1. Non Hardware Packing List Window Air Conditioner AAA Batteries 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panels 2 Side Retainer 2 Window Sash Seal Foam Seal for Bottom Rail Owner s Manual eee SPECIFICATIONS e Noise level is measured at a distance of 3 28 ft away from the front of the unit in cooling mode e Power consumption is measured when the fan runs at the highest speed setting e These specifications are for reference only For actual data please refer to the rating label on the back of the unit Serene Ware Product Dimensions W x H x D Package Dimensions W x H x D EROINA Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord Grounding type wall receptacle N _ Do not under any circumstances cut remove or bypass the grounding prong ff Me O DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFI CATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFAC TURER SOLEUS INTERNATIONAL HAS NOT CON Power supply cord N DUCTED INDEPENDENT TEST TO THE INFORMA with 3 prong grounding TION AND THE SPECIFICATIONS PRESENTED plug and current HEREWITHIN detection device INSTALLATION amp ASSEMBLY INSTRUCTIONS Window Preparation Please read all instructions prior to installing your air conditioner Two people are recommended to
2. Do not use a plug adapter Use two or more people to move and install the air conditioner This is a safety alert symbol This symbol alerts you to potential hazards that can harm you or others or even cause death All safety messages will directly follow the safety alert symbol and or the words DANGER or WARNING Failure to immediately follow these instructions may cause serious injury AWARNING or even death All Safety messages alert you of potential hazards how to reduce the chance of injury and what can happen if instructions are not followed correctly ELECTRICAL REQUIREMENTS The electrical ratings for your air conditioner are listed on the model and serial A WARN l NG number label located on the front left side of the unit when facing the front Specific electrical requirements are listed in the chart below Follow the requirements below for the type of plug on the power supply cord G Power Supply Cord SG WAC 15ESE C NEMA 5 15P SG WAC 18ESE C NEMA 6 15P Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove the ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Recommended Ground Method For your personal safety this air conditioner must be grounded This air conditioner is equipped with a 3 prong power supply cord with a grounded plug To minimize the possibility of ele
3. The RESET button must be engaged for proper use e The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset e Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device e Adamaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree e The power supply cord contains new user serviceable parts Opening the tamper resistant case voids all warranty and per formance claims A Reset ne a NOTE Your units power cord and plug may differ from the one B Test button shown PARTS LIST Hardware Qty in plastic bag 14K 15K 18K Washer Head Locking Screw For window panels WINDOW SASH SEAL SAFETY LOCK AND 24 ROUND HEAD SCREW E _ OQ Safety Lock e 1 2 Long Screw and locknut TOP ANGLE FOAM GASKET fe 3 4 Long Flat i Head Bolt and Locknut cue A Syg _ Sill Angle Bracket FRAME i lt k k A ASSEMBLY EE Long hex head locking screw for topangle side 7 retainer 5 16 Long SIDE RETAINER ae 7 8 Round head Screw iS k Mi 1 i LAN AWWA MI 3 4 Round head Screw SEAL BOTTOM RAIL TO UNIT l FRAME ASSEMBLY RIGHT E TOOLS NEEDED aeLone NG UT Large Flathead Screwdriver BolT gh ANGLE Tape Measurer Adjustable Wrench or Pliers Pencil Level socket Wrenches Phillips Head Screwdriver
4. To se the Auto off Timer press the DELAY button on the unit or remote control Each ouch of the A Y on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET light will turn on while setting e To see the remaining time press the DELAY Button To change the timer setting use the A V on the unit or the buttons on the remote To cancel the timer press the DELAY button until the SET light turns off USING YOUR AIR CONDITIONER Cont Freezing Conditions This is a cooling only air conditioner It is not designed for freezing outdoor conditions It must not be used in freezing outdoor conditions Remote Control To ensure proper operation when using the remote control aim the remote directly at the signal receiver on the air condi tioner e The remote control has a signal range up to 20 feet e Make sure nothing is blocking the remote con trol signal from being received by the air con ditioner e Make sure the batteries are installed correctly and still have power Cooling Mode Use the COOL mode at Low Me dium High or Auto Fan speed when cooling is needed Use the temperature A V buttons to set the desired temperature between 64 F and 86 F e Once the temperature is set the compressor will cycle on and off to keep the room temperature at the set temperature level The lower the set thermostat temperature the cooler the room will become The higher the s
5. panel and remove the filter FIG 1 below 2 Lift the front panel upwards to remove and place to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet FIG 3 amp 4 INSTALLATION amp ASSEMBLY INSTRUCTIONS WINDOW MOUNTING REMOVE CHASSIS 6 Remove the shipping screws from the top of the unit and the right side of the cabinet if installed FIG 6 amp 7 Wal I Ta TRL apii i Jiii PANU I PL 0 Stl Ht L SOHO TTC N m A j pentaan mad EAO En tAE UTOTT um ogi iH AUN miten waten ti Wt INEM ENTE W n LULA INE Jig Hest LULU ALTE bt E ji peapea AHN UCAULPUU HNC i P I ea ea Tea 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift near the top of the unit FIG 8 Do not pull or Z hit im TT iN a ja to the unit may eaan ieran Bask iane nanaonan lanata RCCL LE result FIG 8 ASSEMBLY amp INSTALLATION CONT Top Angle Rail and Side Bracket Installation AIR CONDITIONER CABINET Place the air conditioner on a hard flat surface Locate the foam gasket and top angle rail Attach the foam gasket to the top angle rail Install top angle side to cabinet as shown in FIG 7 I SECTION SCREW TOP VIEW p sat Foam Gasket and Top PANEL Angle
6. temperature will appear in the display NOTE Auto Fan Speed cannot be used in Fan tioner Only mode e The remote control has a signal range up to 20 feet e Make sure nothing is blocking the remote con trol signal from being received by the air con ditioner Loss of Power Protection If power to the air conditioner is lost or interrupted the air condi tioner will automatically re start in the setting last used prior to power loss If the Timer was set to automatically turn the air conditioner off or on it will resume countdown at the amount time left prior to power loss You may need to set a new time if desired e Make sure the batteries are installed correctly and still have power Cooling Mode Use the COOL mode at Low Me dium High or Auto Fan speed when cooling is needed Use the temperature A V buttons to set the desired temperature between 64 F and 86 F Air Direction Use the lever on the front air vents to adjust the direction of the airflow You can di rect the airflow left right up or down The lever is located on the right side of the air vent e Once the temperature is set the compressor will cycle on and off to keep the room temperature at the set temperature level The lower the set thermostat temperature the cooler the room will become The higher the set thermostat temperature the warmer the room will become For Normal Cooling Set the Mode to Cool and the Fan to High or Med with
7. Control is not working The batteries are inserted incorrectly e Check the position of the batteries The batteries may be dead e Replace the batteries a TROUBLESHOOTING CONT PROBLEM POSSIBLE CAUSES SOLUTIONS Water is dripping inside the room The air conditioner is not correctly For proper water drainage make tilted outside sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is This is normal for a short period in draining into the base pan areas with low humidity and nor mal for a longer period in areas with high humidity Digital Display reads F1 F2 or Asensor has failed Contact customer service FJ 20 SS SS Tt WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air Powered by Gree Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal use Soleus International will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As a condition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase i
8. Rail ia li the Cabinet Inside the Window Open the window and place the cabinet in the middle of the window sill Make sure the bottom rail is seated over the window sill as shown below Bring the window down temporar ily behind the top angle rail to hold the cabinet in place 5 Slide the I section of the window panel into the side bracket of the cabinet FIG 8a Do this for both sides _ SIDE RETAINER FIG 8a 3 Fasten cabinet to window sill using two 3 4 HEX Head screws Pre drill holes if needed Add the bottom rail seal over the screws WINDOW FILLER PANEL SLA Le A Wn SIDE RETAINER WINDOW FILLER PANEL OO Boom OO Boom S 6 Insert top and bottom legs of window filler panel frame into channel in the top angle and bottom rail Do both sides Install side retainer to cabinet as shown FIG 8B 7 8 Round Head Screw WINDOW FILLER PANEL Install Support Brackets Extend the Accordion Panels 1 Hold each support bracket flush against the outside of 1 Carefully raise the window to expose the accordion the window sill Tighten each bracket to the bottom of panel and panel frame Loosen the locking screws so the cabinet as shown below Mark the brackets at top lever of the window sill and then remove i i 7 x ms 4 3 4 Round Head Screw the accordion panels slide easily Extend each panel to completely fill the width of the window Tighten t
9. SOLEUSA Powered by e GREE a ENERGY STAR Models SG WAC 15ESE C SG WAC 18ESE C Electronic Window A C Operating Instructions 20060 8404 555 4 PTET LLL LLL E iis 14 44 4 40 0 58 geddddaddaa ii SOLEUSAI5 Powered by Thank you for choosing a Soleus Air powered by Gree Air Conditioner This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location Date Purchased Serial Number located on back of unit E IMPORTANT SAFETY INSTRUCTIONS Before installing and using your air conditioner please read this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the following basic precautions e Plug into a grounded 3 prong outlet Do not use an extension cord e Donot remove the ground prong Unplug the air conditioner before servicing e
10. ation This air conditioner has a slide out chassis so that it can be installed through an outside wall as specified below MAX WALL THICKNESS 10 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that Does not support major structural loads such as the frame construction at ends of windows and under truss bearing points etc Does not have plumbing or wiring inside Is near existing electrical outlets or where another out let can or will be installed Does not have objects blocking the air vents which limits cooling Allows unblocked airflow from the rear and sides of the air conditioner Prepare the Wall 1 Prepare the wall in frame construction including brick and stucco veneer Working from inside the room find the wall stud that is nearest the center of the installa tion area Cut a hole on each side of the center stud Measure between the inside edges of every other stud as shown below 3 3 8 MIN 8 6 cm ASSEMBLY amp INSTALLATION THRU THE WALL CONT Carefully measure and cut an opening with the following NOTE If wall thickness is 8 1 2 or more add aluminum dimensions depending on your model FIG 1 amp 2 flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and WIDTH X ins
11. ause the dry cooling coils to accumulate frost To clean the air filter Never use harsh cleaners wax or polish on the cabinet front 1 Remove the filter by pulling down on the in Be sure to wring excess water from the cloth dents of the filter door on the front of the unit before wiping around the controls Excess See FIG 13 water in or around the controls may cause Wash the filter using liquid dish soap and damage to the air conditioner warm water Rinse the filter thoroughly Gen tly shake the filter to remove excess water Winter Storage Let the filter dry completely before placing it To store the air conditioner when it is not in use into the air conditioner for an extended period of time remove it care If you do not wish to wash the filter you may fully from the window according to the installation vacuum the filter to remove the dust and instructions and cover it with plastic or place it in other particles the original box A A indents Wear and Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping CE TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged e Make sure the air conditioner is plug is pushed completely into the outlet The fuse is blown circuit breaker is e Check t
12. cal Support and Warranty Service Please Call 888 876 5387 Or Write To Soleus International Inc 20035 E Walnut Dr N City of Industry CA 91789 www soleusair com www soleusgreen com 21
13. ctrical shock the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances If a 3 prong outlet is not available it is the cus tomer s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician It is the customer s responsibility Copies of the standards listed may be obtained from e To contact a qualified electrician National Fire Protection Association e To assure that the electrical installation is adequate One Batterymarch Park and in conformance with the National Electrical Code Quincy Massachusetts 02269 ANSI NFPA 70 latest edition and all local codes and ordinances LCDI Power Cord and Plug This air conditioner is equipped with an LCDI Leakage Current Detection and Interruption power cord that is required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is damaged and leakage occurs power will be disconnected from the unit The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test the plug 1 Plug power cord into a grounded 3 prong outlet 2 Press RESET on some units a green light will turn on 3 Press the TEST Button the circuit should trip and cut all power to the air conditioner on some units a green light may turn off 4 Press the RESET button for use You will hear a click and the A C is not ready for use NOTES e
14. er 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees or awnings Check the inside area to make sure curtains drapes or blinds will not prevent proper airflow 2 Check the available electrical outlet The power supply must be the same as shown on the unit serial nameplate located on the left side of the unit near the front faceplate Be sure the outlet is close enough for the power cord to reach 3 Carefully unpack the air conditioner Remove all packing material and make sure the floor is protected when remov ing Due to the large size of this air conditioner two people should move the unit together CAUTION When handling the unit be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils INSTALLATION amp ASSEMBLY INSTRUCTIONS WINDOW MOUNTING REMOVE CHASSIS 1 Pull down the front panel and remove the filter FIG 1 below 2 Lift the front panel upwards to remove and place to the side _ egy anna _ Sings ay a 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet FIG 3 amp 4 PEEL LLL INSTALLATION amp ASSEMBLY INSTRUCTIONS WINDOW MOUNTING REMOVE CHASSIS 1 Pull down the front
15. et thermostat temperature the warmer the room will become For Normal Cooling Set the Mode to Cool and the Fan to High or Med with the termperature set in the middle For Maximum Cooling Set the Mode to Cool and the Fan to High with a lower set temperature For Quieter amp Nighttime Cooling Set the Mode to Cool and the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin Heat Mode Use the Heat mode at Low Med High or Auto Fan Speed for heating Use the temperature A V buttons to set the desired temperature between 64 F and 86 F in 1 F increments e For Normal Heating Set the Mode to Heat and the Fan to High or Med with the termperature set in the middle For Maximum Heating Set the Mode to Heat and the Fan to High with a lower set temperature For Quieter amp Nighttime Heating Set the Mode to Heat and the Fan to Low with the temperature set in the middle Energy Saver Mode Controls the Fan On The fan will cycle on and off with the compressor This results in winder variations of room temperature and humidity Normally used with the room is unoccupied NOTE The fan my continue to run for a short time after the compres sor cycles off Off The fan runs all the time in fan o
16. he house fuse circuit tripped breaker box and replace the fuse or reset the breaker Power Failure e The unit will automatically re start when power is restored e There is a protective time delay approx 3 minutes to prevent tripping of the compressor overload For this reason the unit may not start normal cooling for 3 minutes after it is turned back on The current interrupter device is e Press the RESET button located tripped on the power cord plug e Ifthe RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted e Make sure there are no curtains blinds or furniture blocking the front of the air conditioner The temperature control may not be e Lower the set thermostat tempera set correctly ture The air filter is dirty e Clean the filter See the Cleaning and Care Section of the manual The room may be too warm e Please allow time for the room to cool down after turning on the air conditioner Cold air is escaping e Check for open furnace registers and cold air returns The Cooling Coils are frozen e See Air Conditioner Freezing Up below Ice blocks the air flow and stops the air e Set the MODE dial to HIGH FAN conditioner from cooling the room or HIGH COOL and set the ther The Air Conditioner is freezing up mostat to a higher temperature The Remote
17. he locking screws when the panels are fully extended Install the Window Lock and Sash Seal C 1 Trim the sash seal to fit the width of the window Insert Locknut lt the sash seal into space between the upper and lower A 1 sashes Sill Angle Bracket g 2 each req d Flat Head Bolt i for each sup port bracket WINDOW SASH SEAL Assemble the sill angle brackets to the support brack ets at the marked position as shown above Hand tighten but not all the way for any changes that may need to be made later during installation Install the support brackets with sill angle brackets attached to the bottom of the cabinet as shown below Tighten all 6 bolts securely 1 2 long screw and 2 locknuts 3 4 Round Head Screw ASSEMBLY amp INSTALLATION CONT Installing the Chassis into the Cabinet 1 Team lift two people the air conditioner chassis and carefully slide it into the cabinet Let the front of the air conditioner hang out approximately 6 CAUTION DO NOT PUSH ON THE CONTROLS OR FINNED COILS Be sure the chassis is firmly seated in the back of the cabinet Insert all screws removed during window installation and reattach the front face plate front panel and the air filter Use the REMOVE CHASSIS instructions and figures 1 6 for reference THRU THE WALL INSTALLATION NOTE Consult local building codes prior to installation and or a qualified carpenter Select the Wall Loc
18. ide model plus twice the thickness of the outer wall framing material used HEIGHT Y inside model height plus twice the thickness of framing material used Model SG WAC 15ESE C SG WAC 18ESE C AULK AS Inside Frame Height 18 45 7 cm a A QUIRED Inside Frame Width 23 7 8 60 6 cm ALUMINUM FLASHING OVER BOTTOM OF FRAME Prepare and Install the Cabinet 1 Slide the chassis from the cabinet Refer back to the REMOVE CHASSIS instructions and FIG 1 6 in the WINDOW MOUNTING SECTION Place the cabinet into the opening with the bottom rail resting firmly on the bottom board of the wood frame Position the cabinet so it is tilted properly for water re moval as seen below 3 4 PLUS Build a wooden frame with the INSIDE dimensions of TRIM THICKNESS your model listed above Measure twice The frame SEE PARA 5 depth should be the same as the wall thickness Fill in extra space from the opening to the studs with wood spacers as shown below Nail the spacers to the studs They should be flush with the dry wall NAIL SPACERS TO STUDS 4 Secure the bottom rail to the wood frame with two large 1 2 5 cm long wood screws as shown below FIG 2 1 LONG nn ASSEMBLY amp INSTALLATION THRU THE WALL CONT MASONRY CONSTRUCTION Refer to the SUPPORT BRACKET ASSEMBLY in the WINDOW MOUNTING section to assemble the support brackets A wooden strip nailed to the outside wall should be used in conjunct
19. install this product If a new electrical outlet is required have the outlet installed by a qualified electrician before installing the unit Before installing the unit check the dimensions of your window to make sure the air conditioner will fit This unit is made to fit inside a standard double hung window Make sure the window is in good shape and able to firmly hold the needed screws If not make repairs prior to installing the unit Model SG WAC IS5ESE C SG WAC I8ESE_C Unit Height 17 5 8 17 5 8 Unit Width 25 2 23 12 Min Window Opening See 18 1 2 18 1 2 FIG 1 Min Window Width 26 1 2 26 1 2 Max Window Width 40 1 2 40 1 2 Storm Window Requirements A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly To adjust for this attach a board or piece of wood to the sill The board or wood piece should have a depth of at least 1 1 2 Make sure the board or piece of wood is approximately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drainage See FIG 2 FIG 1 ll FIG 2 _ SASH H SASH 19 1 2 MIN 19 1 2 MIN FNAN 11 2 MIN Board or wood piece must be approximately 1 2 higher than the storm window frame for proper drainage Storm window frame or Storm window frame obstruction or obstruction Prior to Installing the Air Condition
20. ion with the angled sill support brack ets Support Bracket 5 Screw or nail the cabinet to the wooden frame using shims if the frame is oversized to eliminate possible noise Remember to maintain proper slope for water elimination 6 Install the chassis into the cabinet by following the steps described in the WINDOW MOUNTING section OPTIONAL Caulking and installation of the trim on the interior wall may be done if desired Caulk the openings around the top and sides of the cabinet and all sides of the wood sleeve to the opening NOTE See the WINDOW MOUNTING instructions for the bottom rail seal location Cut or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 Secure the cabinet in place using masonry nails or masonry anchor screws Or build a frame using the instructions found in the THRU THE WALL installation section Make sure the masonry above the cabinet is supported well Use the existing holes in the cabinet or additional drilled holes to fasten the cabinet at various positions Make sure that the side louvers are clear of any ob structions Install the exterior cabinet support brackets according to the SUPPORT BRACKET INSTALLATION instruc tions in the THRU THE WALL installation section Caulk or flash with aluminum if needed This will pro vide a tight seal around the top and sides of the cabi
21. net For a more aesthetically pleasing installation apply wood trim molding around the sides of the cabinet with out obstructing the side louvers USING YOUR AIR CONDITIONER Electronic Control Panel amp Remote Control This display always shows the room temperature except when setting the Set temperature or the Timer When the light is on the unit is in temperature or timer set mode TEMP TIME O AUTO O HEAT O HIGH O cooL O MED O ENERGY SAVER e O Low O FAN ONLY SPEED 6 B aA 5 G i wale Light Indicates the Air Conditioner Controls Timer is set f Decrease _ fo Fan Speed X Increase Decrease Temperature Remote Control Normal Operating Sounds e You may hear a pinging noise caused by water hitting the condenser on rainy days or when the humidity is high This design feature helps re move moisture and improve efficiency You may hear the thermostat click when the com pressor cycles on and off Water will collect in the base pan during rain or days of high humidity The water may overflow and drip from the outside part of the unit The fan may run even when the compressor is not on Power Button Turns the air conditioner on and off Digital Display Displays the current room tem perature or the amount of time left on the timer Shows the Set Temp when setting the tempera ture Shows the Timer Set when setting the timer The once the timer and or temperature are se
22. nvoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc e Freight and Insurance cost for the warranty service e Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Techni
23. r cooling mode Fan Only Mode Use Fan Only mode at Low Med or High fan speed to provide air circulation and filtering without cooling Since fan only setting do not provide cooling a Set temperature cannot be entered The room temperature will appear in the display NOTE Auto Fan Speed cannot be used in Fan Only mode Loss of Power Protection If power to the air conditioner is lost or interrupted the air condi tioner will automatically re start in the setting last used prior to power loss If the Timer was set to automatically turn the air conditioner off or on it will resume countdown at the amount time left prior to power loss You may need to set a new time if desired Air Direction Use the lever near on the front air vents to adjust the direction of the airflow You can direct the airflow left or right only The lever is located on the right side of the air vent USING YOUR AIR CONDITIONER Cont e Freezing Conditions This is a cooling only air conditioner It is not designed for freezing outdoor conditions It must not be used in freezing outdoor conditions Remote Control To ensure proper operation when using the remote control aim the remote directly at the signal receiver on the air condi Fan Only Mode Use Fan Only mode at Low Med or High fan speed to provide air circulation and filtering without cooling Since fan only setting do not provide cooling a Set temperature cannot be entered The room
24. t the display will change to show the current room temperature To see the set temperature again simply press either of the Temp Delay A V buttons Temperature Set Use these buttons on the con trol panel and remote to increase or decrease the Set Temperature the desired room temperature in cooling or energy saver mode The SET light will light up when setting the temperature Timer Set Use these buttons on the control panel and remote to set the Timer Each press of the Timer DELAY buttons will increase or de crease the timer For timer instructions see 7 Fan Speed amp Auto Fan Use the fan speed but tons to change the fan speed Choose between low medium high and Auto When using the re mote control press the AUTO button to turn auto mode on and off and the FAN and FAN buttons to select low medium or high fan speed Mode Button Press the mode button to cycle through the various modes Cooling Energy Saver Heat and Fan only Auto on Timer When the air conditioner is off it can be set to automatically turn on in 1 24 hours at the previous set mode and fan setting To set the Auto on Timer press the DELAY button on the unit or remote control Each touch of the A V on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET light will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 1 24 hours
25. the termperature set in the middle For Maximum Cooling Set the Mode to Cool and the Fan to High with a lower set temperature For Quieter amp Nighttime Cooling Set the Mode to Cool and the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin e Energy Saver Mode Controls the Fan On The fan will cycle on and off with the compressor This results in winder variations of room temperature and humidity Normally used with the room is unoccupied NOTE The fan my continue to run for a short time after the compressor cycles off Off The fan runs all the time in fan or cooling mode CARE AND CLEANING Cabinet Cleaning Clean your air conditioner to keep it looking new_ TO clean the air conditioner cabinet and to minimize dust build up e Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of Air Filter Cleaning the air conditioner may be dusted with an oil The air filter should be checked at least once free cloth or washed with a cloth dampened in every month to see if it needs cleaning Trapped a solution of warm water and mild liquid soap particles and dust can build up in the filter and Rinse thoroughly with a damp cloth and wipe may decrease airflow as well as c