Home
Thermador VTI610D User's Manual
Contents
1. A Attach the inner wall fan inside the building only but not in living rooms A When attaching the inner wall fan ensure that it is accessible for maintenance and repairs A The plug and socket connections of the electric cables must be located inside the building according to local code A Do not reduce the 6 diameter of the pipes connected to the extractor hood Step 2 PREPARING THE WALL A The wall must be flat and perpendicular A Ensure that the wall is capable of providing a firm hold for mounting screws and plugs Weight in kg 8 8 We reserve the right to construction changes within the context of technical development PAGE 2 INSTALLATION 1 Hold the fan on the wall Note the direction of the air conduction 2 Mark the 4 mounting boreholes A At least one screw must be installed through a stud A The wall plugs must be suitable for the brickwork 3 Drill the 4 x mounting boreholes Insert wall plugs and screw the fan to the wall 4 Connect the pipe from the fan to the extractor hood and feed to the outside 5 Connect the fan to the extractor hood with an extension cable if required Use the added connector Use the wire diagramm for connecting The additional cover on the plug must always be attached and closed for safety reasons Not needed wires must be isolated capped with wire nuts and stored in a safe position PAGE 3 WIRE DIAGRAMM speed 1 s
2. appareils de chauffage au gaz au fuel ou au charbon les chauffe eau instantan s ou les chaudi res eau chau de veillez imp rativement ce que l apport d air frais soit suffisant pour assurer la combustion ad quate du br leur Un fonctionnement sans risque est possible si la sous pression dans la pi ce o le br leur est install ne d pas se pas 4 Pa 0 04 mbar On peut y parvient en acheminant l air requis pour la com bustion travers des ouvertures non obturables am na g es par exemple dans les portes ou les fen tres et en association avec des ventouses d admission d vacuation de l air fix es au mur o gr ce d autres mesures techni ques telles qu un verrouillage r ciproque Si l admission d air est mauvaise il existe un risque d intoxication par les gaz d gag s lors de la combus tion qui sont r achemin s dans la pi ce Une ventouse d admission ou d vacuation d air fix e au mur ne constitue pas elle seule une garantie que la valeur limite ne sera pas d pass e Remarque lors de l valuation de l exigence globale tou jours tenir compte de l ensemble des moyens d a ration du logement Cette r gle ne s applique pas l utilisation d appareils de cuisson comme les tables de cuisson et les cuisini res A Le ventilateur doit tre install au moins 78 Va po de la hotte aspirante A Installez le ventilateur de paroi interne uniquement a l int rieur du b timent sauf da
3. de cableado para realizar la conexi n Por motivos de seguridad la tapa adicional sobre el enchufe siempre debe estar colocada y cerrada Los cables que no sean necesarios deben aislarse taparse con una tuerca para cable y almacenarse en una posici n segura P GINA 3 DIAGRAMA DE CABLEADO velocidad 1 rojo velocidad 2 azul velocidad 3 naranja velocidad 4 N PE marron ns ER ES ST EN blanco gt verde amarillo p naranja blanco verde amarillo azul marr n L gt rojo N verde amarillo marr n Thermador An American Icon 5551 McFadden Avenue Huntington Beach CA 92649 800 735 4328 www thermador com 9000180879 10013 RevB 10 06 BSH Home Appliances Corporation Litho in U S A
4. dispositif de sectionnement ne peut pas tre ver rouill apposez une tiquette sur le panneau de service pour indiquer que l alimentation a t coup e pour raison d entretien AVERTISSEMENT POUR R DUIRE LE RIS QUE D INCENDIE DE CHOC ELECTRIQUE OU DE PREJUDICE PHYSIQUE RESPECTEZ LES CONSIGNES SUIVANTES quipement requis Q Perceuse lectrique et foret A Tournevis A Maillet en caoutchouc PAGE 1 Tout travail d installation ou c blage lectrique doit tre r alis par une ou des personnes quali fi es conform ment tous les codes et normes applicables y compris ceux relatifs la construc tion r sistante au feu Une circulation d air efficace est requise afin d as surer la combustion et l vacuation compl te des gaz par le tuyau d vacuation chemin e des qui pements combustible pour pr venir les retours d air Suivez les normes et mesures de s curit des fabricants d appareils de chauffage publi es par la National Fire Protection Association NFPA la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB et les autorit s du code local Lorsque vous percez les murs et plafonds vitez d endommager les fils lectriques et les autres canalisations de services publics non visibles Pour obtenir une bonne vacuation de l air veillez ce que l air soit achemin vers l ext rieur Ne pas vacuer l air dans des espaces enferm s par d
5. Thermador An M AA Seon VENTILATION INSTALLATION MANUAL MODEL VTI610D ZN IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance conforms to the relevant safety regulations Repairs should only be carried out by qualified specialists Improperly executed repairs can give rise to significant hazards for the user A Your new appliance was protected on its way to you by the packaging None of the materials cause pollution to the environment and all can be recy cled for use again Please help to protect the environment and dispose of the packaging in an environment friendly manner You can obtain information about the best method disposing of old appliances and packaging from your dealer or local municipal council Check whether this fan may be combined with the extractor hood SAFETY WARNING Before servicing or cleaning unit switch power off at the service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked attach a tag to the service panel to indicate power has been switched off for maintenance WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PER SONS OBSERVE THE FOLLOWING Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction Suf
6. ay be discharged in accordance with official and statutory regulations only e g national building regulations Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use When the extractor hood is operated in exhaust air mode simultaneously with a different burner which also makes use of the same chimney such as gas oil or coal fired heaters continuous flow heaters hot water boilers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of cooking appliances such as hobs and ovens A The fan must be attached at least 78 94 from the extractor hood
7. ben cumplir las reglamentaciones de autoridades locales al liberar el aire en conductos de humo o de salida que no se utilicen para otros fines x Cuando se utiliza la campana extractora en el modo de aire de salida simult neamente con una hor nilla diferente que tambi n utiliza la misma chimenea como calentadores a gas aceite o carb n calentadores de flujo continuo calentadores de agua se debe asegu rar que haya un suministro de aire fresco suficiente que ser necesario para la combusti n en la hornilla La operaci n segura es posible siempre que la subpresi n de la habitaci n donde est instalada la hornilla no supere los 4 Pa 0 04 mbar Esto es posible si el aire de combusti n puede circular a trav s de aberturas que no puedan trabarse como ser puertas y ventanas y a trav s de cajas de entrada salida de aire en la pared o mediante otras medidas t cnicas como enclavamiento rec proco etc Si la entrada de aire es insuficiente existe un riesgo de intoxicaci n con los gases de la combusti n que vuel ven a ingresar a la habitaci n Una caja de entrada salida de aire en la pared por s sola no garantiza que no se superar el valor l mite Nota Al evaluar el requisito total se debe tener en cuenta el sistema de ventilaci n combinado para todo el hogar Esta norma no se aplica al uso de electrodom sticos de cocina como parrillas y hornos A El ventilador debe estar conectado a una distancia m ni
8. es murs ou dans un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT afin de r duire le risque d in cendie n utiliser que des conduits en m tal ATTENTION Pour la ventilation g n rale seule ment Ne pas utiliser l appareil pour vacuer des mati res ou vapeurs dangereuses ou explosives Cet appareil doit tre mis a la terre AVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique ne pas utiliser ce ventilateur avec un r gulateur de vitesse a semi conducteurs Equipement inclus A Boulons d ancrage 4 A Vis 4 A Instruction d installation Q Connecteur AVANT DE PROC DER A L INSTALLATION tape 1 MODE D EVACUATION DE L AIR x L air vici ne doit jamais tre vacu vers un conduit de chemin e ou d vacuation en service pour d autres rai sons ni vers un conduit servant l a ration de pi ces dans lesquelles se trouvent galement des fourneaux ou des chemin es L air vici doit tre vacu conform ment la r gle mentation officielle et l gale seulement p ex la r gle mentation nationale du b timent Si l air vici doit tre vacu par des conduits de chemi n e ou d vacuation qui ne sont pas en service veuillez respecter la r glementation des autorit s locales Lorsque la hotte aspirante est utilis e en mode d vacuation de l air simultan ment avec un br leur diff rent utilisant galement la m me chemin e tels les
9. ficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities To properly exhaust air be sure to duct air out side Do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages WARNING To reduce the risk of fire use only metal ductwork CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapours This unit must be grounded WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device Equipment Needed Equipment Included A Drill and Bit A Anchors 4 A Screwdriver Q Screws 4 Q Rubber Mallet A Installation Instructions Q Connector PAGE 1 PRIOR TO INSTALLATION Step 1 EXHAUST AIR MODE gt Exhaust air should neither be directed into a smoke or exhaust flue that iscurrently used for other purposes not into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located Exhaust air m
10. lador puede combinarse con la campana extractora ADVERTENCIA DE SEGURIDAD Antes de repa rar o limpiar la unidad apague el suministro el c trico en el panel de servicio y trabe el medio de desconexi n del servicio para impedir que se encienda el suministro el ctrico accidentalmente Cuando no se pueda trabar el medio de descone xi n del servicio coloque un letrero en el panel de servicio que indique que se ha apagado el sumi nistro el ctrico para realizar el mantenimiento ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES A PERSONAS SIGA ESTAS INDI CACIONES Equipo necesario A Taladro y broca Q Destornillador Q Mazo de hule El trabajo de instalaci n y el cableado el ctrico deben ser realizados por persona s calificada s de conformidad con todos los c digos y normas aplicables incluidos los de construcci n con rela ci n a incendios Se requiere aire suficiente para la correcta com busti n y extracci n de los gases a trav s del tubo de humo chimenea del equipo quemador de combustible para prevenir el contratiro Siga las pautas del fabricante del equipo de calefac ci n y las normas de seguridad como las publi cadas por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA la Sociedad Americana de Ingenieros en Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Condi
11. ma de 78 44 de la campana extractora A Coloque el ventilador para pared interna nicamente dentro del edificio pero no en salas de estar A Al colocar el ventilador para pared interna aseg rese de que est en un lugar accesible para realizar el manteni miento y las reparaciones A Las conexiones del enchufe y la toma de corriente de los cables el ctricos deben estar ubicadas dentro del edi ficio seg n el c digo local A No reduzca el di metro de 6 de las tuber as conecta das a la campana extractora Paso 2 PREPARACI N DE LA PARED Q La pared debe ser plana y perpendicular A Verifique que la pared pueda sujetar firmemente los tornillos y tacos de montaje Peso en kg 8 8 Nos reservamos el derecho de hacer modificaciones en la construcci n dentro del contexto del desarrollo t cnico P GINA 2 Instalaci n 1 Sostenga el ventilador en la pared Observe la direcci n de la conducci n del aire 2 Marque los 4 agujeros de montaje A Al menos un tornillo debe instalarse a trav s de un pasador A Los tacos deben ser aptos para mamposter a 3 Perfore los 4 agujeros de montaje de Va Introduzca los tacos y atornille el ventilador a la pared 4 Conecte la tuber a del ventilador a la campana extracto ra y p sela hacia el exterior 5 Conecte el ventilador a la campana extractora con un cable de extensi n si fuera necesario Use el conector adicional Use el diagrama
12. ns les salles de s jour A Lorsque vous montez un ventilateur de paroi interne veillez ce qu il soit accessible pour l entretien et les r parations A Les connecteurs a contacts males et femelles des c bles lectriques doivent se trouver a l int rieur du b ti ment conform ment au code local A Ne pas diminuer le diam tre de 6 po des conduites reli es a la hotte aspirante PAGE 2 tape 2 PR PARATION DU MUR A Le mur doit tre plat et perpendiculaire Q Veillez ce que le mur puisse supporter solidement les vis et les prises n cessaires a l installation Poids en kg 8 8 Nous nous r servons le droit d apporter des modifications a l assemblage a la lumi re de d veloppements technolo giques Installation 1 Maintenez le ventilateur en place sur le mur Notez le sens de la conduction de l air 2 Marquez les 4 trous de fixation a percer A Au moins une vis doit tre install e dans un montant A La prise murale doit convenir la ma onnerie 3 Percez les 4 trous de fixation de Va po de diam tre Introduisez les prises murales et vissez le ventilateur dans le mur 4 Connectez la conduite venant du ventilateur la hotte aspirante et branchez la vers l ext rieur 5 Connectez le ventilateur la hotte aspirante l aide d un c ble de prolongement si n cessaire Utilisez le connecteur suppl mentaire Pour effectuer les branche ments se reporter au sch ma de c blage Pour des
13. peed 2 speed 3 speed 4 brown PE green yellow orange blue green yellow PAGE 4 ZN INSTRUCTIONS DE S CURIT IMPORTANTES LIRE ET CONSERVER CES INSTRUCTIONS Cet appareil est conforme aux r glements de s curit pertinents Les r parations doivent uniquement tre effectu es par des sp cialistes qualifi s Les r parations mal ex cut es peuvent engendrer des risques significatifs pour l utilisateur A Votre nouvel appareil a t prot g par un embal lage destin au transport Aucun des mat riaux d emballage n est susceptible d entrainer une pollution de l environnement et tous peuvent tre recycl s pour un usage ult rieur Veuillez contri buer prot ger l environnement et mettre les mat riaux d emballage au rebut dans le respect de l environnement Vous pouvez obtenir des informations sur la meil leure facon de mettre au rebut les vieux appareils lectrom nagers et les mat riaux d emballage aupr s de votre revendeur ou du conseil munici pal local V rifiez si ce ventilateur peut tre mont en asso ciation avec la hotte aspirante AVERTISSEMENT DE S CURIT Avant de proc der a la r paration ou au nettoyage de l ap pareil coupez l alimentation lectrique au niveau du tableau de distribution et verrouillez le disposi tif de sectionnement pour emp cher un r tablis sement accidentel de l alimentation Lorsque le
14. raisons de s curit le couvercle de prise suppl mentaire doit toujours tre fix et ferm Les c bles non utilis s doivent tre isol s recou verts avec des capuchons de connexion et entrepos s dans une position non dangereuse PAGE 3 SCH MA DE C BLAGE vitesse 1 rouge vitesse 2 bleu vitesse 3 orange vitesse 4 marron N blanc PE vert jaune orange blanc orange bleu bleu rouge marron L 2 rouge N C2 blanc N vert jaune PAGE 4 marron vert jaune ZN INSTRUCCIONES DE SEGURIDAD IMPORTANTES LEA Y CONSERVE ESTAS INSTRUCCIONES Este electrodom stico cumple con las reglamentacio nes de seguridad correspondientes Las reparaciones deben ser realizadas por especialis tas calificados nicamente Las reparaciones realizadas incorrectamente pueden dar lugar a serios peligros para el usuario A Su nuevo electrodom stico fue protegido durante el transporte a su domicilio con material de emba laje Ninguno de los materiales contamina el medioambiente y todos se pueden reciclar para volverse a usar Ayude a proteger el medioambien te y deseche el embalaje de manera ecol gica Puede obtener informaci n sobre el mejor m to do para desechar los electrodom sticos viejos y el embalaje consultando a su distribuidor o al concejo municipal local Verifique si este venti
15. tioning Engineers ASHRAB y las autoridades de c digos locales Al cortar o perforar paredes o techos tenga cui dado de no da ar el cableado el ctrico ni las ins talaciones ocultas de los dem s servicios Para hacer que el aire salga al exterior correcta mente aseg rese de que haya un conducto que lo dirija hasta afuera No dirija el aire de salida hacia espacios dentro de paredes techos ticos huecos sanitarios o garajes ADVERTENCIA Para reducir el riesgo de incen dio s lo utilice conductos de metal PRECAUCI N Solamente para uso general de ventilaci n No use la campana para extraer materiales ni vapores peligrosos o explosivos Esta unidad debe estar conectada a tierra ADVERTENCIA Para reducir el riesgo de incen dio o descarga el ctrica no use el ventilador con ning n dispositivo de control de velocidad de estado s lido Equipo incluido A Anclajes 4 a Tornillos 4 A Instrucciones de instalaci n QA Conector P GINA 1 ANTES DE LA INSTALACI N Paso 1 MODO DE AIRE DE SALIDA gt El aire de salida no debe ser dirigido a un conducto de humo ni de salida que actualmente se utilice para otros fines ni a un hueco que se utilice para ventilar habitacio nes en las cuales tambi n se encuentran estufas o chime neas El aire de salida puede liberarse s lo respetando las reglamentaciones oficiales y legales p ej reglamen taciones nacionales sobre construcci n Se de
Download Pdf Manuals
Related Search
Related Contents
RL00015005 USER MANUAL Icom IC-756 Pro User manual Philips CP9934 Dell Wyse 2GB Flash upgrade kit Dataflex Cable Eater ø20/3m & Hand Tool 773 TheraScreen®: K-RAS Mutation Kit TECHNI -DATA - Larose & Fils attention - AGA Marvel Copyright © All rights reserved.
Failed to retrieve file