1. timer button will add 0 5 hour to the timer until it reached the maximum of 7 5 hours Adding the numbers indicated equals the total time for the timer For example when the 0 5 and 1 indicators are on at the same time it means the timer has been set for 1 5 hours when the 0 5 1 2 and 4 indicators are on at the same time the timer has been set for 7 5 hours If none of the timer indicators are on the unit will run continuously COOL AIR HUMIDIFYING button o Press once to turn on the water pump press again to turn off the water pump o If the water level is above MIN the red indicator light will turn on and the pump will start working After 3 5 minutes the unit will send out moist and comfortable cool air o If the water level is below MIN or if the water tank is empty please do not turn on this function The unit will beep 5 times and the red indicator light will be flashing to warn that the water tank is low empty and the pump will NOT work o While operating in Cool Air Humidifying mode when the water tank reaches half point the unit will beep 5 times to warn you that the water tank is half empty The red indicator light remains on and the unit continuous running o To prevent damage to the water pump when operating the unit without water please keep the Cool Air Humidifying function OFF The unit will operate as a normal electric fan ION button o Press once to turn the ION function on indicator light is o
2. READ AND SAVE THIS INSTRUCTION MANUAL EA SUNPENTOWN Air Cooler Model SF 609 Functions 1 N Cooling humidifying and air purifying Adopted photo catalysis technology Anti bacterial water tank and germ free water curtain cycle system Three fan air speeds with Sleep Mode function Automatic swing Timer from half an hour to Seven and a half hours Castor wheels for portability Remote control lonizer adopted Contents Parts Name Product Appearance Control Panel Important Safety Notes Operation Specifications Circuit Diagram Maintenance Trouble Shooting Your Guarantee Please read the instruction carefully prior to use Parts Name 1 Product Appearance Front view Rear view Top lid Vater tank Vater vol une i ndex 2 Control Panel Remote receiver TIMER indicator light SPEED indicator light SNe s ION indicatoNight SWING indicator light COOLAIR indicator light EJ SUNPENTOWN SF 609 ION button TIMER button SWING button SPEED button COOLAIR button POWER button Important Safety Notes Make sure the correct power 120V 60 Hz is supplied To avoid electric shock or personal injury do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner Return the unit to Sunpentown see warranty for examination repair or adjustment 3
3. Unplug the appliance when not in use and before maintenance or servicing 4 The applicable temperature to run this unit is between 32 F 104 F Do not operate when the temperature is above or below this range Do not let unit sit under direct sunlight 5 When the tank is full move unit from the side slowly to prevent water from spilling 6 Do not place heavy objects on the machine 7 Close supervision is necessary when any appliance is used by or near children 8 When unplugging pull from the plug and not on the cord 9 Turn off the unit when adding water 10 Turn off and unplug unit before cleaning 11 To avoid excessive dampness do not use the humidifying function for an extended period of time in an area with poor circulation 12 When not planning to use the unit for a long period of time please unplug the power cord drain water and store in a cool dry place 13 Please change water often to keep the water tank clean It is recommended to change the water once every 1 2 days Operation Please fill the water tank as instructed below before turning on the unit Operating instructions 1 ON OFF button Press once to turn ON unit the H indicator light of SPEED mode will be on Press again to turn OFF unit 2 SPEED button When turned ON the unit starts on High the H indicator light is on to adjust o Press once for Medium speed the M indicator light is on o Press again for Low speed th
4. e L indicator light is on o Press again for High speed with Sleep mode the H and SLEEP indicator lights are on Unit will operate in High speed for 2 min Medium speed for 1 min and back to High for 2 min and so on for approx 30 minutes After which the unit will switch to operate in Medium speed for another 30 minutes and finally switch to Low speed Unit will run in Low speed until powered OFF o Press again for Medium speed with Sleep mode the M and SLEEP indicator lights are on Unit will run in Medium speed for 2 min Low speed for 1 min and back to Medium for 2 min and so on for approx 30 minutes After which the unit will switch to Low speed and continues in Low until powered OFF o Press again for Low speed with Sleep mode the L and SLEEP indicator lights are on Unit will operate in Low speed for 2 min stop 1 min and back to Low for 2 min and so on Unit will continue to run in this mode until powered OFF o There are total of six different settings to choose from o To avoid catching a cold while sleeping the Sleep mode will automatically decrease the fan speed slowly Timer can also be used in Sleep mode SWING button Press the SWING button to select the swinging function o Press once to turn on the swinging function indicator light is on which can cover 60 horizontally o Press again for fixed direction indicator light is off TIMER button Each press of the
5. ilter net upwards from opening slot of filter shelf 2 Remove the photo catalysis filter net small black filter 3 Rinse the dust filter net with clean water and allow to dry 4 Replace the photo catalysis filter net and insert the dust filter net back in place o Do not wet the photo catalysis filter figure 3 insolate it in the sun figure 4 Troubleshooting Problem Reasons Solution e Power is not turned on e Turn on power Not blowing air e Timer fulfilled e Switch off Timer mode e Unit is broken defective e Contact Sunpentown Uinikwil notin or On Off button not pressed e Press the On Off button e Unit is broken defective e Contact Sunpentown e Take off rear panel and filter net remove foreign object s e Contact Sunpentown e Contact Sunpentown e There are objects in it Unit makes noise e Faulty motor e Air wheel fan is loose Nobhumiditvin e Water level low empty e Add water to Maximum level ying e Faulty water pump e Contact Sunpentown e Swing button not pressed e Press the Swing button No swing Faulty leaf motor Contact Sunpentown Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired or replaced free of charge This guarantee is subject to the following terms 1 Sunpentown must be notified of the fault 2 Proof of purchase must be presented to Sun
6. n o Press again to turn ION function off WATER FILLING INSTRUCTIONS o Please be sure the power is OFF before filling water o Fill the water tank by pouring water and adding ice into the Ice amp Water Inlet o Amount of water added can be seen from the water indicator located at the bottom front o Make sure the water indicator indicates the water level is above MIN Pour in 2 3 of water 6 Liters and 1 3 of ice 3 Liters for best cooling effect o You can also put some ice or ice packs in the Ice Box located on the top of the unit for extra cooling optional o DONOT add more than 10 Liters of water into the water tank The water indicator light should never rise above MAX or the water tank will overflow O NOTE When operating the unit for the first time please add water to the MAX level Specifications Model Rated Rated Rated Water Water Tank Speed Dimensions N W Voltage Frequency Power Consumption Capacity SF 609 120V 60Hz 60W 0 6 0 7L h 10L 7m s 5 4 x11 8 x25 2 16 5lb Circuit diagram Maintenance Cleaning the filter net and water tank Pull out water tube Phdocdd sis fte nd It swuldbe Waeroutain Fiter hef caritbewatred putin thesun panel A Figure Figure2 Figure3 Figure4 yy Phas To ensure best humidifying and purifying effect please clean the filtration system once a week 1 Pull the dust f
7. pentown s nominated representative 3 The warranty will be void if the product is modified misused or repaired by an unauthorized person The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA Warranty does not include freight charges This GUARANTEE is in addition to your Statutory Rights A o Nogo E SUNPENTOWN INTERNATIONAL INC 18249 Valley Boulevard City of Industry CA 91744 Tel 626 581 1818 Fax 626 581 1398