Superior FAB-1100 User's Manual

image

Contents

1. to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP Printed in U S A 1996 by Lennox Hearth Products 1110 West Taft Avenue P N 903249 REV E 11 2004 Orange CA 92865
2. 2 Ensure that the blower base is firmly seated on the appliance base Ensure that the blower is positioned against the appliance back wall Some appliances are fitted with a blower shield preventing access to the back wall of the appliance In this case remove the shield place the blower complete its installation then replace the shield Step 3 Route the blower sleeved power cord to a switched standard grounded three pronged outlet mounted on the appliance internal J box cover plate prewired at the time of appliance installation see page 2 of this document Figure 3 Ensure power cord minimizes contact with hot appliance surfaces Operate the FAB 1100 from the switch controlling power to the appliance junction box Make Entry where No Obstructions are Present Figure 1 Outlet Plenums Blower FAB 1100 Base Blower Figure 2 Note The FAB 1100 may also be used with the PureHeat appliance and the CGI BAY and GI 3821 gas inserts For use with the PureHeat and CGI BAY appliances follow the instructions in their installation docu ments and those found in the PHEXK and CBEK kits respectively The FAB 1100 is installed in the GI 3821 in accordance with instructions provided with that appliance NOTE DIAGRAMS amp ILLUSTRATIONS NOT TO SCALE ON OFF Wall Switch T L 1 LI 120Vac Blower Plug Junction Box Factory Supplied Not Supplied with Blower Kit Figure 3 APPLIANCE WIRING Step 3 Conne
3. 5 SUPERIOR HEARTH PRODUCTS KITS AND ACCESSORIES FORCED AIR BLOWER KIT FAB 1100 P N 903249 REV E 11 2004 INSTALLATION INSTRUCTIONS FOR BLOWER KIT MODEL FAB 1100 GENERAL INFORMATION The FAB 1100 forced air blower kit consists of a 105 CFM dual blower assembly The blower supplies air delivery at 105 CFM at 0 H O static pressure 90 CFM at 0 2 H O static pressure The maximum operating static pressure is 0 38 H O The FAB 1100 has been tested and certified by CSA Always check local building codes The installation must comply with local regulations as well as the National Electric Code Failure to follow these instructions could cause a fireplace malfunc tion resulting in possible injury and or property damage PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE PRELIMINARY INSPECTION Remove the blower kit from the carton and check for any damage Check inventory blower assembly sleeved power cord and installa tion instructions INSTALLING THE BLOWER Step 1 In most appliances the FAB 1100 blower is simply posi tioned against the appliance back wall with the magnets engaging the sheetmetal rear wall to secure the blower in place Generally access to this location is gained by the opening or removal of the appliance lower compartment door of louvers Figure 1 Step 2 The blower is properly positioned when it is centered against the appliance rear wall with the outlet plenums pointed upwards Figure
4. ct the ground wire to the ground screw located on the inside of the J box or on the J box plate Most appliances are fitted with an electrical J box that can be accessed from outside of the appliance outer wrapper at the time of Step 4 Replace the J box cover back onto the side access opening installation The following general instructions apply and secure with the hex head screw Step 5 Connect the wall switch not provided with blower kit to the WARNING DO NOT CONFUSE BLOWER 120 VAC 60HZ supply wires in the wall receptacle box Figure 4 WIRING CIRCUIT WITH THE APPLIANCE LOW VOLTAGE MILLIVOLT OPERATING CIRCUIT CAUTION ELECTRICAL CONNECTIONS SHOULD ONLY BE PER FORMED BY A QUALIFIED LICENSED ELECTRICIAN MAIN POWER SUPPLY MUST BE TURNED OFF BEFORE CONNECTING FANS TO MAIN ELECTRICAL POWER SUPPLY OR PERFORMING SERVICE To Blower Step 1 Remove the external J box cover by removing the hex head screw The receptacle should be wired into an electrical circuit during the framing of the appliance The J box cover has a 7 8 22mm diameter knockout hole for connection of a conduit bushing Step 2 Wire with minimum 60 C wire in accordance with prevailing codes The blower draws 1 amp at 120 Vac 60Hz CAUTION MAIN POWER SUPPLY MUST BE TURNED OFF BEFORE EXTERNAL WIRING IS PERFORMED Figure 4 NOTE DIAGRAMS amp ILLUSTRATIONS NOT TO SCALE The manufacturer reserves the right

Download Pdf Manuals

image

Related Search

Related Contents

N369203 man cdls worklight DCL050 Euro.indd  Gabarito 94091    Waters 2489 UV/Visible Detector Operator`s Guide  FORBICE ZT-40  MANUAL DE INSTRUCCIONES MOTOSIERRA CS  取扱説明書 - 日立工機  advertencia    Christie CP42LH User Manual  

Copyright © All rights reserved.
Failed to retrieve file