may cause electric shock e When unplugging the power supply cord be sure to grasp the power supply plug never pull on the cord itself Operating the unit with a damaged power supply cord may cause a fire or electric shock e When moving the unit be sure to remove its power supply cord from the wall outlet Moving the unit with the power cord connected to
40. er type is set to 4 16 INPUT 2 by the factory 6 4 3 Contact Sets the alarm contact output terminal s operation Note Contacts can only be set when MASTER has been selected in the Operation mode setting This setting item is not displayed on the menu screen if SLAVE has been selected Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select CONTACT and confirm it with the SET key The setting content will appear on Line 2 CONTACT 1 SELECT CH Step 3 Tilt the joystick left or right to select one of the following setting contents and confirm it with the SET key Setting contents 1 SELECTION CHANNEL Makes the contact corresponding to the channel number camera number when each channel is selected for full screen display Also if the connection of a switcher with 16 or more input channels has been set the channel number selected for full screen display is converted into binary data and contacts 1 16 are assigned bits 0 15 2 ALARM Makes the contact corresponding to the alarm activated channel number camera number when the number of connected switcher inputs is 16 or less and there is an alarm signal input to each channel Also if 16 or more inputs are set the last channel to receive an alarm signal is converted into binary data and contacts 1 16 are assigned bits 0 15 In the normal state no contacts are enabled In the normal state the
41. erformed when the Control indicator is on Operating keys Auto key Auxiliary key Defroster key Wiper key Auto focus key Position key Control key Full screen key FREEZE oO jj T LENS SPEED LOW HIGH 0000 Zoom key Focus key 5 1 1 Selecting cameras for operation Lens speed key Joystick REMOTE CONTROLLER C RM500 Numeric keypad Cameras to be manually controlled can be selected during full screen or multi segment screen display Refer to p 10 12 for individual camera operations Step 1 Step 2 2 1 2 2 Note Using the numerical keypad press the desired camera number Press either the Full Screen key or Control key Operation in full screen display format Press the Full Screen key The Control indicator will light permitting operation of the designated camera Operation in multi screen display format Press the Control key during multi screen display The Control indicator will light permitting operation of the designated camera Both XX and YY camera images can be freely set using the switch Example nhs FULL J CONTROL LCD screen Lights
42. function When a Combination camera is connected its zoom lens can be activated using the Zoom key Press the Zoom Telescope or Wide Angle key while oie LED Screeri the camera is selected Zooming continues as long as the key is pressed MANUAL WIDE 5 1 8 Activating the focus function When a Combination camera is connected its image can be focused using the Focus key Press the Focus Far or Near key while the camera is FOCUS teu selected Focusing continues as long as the key is FAR pls pressed MANUAL NEA 11 12 5 1 9 Changing the lens speed The speed of lens movement when the Zoom or Focus key is pressed can be adjusted in 4 steps of operation 1 Very slow 2 Slow 3 Moderately fast 4 Fast Step 1 Press the Lens Speed key The speed indicator number increases by one each time the Speed key is depressed to indicate that the lens speed has been increased by one level Lens operating speed returns to Very slow when the Speed key is pressed while in Fast mode Step 2 Repeat Step 1 until the desired speed is displayed LENS SPEED LENS SPEED LENS SPEED LENS SPEED LOW HIGH LOW HIGH LOW HIGH LOW HIGH Lights OO Bauu 20 Do0 A gt QP n 5 1 10 Activating the auto focus function When a Combination camera is connected the Auto Focus function can be activated with a press of the Auto Focus key AF AF Press the Auto Focus key while the camera is lightis L
43. gray paint Sides Rubber Dimensions 326 w x 62 h x 185 2 d mm Weight 1 8 kg AC adapter excluded Applies to the system where the unit and Combination camera are connected in a matched pair Represents the total of connected cable distances if multiple Combination cameras or Interface units are connected in the system when the CPEV S cable thicker than 0 65 mm in diameter is used Note The design and specifications are subject to change without notice for improvement Accessories D sub connector 9 pins male D sub connector 25 pins male C RM500 complies with Part 15 of the FCC Rules Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications Any modifications made to this device that are not approved by TOA Corporation may void the authority granted to the user by the FCC to operate thi
44. he abbreviated number can be displayed on the monitor Refer to p 38 Abbreviation Step 1 Enter the abbreviated number with the numeric keypad Step 2 Press the SET key The programmed camera position s image will be displayed on the full screen Simultaneously the Control indicator lights permitting camera operations with the joystick CONTROL 9 4 Lights LCD screen a gt 0 V F Display of the camera number programmed under the abbreviated number 15 16 5 2 5 Viewing full screen displays Step 1 Step 2 Enter the camera number to be displayed on the full screen using the numeric keypad Press the Full Screen key The designated camera image will be displayed on the full screen Simultaneously the Control indicator lights permitting camera operations with the joystick Example gt vU FULL CONTROL 4 Lights Eiin LCD screen 13 CHANNEL Camera number displayed in full screen format 5 2 6 Viewing multi screen displays only active when the Multi Switcher is connected 16 segment split screen viewing Press the 16 Segment Split Screen key All connected camera images will be displayed on the monitor amm a DIIN D10 u09 LCD screen 16 SEGMENT Monitor screen Camera number 10 segment split screen viewing Step 1 Step 2 Press the 10 Segment Split
45. hen one of the settings 1 FULL 4 4 SEG 5 9 SEG or 6 10 SEG has been selected in the Initial screen setting The Channel Designation item is not displayed on the menu screen when another setting has been selected Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select INITIAL CHANNEL then confirm the selection with the SET key The setting corresponding to the Initial Screen setting is displayed on Line 2 Step 3 Using the joystick and numeric keypad select the setting depending on the Initial screen setting and confirm the selected setting with the SET key Refer to the table shown below Setting contents Initial screen Setting Setting 1 FULL Enter the channel to be designated with the numeric keypad and confirm full screen the setting with the SET key INITIAL CHANNEL CHANNEL123 Note This selection is set to 1 by the factory 4 4 SEG Tilt the joystick to the left or right to select 1 4 5 8 9 12 or 13 4 segment split screen 16 and confirm with the SET key display INITIAL CHANNEL Note This selection is set to 1 4 by the factory 5 9 SEG Tilt the joystick to the left or right to select 1 9 or 10 16 and confirm 9 segment split screen with the SET key display INITIAL CHANNEL Note This selection is set to 1 9 by the factory 6 10 SEG Tilt the joystick to the left or right
46. isplayed Tilt the joystick left or right to select the control terminal Select the control terminal from CAMERA SWCHER switcher REMOTE Remote Control Unit and ALARM Press the SET key to confirm the selected control terminal The transfer rate is shown on Line 2 In this event the current setting is displayed Tilt the joystick left or right to select the transfer rate The transfer rate can be selected from 2400 4800 9600 19200 and 38400 Note Set the same transfer rate as those of equipment connected to each control terminal Control Terminal Factory Setting 38400 bps 19200 bps Camera Switcher Remote control unit Alarm 19200 bps 38400 bps Press the SET key to confirm the set transfer rate The procedure returns to Step 3 and the settings are displayed on the LCD screen To further set other control terminals repeat Steps 3 6 To return to the display of the setting item press the Clear key 1 0 SPEED p 1 0 SPEED CAMERA UP 1 0 SPEED REMOTE i 1 0 SPEED REMOTE 38400 UP 1 0 SPEED REMOTE 19200 29 30 6 4 7 Buzzer Sets whether or not to sound the buzzer when an alarm signal is received Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select BUZZER then confirm the selection with the SET key The setting is displayed on Line 2 BUZZER 1 0N Step 3 Tilt the jo
47. l Equipment Which Can Be Controlled with the C RM500 Shown below are equipment that can be controlled with the C RM500 Camera C CC501 C CC504 C CC551 and C CC554 Up to 31 cameras can be connected to the unit s Camera control terminal and controlled The use of the C IF500 Interface Unit will increase the number to up to 64 cameras when the C SS8 switcher is in use Note that the cameras cannot be controlled if their number is greater than the number of inputs of a connected switcher Switcher C MS90D C MS90S C MS160D C MS160S and C SS8 Only one switcher can be connected for remote camera control However as to the C SS8 1 master designated unit and up to 7 slave designated units can be connected to remotely control the cameras About the Camera Control Terminal The Camera control terminal is used to connect the C CC501 C CC504 C CC551 or C CC554 Combination Camera or the C IF500 Interface Unit Up to 31 pieces of equipment can be connected to the terminal 7 1 System Examples Example 1 Combination camera Monitor TV 41 Example 2 Combination camera Combination camera Example 3 Combination camera Combination camera 42 Multi switcher gooo0o00000 DooooooD
48. nd confirm it with the SET key Setting contents 1 SEQ Sequence Sequences the alarm activated camera outputs to the monitor in full screen display in the order of alarm signal reception 2 LAST The output of the camera corresponding to the last received alarm signal is displayed on the monitor in full screen display Notes e Only the selection 2 LAST can be set when a Smart Switcher is connected to the system e This selection is set to 1 SEQ by the factory 6 4 17 Alarm hold Always places on hold alarm signals to the surveillance camera system Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select ALARM HOLD and confirm the selection with the SET key The setting is displayed on Line 2 ALARM HOLD 1 KEY Step 3 Tilt the joystick to the left or right to select either of the following settings and confirm it with the SET key Setting contents 1 KEY Permits the alarm to be held or reset using the unit s front panel mounted keys Refer to p 20 2 ALWAYS Always places the alarm on hold when an alarm signal is input Select this setting when it is not desirable to have the screen automatically switched every time an alarm signal is received Note This selection is set to 1 KEY by the factory 6 4 18 Function key programming By simply pressing the function key the camera image camera number and position number can be displayed on the moni
49. ntnnenntnnnenunnnnnnnnannnnannn nne 39 624 21 Camera MONI erari ri Aa cnc se deans VOEE LA sceiasstedactetaie dectunnd deiteawsede 40 6 4 DO PASSWOIG Aat ttre Ai silk tac e eit aa a aa aa aeaa a ee ee A i oh 40 7 CONNECTIONS 71 System Examples si tii ceva cence evita eeative ide nities 41 7 2 Connection to Combination Cameras ceesscceseeesteceeeeeneeeeeeentaeeesesesaeeeeeseaaas 43 7 3 Connection to the Multi Switcher s RS 232C Terminal s es 44 7 4 Connection to the Smart Switcher s RS 232C Terminal cccccccseeeeeseeeeees 46 7 5 Connection When Controlling the System from 2 Locations ccseeeeeeeee 48 7 6 Alarm Output Control Input Terminal Connections FO WsaP IM AUMCUONS a2 est carts seca eet i at Gs Lee das Se oes el art ce toes 49 7 6 2 Assembling D sub connectors Onto cables 0 cceceeeeeeeeeeeeeeeeeeeeeeeeeeeees 50 Bs SPECIFICATIONS cnnan ee Aiea aera asada Ace oat he 51 PACCESSOMIOS EAE EEEE O E seebsnard E EE ct Deets levhs oi E EAT 51 Underwriters Laboratories Inc UL has not tested the performance or reliability of the security aspects of this product UL has only tested for fire shock or casualties as outlined in UL s Standard s for Safety UL Certification does not cover the performance or reliability of the security hardware and security operating software UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY
50. number with the SET key Enter a number from 1 to 128 The flashing cursor moves to the camera number Enter the camera number with the numeric keypad and confirm the number with the SET key Enter a number from 1 to 999 The flashing cursor moves to the position number Enter the position number with the numeric keypad and confirm the number with the SET key Enter a number from 1 to 255 Tip Entering 0 will switch the screen to full screen display and does not execute position playback The flashing cursor moves to the rightmost viewing interval selection indication on Line 2 Tilt the joystick to the left or right to select the viewing interval 83SEC 10SEC 15SEC 20SEC 80SEC or 1MIN SEC seconds MIN minutes Press the SET key to confirm the set interval The procedure returns to Step 4 Repeat Steps 4 8 to continue setting the playback numbers Press the Clear key to return to the setting item display Deleting Settings After pressing the Alarm Reset key press the SET key TOUR SEQ NO Set by the factory TOUR SEQ YES Example 9 TOUR SEQ 1 Cxxx Pxex T1I0SEC Example UP No LEFT Q or DOWN TOUR SEQ 1 Cx x Pxkx T10S9EC Example l J TOUR SEQ C123 Pxx T10SEC UP TOUR SEQ 1 C123 P200 T10SEC 39 40 6 4 21 Camera menu Calls up the camera s m
51. rol terminal RS 485 Connects to the Combination camera 31 Switcher control terminal RS 485 Connects to the Multi Switcher s dedicated remote control terminal and controls the Switcher s screen display 32 Slave unit remote control terminal Connects to another C RM500 Remote Controller to be designated as a slave unit for remote control from different locations 33 Power input terminal DC IN 12 V 4 Used to supply power from a source other than the supplied AC adapter 34 Ground Terminal GND Please ground by the cable that attached the supplied clamp filter 1turn GND GND Terminal clamp filter Please attach a clamp filter to the nearest possible position of this controller SWITCHER ALARM IN ALARM OUT amp DC IN 12V eee 35 Switcher control terminal RS 232C Connects to the RS 232C I O terminal of the Multi Switcher and Smart Switcher to control these switchers 36 Alarm input terminal RS 232C Connects to an alarm input unit to receive alarm signals This terminal is also a serial I O terminal that functions as an interface with external systems 37 Alarm output Control input terminal Makes contact corresponding to the alarm activated channel camera number 38 AC adapter power input terminal DC IN 12 V 4 Insert the DC plug of the dedicated AC adapter into this terminal 39 Rating label 5 OPERATION 5 1 Operating the Camera The following camera operations can be p
52. round terminal even when only one of the alarm input terminals receives an alarm signal The alarm output terminal is the NPN open collector output Operating current Maximum 20 V 20 mA Alarm Input Terminal Pin No 23 Shorting this terminal with the ground terminal when OTHER16 OTHER16 64 or OTHER has been selected in the SWITCHER setting will sound a buzzer and cause the Alarm Reset indicator to flash while it is shorted Refer to p 25 Switchers Open voltage 5 V DC short circuit current Maximum 5 mA Home Position Selection Input Terminal Pin No 24 When Auto Return is performed while this terminal is being shorted to the ground terminal the camera s operation follows the setting made for 2 in the Home position setting Refer to p 28 Home position Open voltage 5 V DC short circuit current Maximum 5 mA Auxiliary Input Pin No 25 Leave this input unconnected Open voltage 5 V DC short circuit current Maximum 5 mA 49 7 6 2 Assembling D sub connectors onto cables Prepare the D sub connector supplied with the Unit Shield cover B Step 1 Solder the cable wires to the corresponding connector pins to be used Step 2 Bend back the braided shield and wrap with the copper foil tape Step 3 Cover the connector with shield cover A Step 4 Align shield cover B with shield cover A and press till its hook fits into place Step 5 Tighten the nut Step 6 Install the lock screw
53. s Step 7 Mount the ring stopper to the screws 8 SPECIFICATIONS Power Source 12 V DC AC adapter Current Consumption 150 mA Slave Remote Controller RS 485 screwless connector Camera Control RS 485 screwless connector Switcher Control RS 485 screwless connector RS 232C D sub connector 9 pins male Alarm Input RS 232C D sub connector 9 pins male Alarm Output Control Input Alarm output 16 channels NPN open collector output withstand voltage 30 V DC control current 20 mA 1 channel no voltage make contact input open coltage 5 V DC short circuit current 5 mA max Home position selection input 1 channel no voltage make contact input open voltage 5 V DC short circuit current 5 mA max D sub connector 25 pins female Alarm input Display LED indication of control status alarm status alarm hold status still picture status defroster auxiliary setting auto panning and lens speed LCD indication of key entry confirmation Alarm Signal Continuous alarm tone can be turned on and off Number of Unit Connections Up to 2 one to be set for MASTER unit another for SLAVE unit Maximum Cable Distance 1 2 km between the Remote controller and the Combination cameras Operating Temperature 0 to 50 C Operating Humidity Under 90 no due condensation produced Finish Panel Surface treated steel plate sand
54. s equipment A Printed in J 4E TOA Corporation AE
55. ted to the Multi Switcher full screen 4 segment sequential 4 segment 9 segment 10 segment or 16 segment split screen and sequential full screen Manual Operation Controls the Combination camera s zoom focus pan and tilt functions Camera Position Selection Controls the Combination camera s orientation and displays the camera image on the monitor in the selected orientation Function Key Programming Camera numbers or camera number position combinations can be programmed into the function keys A H Pressing the function key displays the camera image on the full screen If position numbers have been set images of the selected camera orientation can be displayed Abbreviated Number Display Permits camera numbers or camera number position combinations to be programmed for numbers 1 512 Entering the programmed number followed by the SET key displays the corresponding camera number on the full screen and the image of selected camera orientation if the position number has been set Alarm Function Controls the display in synchronization with alarm signals received from a camera When an alarm signal is detected the image of the corresponding camera takes display precedence The C RM500 Controller also features an Alarm Hold function that temporarily disables channel camera number switching in response to an alarm signal This prevents the display from being forcibly switched to an alerted camera during close inspection when th
56. the Clear key to return to the setting item display Automatic operation settings After performing the settings in Steps 1 3 above tilt the joystick up FUNCTION KEY A or down to select one of the following settings then press the SET key AUTO PAN to confirm it AUTO PAN Continues panning between 2 points set on the camera menu AUTO TRACE Repeats manual operations set on the camera menu PRESET SEQUENCE Plays back the positions stored in the camera in setting order AUX2 auxiliary2 Makes or breaks the Combination camera s auxiliary contact output 2 Deleting settings After pressing the Alarm Reset key press the SET key 37 38 6 4 19 Abbreviation By merely pressing the preprogrammed abbreviated number numeric keypad entry and SET key the camera image camera number and position number can be displayed on the monitor Up to 512 camera numbers or 512 camera position numbers can be set The abbreviated number provides the same function as the function key Step 1 Step 2 Step 3 Step 4 Step 5 Press the Menu key to display the menu screen Tilt the joystick up or down to select ABBREVIATION and confirm the selection with the SET key The settings are displayed on Line 2 and the unit switched to Function Key Entry Waiting mode Note that when the camera number or the position number is not programmed in advance the x x indication is displayed in place of the number
57. the Combination camera to standby status when not being operated Note When 10 OTHER is selected in the Switchers setting set the operation common to all channels In this event the screen described in Step 2 below and the rightmost CH indication on the LCD screen are not shown Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select HOME POS then confirm it with the SET key The channel camera number input screen for the Home Position setting will appear Step 3 Enter the channel number with the numeric keypad and confirm the entry with the SET key The operation setting is displayed on the bottom line and the cursor moves to the position P left The No 1 on the left HOME POS CH 7 shows the operation setting when the Home Position selection 1 POS1 2 POSI input terminal in the unit s rear panel mounted Alarm output control input terminal is broken Similarly the No 2 on the right shows the operation setting when the Home Position terminal is made Refer to p 49 Alarm Output Control Input Terminal Connections HOME POS CH 7 Step 4 Tilt the joystick left or right to select the operation settings for 1 TRACE 2 POSI 1 from the list shown below Step 5 Press the SET key to confirm the operation setting for 1 The cursor moves to P right Step 6 Tilt the joystick left or right to select the operation settings for HOME POS CH
58. to be made when the camera alarm signal is received Press the SET key to confirm the settings The procedure returns to Step 3 and the settings are displayed on the LCD screen Repeat Steps 3 7 to continue setting the Camera Alarm Preset Press the Clear key to return to the setting item display PRESET CAM ALARM PRESET CAM ALARM CAM1 ALi 123 Example PRESET CAM ALARM CAM7 AL1 123 PRESET CAM ALARM CAM7 AL5 123 PRESET CAM ALARM CAM7 AL5 255 UP PRESET CAM ALARM CAM7 AL5 255 6 4 14 Alarm signal Sets continuous alarm operations Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select ALARM SIGNAL and confirm the selection with the SET key The setting is displayed on Line 2 ALARM SIGNAL 1 EDGE Step 3 Tilt the joystick to the left or right to select either of the following settings and confirm it with the SET key Setting contents 1 EDGE Terminates alarm operations when the time interval set in the Alarm time setting next item passes or when an alarm reset signal is received 2 LEVEL Terminates alarm operations when the alarm input terminal receives alarm end data Also if 1 ON has been selected in the Camera alarm setting alarm operation will stop when all alarm signals from the camera change from make to break data Note This selection is set to 1 EDGE by the factory
59. to select 1 8 or 9 16 and confirm 10 segment split screen with the SET key display INITIAL CHANNEL Notes e Make sure that this setting is the same as that of the connected switcher e This selection is set to 1 8 by the factory 31 32 6 4 10 Sensor alarm Select 1 ON to use the Sensor Alarm function Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select SENSOR ALARM and confirm the selection with the SET key The setting is displayed on Line 2 SENSOR ALARM 1 0N Step 3 Tilt the joystick to the left or right to select either of the following settings and confirm it with the SET key Setting contents Uses Sensor Alarm Does not use Sensor Alarm Note This selection is set to 1 ON by the factory 6 4 11 Camera alarm Select 1 ON to use the Combination camera s alarm contact input Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select CAMERA ALARM and confirm the selection with the SET key The setting is displayed on Line 2 CAMERA ALARM 1 0N Step 3 Tilt the joystick to the left or right to select either of the following settings and confirm it with the SET key Setting contents Uses the Combination camera s alarm contact input Does not use the Combination camera s alarm contact input Notes e When operating the alarm by setting Camera alarm to 2
60. tor It is also possible to control alarm contact switching and instruct the camera to perform multiple automatic operations TEA key Step 1 Press the Menu key to display the menu screen FUNCTION KEY CAM e POS Step 2 Tilt the joystick up or down to select FUNCTION KEY and confirm the selection with the SET key The settings is displayed on Line 2 and the unit switches to Function Key Entry Waiting mode Note that when the camera number or the position number is not programmed in advance the x x FUNCTION KEY indication is displayed in place of the number CAM POS Step 3 Tilt the joystick to the left or right to select the desired function key and confirm the setting with the SET key The flashing cursor moves to the camera number L Position No Camera No Step 4 Enter the camera number using the numeric keypad and confirm it with the SET key Enter a number from 1 to 999 The flashing cursor moves to the position number Step 5 Enter the position number with the numeric keypad Enter a number from 1 to 255 Tip FUNCTION KEY Entering 0 will switch the screen to full screen CAM15 POS x display and will not execute position playback Step 6 Press the SET key to confirm the entered position number The procedure returns to Step 3 and the set contents are displayed on the LCD screen Step 7 Repeat Steps 3 6 to continue to set other Function keys Press
61. ts setting items when Returns the mode to the Confirms the setting items and tilted up and down and setting item selection without contents setting contents when tilted confirming or changing the left and right setting contents LCD screen display Setting item OPERATION MODE 1 MASTER Setting content 6 3 Basic Setting Operations This section shows basic operating procedures for each setting item Note however that the password setting differs from those explained here Refer to p 40 for the password setting procedure MENU Step 1 Press the Menu key with a pointed object a ES PASSWORD YX TEE When the password has been set The password entry screen is displayed 1 1 Enter the password 4 digits using the numeric keypad Example PRR gt E G a W D 1234 1 2 Press the SET key If the password is correct the menu screen appears OPERATION MODE a When the password has not been set OPERATION MODE The menu screen appears Example UP Step 2 Tilt the joystick up or down to select the setting AUTO RETURN item LEFT IGHT o gt Step 3 Press the SET key to confirm the setting item The current setting contents if not set the factory predetermined setting contents are displayed at the lower part of the LCD screen SET gt AU A RE DURN In this event one character 1 of the setting O contents flashes The flashing character Flashes differs depending on the content
62. umber entered with the numeric keypad is entered followed by the SET key Sequentially displays two or more camera outputs on full screen in order of reproduction 1 128 at preset time interval seconds Calls up the camera s built in menu screen permitting various Combination camera settings such as present position Sets the password required to open the menu Can be set when SLAVE has been selected in the Operation mode setting In this event other items are not displayed on the menu screen 21 22 6 2 Operating Keys and Display Screen Keys to be used in setting operations Alarm Reset key LCD screen Used for password setting Displays the setting items and their contents Menu key Pressing this key calls up the menu display on the LCD screen eee ATS ee The menu display returns to the SS E a a normal screen if the key is pressed again during setting except during Camera menu LENS SPEED and Password settings LOW HIGH 0000 Refer to p 40 REMOTE CONTROLLER C RM500 Numeric keypad Used for entering numbers Joystick Clear key SET key Selec
63. uto Focus function This key can only be used when the Control indicator is on Freeze screen key Indicator Freezes camera images However sequential displays cannot be made still The indicator flashes when there is a freeze image on the screen 27 Position key Orients the Combination camera toward the set direction The Position key can only be used when the Control indicator is on Pressing the Position key without designating the position number orients the camera toward the direction programmed under Position No 1 Home position 28 Control key Indicator Used to designate the camera to be manually Rear GD GD 626934 9 controlled during a multi screen display This key cannot be used during a full screen or sequential display Also nothing is operated even if this key is pressed without designating the channel number The indicator lights when the camera is controllable 29 Full screen key Displays the designated camera output on the full screen This key cannot be used unless the camera number is entered 000000 000000 00000000000000 GND GND GND GNDGND LY w w UJ CAMERA SWITCHER REMOTE DC IN 1 mMm Im m M model C RM500 120 12V TZ 150mA Class2 Ga Toac aa orporation d REMOTE CONTROLLER m IT MADE IN JAPAN 30 Camera cont
64. ystick left or right to select either of the following settings and confirm it with the SET key Setting contents Sounds a buzzer when alarm is activated Sounds no buzzer when alarm is activated Note This selection is set to 1 ON by the factory 6 4 8 Initial screen Sets the screen to be displayed immediately after the power is turned on Step 1 Press the Menu key to display the menu screen Step 2 Tilt the joystick up or down to select INITIAL SCREEN then confirm the selection with the SET key The setting will appear on Line 2 INITIAL SCREEN 1 FULL Step 3 Tilt the joystick left or right to select one of the following settings and confirm it with the SET key Note The settings differ depending on the type of switcher connected to the system Setting contents Switcher Type Setting Multi Switcher FULL full screen SEQUENCE 4 SEG SEQ sequential 4 segment split screen display 4 SEG 4 segment split screen display 9 SEG 10 SEG 16 SEG Notes e Make sure that the selected setting is the same as that for the connected switcher e This selection is set to 3 4 SEGMENT SEQ by the factory Smart Switcher 1 FULL 2 SEQUENCE Note This selection is set to SEQUENCE by the factory Other switchers 1 FULL 6 4 9 Channel designation Sets the first channel camera number to be displayed after the power is turned ON Note This channel setting can only be performed w