Home

Thermador CEP User's Manual

image

Contents

1. Thermador 4 Anerican Jeon Installation Instructions Thermador Glass Ceramic Coolctops Models CEF CEP CET Installation Instructions Models CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 TABLE OF CONTENTS NOTE The blocked letters such as A shown below refer to illus trations on Pages 2 amp 4 Match these to the related text pages Overall Dimensions A Power Supply B Cabinet Preparation and Clearances C Junction Box Location D Countertop Cutout Dimensions E Installing the Cooktop F Secure Cooktop to Countertop G Solid Surface Countertop Installs H Installation above a Single Oven I J K and L Electrical Connection IMPORTANT Save these instructions for Local Electrical Inspector s use INSTALLER Please leave these Installation Instructions with this unit for the owner OWNER Please retain these instructions for future reference READ AND SAVE THESE INSTRUCTIONS OVERALL DIMENSIONS A JUNCTION BOX LOCATION D See Illustration A Page 2 These dimensions are Plan the installation of the unit so that the location of overall the junction box is within 3 feet of the right rear of the cooktop bottom It must be accessible from the POWER SUPPLY B front of the cabinet An exception to this location _ _ _ _ _ QQ o WOuld be for a cooktop installation over a single electric ELECTRICAL POWER CONNECTION FOR oven In that situation refer to Pages 4 and 5 and COOKTOP
2. PR PARATION DE L ARMOIRE ET DEGAGEMENTS C Pour liminer le risque de br lures ou d incendie en se penchant au dessus de la surface chaude le rangement dans l armoire au dessus de l appareil devrait tre vit SInon r duire le risque en installant une hotte qui projette horizontalement d un minimum de 5 po 127 mm au del du bas des armoires Voir C page 2 Cet appareil est con u pour une installation dans un plan de travail avec d gagement z ro aux murs adjacents et surfaces fabriqu s en mat riaux combustibles Un d gagement minimum de 30 po est requis entre le haut de la plaque de cuisson et le bas d une armoire non prot g e Un d gagement minimum de 24 po est n cessaire lorsque le bas de l armoire en bois ou en m tal est prot g par non moins de 1 4 po de mat riaux ingnifuges couvert par non moins par n 28 MSG de feuille de mt al acier de 0 015 po 0 4 mm d paisseur aluminium de 0 024 po 0 6 mm ou cuivre 0 020 po 0 5 mm Les mat riaux ignifuges portent la marque UNDERWRITERS LABORATORIES INC laboratoires des assureurs CLASSIFIE CARACTERISTIQUES DE BRULAGE DE SURFACE EN PANNEAU DE FIBRES ET MINERAUX suivi par les cotes de fum e et de propagation ces d signations figurent comme FHC Flame Spread Smoke Developed propagation des flammes et d veloppement de la fum e Les mat riaux avec une cote de propagation 0 sont ignifuges Les codes locaux peuvent permettre d a
3. PAGE 3 CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Instructions d installation Mod les CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Boitier de Connecteur de Nu DL conduit pivotant o KT Joint de ruban Bloc en bois Vis de 4 r glage F Ruban en mousse scellant Attaches de fixation Indique l emplacement du ruban r fl chissant en aluminium Apposer le ruban sur les c t s verticaux de la d coupe nominal de base 4 po I Marquer les lignes centrales de la d coupe de la plaque de cuisson Marques les lignes centrales de la d coupe pour le four S301 C301 ou SC301 et de la plaque de cuisson 4 7 8 po Trou de 7 po de diam pour tuyau d vent 4 po de diam conduit pour four vent externe seulement Boite de jonction pour conduit de plaque de cuisson Qn 27 3 8 po Conduit de la plaque de Bo te de cuisson jonction pour sn Bord expos doit conduit de tre une coupe finie Bo te de ser sans cadre Cadre du four rebord typique Espace 5 8 po nominal 4 K Emplacement des bo tes de jonction po pour bas du four et du trou d vent 2 x 4 supports L Ouverture verticale de la d coupe du four PAGE 4 Instructions d installation PLAN DE TRAVAIL SOLIDE H Toujours consulter le fabricant du plan de travail concernant les instructions sp cifiques Les plans de travail fabriqu s en mat riaux naturels ex granite et marbre ou SURFACES SOLIDES comme
4. du four simple Si un four simple est install sous le plan de travail voir figure K pour l emplacement des boites de jonction REMARQUE Les fours simples Thermador mod les 301 SC301 C301 et CM 301 install s sous le plan de travail avec une plaque de cuisson lectrique Thermador au dessus sont approuv s U L pour l installation Mod les CONNEXION LECTRIQUE Attacher un conduit flexible la bo te de jonction 2 Brancher les fils de la plaque de cuisson sur les fils d alimentation de la bo te de jonction de fa on appropri e Pour les mod les CEF CET et CEP brancher le noir L1 sur le noir rouge L 2 sur le rouge fil vert sur la mise la terre blanc neutre sur blanc REMARQUE si la plaque de cuisson est install e et branch e tel qu il est sp cifi ci dessus elle sera enti rement mise la terre conform ment au Code national d lectricit 3 Enlever tout de la surface de la plaque de cuisson et appliquer la cr me nettoyante pour plaques de cuisson emball e avec l appareil tel qu il est indiqu dans le guide d utilisation et d entretien page 14 Mettre l alimentation en circuit V rifier le fonctionement ATTENTION La surface de la plaque de cuisson doit tre nettoy e quotidiennement Consulter la section sur l entretien et l utilisation avant d utiliser la premi re fois PAGE 5 CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Instructions d
5. installation Mod les CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 AVANT D EFFECTUER UN APPEL DE SERVICE Si les l ments ne chauffent pas ou si le voyant marche ne s allume pas v rifier la source d alimentation pour voir si un fusible a grill ou si le coupe circuit a d clench Consulter la garantie de la plaque de cuisson la page 17 du guide d utilisation et d entretien PLAQUE SIGNALETIQUE La plaque signal tique indique le mod le et le num ro de s rie de la plaque de cuisson Elle est situ e sur le devant du centre du boitier sous la plaque de cuisson et imprim e sur le couvercle derri re Conserver la facture ou tout document pertinent pour valider la garantie si un service est n cessaire PAGE 6 Instrucciones de Instalaci n Modelos CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 CONTENIDO XNOTA Las letras may sculas como la A que aparecen abajo se refieren a ilustraciones en las p ginas 2 y 4 Empareje stas a las p ginas de texto relacionadas Dimensiones Generales A Fuente de Alimentaci n B Preparaci n de Gabinetes y Espacios Libres C Ubicaci n de la Caja de Conexiones D Dimensiones del Recorte de la Cubierta E Instalar la estufa F Fijar la Estufa a la Cubierta G Instalaci n en Cubierta con Superficie S lida H Instalaci n arriba de un Solo Horno I J K y L Conexi n El ctrica IMPORTANTE INSTALADOR PROPIETARIO Guarde estas instrucci
6. y 3 Instale la estufa del siguiente modo Redondee las esquinas del recorte de acuerdo a las instrucciones del fabricante de la cubierta Aplique cinta reflectante del calor tal como Cinta Scotch de Papel de Aluminio 425 o 427 alrededor del recorte dobl ndola sobre la parte superior y los costados Aseg rese que la cinta se extiende m s all del reborde exterior de la estufa La cinta debe tapar todas las esquinas Fije los soportes de retenci n a la caja empotrada usando las arandelas y los tornillos que se incluyen Utilice un bloque de madera abajo de la cubierta antes de apretar los tornillos de los soportes Centre la estufa en el recorte para asegurar un espacio libre adecuado entre la caja empotrada y el borde de la cubierta Una marca ligera con l piz a lo largo del centro del borde delantero y del borde lateral de la estufa y de la cubierta ayudar a posicionar la estufa en el centro Corte el exceso de la cinta de aluminio a lo largo de los bordes del cuadro TENGA CUIDADO de no raspar la cubierta Instalaci n arriba de un solo horno S301 SC301 C301 CM 301 Opcional I J K y L Se puede instalar la estufa arriba de un solo horno el ctrico de Thermador Se debe posicionar la estufa sobre la misma l nea de centro como el horno sencillo abajo de la cubierta Cuando se instala un solo horno abajo de la estufa vea la Figura K para la ubicaci n de las cajas de conexiones NOTA Modelos S301 SC
7. 301 C301 y CM 301 del horno sencillo de Thermador instalados abajo de la cubierta con una estufa el ctrica Thermador arriba es una instalaci n aprobada por UL Modelos CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 CONEXI N EL CTRICA Il Conecte el conducto flexible a la caja de conexiones Conecte los cables de la estufa a los cables de alimentaci n en la caja de conexiones con la fase apropiada Para los modelos CEF CET Y CEP conecte el alambre negro L1 a negro rojo L2 a rojo el alambre verde a tierra blanco neutro a blanco NOTA Cuando se instale y conecte la estufa como se especifica arriba estar completamente puesta a tierra seg n el C digo El ctrico Nacional Quite todo de la superficie de la estufa y aplique la Crema de Limpieza para la estufa viene incluida con la estufa tal como se instruye en el Manual de Uso y Cuidado p gina 14 Prenda la fuente de alimentaci n el ctrica Compruebe la operaci n CUIDADO Diariamente es necesario que usted limpie la superficie de la estufa Consulte la secci n de Uso y Cuidado antes de usarla por primera vez P GINA 5 ANTES DE SOLICITAR SERVICIO Cuando no se calientan los elementos o cuando no se ilumina la luz indicadora de encendido revise la fuente de alimentaci n el ctrica para ver si se quem un fusible o si se desconect el interruptor principal Consulte la Garant a de la Estufa en la p gina 17 del Manu
8. Figures I J K and L Power Supply is dual rated 240 Volts or 208 Volts 4 wire 60 Hz with the following circuit breaker requirements Models CEF304 CET304 or CEP304 at 30 Amps Models CEF365 CET365 or CEP365 at 40 Amps or Model CEP456 at 50 Amps Install a junction box not supplied below the counter top within 3 feet of flexible conduit supplied located at the right rear corner of the cooktop rough in box PAGE 1 Installation Instructions Models CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Models CEF304 CET304 CEP304 Width 31 Models CEF304 CET304 CEP304 30 Amp circuit breaker Models CEF365 CET365 CEP365 Width 37 Models CEF365 CET365 CEP365 40 Amp circuit breaker Models CEP456 Width 46 Models CEP456 50 Amp circuit breaker All Models Depth 21 5 8 Height above countertop 1 4 CEF CET and CEP Models 240 Volt 4 Wire 60 Hz 208 Volt 4 Wire 60 Hz A Overall Dimensions B Power Supply Cabinet Building Side Wall Building Back Cooking Surface Minimum Cabinet Clearances D Junction Box Location 1 Flat Area 1 3 4 Flat Area 1 Flat Area Setback Distance from front edge of counter top to front edge of cutout COUNTER CUTOUT DIMENSIONS Minimum in mm Maximum in mm CEF304 CEP304 B 19 7 8 505 20 508 CET304 C 28 3 4 731 20 7 8 530 2 gt U U 08 34 3 4 883 35 891 197 07 508 B 9 7 8 505 43 3 4 1111 43 7 8 1114 For so
9. SurellMC et Corian requi rent une pr paration de d coupe et une marche suivre d installation sp ciales Voir pages 2 et 3 Installer la plaque de cuisson comme suit Arrondir les coins de d coupe selon les instructions du fabricant du plan de travail Apposer du ruban r fl chissant la chaleur comme du ruban aluminium Scotch n 425 ou 427 autour de la d coupe de fa on a ce qu il se plie sur le dessus et les surfaces lat rales S assurer que le ruban se prolonge plus loin que le bord de la plaque de cuisson Tous les coins doivent tre galement couverts avec du ruban Fixer les attaches au boitier de br leur a l aide des vis et rondelles fournies Utiliser un bloc de bois sous le plan de travail avant de serrer les vis des attaches Centrer la plaque de cuisson dans la d coupe pour assurer un d gagement ad quat entre le boitier de br leur et le bord du plan de travail Une l g re marque au crayon le long du centre avant et des bords lat raux de la plaque de cuisson et du plan de travail permettra de mieux positionner l appareil au centre Enlever l exc s de ruban aluminium le long des bords du cadre FAIRE ATTENTION a ne pas gratigner le plan de travail Installation au dessus du four 301 SC301 C301 CM 301 optionnelle I J K et L La plaque de cuisson peut tre install e au dessus d un four lectrique simple Thermador La plaque doit tre situ e sur la m me ligne centrale que celle
10. al de Uso y Cuidado PLACA CON INFORMACI N DEL PRODUCTO La placa con informaci n muestra el modelo y el n mero de serie de su estufa Se encuentra en el rea central delantera de la caja empotrada abajo de la estufa y est impresa en la contraportada Guarde su factura o papeles para la validaci n de la garant a cuando se requiere servicio Specifications are for planning purposes only Refer to installation instructions and consult your countertop supplier prior to making counter opening Consult with a heating and ventilating engineer for your specific ventilation requirements For the most detailed information refer to installation instructions accompanying product or write Thermador indicating the model number We reserve the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United States for use in Canada Check with your local Canadian distributor or dealer Thermador 5551 McFadden Avenue Huntington Beach CA 92649 For the most up to date critical installation dimensions by fax use your fax handset and call 702 833 3600 Use code 8030 Thermador Ha n e Seon 5551 McFadden Avenue Huntington Beach CA 92649 e 800 735 4328 9000064002 No ECO e 10012 Rev A e 01 05 2005 BSH Home Appliances Corp e Litho in U S A PAGINA 6
11. allation de la plaque de cuisson F Fixation de la plaque de cuisson au plan de travail G Installation de la plaque de cuisson sur une surface solide H Installation au dessus d un four simple I J K et L Connexion lectrique IMPORTANT conserver ces instructions a des fins d utilisation par l inspecteurlocal en lectricit laisser ces instructions d installation avec l appareil por le propri taire conserver ces instructions des fins de r f rences LIRE ET CONSERVER CES INSTRUCTIONS DIMENSIONS HORS TOUT A Voir illustration A page 2 Ces dimensions sont hors tout INSTALLATEUR PROPRIETAIRE EMPLACEMENT DE LA BO TE DE JONCTION Planifier l installation del appareil afin que l emplacement de la boite de jonction doit moins de 3 pi de l arri re droite du bas de la plaque de cuisson ALIMENTATION BD it etre accessible depuis le devant de CONNEXION DE L ALIMENTATION LECTRIQUE POUR LA PLAQUE DE CUISSON L alimentation est cote jumel e 240 ou 208 volts 4 fils 60 Hz avec les exigences suivantes pour le coupe circuit mod le CET304 ou CEP304 30 Amp mod le CET365 ou CEP365 40 Amp ou mod lel CEP456 50 Amp Installer une boite de jonction non comprise sous le plan de travail a moins de 3 pieds du conduit flexible fourni situ au coin arri re droite du boitier de la plaque de cuisson l armoire Seule exception a cet emplacement est si l installation est au dessus d un four l
12. de llamas El m nimo espacio libre horizontal desde los costados y el borde trasero de la estufa a las paredes combus tibles verticales adyacentes es de 0 cent metros Modelos CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 DIMENSIONES DEL RECORTE DE LA CUBIERTA E Las dimensiones del recorte dependen si la instalaci n es para el reemplazo una construcci n nueva o la instalaci n en un material s lido de la cubierta tal como Surell Corian etc Estos materiales necesitan recortes m s grandes el uso de cinta termoreflectora y esquinas redondeadas Los dibujos G y H s lo ofrecen algunos lineamientos vea la p gina 4 Siempre consulte al fabricante de su cubierta para las instrucciones de instalaci n espec ficas INSTALAR LA ESTUFA F d ADVERTENCIA DESCONECTE LA CORRIENTE ANTES DE LA INSTALACI N ANTES DE PRENDER LA ESTUFA ASEG RESE QUE TODOS LOS CONTROLOES EST N EN LA POSICI N DE APAGADO FIJAR LA ESTUFA A LA CUBIERTA G Se debe fijar la estufa a la cubierta usando los soportes de retenci n que vienen incluidos Antes de meter la estufa al recorte voltee la estufa y fije las abrazaderas a la caja empotrada utilizando las arandelas y los tornillos Coloque la estufa en el recorte Inserte el tornillo de retenci n en el soporte y fije la estufa a la cubierta Utilice un bloque de madera para proteger los materiales fr giles de la cubierta P GINA 3 Instrucciones de Instalac
13. ectrique simple Dans ce cas se r f rer aux pages 4 et 5 et figures I J K et L PAGE 1 Instructions d installation Mod les CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Mod les CEF304 CET304 CEP304 largeur 31 po Mod les CEF304 CET304 CEP 304 coupe circuit 30 Amp Mod les CEF365 CET365 et CEP365 largeur 37 po Mod les CEF365 CET365 et CEP365 coupe circuit Mod le CEP456 largeur 46 po 40 Amp Tous les mod les profondeur 21 5 8 po Mod le CEP456 coupe circuit 50 Amp hauteur au dessus du plan de travail Ya po Mod les CEF CET et CEP 240 volts 4 fils 60 Hz 208 volts 4 fils 60 Hz g y Tous avec conduit flexible 3 pi fourni A Dimensions hors tout B tas PA Bas de l armoire non prot g e N Mur lat ral Surface de cuisson D gagements minimums d armoire 2 1 2 A Depuis le bord avant du comptoir jusqu au bord avant de la d coupe DIMENSIONS N MODELE Minimum en DE D COUPE Maximum en pouces mm pouce mm CEF304 CEP304 B 19 7 8 505 20 508 CET304 C 28 3 4 731 20 7 8 530 i 9 7 8 0 07 508 34 3 4 883 35 891 197 O 7 508 B 8 505 43 3 4 1111 43 7 8 1114 Pour les installations sur plan de travail a surface solide utiliser les dimensions de decoupe maximale et consulter le fabricant du plan de travail concernant les directives sp cifiques Dimensions de d coupe du plan de travail PAGE 2 Instructions d installation
14. ento en gabinetes ubicados arriba de la estufa Cuando es necesario proporcionar gabinetes de almacenamiento se puede reducir el riesgo al instalar una campana que sobresalga horizontalmente un m nimo de 5 pulg 127 mm mas alla del fondo de los gabinetes Vea C pagina 2 Esta unidad est dise ada para una instalaci n en la cubierta con cero espacio libre a las paredes adyacentes y superficies salientes construido de materiales combustibles Se requiere un espacio libre minimo de 30 pulg 76 cm entre la parte superior de la estufa y la parte inferior de un gabinete no protegido Se requiere una distancia m nima de 24 pulg 61 cm cuando el fondo del gabinete de madera o metal est protegido por no menos de 1 4 pulg 0 6 cm de un material retardante al fuego cubierto con hojalata MSG No 28 de acero inoxidable con un grosor de 0 015 pulg 0 4 mm aluminio con un grosor de 0 024 pulg 0 6 mm o cobre con un grosor de 0 020 pulg 0 5 mm Los materiales retardantes al fuego llevan la leyenda UNDERWRITERS LABORATORIES INC CLASIFICADO TABLEROS DE FIBRA Y MINERALES CARACTERISTICAS DE COMBUSTION DE SUPERFICIES Seguido por las tasas de propagaci n de llamas y humo estas designaciones se indican como FHC Propagaci n de Llamas Humo Desarrollado Materiales con una tasa de propagaci n de llamas de O son retardantes al fuego de combusti n lenta Los c digos locales pueden permitir otras tasas de propagaci n
15. external vent oven only Oven frame 3 8 overlap J Box for cooktop conduit overlap bottom 5 8 Overlap Typ Locations of Oven Junction Box and Vent Hole Models CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Burner Box eS ZQ l Ll POEPIE ii Adjusting Screw Hold Down Brackets Wood Block G Shows location of aluminum reflective tape Tape top and vertical sides of cutout 4 Nominal Toe Space 28 12 Mark Center Lines of S301 C301 or SC301 Oven and Cooktop Cutout 3 5 8 Min Cooktop va Conduit Exposed edge must be a finish cut 4 Nominal Toe Space Vertical Opening of Oven Cutout PAGE 4 Installation Instructions SOLID SURFACE COUNTERTOPS H Alvvays consult the countertop manufacturer for specific instructions Countertops made from natural i e granite and marble or SOLID SURFACE MATERIALS such as Surell and Corian require special cutout preparation and installation procedures Follow the guidelines in preparing the cutout dimensions Refer to Pages 2 and 3 Install the cooktop as follows Round the cutout corners according to instructions from the countertop manufacturer Apply heat reflective tape such as Scotch Aluminum Foil Tape 425 or 427 around the cutout so that it folds over the top and side surfaces Be sure the tape extends beyond the outermost flange of the cooktop All corners should also be covered with tape Attach brackets
16. flame retardant Local codes may allow other flame spread ratings The minimum horizontal clearance from the sides and back edge of the cooktop to the adjacent vertical combustible walls is 0 Inches Models CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 COUNTERTOP CUTOUT DIMENSIONS The cutout dimensions depend upon whether the installation is for replacement new construction or installation in a solid surface countertop material such as Surell Corian etc These materials require larger cutouts use of heat reflective tape and rounded corners Drawings G and H provide some guidelines only see Page 4 Always consult the countertop manufacturer for specific Installation Instructions F WARNING DISCONNECT POWER BEFORE INSTALLING BEFORE TURNING POWER ON BE SURE THAT ALL CONTROLS ARE IN OFF POSITION INSTALLING THE COOKTOP SECURE COOKTOP TO COUNTERTOP G The cooktop should be secured to the countertop using the hold down brackets provided Prior to inserting cooktop into cutout turn cooktop upside down and attach brackets to the burner box using the washers and screws Place cooktop into cutout Insert clamping screw into the bracket and secure cooktop to countertop Use a wood block to protect fragile countertop materials PAGE 3 Installation Instructions Swivel Conduit Connector Foam Tape Sealant F Foam Tape Sealant 4 7 8 7 Dia Hole for 4 Dia Vent Pipe Duct for
17. i n Modelos CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Caja Empotrada Conector Bloque de Madera Giratorio del Conducto soporta S A Q Ki Cinta de Espuma DON Tornillo de 4 Ajuste F Sellado con Cinta de Espuma G Soportes de Retenci n Muestra la ubicaci n de la cinta reflejante de aluminio Ponga cinta en la parte superior y los costados del recorte 4 Espacio Nominal 287 para los Pies I Marcar las Lineas de Centro del Recorte de la Estufa J Marcar las Lineas de Centro del Recorte del Horno y Estufa de S301 C301 o SC301 4 7 8 re 16 1 2 Orificio 7 Di para Tubo de Ventila con Di 4 Ducto s lo para ventilaci n externa del horno Cuadro del horno 3 8 solape 27 3 8 ds Conducto de la Estufa El borde expuesto debe ser de un Caja de Corlexiones para el conducto del 4 Espacio No solape Nominal gel cuadro sp lero dal para los Pies 3 4 men oe J Ubicaciones de la Caja de Conexiones del Horno y Orificio de Ventilaci n Apertura Vertical del Recorte de Horno P GINA 4 Instrucciones de Instalaci n CUBIERTAS CON SUPERFICIE S LIDA H Siempre consulte al fabricante de la cubierta para recibir instrucciones espec ficas Las cubiertas fabricadas de materiales naturales ej granito y m rmol o MATERIALES PARA SUPERFICIES SOLIDAS tal como Surell and Corian requieren de procedimientos especiales de instalaci n y preparaci n del recorte Consulte las p ginas 2
18. lid surface countertop installations use maximum cutout dimensions and consult solid surface manufacturer for specific directions PAGE 2 Installation Instructions CABINET PREPARATION AND CLEARANCES C To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 in 127 mm beyond the bottom of the cabinets See C Page 2 This unit is designed for installation in the counter top with zero clearance to adjacent walls and projecting surfaces constructed of combustible materials A 30 inch minimum clearance is required between the top of the cooktop and the bottom of an unprotected cabinet A 24 inch minimum distance is necessary when the bottom of the wood or metal cabinet is protected by not less than 1 4 inch of a flame retardant material covered with not less than No 28 MSG sheet steel 0 015 inch 0 4 mm thick stainless steel 0 024 inch 0 6 mm aluminum or 0 020 inch 0 5 mm thick copper Flame retardant materials bear the mark UNDERWRITERS LABORATORIES INC CLASSIFIED MINERAL AND FIBER BOARDS SURFACE BURNING CHARACTERISTICS Followed by the flame spread and smoke ratings these designations are shown as FHC Flame Spread Smoke Developed Materials with O flame spread ratings are
19. o de 30 Amp Modelos CEF304 CET365 y CEP365 Modelo CET456 Ancho 46 Coen aCe eine Modelo CEP456 Cortocircuito de 50 Amp Modelos CEF304 CET365 y CEP365 Ancho 37 Todos los Modelos Profundidad 21 5 8 Altura arriba de la cubierta 1 4 Modelos 240 Voltios 4 hilos 60 HZ CEF304 CET y CEP 208 Voltios 4 hilos 60 Hz Todos con conducto flexible de 1m incluido A Dimensiones Generales B Fuente de Alimentaci n Pared lateral del edificio trasera del A oe edificio 1 Caja de 3 Conexiones Espacios Libres D M nimos del Gabinete Ubicaci n de la Caja de Conexiones 1 Area Plana QT 1 3 4 Area PI 30 Minimo EA 5 rea Plana A gt 2 1 2 Del borde anterior de la sobrefaz del borde anterior del recorte DIMENSIONES M nimo DEL RECORTE M ximo pulgadas mm pulgadas mm CEF304 CEP304 B 19 7 8 505 20 508 CET304 C 28 3 4 731 20 7 8 530 2 O U U Ud cl 3834 6889 9 7 Q 508 C B 5 505 43 3 4 1111 43 7 8 1114 Para instalaciones en cubiertas con superficies s lidas use las m ximas dimensiones de recorte y consulte al fabricante de la superficie s lida para indicaciones espec ficas Dimensiones del Recorte de la Cubierta P GINA 2 Instrucciones de Instalaci n PREPARACI N DE GABINETES Y ESPACIOS LIBRES C Para eliminar el riesgo de quemaduras o fuego cuando extiende las manos encima de unidades con superficies calientes se debe evitar el espacio de almacenami
20. onal Electrical Code 3 Remove everything from the cooktop surface and apply Cooktop Cleaning Creme packaged with cooktop as directed in Care amp Use Manual Page 14 Turn on power supply Test operation A CAUTION Your cooktop surface needs to be cleaned daily Refer to the Care and Use section before using it for the first time PAGE 5 Installation Instructions Models CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 BEFORE CALLING FOR SERVICE If the elements do not heat or if the indicator on light does not glow check the power source to see if a fuse has blown or if the circuit breaker has tripped Refer to the Cooktop Warranty on Page 17 of the Care and Use Manual PRODUCT DATA PLATE The data plate shows the model and serial number of your cooktop It is located in the center front area of the rough in box underneath the cooktop and printed on the back cover Keep your invoice or escrow papers for warranty validation if service is needed PAGE 6 Instructions d installation Mod les CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 TABLE DES MATIERES REMARQUE les lettres comme A indiqu es ci dessous r f rent aux illustrations aux pages 2 et 4 Les faire correspondre aux pages appropri es Dimensions hors tout A Alimentation B Pr paration de l armoire et d gagements C Emplacement de la boite de jonction D Dimensions de d coupe du plan de travail E Inst
21. ones para el uso del inspector electricista local Deje estas instrucciones con la unidad para el propietario Guarde estas instrucciones para el futuro LEA Y GUARDE ESTAS INSTRUCCIONES DIMENSIONES GENERALES A Vea la ilustraci n A p gina 2 Son las dimensiones generales FUENTE DE ALIMENTACI N B CONEXI N DE ALIMENTACI N EL CTRICA PARA LA ESTUFA La fuente de alimentaci n es de doble salida nominal 240 Voltios o 208 Voltios 4 hilos 60 Hz con los siguientes requerimientos del cortocircuito Modelos CET304 o CEP304 a 30 Amps Modelos CET365 o CEP365 a 40 Amps o Modelo CEP456 a 50 Amps Instale una caja de conexiones no viene incluida abajo de la cubierta dentro de 3 pies 1 m del conductor flexible incluido ubicado en la esquina trasera derecha de la caja empotrada de la estufa UBICACI N DE LA CAJA DE CONEXIONES D Planee la instalaci n de la unidad de tal forma que la ubicaci n de la caja de conexiones quede dentro de 3 pies 91 m de la parte trasera derecha del fondo de la estufa Debe ser accesible desde el frente del gabinete Una excepci n para esta ubicaci n ser a para la instalaci n de una estufa arriba de un horno sencillo En esa situaci n consulte las p ginas 4 y 5 y las figuras 1 J K y L P GINA 1 Instrucciones de Instalaci n Modelos CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 Modelos CEF304 CET304 CEP304 Ancho 31 Modelos CEF304 CET304 y CEP304 Cortocircuit
22. to the burner box using washers and screws provided Use a wooden block underneath the countertop before tightening the bracket screws Center cooktop in the cutout to insure adequate clearance between the burner box and countertop edge A light pencil mark along the center of front edge and side edge of cooktop and counter will aid positioning of the cooktop in the center Trim excess aluminum tape along the frame edges BE CAREFUL not to scratch the countertop Installation above an oven S301 SC301 C301 CM 301 Optional I J K and L The cooktop can be installed over a single Thermador electric oven The cooktop should be located on the same center line as the under the counter single oven If a single oven is installed under the cooktop see Figure K for the location of the junction boxes NOTE Thermador single oven Models S301 SC301 C301 and CM 301 installed under the counter with a Thermador electric cooktop over it is a UL approved installation Models CEF304 CEF365 CET304 CET365 CEP304 CEP365 CEP456 ELECTRICAL CONNECTION Attach flexible conduit to the junction box 2 Connect the cooktop lead wires to the junction box supply wires in proper phase For CEF CET AND CEP models connect black L1 to black red L2 to red green wire to ground white neutral to white NOTE If the cooktop is installed and connected as specified above it will be completely grounded in compliance with the Nati
23. utres cotes de propagation de flammes Le d gagement minimum horizontal des c t s et des bords arri res de la plaque de cuisson aux murs combustibles verticaux adjacents est de O po Mod les DIMENSIONS DE D COUPE DU PLAN DE TRAVAIL E Les dimensions de d coupe d pendent si l installation est un remplacement nouvelle construction ou installation sur un plan de travail solide comme Surell Corian etc Ces mat riaux requi rent de plus grandes d coupes l utilisation de ruban r fl chissant la chaleur et des coins arrondis Les dessis G et H donnent les grandes lignes seulement voir page 4 Toujours consulter le fabricant du plan de travail concernant les instructions d installation sp cifiques INSTALLATION DE LA PLAQUE DE CUISSON F A AVERTISSEMENT D BRANCHER L ALIMENTATION AVANT D INSTALLER AVANT DE METTRE L ALIMENTATION EN CIRCUIT S ASSURER QUE TOUS LES CONTR LES SONT EN POSITION OFF FIXATION DE LA PLAQUE DE CUISSON AU PLAN DE TRAVAIL La plaque de cuisson doit tre fix e de fa on s curitaire au plan de travail l aide des attaches fournies Avant d ins rer la plaque de cuisson dans la d coupe la mettre l envers et fixer les attaches au bo tier de br leur l aide des vis et rondelles Mettre la plaque de cuisson dans la d coupe Ins rer les vis de fixation sur les attaches et fixer la plaque au plan de travail Utiliser un bloc en bois pour prot ger le plan de travail