Home

Taylor Scale TE10R User's Manual

image

Contents

1. LED Scale Stable LCD Indicator Display Display Button Button Tare Light Unit Conversion Main Features e LCD Screen 1 0 digits display weight e Hold Button When pressed the weight will display for ten seconds even after the weight is removed e Unit Conversion Button When pressed converts the weight display from fractional oz to decimal oz to grams e Tare Button When pressed the scale reading returns to zero Additionally it can be used to offset the weight of a container or other object up to 50 of the scale s capacity Main Features continued e ON OFF Button When pressed turns the scale ON or OFF e Backlit Display Will illuminate when weight is added or removed from platform Press and Hold TARE to turn On Off backlight function e Moisture Resistant Components are sealed for resistance to moisture e Auto Shut Off Scale powers off after 3 minutes of nonuse e Low Battery Indicator Appears on LCD screen when battery is low e Overload Signal Warning appears when weight is at 10 above the scale s rated capacity even after tare up to 50 of capacity in pound mode Before You Begin 1 Remove the scale from its box along with its platform assembly and the adaptor 2 Install the platform assembly onto the scale by matching the plastic posts of the platform assembly with the mating holes on the top of the scale no special orientation is required Battery Instal
2. mode a new item can be added to the platform The display will show the sum of the weights of the added items Another item may be added if desired The display will show the sum of all additional item weights above and beyond the tared out load TARE CAPABILITY A load of up to 50 of the scale s capacity can be tared out while still allowing the weighing of an additional object up to the full capacity of the scale General Operation continued Tare capability example On a 10 pound scale TE10 a load of 5 Ibs 50 can be tared out Once tared out an added weight of 11 Ibs full capacity plus 10 can still be weighed without causing an overload condition If a load that exceeds 50 of the scale s capacity is tared out the additional weight that can be measured will be reduced accordingly HOLD OPERATION The HOLD function may be used to lock the weight on the display for ten 10 seconds even after the load is removed from the platform To use the hold function press the HOLD button A small triangle will appear in the upper left corner of the display next to the word hold indicating the hold function is turned on This triangle and the hold function will remain in place until the HOLD button is pressed again This pressing of the HOLD button a second time will cancel the hold function and the triangle will disappear from the display While the scale is in HOLD mode Pl
3. Auto Shut Off Feature TThe scale will automatically shut off after 3 minutes of nonuse to conserve the battery The auto shut off feature can be disabled to allow the scale to operate continuously To disable the auto shut off feature 1 While the scale is off press and hold the UNIT CONVERSION button 2 While continuing to hold down the UNIT CONVERSION button also press and hold down the ON OFF button 3 The display will show 88888 then A oF The auto off feature is now disabled Release the buttons 4 To enable the auto off feature again repeat steps 1 and 2 A on will appear The auto off feature is now functional Specifications Platform 8 1 16 x 5 Stainless steel TEIOROS 10 x 6 75 Power 1 9 Volt battery not included or AC adaptor included Dimensions 8 1 16 x 7 3 4 x 2 1 4 Weight 2 lbs 3 oz TEIOROS 3lbs 302 Capacity 10 lb x 1 8 oz 10 Ib x 0 05 oz 160 oz x 0 05 oz 5000 gxlg Resolution 0 to 10 Ibs by 1 8 oz increments O to 10 Ibs by 0 05 oz increments O to 5000 g by 1 g increments Accuracy 0z mode 10 division g mode 10 division Precautions This scale is engineered to give you years of satisfactory service if you handle it carefully Here are a few precautions 1 Always read instructions thoroughly to ensure that you have the full benefit of all the unit s features 2 DO NOT immerse unit in water as doing so will cause damage to i
4. As with all small items do not let children handle batteries If swallowed seek medical attention immediately PRECAUTION Do not dispose of batteries in fire Batteries may explode or leak Remove the batteries if the scale will not be used for a long period of time General Operation POWER To turn the scale on press the button marked ON OFF The display will first show 88888 followed by 9 To turn the scale off push the ON OFF button The scale will remember the unit mode last shown and this unit will display when the scale is turned on again UNIT CONVERSION Press the Unit Conversion Button to switch from fractional ounces to decimal ounces to grams to ounces When the scale is turned off it will remember the unit mode last shown and will turn on in that mode WEIGHING When the display shows 0 the scale is ready to weigh an object If the object exceeds the capacity of the scale by more than 10 the display will show Err for error Until the overload condition is reached additional objects may be placed on the platform The display will show the sum of the weights of all the objects When one of multiple objects is removed from the platform the weight of the remaining objects will display TARE OPERATION To tare zero out aload on the platform example the weight of a container press the TARE button The display will show the value o During the TARE
5. and return it prepaid along with receipt showing date of purchase and a note explaining reason for return to Taylor Precision Products Inc 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 USA Customer Service Phone 1 800 225 4834 Customer Service Fax 1 575 526 4347 www taylorusa com There are no expressed warranties except as listed above This warranty gives you specific legal rights and you may also have other rights which vary from state to state For additional product information or warranty information in Canada or elsewhere outside the USA please contact us through www taylorusa com 2013 Taylor Precision Products Inc and its affiliated companies all rights reserved Taylor and Leading the Way in Accuracy are registered trademarks of Taylor Precision Products Inc and its affiliated companies All rights reserved Made to our exact specifications in China NOT LEGAL FOR TRADE TEIOR 11 13WC TETOR TAYLOR Digital Portion Control Scale Leading the Way in Accuracy Instruction Manual Thank you for purchasing a Taylor Digital Portion Control Scale Your scale is an example of superior design and craftsmanship In order to optimize its function be sure the read this instruction manual carefully before use Keep instructions handy for future reference Description of Parts Hold Kilogram Pound Ounces Grams Hold On Off Display Display Display Display Display Button Button
6. ace a load on the platform When the weight is locked in the triangle will begin to flash When the load is removed from the platform the display will continue to show the weight for ten seconds After the ten second period is up the triangle will stop flashing and the display will show 0 If the load is not removed from the platform the triangle will continue to flash The ten second hold period will begin once the load is finally removed from the platform During the ten 10 second period the load can be tared out causing the display to show 0 And additional load will be displayed and held for another ten second period etc If the HOLD button is pressed again the scale will revert to its normal operating mode When the scale turns off the hold function is cancelled When the scale is turned on again it will be in normal operating mode
7. lation The Digital Portion Control Scale operates with a rechargeable battery included To install and charge the battery 1 Remove the battery compartment door on the bottom of the scale 2 Plug the male connector of the rechargeable battery onto the female connector which is located in the battery compartment 3 Place the rechargeable battery into the battery box 4 Replace the battery door 5 To charge the battery insert the connector plug of the adaptor into the jack at the back of the scale Plug the other end of the adaptor into the proper electrical outlet A red LED on the side of the scale will light up indicating the battery is charging When the LED light changes to green the battery is completely charged 6 Allow at least 12 hours for the scale to charge completely The scale will then operate continuously for approximately 14 hours 7 The battery life cycle is approximately 500 recharges If the scale does not function properly after at least 12 hours of charging the battery may need to be replaced The scale will still operate on adaptor power if the battery is not charged 8 To purchase a new rechargeable battery model TERBAT please contact customer service at 1 800 225 4834 9 There is also an AC adaptor included with this scale and can be used in place of the Rechargeable Battery NOTE please recycle or dispose of batteries per local regulations WARNING Batteries may pose a choking hazard
8. nternal components and void the warranty If you spill liquid on it dry it immediately with a soft lint free cloth 3 DO NOT clean the unit with an abrasive or corrosive material This may scratch the plastic parts and corrode the electronic circuits 4 DO NOT subject the units to excessive force shock dust temperature or humidity This may result in malfunction shorter electronic life soan damaged battery and distorted parts 5 DO NOT tamper with the unit s internal components Doing so will invalidate the warranty on the units and may cause damage The unit contains no user serviceable parts 6 This scale is an extremely sensitive weighing device To avoid damage to the unit or the battery do not store anything on the scale 7 Remove the battery if the scale will not be used for a long period of time 8 DO NOT dispose of batteries in fire Disposing of this product in fire could cause batteries to explode or leak Remove the battery if the unit will not be used for a long period of time Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This eq
9. uipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occurin a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help One Year Limited Warranty This product is warranted against defects in materials or workmanship for one 1 year from date of original purchase for the original purchaser It does not cover damages or wear resulting from accident misuse abuse or unauthorized adjustment and or repair Should this product require service or replacement at our option while under warranty please pack the item carefully

Download Pdf Manuals

image

Related Search

Related Contents

User Manual Manualde Uso  instrucciones para el usuario de la secadora  O total é mais do que a soma das partes  V7 HDMI Cable (m/m) black High Speed gold plated connector 5m  AV-RS300N  Troy-Bilt 769-06521 P00 User's Manual  DR 5000 User Manual    PDF資料 - 計測器・分析機器のレンタル  23914-03a - Tanning Bed Parts  

Copyright © All rights reserved.