Teledyne 4060 User's Manual

image

Contents

1. ITS AFFILIATES AND AGENTS FOR DAMAGE OR INJURY RESULTING FROM MISUSE OR NEGLECT OF THIS INSTRUMENT IS IMPLIED OR ASSUMED MISUSE OF THIS PRODUCT IN ANY MANNER TAMPERING WITH ITS COMPONENTS OR UNAUTHORIZED SUBSTITUTION OF ANY COMPONENT MAY ADVERSELY AFFECT THE SAFETY OF THIS INSTRUMENT WHEN OPERATING THIS INSTRUMENT THE DOORS MUST BE CLOSED AND ALL COVERS SECURELY FASTENED THE GAUGES MUST BE IN PROPER WORKING ORDER DO NOT OVERPRESSURIZE THE SYSTEM READ THIS MANUAL BEFORE OPERATING THE INSTRUMENT AND ADHERE TO ALL WARNINGS INCLUDED IN THIS MANUAL j Teledyne Analytical Instruments Series 4060 Table of Contents Safely Messages iiinis onoarei Additional Safety Information eeeeeeeeeeeeeeeeeeeees List of PIQUICS vase sans scasccasecsuceassias aaneusedutwecandaaneaabduasetavdeaus Listof FABIO vo icivicicicccinteesiuencudcaventransseadwassvenieenddancvesdvenseans DATO CU CUNO NA EE E ees ceva ss serena cae as E he eens ce 1 1 Main Features of the Analyzer 1 2 Principle of Operation 1 3 Analyzer Description 1 4 Applications Operational THEOL ssciiscrsinsscorsacisseieiniasscdeterieiniannasetacst 2 1 Introduction 2 2 Modes of Operation 2 3 Analyzer Subsystems 2 3 1 Sample System 2 3 2 Gas Flow Control System 2 3 3 Fuel and Blanket Air Systems 2 3 4 Flame lonization Detection Cell 2 4 Detection Cell 2 4 1 Electrometer Amplifier 2 4 2 Anode Power Supply 2 4 3 Flame Guard Circuit 2 4 4 Flame I
2. no unused branch lines should be left capped off where pockets might form of material that is 38 47 Teledyne Analytical Instruments Series 4060 Installation not representative of the current contents of the line or which might keep contaminants from being purged out of the system CAUTION THE GASES USED MUST BE OF THE HIGHEST QUALITY ULTRA ZERO GRADES AS SHOWN Ak BELOW FAILURE TO DO SO WILL RESULT IN CONTAMINATION AND FAILURE TO DETECT LOW PPB BENZENE AIR USE WATER PUMPED AIR WITH THC LESS THAN 0 1 PPM DO NOT USE OIL PUMPED AIR UNDER ANY CIRCUMSTANCES FUEL HYDROGEN GAS 100 ZERO QUALITY WITH THC LESS THAN 0 5 PPM CARRIER GAS NITROGEN GAS ULTRA ZERO GRADE WITH THC LESS THAN 0 05 PPM Normally four supporting gases of different composition see Section 4 1 Equipment will be required to operate the analyzer The recommended composition is specified Appendix B Addendum and Testing Results The gases should be supplied from cylinders that are equipped with the type of regulator specified in the aforementioned sections CAUTION UNDER NO CIRCUMSTANCES SHOULD YOU EMPLOY A REGULATOR THAT IS NOT EQUIPPED A N WITH A METALLIC DIAPHRAGM ANYWHERE IN THE SYSTEM The regulators should be inspected prior to installation to be sure that they are oil free Failure to comply with these directives will result in a constant drift in analyzer output as organic compounds will outgas into the plumbing system at a rate t
3. 00ppb R2 0 1 00ppm R3 0 10 00ppm The value of the upper limit of the currently selected range AUTO or MANUAL affects the voltage and current of the analog outputs on the rear of the analyzer as well as contact closures indicating which range is current The analog outputs from the 50 pin Equipment connector see Section 3 3 2 4 and Table 3 1 represent the proportion of the analysis concentration to the currently selected range limit MANUAL AUTO RANGE SELECT In Manual Range Select the range indicated on the second line Man Rng is maintained as the current range of operation In Auto Range select the software determines the smallest range whose limit is larger than the analysis concentration Automatic Range selection in Auto Range is governed by hysteresis such that the concentration must fall below 90 of the limit of the next smaller range before the current range will be set to the lower range RANGE LIMITS Ranges may be set as low as 100 0 ppb and as high as 100 0 ppm Range 3 can only be set at a value greater than Range 2 Range 2 can only be set at a value greater than Range 1 4 6 11 Analog Output Adjustment The software in this instrument provides a way to enter to manage the analog output of the analyzer To access the offset function lt UP DOWN gt From the MAIN MENU scroll to the ANALOG ADJUST function using the UP DOWN keys lt Enter gt Pressing lt Enter gt activates the function and takes you t
4. 1 ID Contact 38 Range 1 ID Contact 22 Range 2 ID Contact 39 Range 2 ID Contact 19 Range 3 ID Contact 18 Range 3 ID Contact 34 Not Used 35 Not Used 3 3 2 8 NETWORK I O A serial digital input output for local network protocol At this printing this port is not yet functional It is to be used in future options to the instrument Pins 13 and 29 3 3 2 9 PINOUT TABLE The following table summarizes all the outputs inputs available in the 50 pin D Sub connector on the back panel of the analyzer Teledyne Analytical Instruments 35 Installation Table 3 7 Pin out of 50 pin D Sub Connector Series 4060 pin Description pin Description 1 26 2 27 3 Output 4 20 ma Channel 2 28 Alarm 1 C Contact 4 Output 4 20 ma Channel 2 29 5 Output 4 20 ma Channel 1 30 6 Output 4 20 ma Channel 1 31 7 Output 0 1 v Channel 1 32 Exhaust Solenoid Hot 8 Output 0 1 v Channel 2 33 Sample Solenoid Hot 9 34 Range 4 Contact not used 10 Remote Span 35 Range 4 Contact not used 11 36 Alarm 3 NC Contact 12 Remote Span 37 Alarm 3 NO Contact 13 38 Range 1 Contact 14 39 Range 2 Contact 15 40 Calibration Contact 16 Span Solenoid Return 41 Calibration Contact 17 Span Solenoid Hot 42 Alarm 2 NC Contact 18 Range 3 Contact 43 Alarm 2 NO Contact 19 Range 3 Contact 44 Alarm
5. 2 ENTER 4 6 3 3 ESCAPE 4 6 4 Menu Structure 4 6 4 1 Main Menus 4 6 5 Span 4 6 6 ALT SPAN 4 6 7 The Model Screen 4 6 8 System Self Diagnostic Test 4 6 9 The Alarms Function 4 6 10 The Range Function 4 6 11 Analog Output Adjustment 4 6 12 Linearization 4 6 13 Changing Stream 4 6 14 Setting up an AUTO CAL 4 6 15 Timing 4 6 16 Group Setup 4 6 17 Password Protection 4 6 18 Logging Out 4 6 19 Standby 5 1 Measuring Circuit Electrical Checks 5 1 1 Anode Voltage Check 5 1 2 Electronic Stability 5 1 3 Printed Circuit Board Replacement Teledyne Analytical Instruments 44 44 46 46 47 47 47 48 48 49 50 51 51 51 52 55 55 56 56 56 58 58 58 61 62 sisvuonvieue 65 66 66 67 67 Xi Series 4060 5 1 4 Collector Cable 5 2 Temperature Control Electronic Check 5 3 Ignition and or Flame Guard Circuit Checks 5 4 Sampling System 5 5 Printed Circuit Board Descriptions 5 5 1 Flame Guard and Anode Power Supply PCB 5 5 2 Proportional Temperature Controller PCB 5 5 3 Electrometer Amplifier PCB AppendiX wisicceseiccseesscsdcendassseuacewcisentsendsendsacdeuedsandeandanadeandeasins A 1 Specifications and Initial Settings A 2 Recommended Spare Parts List A 3 Drawing List Appendix B sevaccia cccntva ceca ncwanewandvecastenduacecandvaceus neveneventvanevendvens B1 Addendum and Testing Results xii Teledyne Analytical Instruments 68 68 69 70 71 71 72 73 75 75 76 77 79 Series 4060
6. ALT SPAN If a particular compound of interest is not contained in the span gas another compound existing in the span gas can be used for the alternate calibration 4 6 7 The Model Screen The MODEL screen displays the model and software version information It is accessed via the MAIN MENU by scrolling UP DOWN gt to MODEL and pressing lt Enter gt 4 6 8 System Self Diagnostic Test The Model 4060 has a built in self diagnostic testing routine Preprogramming signals are sent through the power supply output board preamp board and sensor circuit The return signal is analyzed and at the end of the test the status of each function is displayed on the screen either as GOOD or BAD If any of the functions fail the System Alarm is tripped Note The self diagnostics are run automatically by the analyzer whenever the instrument is turned on but the test can also be run by the operator at will Note The self diagnostics will interrupt analysis temporarily Teledyne Analytical Instruments 51 Operation Series 4060 To initiate a self test lt UP DOWN gt From the MAIN MENU scroll to the SELF TEST function lt Enter gt Activate the SELF TEST function by pressing lt Enter gt This brings up the SELF TEST initialization screen Begin Self Test ENTER Yes ESCAPE NO lt Enter or Escape gt Start the diagnostic testing routine by pressing lt Enter gt or cancel out by pressing lt Escape gt If you p
7. List of Figures pauc Figure 1 1 Model 4060 Front Panel Interface cceeeeeeeee 17 Figure 1 2 Model 4060 Rear Panel ecceeeeeeeeeeeeeeeneeees 17 Figure 2 1 Internal Temperature Controllers ccceeeceeeeee 21 Figure 2 2 Typical Piping Diagram for the Model 4060 23 Figure 3 1 Model 4060 Rear Panel with Optional Gas Manifold 29 Figure 3 2 Equipment Interface Connector Pin Arrangement 30 47 Teledyne Analytical Instruments xiii Series 4060 List of Tables Table 3 1 Analog Output Connections cseeeeeeeeeeeeeeeeeees 31 Table 3 2 Analog Concentration Output Exampple 00 31 Table 3 3 Analog Range ID Output Example eee 32 Table 3 4 Alarm Relay Contact Pins sseeeeeeeeeeeeeeeeeteees 33 Table 3 5 Remote Calibration Connections cccececeeeees 34 Table 3 6 Range ID Relay Connections ccceeeeeeeeeeeeeteees 35 Table 3 7 Pin out of 50 pin D Sub Connectol seeeeeeeee 36 Table 3 8 Commands via RS 232 Input ceeeeeeeeeeeeeeeteeees 37 Table 3 9 Required RS 232 Options ecceseeeeeeeeeeeeeeeeeeeeeees 37 xiv Teledyne Analytical Instruments Series 4060 Introduction Introduction rpm e Teledyne Analytical Instruments Series 4060 Trace Aromatic Hydrocarbon Analyzer is a versatile instrument designed to measu
8. PERFORMED BY AUTHORIZED AND TRAINED PERSONNEL ONLY BEFORE STARTING ANY OF THESE MAINTENANCE AND TROUBLESHOOTING PROCEDURES READ THE CAUTIONS AND WARNINGS INCLUDED IN THE SECTION TITLED ADDITIONAL SAFETY WARNINGS PAY SPECIFIC ATTENTION TO THE PROCEDURES FOR REMOVAL OF INTERNAL INACCESSIBLE SHOCK HAZARDS IF THE INSTRUMENT MUST BE TURNED ON DURING ANY OF THESE MAINTENANCE AND TROUBLESHOOTING PROCEDURES BE CAREFUL AND WORK WITH THE ONE HAND RULE Work with one hand only Keep the other hand free without contacting any other object This reduces the possibility of a ground path through the body in case of accidental contact with hazardous voltages MANY OF THE ELECTRICAL PARTS WITHIN THE ANALYZER ARE SUSCEPTIBLE TO DAMAGE FROM ELECTROSTATIC DISCHARGE ESD USE ESD SAFE PROCEDURES WHEN HANDLING OR WORKING WITH ELECTRONIC COMPONENTS If the analyzer is suspected of incorrect operation always evaluate performance with zero or span gas flowing in the sample path Never 7 Teledyne Analytical Instruments 65 Maintenance Series 4060 attempt to evaluate performance on sample gas If analyzer sensitivity is questionable use the span gas For all other evaluations use the zero gas and low range for maximum sensitivity The important consideration is to control as many variables as possible Using cylinder supplied gases of known hydrocarbon content eliminates the possibility of introducing an unknown variable Do not overl
9. Pressing lt Enter gt will logout the current user and protect the system from unauthorized changes to parameters If user has LOGGED OUT then only the following SUB MENU procedures may be executed 1 PASSWORD 2 LOGOUT which only repeats the logout 3 MODEL Note however that the instrument can still be used for analysis without entering the password To defeat security the password must be entered 4 6 19 Standby This function allows you to place the instrument in STANDBY CAUTION STANDBY SHUTS DOWN POWER TO THE DISPLAYS ONLY INTERNAL CIRCUITS ARE STILL ENERGIZED i AND ELECTRICAL SHOCK HAZARD STILL EXISTS To place the instrument in STANDBY status 62 Teledyne Analytical Instruments Series 4060 Operation lt UP DOWN gt From the MAIN MENU scroll to the STANDBY function using the UP DOWN keys lt Enter gt Pressing lt Enter gt places the instrument in STANDBY To exit STANDBY scroll again to the STANDBY function and press lt Enter gt again 4 Teledyne Analytical Instruments 63 Operation Series 4060 64 Teledyne Analytical Instruments Series 4060 Maintenance Maintenance amp Troubleshooting WARNING A A CAUTION A DANGEROUS HIGH VOLTAGES EXIST INSIDE THIS INSTRUMENT THERE ARE NO USER SERVICEABLE PARTS WITHIN THE COVER ON THE INSIDE OF THE DOOR INSIDE THE ISOTHERMAL CHAMBER SAMPLE SYSTEM AND ON THE ELECTROMETER AMPLIFIER PC BOARD WORK IN THESE AREAS MUST BE
10. an alternate span calibration MODEL Displays Manufacturer Model and Software version of the instrument SELF TEST The instrument performs a self diagnostic routine to check the integrity of the power supply output boards cell and amplifiers ALARMS Used to set the alarm setpoints and determine whether each alarm will be active or defeated HI or LO acting and failsafe or not RANGE Used to set up three analysis ranges that can be switched manually ANALOG OUT ADJUST Adjust the analog output with offset and scaling LINEARIZATION Linearization option CHANGE STREAM optional feature Controls a relay switch for using alternate gases Has no effect during span mode span gas relay setting used at that time AUTO CAL Used to define and or start an automatic calibration sequence AUTOCAL is an optional feature not included in the standard configurations of the 4060 TIMING Low level application specific timing parameters Factory set Do not change these Teledyne Analytical Instruments 49 Operation Series 4060 e GROUP SETUP Determines compound names associated timing and measurement ranges Do not change these e PSWD Used to establish password protection or change the existing password e LOGOUT Logging out prevents unauthorized tampering with the analyzer settings e STANDBY Removes power to outputs and displays but maintains power to internal circuitry Any function can be selected
11. familiar with the operating characteristics of this system before starting the analyzer for the first time The Addendum and Testing Results section of Appendix B lists the software revision and default settings for your specific system 4 1 Equipment The following supporting gases and hardware will be required to operate the standard analyzer 1 Fuel A cylinder containing a hydrogen gas zero gas quality composition will be required to supply the fuel for the flame ionization burner The cylinder is to be equipped with an oil free metallic diaphragm regulator dual stage 2 Blanket Air A cylinder of compressed air zero gas quality will be required to maintain the proper atmosphere within the cell The cylinder is to be equipped with an oil free dual stage metallic diaphragm regulator 3 Carrier Gas A cylinder of nitrogen gas zero gas quality equipped with dual stage metallic diaphragm regulator is required 4 Span Gas A cylinder or a permeation device system capable of generating known concentration of benzene and or other aromatic hydrocarbons of interest will be required to standardize the analyzer 5 Sample Pressure Regulation An oil free metallic diaphragm regulator must be installed at the sample point when possible see Section 3 3 3 Gas Connections Teledyne Analytical Instruments 41 Operation Series 4060 CAUTION A THE GASES USED MUST BE OF THE HIGHEST QUALITY ULTRA ZERO GRADES A
12. integrated circuit technology The individual circuits which are required to process the incoming signal and condition it to provide the various outputs alarms indicators etc 5 5 1 Flame Guard and Anode Power Supply PCB Schematic No B 74672 Assembly Dwg No B 74671 Anode Power Supply The high voltage anode power supply components are mounted on the flame guard and anode power supply printed circuit board High voltage regulation is achieved through the use of zener diodes The simplicity of this circuit s design can be attributed to the extremely low current demand of the anode circuit The positive output voltage is nominally 125 volts Output tolerance is 10 volts from the specified 250 volts due to variation in components from unit to unit Flame Guard Circuit A thermistor controlled comparator circuit is employed to operate relays in the event of a flame out condition A panel indicator light is turned on by the relay to alarm personnel that a flame out condition has occurred The controlling thermistor is located within the upper section of the cell assembly The electronic circuit components and relays are mounted on the same printed circuit board as the anode power supply the indicator light on the control panel The thermistor is located in the circuit so that it controls the input of comparator The circuit is factory set so that with the flame burning the output of comparator is low The microprocessor senses the l
13. minute using the Front Panel flow control valve clockwise increases flow See Figure 1 1 4 6 Analyzer Operation Although the Model 4060 has been programmed for your application at the factory it can be further configured at the operator level Depending on the specifics of the application this might include all or a set of the following procedures 44 Teledyne Analytical Instruments Series 4060 Operation 1 Setting system parameters Establish a security password if desired requiring operator to log in Establish and start an automatic calibration cycle if equipped with the optional autocal module 2 Routine operation Calibrate the instrument Choose autoranging or select a fixed range of analysis Set alarm setpoints and modes of alarm operation 3 Special functions setup Calibrate analog output select analog output source Procedures for accessing and or changing parameters as well as analyzer operation are detailed in the sections to follow In general the sequence of menus available on screen follows a logical course for setup and operation It is not required however to follow this sequential path The user could for instance go directly to set an analysis range and then program an offset to the current output for matching a range on the user s recording device The only exception to this is when the instrument is powered up It will go through a warm up period followed by a diagnostic self t
14. must be taken such as correcting the alarm or the analysis concentration If an active not defeated alarm has been set to HIGH at 20 0 ppb and the analysis concentration is above that level then the alarm condition is occurring DEFEATED If an alarm is defeated its relay is de energized regardless of failsafe condition A defeated alarm does not react to a transition over its trip point in either direction HIGH If an alarm is set as HIGH it will not create a new alarm condition see latching if the analysis concentration is below the trip point if the analysis concentration is above the trip point then an alarm condition will be created or maintained FAILSAFE A non defeated alarm that is in FAILSAFE mode energizes an alarm relay in a non alarm condition and de energizes an alarm relay in an alarm condition Note Failsafe condition of an alarm is in software This is not related to relays that have both normally open and normally closed terminals 4 Teledyne Analytical Instruments 53 Operation Series 4060 LATCHING The latching property configures the alarm such that the user must manually relieve the alarm condition even though the concentration no longer violates the trip point of the alarm So if an alarm is NON LATCHING and the analysis concentration temporarily drifts above the trip point of a HIGH alarm the alarm condition occurs only during the time the concentration is above the trip point If that al
15. of less than 0 5 ppm and supplied at a pressure of 40 psig The compressed air ultra zero gas quality with THC less than 0 1 ppm should be used and supplied at a pressure of 40 psig Connect the fuel and air sources to the instrument according to the gas connection diagram included at the back of this manual 3 3 3 4 SAMPLE AND SPAN GAS CONNECTIONS The sample and span gas connections are made at the rear panel If the optional autocal module is installed the sample and span gas will connect to this module If no autocal module is present these gases connect to the labeled fittings on the rear panel Set the supply pressure for sample and span gas to 20 psig 3 4 Placing the System in Operation See Section 4 for information on starting the analyzer for the first time Makes sure that all electrical connections have been made correctly and all connectors are fully seated Make sure all gas connections are correct and leak free 40 Teledyne Analytical Instruments Series 4060 Operation Operation This section of the manual describes how to setup and operate the Model 4060 Analyzer Sections 4 1 through 4 5 describe preliminary steps and equipment needed to operate the analyzer Beginning with Section 4 6 the actual operation of the analyzer is described along with descriptions of the display prompts messages and options available to the user within a menu or sub menu You should read this chapter in its entirety and become
16. 0 0 6 13 6 70 0 7 15 2 80 0 8 16 8 90 0 9 18 4 100 1 0 20 0 Table 3 3 Analog Range ID Output Example Range Voltage Signal Current Signal Application Output VDC Output mA DC Range 1 0 20 7 2 0 100 ppb Benzene Range 2 0 50 12 0 1 pom Benzene Range 3 0 80 16 8 0 10 ppm Benzene 3 3 2 5 ALARM RELAYS The nine alarm circuit connector pins connect to the internal alarm relay contacts Each set of three pins provides one set of Form C relay contacts Each relay has both normally open and normally closed contact connections The contact connections are shown in Table 3 4 They are capable of switching up to 3 amperes at 250 VAC into a resistive load The connectors are Threshold Alarm 1 e Can be configured as high actuates when concentration is above threshold or low actuates when concentration is below threshold e Can be configured as failsafe or non failsafe e Can be configured as non latching e Can be configured out defeated 32 Teledyne Analytical Instruments Series 4060 Installation Threshold Alarm 2 e Can be configured as high actuates when concentration is above threshold or low actuates when concentration is below threshold e Can be configured as failsafe or non failsafe e Can be configured as non latching e Can be configured out defeated System Alarm e Actuates when DC power supplied to circuits is unacceptable in one or more parameters Permanently configured as failsafe and l
17. 2 C Contact 20 Alarm 3 C Contact 45 Alarm 1 NC Contact 21 Range 1 Contact 46 Alarm 1 NO Contact 22 Range 2 Contact 47 23 Output 0 1 v Channel 2 48 Exhaust Solenoid Return 24 Output 0 1 v Channel 1 49 25 50 Sample Solenoid Return 3 3 2 10 RS 232 PORT The digital signal output is a standard RS 232 serial communications port used to connect the analyzer to a computer terminal or other digital device It requires a standard 9 pin D connector Input The input functions using RS 232 that have been implemented to date are described in Table 3 8 36 Teledyne Analytical Instruments Series 4060 Installation ee ee i a Table 3 8 Commands via RS 232 Input Command Description AS lt enter gt Immediately starts an autospan AL lt enter gt Immediately revert to Analyze CH4 Mode RL lt enter gt Change to Manual Range LOW RM lt enter gt Change to Manual Range MEDIUM RH lt enter gt Change to Manual Range HIGH RA lt enter gt Change to Manual Range AUTO Implementation The RS 232 protocol allows some flexibility in its implementation Table 3 9 lists certain RS 232 values that are required by the Model 4060 implementation Table 3 9 Required RS 232 Options Parameter Setting Baud 2400 Byte 8 bits Parity none Stop Bits 1 Message Interval Sent at the end of each cycle 3 3 3 Gas Connections The analyzer gas connection di
18. ARD CONTAIN DANGEROUSLY HIGH VOLTAGE SUFFICIENT TO CAUSE SERIOUS INJURY OR DEATH There are the following three types of inaccessible shock hazards within the Analyzer 1 Line voltages and line related voltages such as 115 VAC which exists within the 230 VAC versions as well These voltages stop when the Analyzer is turned off and the mains line cord is removed from the instrument 2 The sensor anode supply voltage approximately 250 VDC This voltage exists on the Flame Guard anode power supply PCB the motherboard and the anode igniter terminals on the sensor THIS VOLTAGE WILL REMAIN HAZARDOUS FOR MANY MINUTES AFTER THE ANALYZER HAS BEEN TURNED OFF j Teledyne Analytical Instruments Series 4060 3 External hazardous voltages which may be connected to the Analyzer alarm relay connections Procedure for Removal of Internal Inaccessible Shock Hazards CAUTION SERVICING OR MAINTENANCE OF THE ANALYZER SHOULD ONLY BE DONE BY SUITABLE TRAINED AN VAN PERSONNEL TO AVOID THESE INACCESSIBLE HAZARDOUS VOLTAGES WHEN SERVICING THE SERIES 4060 PERFORM EACH OF THE FOLLOWING STEPS IN THE ORDER GIVEN BEFORE SERVICING BEGINS 1 Switch off the power to the Analyzer and remove the main line power cord from the Analyzer 2 Remove all external voltages from the connections to the alarm contacts 3 Wait one minute 4 Discharge the anode supply voltage a Connect one end of an insulated to 1000 VDC or more c
19. CREEN Reenter a new Password A A A Note that the new password has been replaced by A as placeholder characters This is to ensure that the wrong password is not mistakenly entered lt UP DOWN gt Use the UP DOWN keys to reenter the letters of the new password lt Enter gt Press lt Enter gt to advance to the next letter lt Enter gt If the repeated password matches the previously entered new password the new password is set the 4060 resumes the ANALYSIS SCREEN after displaying a brief message Password Changed lt Escape gt Steps back to the previously entered letter or if on the first letter returns to the CHANGE PASSWORD menu Note If you log off the system using the LOGOUT function in the MAIN MENU you will now be required to reenter the password to gain access to most menus 4 6 18 Logging Out The LOGOUT function provides a convenient means of leaving the analyzer in a password protected mode without having to shut the Teledyne Analytical Instruments 61 Operation Series 4060 instrument off By entering LOGOUT you effectively log off the instrument leaving the system parameters protected until the password is reentered The system will continue analysis however To log out lt UP DOWN gt From the MAIN MENU scroll to field of LOGOUT function lt Enter gt Press lt Enter gt to logout The screen will display the message Restrict Access ENTER Yes ESCAPE NO
20. INSTRUCTION OPERATING AND MAINTENANCE MANUAL FOR SERIES 4060 P N M76417 DATE 06 29 10 A mer Toxic and or flammable gases or liquids may be present in this monitoring system Personal protective equipment may be required when servicing this instrument Hazardous voltages exist on certain components internally which may persist for a time even after the power is turned off and disconnected Only authorized personnel should conduct maintenance and or servicing Before conducting any maintenance or servicing consult with authorized supervisor manager Series 4060 Copyright 2010 Teledyne Analytical Instruments All Rights Reserved No part of this manual may be reproduced transmitted transcribed stored in a retrieval system or translated into any other language or computer language in whole or in part in any form or by any means whether it be electronic mechanical magnetic optical manual or otherwise without the prior written consent of Teledyne Analytical Instruments 16830 Chestnut Street City of Industry CA 91749 1580 Warranty This equipment is sold subject to the mutual agreement that it is warranted by us free from defects of material and of construction and that our liability shall be limited to replacing or repairing at our factory without charge except for transportation or at customer plant at our option any material or construction in which defects become apparent within one yea
21. Inthe ANALYSIS SCREEN the ARROW KEYS cause entry into the MAIN MENU 2 When the selected option is a function on the MAIN MENU or any SUB MENU screen the ARROW KEYS move to the next lower or upper menu 3 Ifthe selected option is a MODIFIABLE ITEM value is flashing The ARROW KEYS increment or decrement numeric values or toggle ON OFF YES NO or ENABLE DISABLE type values 4 The arrow keys when pressed simultaneously are used to manually ignite the flame after a flame out condition 4 6 3 2 ENTER The ENTER key is used in several context sensitive ways Teledyne Analytical Instruments 47 Operation Series 4060 1 When the selected option is a function on the MAIN MENU or any SUB MENU screen the function name appears with an arrow next to it In some cases the item in the menu is the parent of another SUB MENU in other cases the item in the menu is the parent of a MODIFIABLE ITEM If the selected option is a MODIFIABLE ITEM the ARROW KEYS are used to modify the value of the item A modifiable item is flashing The ENTER key is then used to accept the value and move you to the next field to continue programming 4 6 3 3 ESCAPE The ESCAPE key is used in several context sensitive ways 1 2 When displaying the analysis mode the ESCAPE key temporarily clears any present alarms However if the alarm condition is still present the alarm will re occur when re detected Also pressing the ESCAPE k
22. N LATCHING Auto Span Timing Defeated every 7 days at 12 hours Span 80 ppb Password TAI 4 6 2 Style Conventions The following typeface conventions are used when referring to screen names key presses and screen readout Screens Arial 12 pt type in capital letters Example ANALYZE or MAIN screen or menu Key Presses lt key gt The particular keystroke to enter is placed between lt and gt Example lt enter gt or lt escape gt or lt A gt UP key or lt Y gt DOWN key Only when the keystroke is to be entered will it be placed between the brackets If discussing a 46 Teledyne Analytical Instruments Series 4060 Operation particular key it will be typed as text using all caps Example this is the ENTER key Screen Modes Times New Roman 12 pt italic Example Analysis Mode or Setup Mode Screen Readout Arial Narrow 12 pt bold Example AUTOCAL 4 6 3 Navigation and Data Entry Note All menus time out after 15 fifteen seconds elapse with no button presses the analyzer returns to the ANALYSIS SCREEN if parameters have been altered but not saved with the ENTER key the alterations are lost Navigation and Data Entry is possible using 2 ARROW KEYS the ENTER key and the ESCAPE key It is important to read and understand the MENU STRUCTURE section to fully understand navigation and data entry 4 6 3 1 ARROW KEYS Pressing the ARROW KEYS select menus and modifies values 1
23. S SHOWN BELOW FAILURE TO DO SO WILL RESULT IN CONTAMINATION AND FAILURE TO DETECT LOW PPB BENZENE AIR USE WATER PUMPED AIR WITH THC LESS THAN 0 1 PPM DO NOT USE OIL PUMPED AIR UNDER ANY CIRCUMSTANCES FUEL HYDROGEN GAS 100 ZERO QUALITY WITH THC LESS THAN 0 5 PPM CARRIER GAS NITROGEN GAS ULTRA ZERO GRADE WITH THC LESS THAN 0 05 PPM 4 2 Preliminary Power Off Check List Make the following checks of the installation before proceeding further into the start up procedure 1 Check to see that the sample and supporting gas installation is in accordance with the specifications called for in the installation and application sections of the manual Chapter 3 Be sure that the supporting gases are of the proper composition and are connected to the correct fittings at the rear of the analyzer 2 Check to see that the electrical installation conforms to the instructions contained in the installation section Chapter 3 and on the input output diagram 3 Open the door and check to see that the printed circuit boards and cables are firmly seated in their respective sockets 4 Confirm that recorder and alarm connections are properly made 4 3 Activating the Support Gases All gas controls are located on the front panel as shown in Figure 1 1 42 Teledyne Analytical Instruments Series 4060 Operation 4 3 1 Air 1 Set the air source regulator to 40 psig 2 Adjust the analyzer air regulator until the air pre
24. Span 40 Cal Contact 41 Cal Contact Remote Calibration Protocol To properly time the Digital Remote Cal Inputs to the Model 4060 Analyzer the customer s controller must monitor the Cal Relay Contact When the contact is OPEN the analyzer is analyzing the Remote Cal Inputs are being polled and a span command can be sent When the contact is CLOSED the analyzer is already calibrating It will ignore your request to calibrate and it will not remember that request Once a span command is sent and acknowledged contact closes release it If the command is continued until after the span is complete the calibration will repeat and the Cal Relay Contact CRC will close again For example 1 Test the CRC When the CRC is open send a span command until the CRC closes The CRC will quickly close 34 Teledyne Analytical Instruments Series 4060 Installation 2 When the CRC closes remove the span command When CRC opens again the span calibration is done and the sample is being analyzed 3 3 2 7 RANGE ID RELAYS There are three dedicated Range ID relay contacts They are assigned to relays in ascending order Low range is assigned to Range 1 ID Medium range is assigned to Range 2 ID and High range is assigned to Range 3 ID Table 3 6 lists the pin connections Contacts are normally open and they close when 4060 switches to that particular range Table 3 6 Range ID Relay Connections Pin Function 21 Range
25. a failure will be more evident in the low range If the temperature environment surrounding the analyzer is closely regulated failure in this circuit might go unnoticed after the initial failure If the environment follows day and night temperature changes the analyzer will show a diurnal bi directional drift when operated on zero gas The magnitude of the drift will be a function of the temperature differential experienced by the analyzer To check the circuit employ the following procedure Consult the 4060 schematic and assembly drawings as well as the temperature control PC board schematic and assembly drawings at the rear of the manual for circuit details and component placement An indicator light behind the analyzer door cycles on and off with the heating element the light is on when the heater is on and vice versa Failure of the light to come on at all when the cell compartment is cold indicates a problem in the temperature sensing or control circuitry or the wiring that interconnects the thermistor to the circuit If the light stays on constantly but the compartment does not heat up then a problem with the heating element or connecting wiring is indicated 1 Check the sensing thermistor by measuring the resistance between its connecting wires Disconnect one of the thermistor wires from terminal strip on the temperature controller board P N B30927 the wires out of the thermistor are yellow and 68 Teledyne Analytical In
26. agram identifies the various gas connection points as to function and location Figure 3 1 shows the gas connection points for instruments fitted with the optional autocal module Teledyne Analytical Instruments 37 Installation Series 4060 C a Figure 3 3 Gas Connections Gas connections to the instrument are made at the 1 8 or 1 4 stainless steel tube fittings provided on the rear panel Note that the Purge and Sensor Vent fittings are 1 4 while all other gas connections are 1 8 It is recommended that all gas tubing leading to the connections on the back of the analyzer be of the coiled type This will facilitate sliding the unit out of the case without disconnecting the gas supply to the analyzer Before tubing is connected to the system it must be decontaminated to eliminate any hydrocarbon deposits Using a small torch heat each length of tubing while passing nitrogen through it until it glows red Begin at the nitrogen source end and proceed down the length of the tube chasing the red glow and hydrocarbon deposits down to the open end of the tube Cap the tubing while not in use with suitable non contaminating caps All sample calibration and supporting gas lines which deliver gas to the analyzer must be decontaminated before connection vent lines do not When connecting the various gas lines to the system be absolutely certain that no dead ends are left that is
27. ails the instrument will attempt to ignite the flame 4 more times If it continues to fail after the fifth attempt a flame failure message will appear on the display If this occurs refer to Section 5 4 4 1 Verification of the Flame Guard Circuit The operation of the flame guard circuit has been checked at the factory but should be re verified during start up Use the following procedure after ignition of the flame has been achieved 1 Turn off the fuel at the supply cylinder 2 Observe the fuel pressure gauge on the analyzer control panel The gauge indication will decay as the fuel in the line is exhausted When the gauge reading reaches near zero the flame will extinguish as the fuel solenoid shuts off the fuel supply The analyzer will automatically try to re ignite After 5 attempts it will display flame failure check air fuel and the flame failure LED will be on 3 Open the cylinder supply valve and re ignite the flame by pushing the up and down buttons simultaneously 4 4 2 Ignition and or Flame Guard Circuit Failure If the flame ignition or guard circuits do not operate as described in the above two sections set the instrument fuel regulator to the recommended pressure If still fails to ignite proceed as directed in Chapter 5 Maintenance amp Troubleshooting 4 5 Sample Pump A built in sample pump is provided to draw sample gas from ambient air The gas flow rate should be maintained at about 1000 to 1200 cc
28. alyzer out until it stops then push down on the release 4 Teledyne Analytical Instruments 27 Installation Series 4060 bo a e aa a l ee levers found almost at the end of the sliders both sides at the same time Regardless of configuration the analyzer system must be installed on a level surface with sufficient space allocated on either side for personnel and test equipment access Subject to the foregoing the Analyzer system should be placed as close to the sample point as is possible All pertinent dimensions connecting points and piping details can be found in the drawings section as part of the outline input output and piping diagrams These drawings are specific to the instrument or system to which the manual applies 3 3 User Connections All user connections are made on the rear panel Consult the input output and outline diagrams in the drawing section of the manual Not all the features displayed may be present in your system Refer to any Addenda for additional information that may apply to your instrument 3 3 1 Electrical Power Connections The standard analyzer requires a supply of 100 125VAC single phase power Power connections are made at the rear panel of the unit Refer to the input output diagram for more information The electrical power service must include a high quality ground wire A high quality round wire is a wire that has zero potential difference when measured to the power line neutral If y
29. ambient temperature resistance is in the 100 K ohms region When the flame is ignited its resistance is reduced by a factor of 100 The thermistor is coupled to a semiconductor control circuit on the anode flame guard power supply PC board which will be described in a following section The cell electrodes of both the anode igniter and flame guard thermistor are connected to the electronics chassis by means of a plug in cable The electrode section of the cell may be removed for inspection by turning off the power disconnecting the electrode lead plug and removing the screws which retain the electrode assembly in the sensor body 24 Teledyne Analytical Instruments Series 4060 Operational Theory 2 4 1 Electrometer Amplifier The collector cable is coupled directly to a coaxial fitting located on the electrometer amplifier PC board The PC board is located on the side panel next to but outside of the isothermal chamber It consists of an electrometer amplifier and an operational amplifier This circuit is a very high gain current to voltage converter circuit having an input impedance measuring in the billions of ohms It is static sensitive and highly susceptible to contamination Special care must be taken in handling this PC board Refer to Section 5 5 3 Electrometer Amplifier PC Board for more information concerning the electrometer amplifier and the other printed circuits that follow lt Flame Guard Thermi
30. ame out lamp off when the ignition procedure is employed see section 4 4 Flame Ignition perform the following procedure to isolate the problem consult the system schematic for details of the circuit I Disconnect the anode igniter flame guard thermistor cable from the socket Check the flame guard sensing thermistor by measuring the resistance between pins J4 3 amp 4 of PCB part number B74671 disconnect the cable plug The reading should be about 100 KQ at room temperature The actual resistance is not important since the thermistor experiences radical changes in resistance as the temperature changes No indication in a sufficiently high range on Teledyne Analytical Instruments 69 Maintenance Series 4060 the ohmmeter indicates an open thermistor If the thermistor is hot the resistance will be much lower 3 Check the anode igniter coil for continuity by measuring between pins J4 1 amp 2 of the disconnected cable plug The ohmmeter should indicate a short circuit 4 If either step 2 or 3 does not check as indicated remove the electrode assembly of the detection cell and replace it If the quartz flame tip is damaged the top section of the cell may be removed by disconnecting the vent line and removing the screws around its flange Return the unit complete with attached electrode cable If steps 2 and 3 both check out properly reconnect the anode igniter cable 5 Check K1 and K2 relays operation as the a
31. arm were LATCHING the alarm condition would persist even though the concentration is no longer above the trip point until the user released it RELEASING A LATCHED ALARM When alarm conditions are present the main analysis screen will have one or both of the following messages AL 1 AL 2 followed by the instruction ENT ACK Pressing ENTER will release a latched alarm That is if there will not be an alarm condition until the analysis concentration is again violating the trip point Furthermore the alarms will be suppressed until the analysis value is updated so even though the screen may be reporting a value that should cause an alarm until the analyzer again enters SAMPLE MODE no alarm condition will reoccur TRIGGER POINT This is the threshold at which an active alarm can enter into alarm condition If an alarm is HIGH ACTIVE and set at 20 00 ppb then when the analysis concentration is at or above 20 00 ppb an alarm condition is initiated or maintained CAUTION IT IS NOT GOOD PRACTICE TO SILENCE AN EXISTING ALARM BY SETTING THE ALARM A N ATTRIBUTE TO DEFEAT THE ALARM WILL NOT AUTOMATICALLY RETURN TO ACTIVE STATUS IT MUST BE RESET BY THE OPERATOR IF IT IS NOT RESET YOUR PROCESS WILL BE RUNNING WITHOUT THE SAFEGUARDS THIS INSTRUMENT IS DESIGNED TO PROVIDE 54 j Teledyne Analytical Instruments Series 4060 Operation 4 6 10 The Range Function gt Range Select Man Man Rng R1 R1 0 100
32. at anytime Just scroll through the MAIN MENU with the DOWN UP keys to the appropriate function and ENTER it The analyzer will immediately start that function unless password restrictions have been assigned Password assignment is explained in Section 4 6 17 4 6 5 Span The SPAN function is used to calibrate the analyzer Span can be performed either manually or automatically with the autocal function if equipped The analyzer is calibrated using span gas as described in Section 4 1 This section assumes that this gas has been properly connected and the line checked for leaks To initiate a span calibration lt UP DOWN gt From the MAIN MENU scroll down to the SPAN function lt Enter gt Press lt Enter gt to activate the SPAN function gt Span 80 00 ppb Span Begin The first line allows the user to modify the span target value The second line commences the span after the following query 50 Teledyne Analytical Instruments Series 4060 Operation Begin Span ENTER YES ESCAPE NO Pressing lt Enter gt enters the SPAN mode in the Sampling Phase This is similar to the Analysis Mode both in the Sampling Phase and Analysis Phase The difference is that at the end the analyzer calculates the calibration constants rather than the standard concentration calculation After both Sampling Phase and Analysis Phase are complete the calculation is performed and the 40660 re enters Analysis Mode 4 6 6
33. atching Cannot be defeated Note Reset by pressing the STANDBY button to remove power Then press STANDBY again and any other button except SYSTEM to resume Further detail can be found in Chapter 4 Section 4 6 19 Table 3 4 Alarm Relay Contact Pins Pin Contact 45 Threshold Alarm 1 normally closed contact 28 Threshold Alarm 1 moving contact 46 Threshold Alarm 1 normally open contact 42 Threshold Alarm 2 normally closed contact 44 Threshold Alarm 2 moving contact 43 Threshold Alarm 2 normally open contact 36 System Alarm normally closed contact 20 System Alarm moving contact 37 System Alarm normally open contact Teledyne Analytical Instruments 33 Installation Series 4060 bo a e aa a l ee 3 3 2 6 DIGITAL REMOTE CAL INPUTS The digital remote calibration input accepts 0 V off or 24 VDC on for remote control of calibration See Remote Calibration Protocol below See Table 3 5 for pin connections Span Floating input A 5 24 V input across the and pins puts the analyzer into the Span mode Either side may be grounded at the source of the signal A 0 1 volt across the terminals allows Span mode to terminate when done A synchronous signal must open and close external span valve appropriately Cal Contact This relay contact is closed while analyzer is spanning See Remote Calibration Protocol below Table 3 5 Remote Calibration Connections Pin Function 10 Remote Span 12 Remote
34. atmospheric pollutants Teledyne Analytical Instruments Series 4060 Operational Theory Operational Theory 2 1 Introduction Series 4060 Analyzer for Benzene uses a FID detector and a Gas Chromatograph GC Column Using a carrier gas and a microprocessor actuated switching valve a fixed volume of sample is pushed into the Column maintained at a constant temperature The eluted gas is analyzed for benzene in a FID detector and the column is back flushed to accept the fresh sample in the next cycle Actual separating and detecting sequence may vary depending on compounds of interest in the application for which the analyzer is configured The Series 4060 Analyzer uses a flame ionization detector to sense benzene The FID was selected based on the positive performance and extensive experience in the use of this detector in other Teledyne analyzers namely Model 402R and Model 4020 The FID has proven itself to be a rugged stable long life sensor giving years of trouble free operation in various applications Also considering the fact that the required sensitivity of 100 ppb full scale was achieved FID was considered a better choice over the limited life and less reliable Photo Ionization Detector A stainless steel packed column containing Chromosorb Diatomite was used at a constant temperature of 70 C Using nitrogen as a carrier gas and a 5 ml sample loop benzene elutes from the column within a few minutes Additionally a clear s
35. circuit by touching both an electrode and the cell body simultaneously The reading obtained should be 125 10 VDC 66 Teledyne Analytical Instruments Series 4060 Maintenance 2 If no reading is obtained disconnect the anode igniter cable and check for the voltage on pin J4 1 of the connector located at PC board part number B74671 If the proper voltage is still not present replace the flame guard and anode power supply PC board If it is check the wiring in the anode igniter cable plug If necessary the circuit board can be replaced by first turning off the power then removing 4 screws holding the board WARNING DO NOT TOUCH CAPACITOR C1 OR C2 OR THEIR AN RELATED CIRCUIT FOILS A SHOCK HAZARD MAY EXIST 3 Carefully remove the circuit board without touching any connections which might lead to C1 or C2 After removal discharge the two capacitors by placing a jumper wire across each 4 The anode voltage may also disappear or be greatly diminished when condensation inside the sensor has occurred shorting the igniter to the sensor body across the wet insulator This usually occurs when the flame is turned on if the sensor has not been preheated for at least 1 hour 5 1 2 Electronic Stability If the checks outlined above indicate that conditions are normal allow the analyzer to run electronically with the collector cable disconnected for several hours in the lowest range and with the zero offset value adjusted so t
36. e insulating materials employed the completed PC board is ultrasonically cleaned in laboratory grade alcohol Under no circumstances should the parts described be handled with bare fingers A freshly scrubbed finger stroked along one of the glass resistors would deposit enough skin oil to completely upset the range division of the attenuator circuit Resistor R3 is a 1000 MQ resistor used in the feedback circuit of the amplifier R2 has a resistance of 10 000 MQ and is used in series with the zero potentiometer slider This circuit is used to nullify any offset signal introduced by the signal electrode Trimmer P1 is used to nullify the offset signal generated by the electrometer amplifier The output of the circuit is standardized against gases with known hydrocarbon concentrations by zero and span calibration so that the meter and or recorder indicate the hydrocarbon concentration of the gas being used The positive and negative operating voltage required by the electrometer amplifier is furnished by a switching power supply circuit mounting at the back panel of the Analyzer The stability of the electrometer circuit can be tested as follows 1 Disconnect the collector cable 2 Place the analyzer in the auto range 3 Adjust zero offset value so that the recorder reads at some point upscale and record a 24 hour chart 74 Teledyne Analytical Instruments Series 4060 Appendix Appendix A 1 Specifications and Initial Sett
37. e point within this mode cycle to obtain a baseline reading for further calculation This mode is usually programmed to continue until the compound of interest is fully eluted from the column It is possible to set it up to 25 minutes During the Analysis Mode a Peak Detect period is programmed at which time the analyzer reads the detector output The analyzer integrates the peak area during this time in conjunction with the baseline settings to calculate the concentration of the compound of interest The calculation is performed at the end of the Peak Detector period and the result is displayed at the end of Analysis Mode 2 3 Analyzer Subsystems The Model Analyzer is composed of three subsystems 1 Sample System Di Detector Cell 3 Electronic Signal Processing Display and Control 2 3 1 Sample System All components used to control the sample and supporting gases as well as the combustion portion of the detector cell are located inside the 20 j Teledyne Analytical Instruments Series 4060 Operational Theory analyzer chassis They are accessible by opening the front door of the analyzer Adjustments are made using the appropriate control on the front panel The analyzer contains three separate isothermal chambers SAMPLE FID and COLUMN that are controlled by individual PID temperature controllers These controllers with integral readout display are visible just behind the front pane
38. edyne its affiliates and agents for damage or injury from misuse or neglect of this equipment is implied or assumed WARNING HYDROGEN GAS IS USED IN THIS INSTRUMENT AS A FUEL HYDROGEN IS EXTREMELY FLAMMABLE A N EXTREME CARE MUST BE USED WHEN WORKING AROUND GAS MIXTURES CONTAINING FLAMMABLE GASES A successful leak check was performed at TI Al on the sample system of this instrument prior to calibration testing and shipping Ensure that there are no leaks in the fuel supply lines before applying power to the system Teledyne Analytical Instruments v WARNING A Series 4060 Always purge the entire system before performing any maintenance and always leak check the system after removing any tubing or fittings on the sample system See the procedures for purging and leak checking this instrument on the following pages If toxic gases or other hazardous materials are introduced into the sample system the same precautions regarding leak checking and purging apply to the sample lines and sample supply or delivery lines ELECTRICAL SHOCK HAZARD WITH THE EXCEPTION OF OPENING THE DOOR AND ADJUSTING THE PRESSURE REGULATORS FLOW CONTROLLER OR OBSERVING THE PRESSURE GAUGES AND THE FLOWMETER ONLY AUTHORIZED AND SUITABLY TRAINED PERSONNEL SHOULD PERFORM WORK INSIDE OF THE INSTRUMENT COMPONENTS WITHIN THE COVER ON THE INSIDE OF THE DOOR INSIDE THE ISOTHERMAL CHAMBER SAMPLE SYSTEM AND ON THE ELECTROMETER AMPLIFIER PC BO
39. eparation is observed from other aromatic hydrocarbons namely toluene ethyl benzene and xylenes The actual temperature setpoint and compound separation for your instrument may be different depending on the application It is listed in the Addendum and Testing Results section of Appendix B 2 2 Modes of Operation The analyzer has 2 modes of operation depending on the position of the GC Sampling Valve See Piping Diagram in Figure 2 2 They are Sample Mode position A and Analysis Mode position B Teledyne Analytical Instruments 19 Operational Theory Series 4060 1 Valve Position A Sampling Mode In this mode the analyzer configures the operational valve to back flush the column and charge the sample loop The Sample Mode is programmed to continue for a 7 minute period by factory default however it is usually modified to match the needs of a particular process The specific timing interval for your system is listed in the Addendum and Testing Results section of Appendix B It is possible to set the Sample Mode duration up to 25 minutes Valve Position B Analysis Mode In this mode the analyzer configures the sampling valve to feed the gas in the sample loop through the column and to the detector The eluted sample from the column is fed to the FID for the analysis of the compound of interest in the hydrocarbon stream If configured to do so the analyzer may read the detector for a programmed 5 second period at som
40. ese symbols is described below gt BS PB Symbol C GENERAL WARNING CAUTION Refer to the instructions for details on the specific danger These cautions warn of specific procedures which if not followed could cause bodily Injury and or damage the instrument CAUTION HoT SURFACE WARNING This warning is specific to heated components within the instrument Failure to heed the warning could result in serious burns to skin and underlying tissue WARNING ELECTRICAL SHOCK HAZARD Dangerous voltages appear within this instrument This warning is specific to an electrical hazard existing at or nearby the component or procedure under discussion Failure to heed this warning could result in injury and or death from electrocution Technician Symbol All operations marked with this symbol are to be performed by qualified maintenance personnel only NOTE Additional information and comments regarding a specific component or procedure are highlighted in the form of a note STAND BY This symbol indicates that the instrument is on Stand by but circuits are active Teledyne Analytical Instruments iii Series 4060 CAUTION THE ANALYZER SHOULD ONLY BE USED FOR THE PURPOSE AND IN THE MANNER DESCRIBED IN THIS MANUAL IF YOU USE THE ANALYZER IN A MANNER OTHER THAN THAT FOR WHICH IT WAS INTENDED UNPREDICTABLE BEHAVIOR COULD RESULT POSSIBLY ACCOMPANIED WITH HAZARDOUS CONSEQUENCES This manual provides information des
41. est routine Caution A ALARM SUPPRESSION When an alarm condition occurs see ALARMS one or both of the messages AL 1 and or AL 2 will be displayed on the VFD while in the ANALYSIS SCREEN At this time the ENTER button may be pressed to acknowledge the alarm s in which case the alarms will be suppressed until the analysis value is next updated This can result in a condition where the screen may be reporting a value that should cause an alarm but until the analyzer again enters SAMPLE MODE no alarm condition will reoccur Teledyne Analytical Instruments 45 Operation Series 4060 4 6 1 Default Parameters The versatility of this analyzer usually results in significant changes being made to parameters over the course of time to better suit a particular application Occasionally processes change requiring alteration to alarms filter settings etc At some time it may be beneficial to reset the analyzer to the default conditions as it was when shipped from the factory Below is a listing of the default parameters used in configuring the typical Model 4060 instrument Your specific application may require different settings Refer to the Addendum and Testing Results section of Appendix B for any specific changes or recommendations that apply to your application Range Application Refer to the Addendum and Testing Results section of Appendix B Range Manual Alarms Defeated 20ppb 5Oppb HI NON FAILSAFE NO
42. ey clears the messages generated by incorrect gain settings i e bad span gain too high When the selected option is a function on the MAIN MENU or any SUB MENU screen the menu name appears with a flashing arrow next to it the ESCAPE key is used to return to the parent menu finally returning to the ANALYSIS SCREEN the function If the selected option is a modifiable item value is flashing The ESCAPE key is used to escape to the parent menu without saving the value The value will revert to the original before modification if any 4 6 4 Menu Structure The 4060 screen setup consists of several classes of screens and items No item occupies more than 1 line It is important to read and understand the NAVIGATION AND DATA ENTRY section to fully understand the menu structure 1 48 The ANALYSIS SCREEN displays the analysis value the range the alarms if any and some information about what phase of analysis is occurring j Teledyne Analytical Instruments Series 4060 Operation 2 The MAIN MENU and SUB MENU screens have a flashing arrow on the left side indicating which item is being pointed to MODIFIABLE ITEM screens have a flashing value somewhere in the line 4 6 4 1 MAIN MENUS The MAIN MENU consists of 15 functions you can use to customize and check the operation of the analyzer They are listed here with brief descriptions SPAN Set up and or start a span calibration ALT SPAN Set up and or start
43. gnition Circuit Installation aanannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 3 1 Unpacking the Analyzer 3 2 Mounting the Analyzer Teledyne Analytical Instruments Series 4060 3 3 User Connections 3 3 1 Electrical Power Connections 3 3 2 Electronic Connections 3 3 2 1 Primary Input Power 3 3 2 2 Fuse Installation 3 3 2 3 50 Pin Equipment Interface Connector 3 3 2 4 Analog Output 3 3 2 5 Alarm Relays 3 3 2 6 Digital Remote Cal Inputs 3 3 2 7 Range ID Relays 3 3 2 8 Network I O 3 3 2 9 Pin Out Table 3 3 2 10 RS 232 Port 3 3 3 Gas Connections 3 3 3 1 Effluent 3 3 3 2 Sample Bypass Vent 3 3 3 3 Fuel and Air Connections 3 3 3 4 Sample and Span Gas Connections 3 4 Placing the System in Operation Operation cncetectccccascccccteectacctoscncactewcuacctecicaceentaccccentacateetacccnestacates 4 1 Equipment 4 2 Preliminary Power Off Check List 4 3 Activating the Support Gases 4 3 1 Air 4 3 2 Carrier Gas 4 3 3 Span Gas 4 3 4 Fuel 4 4 Flame Ignition 4 4 1 Verification of the Flame Guard Circuit 4 4 2 Ignition and or Flame Guard Circuit Failure X Teledyne Analytical Instruments 28 28 28 29 30 30 30 32 34 35 35 35 36 37 40 40 40 40 40 41 41 42 42 43 43 43 43 43 44 44 Maintenance amp Troubleshooting Series 4060 4 5 Sample Pump 4 6 Analyzer Operation 4 6 1 Default Parameters 4 6 2 Style Conventions 4 6 3 Navigation and Data Entry 4 6 3 1 Arrow Keys 4 6 3
44. h time Analysis is aborted and a Span Cycle is started in the Sample Phase See Theory of Operation When the Auto Span is disabled the countdown is halted but the Days and Hours remain and will commence countdown if the Auto Span is re enabled The 3rd and 4th lines modify the days and hours until the next Auto Span occurs When these are changed and lt Enter gt is pressed the Auto Span is re set to occur according to the number of Days Hours set The first line will reflect the new count down 4 6 15 Timing Timing controls the parameters of the valve and data acquisition It is specific to the setup of the instrument and must be determined at the factory or TAI trained personnel Refer to the Addendum and Testing Results section of Appendix B for the specific timing settings used for your system and application Do not change these values unless directed by Customer Service at TAI For further information please contact TAI Customer Service 4 6 16 Group Setup Group Setup assigns to each compound a name a range given in Range settings and an associated peak window that is determined in Timing settings These values should not be modified unless directed by TAI customer Service 4 6 17 Password Protection Before a unique password is assigned the system assigns TAI by default If the password is the default it will be displayed automatically The operator just presses lt Enter gt from the any of the MAIN MENU items to be a
45. hat is related to the ambient temperature Use 316 stainless steel dual stage stainless steel diaphragm regulators only in fuel sample and blanket air lines shutoff valves should be used downstream from each regulator Place the supply cylinders as close to the analyzer as possible and connect to the analyzer with new tubing Be sure that all plumbing connections are free of leaks Note Use only stainless steel tubing throughout the system Consult the assembly piping outline drawings and any Teledyne Analytical Instruments 39 Installation Series 4060 Addenda included with this manual to determine if special conditions apply 3 3 3 1 EFFLUENT All the gases introduced into the detection cell vent from one fitting at the rear of the analyzer TAI recommends that the cell be permitted to vent directly to the atmosphere wherever possible If a vent line is required the installation must include a drop out pot to collect the water that is formed by the burning of the hydrogen fuel The vent line must be constructed so that water and dirt cannot collect in it 3 3 3 2 SAMPLE BYPASS VENT The sample bypassed by the back pressure regulation system vents from a separate port at the rear of the analyzer If a vent line is required it must be installed so that water and dirt cannot accumulate in it 3 3 3 3 FUEL AND AIR CONNECTIONS The fuel used to provide combustion should be hydrogen gas zero quality with certified THC
46. hat the recorder is reading midscale If all is normal electronically a noise free pen width recording showing absolutely no instability should be obtained for as long as the analyzer is allowed to run in this configuration If the recording obtained is noisy or erratic replace the electrometer amplifier PC board 5 1 3 Printed Circuit Board Replacement If performance is not adequate then the analyzer must be recalibrated as described in Section 4 6 5 Span before being placed back in service Teledyne Analytical Instruments 67 Maintenance Series 4060 Whenever the flame guard and anode power supply printed circuit board have been replaced the analyzer must be recalibrated If the instrument performs as outlined in this section the problem is not related to the measuring circuit electronics 5 1 4 Collector Cable Before reconnecting the collector cable check the continuity of the center wire of the cable with an ohmmeter by measuring between the center pins at each plug on the lowest resistance scale of the meter Flex the cable while making this measurement to be sure that there is not an intermittent open circuit If there is replace the cable Do not attempt to repair the cable as special tooling is required to disassemble and reassemble the cable plugs 5 2 Temperature Control Electronic Check If the heating circuit fails the output of the analyzer will tend to drift with changes in ambient temperature Such
47. he front panel adjacent to the LED and VFD displays and user interface At the rear of the instrument are ports for the introduction of air fuel zero span and sample gas A single 50 pin user interface cable connector contains input output and alarm signals available to the user An RS 232 port is also available at the rear panel for connection to a remote computer or other digital communication device The Analyzer is set up for either 120 VAC 60 Hz or 230 50 60 Hz operation depending on the customer s requirements The appropriate power cord for your unit has been shipped with this instrument Figure 1 1 shows the Model 4060 front interface while Figure 1 2 shows the rear panel including the user connections 16 Teledyne Analytical Instruments Series 4060 Introduction ee a eee Sample Flow Control Flowmeter Valve LCD i 4 Flame out Display wa LED Pressure Ganini Adjustment Fluorescent Display Pressure User Interface Gauges Keys Figure 1 1 Model 4060 Front Panel Interface Figure 1 2 Model 4060 Rear Panel Teledyne Analytical Instruments 17 Introduction Series 4060 18 1 4 Applications Monitoring the benzene concentration of carbon dioxide gas for use in the beverage industry Monitoring aromatic contamination in air liquefaction and other gas production processes Gas purity certification Detecting trace benzene in ambient air Detecting
48. her the default TAI password or AAA place holders for an existing password will appear on screen Teledyne Analytical Instruments 59 Operation Series 4060 ENTER PASSWORD SCREEN Enter a Password T A lt UP DOWN gt Use the UP DOWN keys to change the letters to the proper password lt Enter gt Press lt Enter gt to advance to the next letter lt Enter gt The last lt Enter gt enters the password lt Escape gt Steps back to the previously entered letter or if on the first letter returns to the MAIN MENU If the correct password has been entered the 4060 now allows access to all the SUBMENU items The 4060 next presents the CHANGE PASSWORD screen CHANGE PASSWORD SCREEN gt Change Password lt Escape gt Press lt Escape gt to return to the MAIN MENU you are now logged in and have access to ALL SUBMENU items lt Enter gt Press lt Enter gt to change the password ENTER NEW PASSWORD SCREEN Enter a new Password T A T 60 j Teledyne Analytical Instruments Series 4060 Operation lt UP DOWN gt Use the UP DOWN keys to change the letters to the new password lt Enter gt Press lt Enter gt to advance to the next letter lt Enter gt The last lt Enter gt moves to the REPEAT PASSWORD ENTRY screen lt Escape gt Steps back to the previously entered letter or if on the first letter returns to the CHANGE PASSWORD menu REPEAT PASSWORD ENTRY S
49. igned to guide you through the installation calibration and operation of your new analyzer Please read this manual and keep it available Occasionally some instruments are customized for a particular application or features and or options added per customer requests Please check the front of this manual for any additional information in the form of an Addendum which discusses specific information procedures cautions and warnings that may be specific to your instrument Manuals do get misplaced Additional manuals can be obtained from Teledyne at the address given in the Appendix Some of our manuals are available in electronic form via the internet Please visit our website at www teledyne ai com iv Teledyne Analytical Instruments Series 4060 Additional Safety Information DANGER COMBUSTIBLE GAS USAGE WARNING This is a general purpose instrument designed for use in a non hazardous area It is the customer s responsibility to ensure safety especially when combustible gases are being analyzed since the potential of gas leaks always exist The customer should ensure that the principles of operating of this equipment are well understood by the user Misuse of this product in any manner tampering with its components or unauthorized substitution of any component may adversely affect the safety of this instrument Since the use of this instrument is beyond the control of Teledyne no responsibility by Tel
50. ings Range s Power Requirements Signal Output Alarms Calibration Contact Refer to Addendum and Testing Results in Appendix B Refer to Addendum and Testing Results in Appendix B Two analog channels Channel 1 0 1 VDC and isolated 4 20 mADC Channel 2 0 1 VDC and isolated 4 20 mADC User configurable as Benzene other aromatics Total HC and Peak traces Two Concentration Alarm C Type relay contacts User configurable One System Alarm for AC power failure and flame out fail safe C type relay contacts Calibration Contact A Type Relay contact for span mode indication RS 232 Output Provided Ambient Temp 0 40 C Install in a well ventilated area 7 Teledyne Analytical Instruments 75 Appendix Series 4060 A 2 Recommended Spare Parts List Qty P N Description 1 B74671A PC board Flame guard amp anode power supply 1 B79153A PC board Electrometer 1 C75825A Micro processor PC board 1 CP2540 Coaxial cable 1 B79154 Sensor Assy 1 C62371A Display PCB Assy 1 B74674A Interface to Motherboard PCB Assy 1 C65507A Backpanel Power Supply PCB Assy 1 F77 Fuse 6 25A 3 AG 1 L156 Lens red 1 L154 LED red 1 A33748 Thermistor assembly 1 V825 10 Port Switching Valve with Actuator Electronic Control and Power Supply 1 CP2408 PID temperature controller 1 G481 Pressure Gauge 0 15psig A minimum charge of US 20 00 is applicable to spare parts orde
51. ions given there Auto Span performs a span calibration using the target span value set in the Span feature menu Note If you require highly accurate AUTOCAL timing use external AUTOCAL control where possible The internal clock in the Model 4060 is accurate to 2 3 Accordingly internally scheduled calibrations can vary 2 3 per day To setup an autocal cycle for a span event to occur in a certain number of days hours From the Analysis Screen press the UP or DOWN key to enter the Setup Mode The VFD will display the first 2 lines of functions available gt AUTOCAL PASSWORD lt UP DOWN3 gt If the arrow is not adjacent to the AUTOCAL menu item use the UP DOWN keys to move the arrow to the proper position lt Enter gt Press lt Enter gt to activate the function and move you to the next screen Here are the autocal parameters with an example of data The underlined items are modifiable but not underlined in the actual display gt AS 3d 20h AUTO SPAN Enabled Span in 11 days Span in 6 hours Teledyne Analytical Instruments 57 Operation Series 4060 Note For instruction on how to set the parameters please refer to the Data Entry section The first line tells how soon the next automatic span will occur Pressing lt Enter gt on this line has no effect The second line Enables Disables the Auto Span When the Auto Span is enabled the values in the first line count down to zero at whic
52. l as shown in Figure 2 1 Figure 2 1 Internal Temperature Controllers The sample chamber contains the 10 port GC switching valve and 2 sample loops The FID chamber contains the flame pressure regulators pressure gauges and flow restrictors used by the FID detector The COLUMN is housed in a separate COLUMN enclosure and maintained at a temperature of 70 C by its PID temperature controller The actual temperature setpoint for your instrument may be different depending on the application It is listed in the Addendum and Testing Results section of Appendix B 2 3 2 Gas Flow Control System The analyzer is equipped with ports for the introduction of air fuel carrier gas span and sample gas It is imperative that these gases are Teledyne Analytical Instruments 21 Operational Theory Series 4060 supplied at constant pressures using two stage stainless steel diaphragm gas regulators The recommended pressure range is 30 to 80 psig however the span gas should be supplied at a pressure of 20 psig to the restrictor fitting either on the optional autocal module or the span inlet on the rear panel The Piping Diagram for the standard instrument is shown in Figure 2 2 A 10 port 2 position GC sampling valve is used to control and direct gas flows including sampling back flush and carrier gas The fixed volume sample loop ensures the same volume of sample injection in the column every cycle If your instrume
53. ledyne Analytical Instruments Series 4060 Installation Installation eee ee Installation of the Series 4060 Analyzer includes 1 Unpacking 2 Mounting 3 Gas connections 4 Electrical connections 5 Testing the system 3 1 Unpacking the Analyzer Although the analyzer is shipped with all the materials you need to install and prepare the system for operation Carefully unpack the Analyzer and inspect it for damage Immediately report any damage or shortages to the shipping agent 3 2 Mounting the Analyzer The Series 4060 is a general purpose analyzer and as such is designed with non sealed enclosures It must be installed in an area where the ambient temperature is not permitted to drop below 32 F nor rise above 100 F In areas outside these temperatures auxiliary heating cooling must be supplied The 4060 enclosure is oil and dust resistant and although it is designed to resist moisture it should NOT be considered completely watertight Mounting to walls or racks must be made securely Avoid locations that are subject to extreme vibration and sway Sufficient space must be provided around the analyzer to accommodate the necessary electrical conduit and plumbing connections The front panel must be allowed to be pulled out for possible service access to all components of the enclosure Refer to the system analyzer outline drawings for dimensions Note To completely slide the analyzer out of the enclosure pull An
54. lip lead to Analyzer chassis ground the standoff for the upper right corner of the mother PCB b Put one end of a 500V rated 1000 ohm resistor in the other end of the clip lead c Check the voltage between chassis ground the standoff for the upper right corner of the mother PCB and the top side of R2 at PCB number B74671 It should be between 5VDC and 5VDC If is in that range the inaccessible hazardous voltage removal procedure is completed if not repeat steps 4 a and 4 b If it is absolutely necessary to work inside the instrument with power on use the ONE HAND RULE Work with one hand only Keep the other hand free without contacting any other object This reduces the possibility of a ground path through the body in case of accidental contact with hazardous voltages Teledyne Analytical Instruments vii WARNING CAUTION A viii Series 4060 THIS INSTRUMENT IS DESIGNED TO BE OPERATED IN A NONHAZARDOUS AREA THE ANALYZER USES HYDROGEN GAS AND OR OTHER COMBUSTIBLE GASES IN ITS OPERATION THIS EQUIPMENT IF NOT USED AND MAINTAINED PROPERLY CAN BE AN EXPLOSION HAZARD THE ANALYZER DEPENDING ON THE APPLICATION MAY ALSO USE TOXIC GASES IT IS THEREFORE THE CUSTOMER S RESPONSIBILITY TO ENSURE THAT PROPER TRAINING AND UNDERSTANDING OF THE PRINCIPLES OF OPERATION OF THIS EQUIPMENT ARE UNDERSTOOD BY THE USER SINCE THE USE OF THIS INSTRUMENT IS BEYOND THE CONTROL OF TELEDYNE NO RESPONSIBILITY BY TELEDYNE
55. llowed access to that item s sub menu If the password has previously been changed from the default then the initial display will be A A A and the correct letters must be input 58 Teledyne Analytical Instruments Series 4060 Operation If user has LOGGED OUT then only the following SUB MENU procedures may be executed 1 PASSWORD 2 LOGOUT which only repeats the logout 3 MODEL Note however that the instrument can still be used for analysis without entering the password To defeat security the password must be entered Note If you use password security it is strongly advised to keep a copy of the password in a separate safe location If the password is lost and security is enabled the analyzer must be cold booted Cold booting invalidates parameters necessary for correct operation so they must be re entered ENTERING A PASSWORD To install a new password or change a previously installed password you must key in and ENTER the old password first If the default password is in effect it will be displayed as the default gausses for each letter pressing lt Enter gt for each letter of the password will enter the default password for you To enter a password lt any key gt From the ANALYSIS SCREEN Enter MAIN MENU setup by pressing an UP DOWN KEY lt UP DOWN gt Use the UP or DOWN key to scroll to PASSWORD AUTOCAL gt PASSWORD lt Enter gt Press lt Enter gt to activate the password function Eit
56. m failure alarm Teledyne Analytical Instruments 15 Introduction Series 4060 e Extensive self diagnostic testing at startup and on demand with continuous power supply monitoring e RS 232 serial digital port for use with a computer or other digital communication device e Analog outputs for concentration and range identification 0 1 VDC standard and isolated 4 20 mA dc e Superior Accuracy 1 2 Principle of Operation The analyzer uses a gas separation column to separate the component of interest like benzene from the other hydrocarbons in the sample gas Using a carrier gas and a microprocessor actuated switching valve the eluted gas is analyzed in Flame Ionization Detector FID and the column is back flushed to accept the fresh sample in the next cycle More information is provided in Section 2 1 Introduction under Operational Theory The electrical output of the electrometer amplifier is directly proportional to the concentrations of the ionizable hydrocarbons present over the ranges of interest 1 3 Analyzer Description The standard analyzer is a rack mountable instrument designed to fit into a standard 19 instrument rack The front interface panel is mounted on a door which when opened allows convenient access to the Analyzer electronics The entire front panel can slide out of the chassis to provide greater access to the electronics and to the sample system Gas pressure and flow controls are mounted on t
57. nal Theor Series 4060 2 4 Detection Cell The upper section of the stainless steel flame ionization cell houses the cylindrical collector electrode the high voltage 260 VDC anode igniter coil and the sensing thermistor of the flame guard circuit see cell cross section in Figure 2 3 WARNING DANGEROUS HIGH VOLTAGE EXISTS AT THE ANODE IGNITER COIL 260 VDC DO NOT ATTEMPT TO DISCONNECT THE IGNITER COIL CABLE OR DISASSEMBLE ANY OF THE FLAME IONIZATION CELL COMPONENTS WITHOUT TURNING OFF THE POWER AND DISCONNECTING THE POWER CORD The collector is interconnected with the electrometer amplifier PC board by a coaxial cable Although the cable and fittings are intended for coaxial service the cable is actually being used as a shielded single conductor connection The anode igniter as its name implies serves two functions When relay K2 at PCB part number B74671 is energized the coil becomes an electrical heating element that glows red hot and ignites the hydrogen fuel When relay K2 at B74671 is de energized the coil is connected to the 260 volt DC terminal of the anode flame guard power supply PC board In this configuration the necessary potential difference is established between the coil anode and collector to promote ionization of the burned hydrocarbons The coil functions as the high voltage anode in all three range positions of the selector switch The thermistor acts as the sensor in the flame guard circuit Its
58. nalyzer is RE IGNITING If the relays do not energize remove the flame guard power supply board and check the forward and backward resistance of its transient suppression diode by measuring pins 13 and 14 of the relay socket The ohmmeter should indicate a short circuit resistance in one direction and some resistance value when the leads are reversed If the indication is a short circuit then the diode must be replaced Note If after replacing a defective diode the circuit still does not work properly the flame guard circuit components have been damaged and the PC board must be replaced 6 If the preceding steps check out correctly the flame guard portion of the circuitry on the flame guard anode power supply PC board is defective IMPORTANT If the circuit proves defective the analyzer will have to be recalibrated after the board is replaced 5 4 Sampling System If the procedures outlined above do not correct the problem the fault must be related to the gas control systems Plugged or faulty regulators plugged restrictors or leaks within the system can cause erratic performance TAI recommends that the factory or an authorized representative be contacted before attempting any repairs to the sample or supporting gas systems within the analyzer 70 Teledyne Analytical Instruments Series 4060 Maintenance 5 5 Printed Circuit Board Descriptions The electronics circuitry of the analyzer is designed with the latest
59. nt is fitted with the optional auto calibration module a separate compartment containing of a pair of solenoid valves is installed for controlling the introduction of sample or span gas to the detector Calibration can be performed automatically on a programmed schedule or manually using the front panel interface 2 3 3 Fuel and Blanket Air Systems Stable flow is achieved by maintaining a constant pressure across restrictors upstream from the cell Each system incorporates an adjustable pressure regulator pressure gauge and restrictor A flame out light is included to indicate when the flame fails A fuel shut off solenoid valve mounted on the line that supplies fuel stops the fuel flow in case of flame failure This valve is located in line with the fuel port 2 3 4 Flame lonization Detection Cell The carrier gas containing sample and fuel are combined within a tee fitting located in the isothermal chamber The mixed gas is emitted from a burner within the sensor assembly Blanket air is introduced into the sensor or cell by means of a separate fitting that is located in the base section of the assembly The upper half of the assembly houses the anode igniter collector and flame guard thermistor 22 Teledyne Analytical Instruments Operational Theor Series 4060 TwNOUdO MOANA FIdN S N aS Figure 2 2 Typical Piping Diagram for the Model 4060 23 Teledyne Analytical Instruments Operatio
60. o the next screen Teledyne Analytical Instruments 55 Operation Series 4060 gt CH1 Offset CH1 Gain CH1 Wave Id for Ch2 or Group Output CH1 Select Groups CH2 Wave Id for Ch2 or Group Output CH2 Select Groups 4 6 12 Linearization Not applicable to the 4060 configuration 4 6 13 Changing Stream Affects the relay on the rear panel that controls which gas is allowed to flow to the column and detector When the instrument has electronically controlled calibration valves option the gas stream can be switched here You can flow span sample or zero gas without entering the calibration mode in order to check instrument response During a span calibration the span stream is activated After a span calibration the sample stream is activated regardless of what was set before the span 4 6 14 Setting up an AUTO CAL The Series 4060 Analyzer can be fitted with an external auto calibration module as an option This feature provides automatic switching of sample and calibration gases and allows the operator to program calibration events to occur automatically Note If your instrument is not fitted with an autocal module the autocal screens will still appear on the display but will be non functional Note Before setting up an AUTOCAL be sure you understand 56 Teledyne Analytical Instruments Series 4060 Operation the Span functions as described in Section 4 6 5 and follow the precaut
61. onizable hydrocarbons present The electrometer amplifier PC board is located on the side of sample module interconnected to the electronics circuitry by means of a single 8 pins cable so that the ease of replacement of a board is maintained The high input impedance requires a shield or cover which is removable for access as well as a shielded input conductor Interconnection with the collector is made by a coaxial cable Although the cable and fittings are intended for coaxial service the cable is actually being used as a shielded single conductor connection The collector cable plugs into a coaxial connector on the electrometer amplifier PC board which is located at the side of the sample module Teledyne Analytical Instruments 73 Maintenance Series 4060 The circuit consists of an electrometer amplifier and an operational amplifier It is a very high gain current to voltage converter circuit having an input impedance measuring in the billions of ohms It is static sensitive and highly susceptible to contamination and special handling precautions must be taken Because of its high impedance the input circuitry to the electrometer has had careful design consideration The resistors R2 and R3 in the input gain circuit see schematic are installed on Teflon insulated standoffs instead of directly to the printed circuit to eliminate the possibility of leakage currents To eliminate any possibility of contamination of th
62. ook the seemingly obvious Check to see that power is available for the instrument and of the proper voltage etc and that connections are correct Also verify that support calibration gases are not depleted 5 1 Measuring Circuit Electrical Checks If the analyzer performs erratically on span gas the trouble can be related to either the integral gas control systems or the electronics To isolate the problem the two systems must be separated To isolate the electronics employ the following procedure e Open the door to the analyzer remove and disconnect the collector cable from the sensor leaving it attached to the electrometer board Consult schematic and assembly drawings for circuitry and location With this cable disconnected the electronic circuitry is completely isolated from the gas control system and cell 5 1 1 Anode Voltage Check If the output can be adjusted by the zero control the above section step 2 the cell anode voltage should be verified as follows WARNING THESE PROCEDURES SHOULD BE CARIED OUT ONLY BY PERSONNEL FAMILIAR WITH HIGH AN VOLTAGE CIRCUIT BOARDS THE ANODE IGNITER UNIT AND ASSOCIATE CIRCUITRY INVOLVE DANGEROUSLY HIGH VOLTAGES Refer to the cell wiring diagram Using a voltmeter set to measure 125 VDC check the voltage on either of the anode igniter electrodes as follows 1 Connect the negative voltmeter lead to ground and the positive lead to either electrode Be careful not to short the
63. ou have the 220 VAC option you will require 220 or 240 VAC 50 60 Hz power Check the analyzer input output diagram power schematic outline and wiring diagrams for incoming power specifications and connecting points CAUTION PRIMARY POWER TO THE SYSTEM SHOULD NOT t BE SUPPLIED UNTIL ALL CUSTOMERS WIRING IS INSPECTED PROPERLY BY START UP PERSONNEL 3 3 2 Electronic Connections Figure 3 1 shows the Series 4060 rear panel There are connections for power digital communications and both digital and analog concentration output 28 Teledyne Analytical Instruments Series 4060 Installation For safe connections no uninsulated wiring should be able to come in contact with fingers tools or clothing during normal operation CAUTION USE SHIELDED CABLES ALSO USE PLUGS THAT PROVIDE EXCELLENT EMI RFI PROTECTION THE AN PLUG CASE MUST BE CONNECTED TO THE CABLE SHIELD AND IT MUST BE TIGHTLY FASTENED TO THE ANALYZER WITH ITS FASTENING SCREWS ULTIMATELY IT IS THE INSTALLER WHO ENSURES THAT THE CONNECTIONS PROVIDE ADEQUATE EMI RFI SIELDING Figure 3 1 Model 4060 Rear Panel with Optional Gas Manifold 3 3 2 1 PRIMARY INPUT POWER The power cord receptacle and fuse block are located in the same assembly Insert the power cord into the power cord receptacle CAUTION POWER IS APPLIED TO THE INSTRUMENT S CIRCUITRY AS LONG AS THE INSTRUMENT IS AN CONNECTED TO THE POWER SOURCE The standard
64. ow input and in turn sends 5VDC to turn on Q1 this holds the relay energized When energized the relay extinguishes the Flame Out indicator light Conversely if the flame goes out bias to the switching transistor is lost the relay drops out and the Flame Out light receives power through normally closed contacts During ignition the flame heats the thermistor holding the relay in the energized condition and the indicator light off If the Flame Out light comes on as the analyzer returns analyzing mode then the flame is not burning and the ignition procedure must be repeated Teledyne Analytical Instruments 71 Maintenance Series 4060 5 5 2 Proportional Temperature Controller PCB Schematic No B 30974 Assembly Dwg No B 30927 The temperature of the chamber to be controlled is regulated by a thermistor directed electronic circuit The thermistor and heating element are located in the chamber and the balance of the circuit components are mounted on the temperature controller printed circuit board which plugs into a connector on the motherboard The control temperature is determined by the value of resistor R3 and C3 on the temperature controller printed circuit board selected at the time of manufacture from the chart on schematic B 30974 to provide the desired control point The thermistor used in the circuit is a negative temperature coefficient NTC device as the chamber temperature increases the resistance of
65. power supply requires 110 VAC 50 60 Hz or 220 VAC 50 60 Hz optional power Teledyne Analytical Instruments 29 Installation Series 4060 bo a e aa a l ee 3 3 2 2 FUSE INSTALLATION The fuse block at the right of the power cord receptacle accepts US or European size fuses A jumper replaces the fuse in whichever fuse receptacle is not used 3 3 2 3 50 PIN EQUIPMENT INTERFACE CONNECTOR Figure 3 2 shows the pin layout of the Equipment Interface connector The arrangement is shown as seen when the viewer faces the rear panel of the analyzer The pin numbers for each input output function are given where each function is described in the paragraphs below l oWe eo oew eo eee ee ee ol Figure 3 2 Equipment Interface Connector Pin Arrangement 3 3 2 4 ANALOG OUTPUT There are four DC output signal pins two pins per output For polarity see Table 3 1 The outputs are 0 1 VDC of Range Voltage rises linearly with increasing concentration from 0 V at 0 concentration to 1 V at full scale Full scale 100 of programmable range 0 1 VDC Range ID 0 20 V Low Range 0 5 V Medium Range 0 80 V High Range 4 20 mA DC Range Current increases linearly with concentration from 4 mA at 0 concentration to 20 mA at full scale Full scale 100 of programmable range 4 20 mA dc Range ID 6 8mA Range 1 12 0 mA Range 2 16 8 mA Range 3 30 Teledyne Analytical Instruments Series 4060 In
66. r from the date of shipment except in cases where quotations or acknowledgements provide for a shorter period Components manufactured by others bear the warranty of their manufacturer This warranty does not cover defects caused by wear accident misuse neglect or repairs other than those performed by Teledyne or an authorized service center We assume no liability for direct or indirect damages of any kind and the purchaser by the acceptance of the equipment will assume all liability for any damage which may result from its use or misuse We reserve the right to employ any suitable material in the manufacture of our apparatus and to make any alterations in the dimensions shape or weight of any parts in so far as such alterations do not adversely affect our warranty Important Notice This instrument provides measurement readings to its user and serves as a tool by which valuable data can be gathered The information provided by the instrument may assist the user in eliminating potential hazards caused by his process however it is essential that all personnel involved in the use of the instrument or its interface be properly trained in the process being measured as well as all instrumentation related to it The safety of personnel is ultimately the responsibility of those who control process conditions While this instrument may be able to provide early warning of imminent danger it has no control over process conditions and it can be mi
67. re the quantity of aromatic hydrocarbons primarily benzene present in a positive pressure sample gas The analyzer is a microprocessor controlled digital instrument based on Teledyne s highly successful Model 402R series analog Total Hydrocarbon Analyzer coupled with a gas separation column and a switching valve The basic analyzer allows for the measurement of benzene in the low ppb range The Analyzer also allows the diagnostic capability to look for other aromatics like toluene ethyl benzene and xylenes Other versions of Series 4060 allowing for dual measurements are also available Contact the factory for further detail 1 1 Main Features of the Analyzer The Analyzer is sophisticated yet simple to use A dual display on the front panel prompts and informs the operator during all phases of operation The main features of the analyzer include e Easy to use front panel interface that includes a red 5 digit LED display and a vacuum fluorescent display VFD driven by microprocessor electronics e High resolution accurate readings of concentration e Versatile analysis with three user definable analysis ranges e Microprocessor based electronics 8 bit CMOS microprocessor with 32 kB RAM and 128 kB ROM e Auto ranging allows analyzer to automatically select the proper preset range for a given measurement Manual override allows the user to lock onto a specific range of interest e Two adjustable concentration alarms and a syste
68. ressed lt Enter gt the self test routine will begin and after a few moments the results will appear onscreen The module is functioning properly if it is followed by GOOD otherwise it is followed by BAD In this case please contact TAI Customer Service for an explanation of the problem To return the analyzer to the MAIN MENU press lt Enter gt after the results screen If you pressed lt Escape gt you will be returned to the Analyze Mode 4 6 9 The Alarms Function The Model 4060 is equipped with two alarms and a system failure alarm relay Each alarm relay has a set of form C contacts rated for 3 amperes resistive load at 250 VAC See Figure in Chapter 3 Installation and or the Interconnection Diagram included at the back of this manual for relay terminal connections The alarm relay contacts are accessible to the user from 50 pin Equipment Connector See Section 3 3 2 5 and Table 3 2 The system failure alarm has a fixed configuration described in Chapter 3 Installation The concentration alarms can be configured from the ALARM function screen as follows 52 Teledyne Analytical Instruments Series 4060 Operation gt AL 1 DEFEATED AL 1 HIGH AL 1 NON FAILSAFE AL 1 NON LATCHING AL 1 20 00 ppb AL 2 ACTIVE AL 2 LOW AL 2 FAILSAFE AL 2 LATCHING AL 2 50 00 ppb Note For the purpose of example Alarm 2 has been set differently than Alarm 1 Note An alarm in alarm condition is signaling that action
69. rs IMPORTANT Orders for replacement parts should include the part number and the model and serial number of the system for which the parts are intended Send orders to TELEDYNE INSTRUMENTS Analytical Instruments 16830 Chestnut Street City of Industry CA 91749 1580 Telephone 626 934 1500 Fax 626 961 2538 Web www teledyne ai com or your local representative Email ask_tai teledyne com 76 Teledyne Analytical Instruments Series 4060 Appendix A 3 Drawing List Refer to the Addendum and Testing Results section of Appendix B for actual drawing list for your application D77394 Outline Diagram D77488 Wiring Diagram C76068 Piping Diagram B79159 Schematic Electrometer PCB B74672 Schematic Flame Guard Anode Power Supply PCB D 65506 Schematic Back Panel Power Supply PCB B79154 FID Electrode Sub Assy D79158 FID Sensor Assembly PC Board Assemblies B74671 PCB Assy Anode Power Supply Flame Guard B79153A PCB Assy Electrometer C 75825 PCB Microprocessor C 65507 PCB Power Supply 4 Teledyne Analytical Instruments 77 Appendix Series 4060 78 Teledyne Analytical Instruments Series 4060 Appendix Appendix B B1 Addendum and Testing Results Teledyne Analytical Instruments 79
70. ssure gauge reads the recommended air pressure of 7 0 psig After the air is flowing through the sensor and warm up time has been completed activate the following gases 4 3 2 Carrier Gas Set the carrier gas source regulator to 80 psig and adjust the analyzer sample regulator until the sample pressure gauge reads the recommended sample pressure of 7 0 psig 4 3 3 Span Gas 1 Feed span gas to the analyzer see Section 4 6 5 Gas switching can also be handled through the autocal valves if the option is added which can also be manually activated as described in Section 4 6 5 2 Observe that the analyzer sample flow meter reads from 0 3 to 1 0 SCFH 4 3 4 Fuel 1 Open the main valve on the fuel source and set the fuel pressure regulator to 40 psig 2 Adjust the fuel regulator until its pressure gauge reads the recommended pressure of 4 0 psig Note Adjust fuel settings only when the red LED flame failure light is off 4 4 Flame Ignition Observe that after warm up count down timer reaches zero timer to preheat the sensor the amber heater lamp is blinking indicating that the temperature controller is maintaining the temperature setpoint and the red Flame Out lamp is on See Figure 1 1 The Model 4060 will automatically attempt a flame ignition sequence following the warm up period which has been preset at the Teledyne Analytical Instruments 43 Operation Series 4060 factory If the ignition process f
71. stallation a ee ee a Table 3 1 Analog Output Connections Pin Function Channel 2 4 20 mA floating Channel 2 4 20 mA floating Channel 1 4 20 mA floating Channel 1 4 20 mA floating Channel 2 0 1 VDC 23 Channel 2 0 1 VDC negative ground 24 Channel 1 0 1 VDC 7 Channel 1 negative ground o o aa A W Examples The analog output signal has a voltage which depends on gas concentration relative to the full scale of the range To relate the signal output to the actual concentration it is necessary to know what range the instrument is currently on especially when the analyzer is in the auto ranging mode The signal output for concentration is linear over the currently selected analysis range For example if the analyzer is set on a range that was defined as 0 100 ppb benzene then the output would be as shown in Table 3 2 To provide an indication of the range the Range ID analog outputs are used They generate a steady preset voltage or current when using the current outputs to represent a particular range Table 3 3 gives the range ID output for each analysis range Table 3 2 Analog Concentration Output Example Ppb Voltage Signal Current Signal Benzene Output VDC Output mA DC 0 0 0 4 0 10 0 1 5 6 20 0 2 7 2 30 0 3 8 8 Teledyne Analytical Instruments 31 Installation Series 4060 bo a e aa a l ee 40 0 4 10 4 50 0 5 12 0 6
72. stor HEHH Collector Anode ignitor lame Tip Restrictors Figure 2 3 Flame Ionization Cell 7 Teledyne Analytical Instruments 25 Operational Theory Series 4060 2 4 2 Anode Power Supply The high voltage anode power supply components are mounted on the anode power supply printed circuit board High voltage regulation is achieved through the use of series connected zener diodes The simplicity of this circuit s design can be attributed to the extremely low current demand of the anode circuit The positive output voltage is nominally 125 volts Output tolerance is 10 volts from the specified 125 volts 2 4 3 Flame Guard Circuit A thermistor controlled transistorized switching circuit is employed to operate a relay in the event of a flame out condition A panel indicator light and fuel shut off solenoid valve are operated by the relay to alarm personnel that a flame out condition has occurred The fuel shut off solenoid valve stops the hydrogen flow 2 4 4 Flame Ignition Circuit The flame ignition circuit includes the anode igniter electrode in the detector cell a transformer and processor controlled relay The circuit is automatically energized when the FID cools due to lack of flame If automatic ignition fails five times there will be a message that reports this and the flame can be manually ignited by pressing simultaneously the Up and Down key 26 Te
73. struments Series 4060 Maintenance Note measure resistance between that wire and the remaining undisturbed terminal Resistance of the thermistor varies with its surrounding temperature A reading of between 10KOhms and 16Kohms at around 25 C may be measured Under very cold conditions the resistance could be as high as 5 0KOhms under hot conditions just a few thousand ohms If the thermistor measures anywhere in this range it is most likely OK Otherwise if the circuit is short or open check the wires leading to the thermistor Check the heating element by measuring its resistance Disconnect one of the heater wires from either terminal 2 or terminal 4 on the temperature control board P N B30927 heater wires are black and check the resistance between that wire and the remaining undisturbed terminal If a reading of approximately 100 Ohms then the heating element is most likely OK If an open circuit is found check the heater wires and a possible connector between the heater and temperature control board If no problems are found and the heater circuit is open then replace the heater element If any of the components located inside the isothermal chamber has failed the instrument must be removed for service If no problems are found with either the thermistor or the heater circuits then replace the temperature control board 5 3 Ignition and or Flame Guard Circuit Checks If the flame guard circuit will not hold the fl
74. sused In particular any alarm or control systems installed must be tested and understood both as to how they operate and as to how they can be defeated Any safeguards required such as locks labels or redundancy must be provided by the user or specifically requested of Teledyne at the time the order is placed Therefore the purchaser must be aware of the hazardous process conditions The purchaser is responsible for the training of personnel for providing hazard warning methods and instrumentation per the appropriate standards and for ensuring that hazard warning devices and instrumentation are maintained and operated properly Teledyne Analytical Instruments the manufacturer of this instrument cannot accept responsibility for conditions beyond its knowledge and control No statement expressed or implied by this document or any information disseminated by the manufacturer or its agents is to be construed as a warranty of adequate safety control under the user s process conditions ii Teledyne Analytical Instruments Series 4060 Safety Messages Your safety and the safety of others is very important We have provided many important safety messages in this manual Please read these messages carefully A safety message alerts you to potential hazards that could hurt you or others Each safety message is associated with a safety alert symbol These symbols are found in the manual and inside the instrument The definition of th
75. t from pin 4 of A1 thus maintaining constant full wave AC power to the heater When the temperature reaches the selected control point pin 13 voltage is about the same as pin 9 voltage and proportional control takes over The rate at which thyristor triac Q1 conducts and allows power to be delivered to the heater is determined by the combination of components R2 amp R3 R4 C3 R5 and the thermistor resistance at the control temperature Consequently the balance point of the bridge formed by this combination of components can be altered by the selection of R3 causing the circuit to seek a temperature at which the thermistor resistance balances the bridge Because IC A1 triggers the thyristor at zero voltage points in the supply voltage cycle transient load current surges and radio frequency interference RFI are substantially reduced In addition use of the zero voltage switch reduces the rate of change of on state current di dt in the thyristor 5 5 3 Electrometer Amplifier PCB Schematic No B79159 Assembly Dwg No B79153A The ions formed in the process of burning hydrogen in the presence of hydrocarbon components of the sample gas cause an electrical conduction between two electrodes in the combustion chamber or detector cell that is amplified by a high sensitivity and high input impedance electrometer amplifier circuit The electrical output of the electrometer amplifier is directly proportional to the quantity of flame i
76. the thermistor decreases and vice versa The resistance of the thermistor in the circuit is compared with the value of resistor R3 when their resistance is equal or when the resistance of R3 is less than that of the thermistor the heating circuit is activated When a temperature deficiency is sensed by the thermistor integrated circuit Al acting as a zero crossing switch applies a pulsed signal to triac Q1 which in turn applies full wave power to the heating element IC Al employs a diode limiter a zero crossing threshold detector an on off sensing amplifier differential comparator and a Darlington output driver thyristor gating circuit to provide the basic switching action The DC operating voltages for these stages are provided by an internal power supply with only capacitor C4 added externally The on off sensing amplifier in this circuit is configured as a free running multivibrator This scheme adds proportional control which takes over when the comparator inputs are at the design differential voltage Initially when cold the thermistor resistance is large and the voltage at pin 7 is larger than that at pin 8 As the temperature of the controlled chamber begins to rise the resistance of the thermistor decreases thus reducing the voltage at pin 8 During this warm up time 72 Teledyne Analytical Instruments Series 4060 Maintenance i a a the thyristor gating circuit is continuously delivering gate curren