1. QIQ CIAQIAIQIAQIAQaAaIQIQlQlala ZZZ Z ZZZ ZZZzzz s oojoo oojo The bar above the signal indicates active low SCSI Terminator SMO F551 features an internal SCSI bus terminator When the drive is connected at the end of the SCSI chain functional switch 11 Enable Terminator may be used to terminated the SCSI connection For a single ended cable 50 signal conductor flat cable or a 25 signal twisted cable can be used The cable length shall not exceed six meters Optional Switch Setting SMO F551 features Optional Switch S501 and S502 These two optional dip switches allow the user to set the drive configurations Rear End of the Drive ON S501 12345678 OFF ON S502 1234567 8 OFF Optional Switch Top Panel View Optional Dip Switch Assignments Optional Switch Description Switch Number 1 Reserved 2 Reserved 3 Disable Command Eject S501 4 Reserved 5 Reserved 6 Reserved 7 Disable Write Cache 8 Disable Auto Spin up 1 Reserved 2 Reserved 3 Reserved S502 4 Reserved 5 Disable SCAM Selection 6 Reserved 7 Reserved 8 Enable Write Cache for Write and Verify Command
2. Safety Regulations Owner s Record The model and serial numbers are located on the top of the drive Record the serial number in the space provided below Refer to them whenever you call upon your Sony dealer regarding this product Model No SMO F551 Serial No Information You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment WARNING To prevent fire or shock hazard do not expose the unit to rain or moisture To avoid electrical shock do not open the cabinet Refer servicing to qualified personnel only CAUTION As the laser beam used in the SMO F551 is harmful to the eyes do not attempt to disassemble the unit Refer servicing to qualified personnel only The use of optical instruments with this product will increase eye hazard The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation This label is located on the drive unit s internal chassis Dieses Etikett VORSICHT LASERSTRAHLUNG WENN ABDECKUNG befindet sich auf dem GE FFNET NICHT DEM STRAHL AUSSETZEN DANGER LASER RADIATION WHEN OPEN AVOID DIRECT EXPOSURE TO BEAM DANGER RADIATIONS DU LASER EN CAS D OUVERTURE EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU inneren Chassis des Laufwerkes This MO drive is classified as a CLASS 1 LASER PRODUCT This la
3. Power supply 5 V 5 0 8 A typ 12 V 5 0 9 A typ Dimensions 41 3 x 146 0 x 203 0 mm HxWxD without Front Panel Weight 1 5 kg Design and specifications are subject to change without notice E Compatible Media SMO F551 is compatible with the following 5 1 4 inch 130 mm Magneto Optical Disks Compatibility Type Description ISO Standard Read Write O 8x R W 5 2GB_ 2048 bytes sector ISO IEC 15286 8x R W 4 8GB 1024 bytes sector working draft 8x R W 4 1GB 512 bytes sector 8x WO 5 2GB_ 2048 bytes sector 4 8GB 1024 bytes sector 8x WO 4 1GB 512 bytes sector 4x R W 2 6GB_ 1024 bytes sector ISO IEC 14517 4xR W 2 3GB 512 bytes sector 4x WO 2 6GB 1024 bytes sector 4x WO 2 3GB 512 bytes sector 4x DOW 2 6GB_ 1024 bytes sector 4x DOW 2 3GB 512 bytes sector 2x R W 1 3GB 1024 bytes sector ISO IEC 13549 2x R W 1 2GB 512 bytes sector 2x WO 1 3GB 1024 bytes sector 2x WO 1 2GB 512 bytes sector 1x R W_ 650MB_ 1024 bytes sector ISO IEC 10089 1x R W_ 594MB __ 512 bytes sector 1x WO 650MB 1024 bytes sector ISO IEC 11560 1x WO 594MB 512 bytes sector X X X X XxXxX O O Of O OC O O O OJ O O O O O O O O O O O O O O O O O O O O O O WIR Rewritable WO Write Once DOW Direct Overwrite System Configuration SMO F551 is connected to a host computer through its SCS
4. I interface The maximum of seven peripheral devices can be linked as a daisy chain on the SCSI bus Host Computer SCSI Cable SMO F551 SCSI peripheral devices System Configuration Example Location of Parts This section provides a general description of the SMO F551 Magneto Optical disk drive Front Panel Disk Insertion Slot BUSY Indicator Eject Button Emergency Eject Hole Front View Rear Panel Functional Switch SCSI Connector DC Power Connector GND Terminal Rear View SCSI and DC Power Connector The SCSI and DC Power Connector is located at the upper rear of the drive The drive uses a Molex 53450 5431 combination 50 pin SCSI and 4 pin DC Power male header Recommended female connectors SCSI connector 3M type number 7950 6500 DC Power connector AMP 1 480424 0 MATE N LOCK Functional Switch SCSI Connector DC Power Connector B1 B12 2 50 4 1 A1 A12 1 49 SCSI and DC Power Connector Functional Switch Connector Pin Assignments A1 SCSIID2 B1 GND A2_ SCSIID1 B2 GND A3 SCSI IDO B3 GND A4 Disable SCSI Parity B4 GND A5 Disable Write Cache B5 Reserved A6_ Disable Auto Spin up B6 Reserved A7 Force Verify for Write command B7 Reserved A8
5. KSEL PNES UNNGA EKSPONERING FOR STRALEN VARNING LASERSTRALNING N R DENNA DEL R PPNAD STR LEN R FARLIG VARO AVATTAESSA OLET ALTTIINA LASERSATEILYLLE ALA KATSO SATEESEN Denne merkelappen er festet p apparatets innside Denna varningsskylt finns inuti apparaten Denne m rkat sidder indeni apparatet Tm tarra on kiinnitetty laitteen sis n Tekniske Data E Laser Type Halveder GaAlAs laser B lgelengde 685 nm 10 nm Maksimum utgang 30 mW Specifikationer E Laser Typ Halvledarlaser av typ GaAlAs Vaglaingd 685 nm 10 nm Maximal uteffekt 30 mW Specifikationer E Laser Type Halvlederlaser GaAlAs laser Bglgelengde 685 nm 10 nm Max udgangseffekt 30mW 3 Oo 2e 7838283 AAT 44538 amp 77 2 FAAAAME SE rE NAAN ASA US Diese Ausr stung erf llt die Europ ischen EMC Bestimmungen f r die Verwendung in folgender folgenden Umgebung en e Wohngegenden e Gewerbegebiete e Leichtindustriegebiete Diese Aust stung erf llt die Bestimmungen der Norm EN55022 Klasse B Precautions Safety Considerations m Power supply e Be sure to use 5 V 12 V DC Damage Prevention E Do not subject the drive to shock or vibration E Location requirements Careful consideration should be given to the following in selecting a site to install or store your drive Avoid the following conditions e High humidity e High temperatures e Direct sunlight e Dust e Stron
6. _ Disable Manual Eject B8 Reserved A9 Enable Fast SCSI B9 Reserved A10 Device Type B10 Reserved A11 Enable Termination B11 GND A12 Terminator Power B12 Terminator Power Source This pin is NOT directly connected to the GND Do not use this pin as GND SMO F551 drives the signal to GND level depending on the functional switch setting Otherwise the signal is not driven to GND level WARNING Write cache is enabled as default setting The integrity of the buffer memory content is not guaranteed through power cycling Caution Disable Write Cache setting works as an OR function with the optional dip switch setting Caution When the Fast SCSI function is used it is recommended that the host system and SCSI cables should conform to the Fast SCSI DC Power Connector Pin Assignments Pin Number Description 1 DC 12V 2 12V Return 3 5V Return 4 DC 5V Pin Assignments of SCSI Connector Signal Name Pin No Signal Name GND 1 2 DBO ND 3 4 DBI ND 5 6 DB2 ND 7 8 DB3 ND 9 10 DB4 ND 11 12 DB5 13 14 DB6 15 16 DB7 17 18 DBP 19 20 GND 21 22 GND 23 24 GND 25 26 TERM PW Z s Z w Z s Z s Z zZ ojo vu ies Z 27 28 GND 29 30 GND 31 32 ATN 33 34 GND ojo 35 36 BSY 37 38 ACK 39 40 RST 41 42 MSG 43 44 SEL 45 46 C D 47 48 REQ 49 50 T O ojo
7. bel is located on the ee ae ODUCT top of the drive unit enclosure LASER KLASSE 1 Dieses Etikett befindet sich PRODUKT auf der Oberseite des Laufwerksgeh uses DANGER LASER RADIATION WHEN OPEN AVOID DIRECT EXPOSURE TO BEAM DANGER RADIATIONS DU LASER EN CAS D OUVERTURE EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU VORSICHT LASERSTRAHLUNG WENN ABDECKUNG GE FFNET NICHT DEM STRAHL AUSSETZEN ADVARSEL LASERSTR LING VED BNING UNDGA UDS ETTELSE FOR STR LING ADVARSEL LASERSTR LING NAR DEKSEL PNES UNNGA EKSPONERING FOR STRALEN VARNING LASERSTR LNING N R DENNA DEL R PPNAD STRALEN R FARLIG VARO AVATTAESSA OLET ALTTIINA LASERSATEILYLLE ALA KATSO S TEESEN LUOKAN 1 LASERLAITE KLASS 1 LASER APPARAT VAROITUS Laitteen k ytt minen muulla kuin t ss k ytt ohjeessa mainitulla tavalla saattaa altistaa k ytt j n turvallisuusluokan 1 ylitt v lle n kym tt m lle lasers teilylle VARNING Om apparaten anv nds p annat s tt n i denna bruksanvisning specificerats kan anv ndaren uts ttas f r osynlig laserstralning som verskrider gr nsen f r laserklass 1 DANGER LASER RADIATION WHEN OPEN AVOID DIRECT EXPOSURE TO BEAM DANGER RADIATIONS DU LASER EN CAS D OUVERTURE EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU VORSICHT LASERSTRAHLUNG WENN ABDECKUNG GE FFNET NICHT DEM STRAHL AUSSETZEN ADVARSEL LASERSTR LING VED BNING UNDGA UDS ETTELSE FOR STR LING ADVARSEL LASERSTRALING N R DE
8. g vibration e Wide temperature fluctuations E Moving the drive Be sure to remove the disk cartridge when the drive is not being used Also never move or transport the drive with the disk cartridge still inserted E If problems occur If any problems occur turn off the power and unplug the drive contact your dealer Warning about Cleaning In the drive preventive measures are taken to guard against dust It is unnecessary to clean the optical lens of your drive Using a lens cleaning cartridge may damage the drive Cooling Requirements Forced air cooling is required throughout the drive preventing overheat of the drive mechanism and electrical components Forced air cooling must be provided as a system integration This maximum temperature is applicable to all operating conditions specified in this manual Measuring Point Maximum Temperature Disk Cartridge 55 C 131 F The temperature conditions specified in this manual must always be met for the SMO F551 to function properly SONY MO Disk Drive User s Guide SMO F551 1998 by Sony Corporation Printed in Japan 3 864 285 12 1 Specifications Configuration and Location of Parts Switch setting and Assignments E Operating environment Installation 10 Temperature Operating 5 C to 45 C gradient 10 C h or 18 F h Relative humidity Operating 10 to 90 no condensation E Power supply and others