1. QUICKSTART GUIDE MODEL 3000TA XL EU Trace Oxygen Analyzer 1 Teledyne Analytical Instruments Quickstart Guide Trace Oxygen Analyzer EENS Teledyne Analytical Instruments Model 3000 TA XL EU Quickstart Guide RE EE SP ee ae GETTING STARTED This Quickstart Guide is designed to get you set up and operating your Teledyne Analytical Instruments Analyzer quickly It shortcuts the details so you can install and use your new analyzer with a minimum of fuss This Quickstart Guide should be used in conjunction with the Instruction Manual that shipped with your instrument Only necessary features to get you operational are discussed in this guide Many of the advanced features of this analyzer are not described here so you should refer to the Instruction Manual to get the most from your analyzer Front Panel Operator Interface Take a minute to familiarize yourself with the analyzer s interface The standard 3000TA EU is housed in a rugged metal case with all controls and displays accessible from the front panel The operator interface consists of thirteen buttons for operating the analyzer a digital meter an alphanumeric display and a window for viewing the sample flowmeter Door Latch Digital Meter Alphanumeric Display Sample System Flow Indicator Standby Switch Data Entry Function Buttons Buttons Teledyne Analytical Instruments 1 Quickstart Guide Trace Oxygen Analyzer eee ee Function K
2. to 10 000 00 ppm e Out of range direction HI or LO e Defeated Dft Y N Yes No e Failsafe Fs YIN Yes No e Latching Ltch Y N Yes No e To change any of the alarm parameters use the lt P arrow keys to move the blinking over to the specific parameter e Use the A V arrow keys to change the value of the parameter Holding down the key speeds up the incrementing or decrementing e Once the parameters for alarm 1 have been set press Alarms again and repeat this procedure for alarm 2 AL 2 e To reset a latched alarm go to Dft and then press either A two times or Y two times Toggle it to Y and then back to N Go to Ltch and then press either two times or Y two times Toggle it to N and back to Y Set The Range Function To set the 3 programmable ranges e Enter the range function mode by pressing the Range button on the front panel L 1 M 10 H 100 Mode AUTO Teledyne Analytical Instruments 14 Model 3000 TA XL EU Quickstart Guide EE EE a Ee Se e Use the lt gt arrow keys to blink the range to be set low L medium M or high H e Use the A Y arrow keys to enter the upper value of the range all ranges begin at 0 ppm Repeat for each range you want to set e Press Enter to accept the values and return to analyze mode Note The ranges must be increasing from low to high for example if range 1 is set as 0 100 ppm and range 2 is set as 0 1 000 ppm range 3 cannot be set as 0 50
3. Calib Holding time Cal hold 5 min e Press Enter key to continue Span Val 000008 00 lt ENT gt Span lt UP gt Mod e Press A lt UP gt to permit modification Mod of span value e Use the arrow keys to enter the oxygen concentration of the span gas you are using 209000 00 if you are using air The ak arrows choose the digit and the A V arrows choose the value of the digit e Press Enter to enter the span value into the system and begin the span calibration HHEH Span Slope ppm s e When the Span value displayed on the screen is sufficiently stable press Enter and the span reading changes to the correct value The instrument automatically returns to the Analyze mode Setting Alarm Parameters If you are using password protection you will need to enter your password to access the alarm functions Follow the instructions above for Entering the Password to enter your password Once you have clearance to proceed you can set the alarms 2 Teledyne Analytical Instruments 13 Quickstart Guide Trace Oxygen Analyzer eee ee e Press the Alarm button on the front panel to enter the Alarm function Make sure that AL 1 is blinking AL 1 AL 2 Choose Alarm e Using the lt gt arrow keys to move the blinking over to AL 1 Then press Enter AL 1 1000 ppm HI Dft N Fs N Ltch N Five parameters can be changed on this screen e Value of the alarm setpoint AL 1 ppm oxygen value can be set from 0 00
4. Set Fuse American European Teledyne Analytical Instruments 5 Quickstart Guide Trace Oxygen Analyzer SE e Install 50 Pin Equipment Interface Connector Connect the 50 pin connector to the mating connector on the rear panel e Connect the 9 pin D connector to the RS 232 serial port See Section 3 3 2 3 in the Instruction Manual for information on setting up serial communication for this instrument Install the Micro fuel Cell The Model 3000TA XL EU can be equipped with either the standard B 2CXL Micro fuel Cell or as an option Teledyne s Insta Trace cell B 2CXL Micro fuel Cell To install this cell 1 Remove power to the instrument 2 Open the front panel door 3 With one hand placed underneath the cell block ready to catch the Micro Fuel cell lift up on the stainless steel gate in front of the cell block This releases the cell and cell holder from the block The cell and holder will fall out in your hand CAUTION THE CELL IS SHIPPED SEPARATELY INSIDE TWO BAGS FILLED WITH O Ring OXYGEN FREE INERT GAS USE SS Dog CARE TO AVOID EXPOSING THE o Gall Holder CELLTO AIR FOR ANY LONGER THEN NECESSARY TO INSTALL THE ITEM AL Cell Block Micro fuel Cell CC Cell Adaptor Insta Trace Micro fuel Cell Note The Insta Trace Micro fuel Cell has a short recovery time after ambient air exposure however minimizing this exposure still reduces the recovery time necessary CAUTION DO NOT TOUCH
5. The lt gt arrow buttons select options from the menu currently being displayed on the display When selected the option blinks When the selected option includes a modifiable item the A V arrow buttons can be used to increment or decrement that modifiable item The Enter button is used to accept any new entries on the VFD screen The Escape button is used to abort any new entries on the VFD screen that are not yet accepted by use of the Enter button Teledyne Analytical Instruments 8 Model 3000 TA XL EU Quickstart Guide Available Functions The six function buttons are used to control the analyzer Analyze Analyze oxygen content of sample System Perform system related tasks Span Span calibration Zero For Default Values Zero calibration Range Select the instrument analysis range Alarms Set the alarm setpoints and attributes Perform Oxygen Analysis ol he Sample TRAKHLD 7 Set Instrument Span Perform Self Diagnostic Test Set Instrument Zero Initiate Automatic Calibration Set Alarm Setpoints Define Analysis Confrigure Mode Ranges of Alarm Set Password Operation Logout R Show Negative Teledyne Analytical Instruments 9 Quickstart Guide Trace Oxygen Analyzer Any function can be selected at any time by pressing the appropriate button unless password restrictions a
6. password protection press Enter to accept TETAI as the default password If a password has been previously installed enter the password using the Teledyne Analytical Instruments 10 Model 3000 TA XL EU Quickstart Guide lt gt arrow keys to scroll back and forth between letters and the A V arrow keys to change the letters to the proper password e Press Enter to enter the password Change Password lt ENT gt Yes lt ESC gt No e Press Escape Calibration of the Analyzer For trace analysis the analyzer must be purged before calibration Refer to the Instruction manual for purging procedure Zero Calibration Make sure an appropriate zero gas is connected to the sample port for this procedure Auto Mode Zero Calibration e Press Zero to enter the zero function mode Use the A V arrow keys to toggle between AUTO and MAN zero settling Stop when AUTO appears blinking Zero Settling AUTO lt ENT gt To Begin e Press Enter to begin zeroing PPM Zero Slope ppm s HHH PPM Zero 4 Left ppmis Teledyne Analytical Instruments 11 Quickstart Guide Trace Oxygen Analyzer eee ee The zeroing process will automatically conclude when the output is within the acceptable range for a good zero Then the analyzer automatically returns to the Analyze mode Manual Mode Zeroing e Press Zero to enter the Zero function e Use the A VW keys to toggle between AUTO and MAN zero settling Stop when MAN
7. 0 ppm since it is lower than range 2 Fixed Range or Autoranging Analysis To switch from autoranging to fixed range analysis e Enter the range function by pressing the Range button e Use the lt P arrow keys to move the blinking over AUTO e Use the A V arrow keys to switch from AUTO to FX LO FX MED or FX HI to set the instrument on the desired fixed range low medium or high L 1 M 10 H 100 Mode FX LO L 1 M 10 H 100 Mode FX MED L 1 M 10 H 100 Mode FX HI Press Escape to re enter the analyze mode using the fixed range The Analyze Function Normally all of the functions automatically switch back to the Analyze function when they have completed their assigned operations Pressing the Escape button in many cases also switches the analyzer back to the Analyze function Alternatively you can press the Analyze button at any time to return to analyzing your sample Teledyne Analytical Instruments 15
8. THE SENSING SURFACE OF THE CELL IT IS COVERED WITH A DELICATE TEFLON MEMBRANE THAT CAN LEAK WHEN VAN PUNCTURED Teledyne Analytical Instruments 6 Model 3000 TA XL EU Quickstart Guide ES 1 Place the cell on the holder with the screen side facing down Note There is a small location hole drilled in the holder This hole mates with a guide pin on the bottom rear of the cell block The hole in the cell block holder must align with the guide pin on the cell block 2 Remove power from the instrument 3 Remove the old sensor if installed Discard in accordance with all Federal State Local or other regulations which may apply 4 Purge the analyzer at approximately 1 SCFH flow rate with nitrogen or applicable sample gas with the sensor holder removed 5 Remove the new sensor from its double bag storage Lift Up 6 Remove the sensor shorting button Va Cell Block A TOP d 7 Place the sensor inside the cell block Concentric SCH 5 Shorting i Foil Contact Gate e 8 Hold the sensor up into the block while a an gt Micro tuel La e EST rag Protective cet ti positioning the cap under the sensor Surface FiimSeai Protecto e GED over Vigorously push the cell holder with the D pad sensor into the cell block thus puncturing BOTIOM Pin s oo A nee Ce the protective film seal cover S 7 Holder 9 Push the gate on the cell block down so that the slots on the side of t
9. appears blinking on the display Zero Settling Man lt ENT gt To Begin e Press Enter to begin the zero calibration AHHH ppm Zero Slope ppm s Once zero settling is completed the instrument automatically returns to the Analyze mode Span Calibration Make sure an appropriate span gas is connected to the sample port Auto Mode Spanning e Press Span to enter the span function e Use the arrow keys to toggle between AUTO and MAN span settling Stop when AUTO appears blinking on the display Span Settling AUTO lt ENT gt For Next e Press Enter Calib Holding time Cal hold 5 min e Press Enter to move to the next screen Span Val 000008 00 lt ENT gt Span lt UP gt Mod e Use the AV arrow keys to enter the oxygen concentration mode The lt P arrows choose the digit and the A V arrows choose the value of the digit When you have finished typing in the concentration of the span gas you are using press Enter to begin the span calibration Teledyne Analytical Instruments 12 Model 3000 TA XL EU Quickstart Guide ppm Span Slope ppmis The instrument automatically returns to the Analyze mode at the conclusion of the auto span cycle Manual Mode Spanning e Press Span to start the Span function Span Settling MAN lt ENT gt For Next e Use the AV keys to toggle between AUTO and MAN span settling Stop when MAN appears blinking on the display Press Enter to move to the next screen
10. arate dedicated range relay contacts Low Medium High Cal e Network I O Serial digital communications for local network access For future expansion Not implemented at this printing Teledyne Analytical Instruments 3 Quickstart Guide Trace Oxygen Analyzer EE E S ee EE SETUP AND INSTALL Mount the Analyzer The Model 3000TA EU is for indoor use in a general purpose area It is NOT for hazardous environments of any type It is designed for flush panel mounting Use the four mounting holes one in each corner of the rigid frame to panel mount the instrument Make Gas Connections Note Do not remove plastic caps on VCR fittings unless you are ready to make connections The analyzer is equipped with 1 4 inch tube fittings and 6 mm adapters are supplied for metric system installations 1 Connect your sample gas to the SAMPLE IN port 2 Connect a vent line to EXHAUST OUT port 3 Calibration gases should be tee d into the sample inlet with appropriate valves 4 Regulate the sample gas pressure between 2 and 50 psig sufficient to keep the front panel flowmeter reading in an acceptable range 0 5 to 2 0 SLPM For non pressurized sample or very low pressure less than 2 psig vacuum service plumbing is recommended 5 If greater sample flow is required for improved response time install a bypass in the sampling system upstream of the analyzer input 6 For optional vacuum application where the sample pressure
11. eys Six touch sensitive membrane switches are used to change the specific function performed by the analyzer e Analyze Perform analysis for oxygen content of a sample gas e System Perform system related tasks described in detail in chapter 4 Operation e Span Span calibrate the analyzer e Zero Zero calibrate the analyzer e Alarms Set the alarm setpoints and attributes e Range Set up the 3 user definable ranges for the instrument Data Entry Keys Six touch sensitive membrane switches are used to input data to the instrument via the alphanumeric VFD display e Left amp Right Arrows Select between functions currently displayed on the VFD screen e Up amp Down Arrows Increment or decrement values of functions currently displayed e Enter Advances VFD display to the next screen in a series or returns to the Analyze screen if none remain e Escape Backs VFD display to the previous screen in a series or returns to the Analyze screen if none remain Digital Meter Display The meter display is a Light Emitting Diode LED device that produces large bright 7 segment numbers that are legible in any lighting It produces a continuous readout from 0 10 000 ppm and then switches to a continuous percent readout from 1 25 Alphanumeric Interface Screen The VFD screen displays values options and messages for immediate feedback Set Flow Needle valve used to adjust flow of gas sample Flowmeter Monitors the flow of gas
12. he gate engage the locating screws on the side of the block This forces the holder into position and forms a gas tight seal 10 Purge the system using sample or zero gas 11 Power the system back up The Insta Trace sensor will typically reach a stable low value within 30 minutes or less after installation 2 Teledyne Analytical Instruments 7 Quickstart Guide Trace Oxygen Analyzer SE BASIC OPERATION Once the analyzer has been installed it can be configured for your application Prior to using the instrument you must e Calibrate the instrument e Define the analysis ranges and choose whether to use autoranging or a fixed range e Set alarm setpoints and modes of alarm operation Additional configuration parameters are available to tailor the instrument to your particular application Refer to the Instruction Manual for specific information on setting of additional system parameters Default Configuration The default analyzer configuration is as follows Ranges LO 1 ppm MED 10 ppm HI 100 ppm Auto Ranging ON Alarm Relays Defeated 10 00 ppm HI Not failsafe Not latching Zero Auto every 0 days at 0 hours Span Auto at 000 008 00 ppm every 0 days at 0 hours If you choose not to use password protection the default password is automatically displayed on the password screen when you start up and you simply press Enter for access to all functions of the analyzer Using the Data Entry and Function Buttons
13. is at atmospheric or very low pressure the instrument should be fitted with the vacuum service option This option locates the flow control valve on the exhaust side of the Micro fuel Cell Note Exhaust connections must be consistent with the hazard level of the constituent gases Check Local State and Federal laws and ensure that the exhaust stream vents to an appropriately controlled area if required Teledyne Analytical Instruments 4 Model 3000 TA XL EU Quickstart Guide Electrical Connections CAUTION A CAUTION A READ ALL SAFETY INFORMATION REGARDING ELECTRICAL HAZARDS ASSOCIATIED WITH THIS INSTRUMENT BEFORE MAKING ELECTRICAL CONNECTIONS POWER IS APPLIED TO THE INSTRUMENT S CIRCUITRY AS LONG AS THE INSTRUMENT IS CONNECTED TO THE POWER SOURCE THE RED SWITCH ON THE FRONT PANEL IS FOR SWITCHING POWER ON OR OFF TO THE DISPLAYS AND OUTPUTS ONLY Connect primary input power Insert the power cord into the power cord receptacle Install the fuse Fuses are not installed at the factory Be sure to install the proper fuse as part of installation Fuse Block _ Cover Place small screwdriver in notch and pry cover off as shown in the figure To change between American and European fuses remove the single retaining screw flip fuse block over 180 degrees and replace screw Housing Replace fuse as shown below Reassemble Housing Jumper Bar gt J Zoe Fuse Block lt 4 US 4 4 Cover 2
14. past the sensor Readout is 0 2 to 2 4 SLPM of nitrogen Standby Button The Standby turns off the display and outputs but circuitry is still operating Access Door For access to the Micro fuel Cell the front panel swings open when the latch in the upper right corner of the panel is pressed all the way in Teledyne Analytical Instruments 2 Model 3000 TA XL EU Quickstart Guide Rear Panel Equipment Interface At the rear panel you make the gas and electrical e Teledyne Analytical Instruments BR o S connections to the instrument SES Power Connection Universal AC power source Gas Inlet and Outlet One inlet and one e exhaust out mom SAMPLEIN SPANIN ae SEE MANUAL FOR INTERCONNECTION DETAIL C EXHAUST OUT o o RS 232 Port Serial digital concentration signal output and control input Equipment Interface Connector Interconnections for analyzer functions including e Analog Outputs 0 1 VDC oxygen concentration plus 0 1 VDC range ID and isolated 4 20 mA DC oxygen concentration plus 4 20 mA DC range ID e Alarm Connections 2 concentration alarms and system alarm e Remote Probe Used in the 3000TA EU for controlling external solenoid valves only e Remote Span Zero Digital inputs allow external control of analyzer calibration e Calibration Contact To notify external equipment that instrument is being calibrated and readings are not monitoring sample e Range ID Contacts Four sep
15. pply Password Protection If a password is assigned then setting the following system parameters can be done only after the password is entered span and zero settings alarm setpoints analysis range definitions switching between autoranging and manual override setting up an auto cal and assigning a new password However the instrument can still be used for analysis or for initiating a self test without entering the password If you have decided not to employ password security use the default password TETAI This password will be displayed automatically by the microprocessor The operator just presses the Enter key to be allowed total access to the instrument s features Note If you use password security it is advisable to keep a copy of the password in a separate safe location Entering the Password To install a new password or change a previously installed password you must key in and Enter the old password first If the default password is in effect pressing the Enter button will enter the default TETAI password for you e Press System TRAK HLD Auto Cal PSWD Logout More e Use the lt gt arrow keys to scroll the blinking over to PSWD e Press Enter to select the password function Either the default TETAI password or AAAAA place holders for an existing password will appear on screen depending on whether or not a password has been previously installed TETAI Enter PWD AAAAA Enter PWD e Ifyou are not using