Home

Simer Pumps 2944RP User's Manual

image

Contents

1. 1 1 4 slip 1 1 2 slip MOS 1 1 4 NOTICE Do not reduce size of discharge pipe or hose below 1 1 4 diameter If discharge is too small pump will overheat and fail prematurely NOTICE This unit is not designed as a waterfall or fountain pump or for applications involving salt water or brine Use with waterfalls fountains salt water or brine will void warranty Pump water only with this pump Do not use where water recirculates Not designed for use as a swimming pool drainer PERFORMANCE GPH LPH AT TOTAL FEET M OF LIFT 5 10 15 No flow Series HP 1 5m 3m 4 6m A reoni shown CAPACITY GALLONS L HOUR below 0944RP 12 3200 2700 2000 24Ft 12 113 10 220 7 571 7 3M ELECTRICAL amp SWITCH SPECIFICATIONS Individual Motor Branch Switch Setting Full Load Circuit in inches mm Series HP Amps Req Amps On Off 2944RP 1 2 5 5 15 8 203 3 5 89 GENERAL SAFETY INFORMATION Electrically powered sump pumps normally give many years of trouble free service when correctly installed maintained and used However unusual circumstances interruption of power to the pump dirt debris in the sump flooding that exceeds the pump s capacity electrical or mechanical failure in the pump etc may prevent your pump from func tioning normally To prevent possible water damage due to flooding consult your re
2. Delavan WI U S A 53115 Tel fono 1 800 468 7867 1 800 546 7867 Fax 1 800 390 5351 E Mail info simerpumps com Sitio Web http www simerpumps com
3. OWNER S MANUAL Imer Quick Install Sump Pump NOTICE D UTILISATION 293 Wright St Delavan WI 53115 Pompe de puisard 2 Phone 1 800 468 7867 installation rapide 1 800 546 7867 Fax 1 800 390 5351 MANUAL DEL USUARIO Web Site http www simerpump com Bomba para sumidero de instalaci n rapida 2944RP Installation Operation Parts Installation Fonctionnement Pi ces Instalaci n Operaci n Piezas For further operating Pour plus de renseignements Para mayor informaci n sobre installation or maintenance concernant l utilisation el funcionamiento instalaci n o assistance l installation ou l entretien mantenimiento de la bomba Call 1 800 468 7867 Composer le 1 800 468 7867 Llame al 1 800 468 7867 1 800 546 7867 1 800 546 7867 1 800 546 7867 English oononmomono Pages 2 7 Fran ais com Pages 8 12 Espa ol Paginas 13 19 SIM884 2 5 10 Specifications and Safety DESCRIPTION This Submersible Sump Pump is designed for home sumps Unit is equipped with a 3 prong grounding type power cord Shaded pole motor is oil filled and sealed for cooler running Sleeve bearings on motor shaft never need lubrication Automatic reset thermal protection Not designed for use as a swimming pool drainer SPECIFICATIONS Power supply required ooo 115V 60 HZ Liquid Temp Range 32 F to 70 F 0 21 C Individual Branch Circuit Required min 15 Amps Discharge Check Valve
4. Amp amp res Marche Arr t 2944RP 1 2 5 5 15 203 8 89 3 5 RENSEIGNEMENTS CONCERNANT LES CONSIGNES DE S CURIT G N RALES Si elle est bien install e bien entretenue et bien utilis e une lectropompe assure de nombreuses ann es de ser vice sans entretien Toutefois toutes circonstances inhab ituelles interruption du courant alimentant la pompe salet s ou d bris dans le puisard d bits de crue d pas sant la capacit de la pompe pannes lectriques ou m caniques de la pompe etc peuvent emp cher la pompe de fonctionner normalement Pour emp cher les d g ts caus s par l eau suite une inondation s adresser au d taillant sur la possibilit de poser une deuxi me pompe de puisard fonctionnant sur le courant alternatif ou une pompe de puisard de secours fonctionnant sur le courant continu et ou une alarme de niveau lev d eau Se reporter au Tableau de recherche des pannes de ce Manuel pour plus de renseignements concernant les probl mes courants des pompes de puisard et leurs rem des Pour de plus amples renseignements s adresser au d taillant ou tien le service a la clien t le en composant le 1 800 468 7867 1 Avant tout il faut conna tre applications de la pompe ces limites et les dangers potentiels que pr sente son utilisation 2 Ne pas utiliser cette pompe s il y a pr sence de poissons dans l eau Une fuite d huile provenant du moteur pourrait tu
5. empreinte cruciforme n 8 32 x 5 8 de pouce 4 Tt 5 Impulseur 1 RP0000911A 6 Volute inf rieure 1 PS1 30P 7 Vis t te cylindrique n 8 16 x 1 2 po de long 7 t 8 Adaptateur de 1 1 4 po NPT x 1 1 4 po coulissant 1 Tt 9 Collier de l interrupteur 1 Tt 10 Interrupteur a flotteur vertical comprend la r f 9 1 FPS17 66 11 Adaptateur 1 1 4 po NPT x 1 1 2 po coulissant 1 Tt 12 Raccord cannel de 1 1 4 po NPT x 1 1 4 po 1 t e N cessaire de tuyau souple de 1 1 4 po x 24 pi comprend la r f 12 1 FP0012 6U P2 Si le moteur tombe en panne Replacer la pompe Articles de quincaillerie standard A acheter localement e Pi ce non illustr e Pour les services des pi ces ou d assistance appeler le service la client le Simer en composant le 800 468 7867 1 800 546 7867 Diagnostic des pannes LOCALISATION DES PANNES 12 Sympt me Cause s probable s Mesure corrective La pompe ne d marre pas ou ne tourne pas La pompe n est pas branch e Niveau d eau trop bas Fusible fondu Basse tension de la ligne Moteur d fectueux Interrupteur du moteur d fectueux Roue motrice Entrave trop longue Obstruction du flotteur S assurer que la pompe est branch e dans une prise de courant ad quate Linterrupteur de la pompe ne se d clenche pas si l eau ne recouvre pas la partie sup rieure de la pompe Si le fusible est fondu remplacer par le calibre qui
6. 800 546 7867 Fonctionnement FONCTIONNEMENT AVERTISSEMENT Risque de secousses lec triques Ne pas toucher la pompe ni au moteur de la pompe lorsqu on a les mains humides ou lorsqu on se tient debout sur une surface mouill e humide ou dans l eau 1 Le joint de l arbre d pend de l eau pour son grais sage Ne pas utiliser la pompe si elle n est pas immerg e dans l eau sinon son joint sera endom mag si la pompe fonctionne sec 2 Le moteur est quip d un protecteur thermique r armement automatique Si la temp rature devait s lever anormalement le disjoncteur interrompra automatiquement l arriv e de courant avant que le moteur soit endommag Lorsque le moteur aura suffisamment refroidi le disjoncteur se r armera automatiquement et le moteur red marrera Si le 10 protecteur se d clenche constamment sortir la pompe du puisard et en d terminer la cause Une basse tension des cordons prolongateurs trop longs un impulseur bouch une hauteur de refoule ment tr s basse ou un tuyau de refoulement bouch ou gel etc risquent de causer un fonctionnement intermittent 3 La pompe n aspirera pas toute l eau Si on fait fonc tionner la pompe manuellement et que brusque ment l eau ne coule plus par son tuyau de refoule ment arr ter imm diatement la pompe Le niveau de l eau est probablement tr s bas et la pompe s est d samorc e AVERTISSEMENT Risque de chocs
7. ainsi que l impulseur Si la tension est au dessous du minimum recommand v rifier la force du c blage provenant de l interrupteur g n ral de l habitation S il n y a pas de probl me contacter la Compagnie d lectricit D monter la pompe et nettoyer l impulseur Nettoyer la roue motrice si elle est obstru e autrement remplacer la pompe Utiliser un clou ou un trombone pour ouvrir le trou d vent dans le tuyau de refoulement D poser la pompe et nettoyer la cr pine d aspiration ainsi que l impulseur S assurer que le clapet antiretour est install correctement Pour les services des pi ces ou d assis tance appeler le service la client le Simer en composant le 1 800 468 7867 1 800 546 7867 Garantie 13 CONSERVER L ORIGINAL DU RE U POUR TOUTE REFERENCE ULT RIEURE GARANTIE LIMIT E SIMER garantit l acheteur au consommateur d origine l Acheteur que ses produits sont exempts de tout vice de mat riau et de fabrication Cette garantie est valable pendant douze 12 mois partir de la date d achat d origine Si dans les douze 12 mois suivant la date d achat d origine un produit se r v le d fectueux il sera r par ou remplac la discr tion de SIMER conform ment aux modalit s et conditions expos es ci dessous Le re u de lachat d origine et l tiquette d information sur la garantie sont requis pour d terminer la recevabilit de la r clamation au t
8. de puesta a tierra Para refacciones o asistencia llame a Simer Servicios al Cliente al 800 468 7867 800 546 7867 Instalaci n Para reducir el riegso de ADVERTENCIA choque el ctrico desenchufe la bomba antes de repararla No se ha comprobado a n si esta bomba pueda ser usada en albercas La bomba es suministrada con un conductor de puesta a tierra y un enchufe del tipo de puesta a tierra Aseg rese de que sea conectado solamente a un tomacorriente puesto a tierra del tipo de puesta a ierra Si el tomacorriente mural es del tipo para 2 clavi jas ste debe ser reemplazado por un tomacorri ente de 3 clavijas e instalado de acuerdo con los c digos y reglamentos que correspondan 15 AVISO No use obturador de juntas de tuber a en las tuber as de pl stico El obturador de juntas de tuber a puede da ar el pl stico ACUIDADO Riesgo de inundaci n Si se usa la manguera de descarga flexible aseg rese de que la bomba est bien inmobilizada para que no pueda moverse dentro del sumidero i la bomba no est bien firme puede moverse y causar interferencia con el interruptor e impedir que la bomba se ponga en marcha o se detenga Fuente de Alimentaci n La bomba est dise ada para funcionar con corriente de 115 V 60 Hz y requiere un ramal individual m nimo de 15 amps 13 Todo el cableado debe ser efectuado por un elec Tanto la bomba como el inte
9. las siguientes situaciones 1 caso de fuerza mayor 2 productos que a s lo juicio de SIMER hayan sido sometidos a negligencia abuso accidente mala aplicaci n manejo indebido o alteraciones 3 fallas debido a instalaci n operaci n mantenimiento o almacenamiento inadecuados 4 aplicaciones usos o servicios que no sean normales o aprobados 5 fallas provocadas por corrosi n herrumbre u otros materiales extra os en el sistema o una operaci n a presiones que excedan los m ximos recomendados Esta garant a establece la nica obligaci n de SIMER y el recurso exclusivo del Comprador con respecto a los productos defectuosos SIMER NO SE HAR RESPONSABLE DE NING N DA O CONSECUENTE INCIDENTAL O CONTINGENTE LAS GARANT AS QUE ANTECEDEN SON EXCLUSIVAS Y REEMPLAZAN TODA OTRA GARANT A EXPL CITA O IMPLICITA INCLUYENDO PERO SIN LIMITARSE A LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD E _ IDONEIDAD PARA UN FIN ESPEC FICO LAS GARANT AS QUE ANTECEDEN NO SE EXTENDER N M S ALLA DE LA DURACI N PROVISTA EN LA PRESENTE Algunos Estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes o de limitaciones de tiempo sobre garant as impl citas de modo que es posible que las limitaciones o exclusiones que preceden no correspondan en su caso Esta garant a le otorga derechos legales espec ficos y es posible que Usted tambi n tenga otros derechos que pueden variar de un Estado al otro SIMER 293 Wright St
10. lectriques Avant de v rifier pourquoi cette pompe a cess de fonctionner interrompre le courant parvenant la pompe Bo tier de fixation du support Dan ee Axe ee Flotteur __ But e Tige de tige l interrupteur AT TA Remplacement de l interrupteur vertical N A Support O Monter le support dans le bo tier de l interrupteur Glisser le flotteur puis la but e sur la tige apr s la deuxi me pointe Introduire la tige dans le bo tier de l interrupteur puis le verrouiller en place avec l axe NOTA S assurer que l axe retient bien la tige dans le bo tier de l interrupteur sinon la pompe ne s arr tera pas Qo l interrupteur au tuyau de refoule ment comme il est illustr Le dessous du support devrait tre situ 7 1 4 po au dessus de la partie sup rieure de la volute pour fixer les bons points marche arr t voir ci dessous 7 1 4 NOTA Se reporter aux instructions incluses avec l interrupteur de rechange num ro de pi ce FPS17 66 Pour les services des pi ces ou d assistance appeler le service la client le Simer en composant le 1 800 468 7867 1 800 546 7867 Pi ces de rechange Il MODELE 2944RP 6131 1209 R f D signation Qt 2944RP 1 Ensemble de cord n lectrique 1 PS117 54 TSU 2 Moteur 1 an 3 Volute sup rieure 1 PS1 31P 4 Vis t te cylindrique
11. 1 4 above the top of the volute for correct on off points see below 7 1 4 NOTICE See instructions included with replacement switch Part Number FPS17 66 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Repair Parts 5 MODEL 2944RP 6131 1209 Key Part Description Qty 2944RP Power Cord Assembly PS117 54 TSU Motor Volute Upper Screw 8 32x5 8 Phillips Pan Head Impeller Volute Lower Screw 8 16x1 2 Lg Pan Head 1 1 4 NPT x 1 1 4 Slip Adapter Switch Clamp 10 Vertical Float Switch Assembly includes Key No 9 11 1 1 2 Slip x 1 1 4 NPT Adapter 12 1 1 4 NPT x 1 1 4 Hose Barb e 1 1 4 x 24 Hose Kit includes Key No 12 PS1 31P RP0000911A PS1 30P FPS17 66 J O O1 AUN 5 FP0012 6U P2 ES a EET AAA AS If motor fails replace entire pump t Standard hardware item purchase locally e Not illustrated For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Troubleshooting TROUBLESHOOTING CHART SYMPTOM PROBABLE CAUSE S CORRECTIVE ACTION Pump won t start or run Pump is not plugged in Blown fuse Low line voltage Defective motor Defective float switch Impeller Float obstructed Check and see if pump is plugged in to a proper outlet f blown replace with fuse of p
12. amaged if allowed to run dry 2 Motor is equipped with automatic reset thermal protector If temperature in motor should rise unduly switch will cut off all power before dam age can be done to motor When motor has cooled sufficiently switch will reset automatically and restart motor If protector trips repeatedly pump should be removed and checked as to cause of difficulty Low voltage long extension cords clogged impeller very low head or lift or a plugged or frozen discharge pipe etc could cause cycling 3 Pump will not remove all water If operating a pump manually and suddenly no water comes out of the discharge hose shut off the unit immediately The water level is probably very low and the unit has broken prime WARNING Risk of electric shock Before attempting to check why unit has stopped operating disconnect power from unit Switch Housing 8 Bracket AT a gt SS o Mounting Ss Screws Rod Stop Rod gs Vertical Switch Replacement Ne Bracket O Mount the bracket on the switch housing Slip the float and then the rod stop onto the rod past the second nib Insert the rod assembly up into the switch housing and lock into place with the pin NOTICE Be sure the pin holds the rod in the switch housing or the pump will not shut off Attach the switch to the discharge pipe as shown The bottom of the bracket should be 7
13. convient Si la tension est au dessous du minimum recommand v rifier la force du c blage provenant de l interrupteur g n ral de l habitation S il n y a pas de probl me contacter la Compagnie d lectricit ou les services hydro lectriques Remplacer la pompe Remplacer l interrupteur du moteur Si la roue refuse de tourner d poser la partie inf rieure de la pompe et cherche la cause du blocage Raccourcir l entrave D gager le mouvement du flotteur La pompe d marre et Reflux du liquide dans Installer un clapet de retenue La pompe fonctionne mais elle ne d livre pas ou peu d eau Diminution du refoulement obstruction ou glace dans la tuyauterie Entrave trop longue Obstruction du flotteur La cr pine d aspiration est obstru e Basse tension de la ligne Quelque chose bloque la rouemotrice Pi ces us es ou d fectueuses ou roue motrice obstru e Trou d vent bouch La cr pine d aspiration est obstru e Le clapet antiretour est install l envers s arr te trop souvent la pompe Interrupteur du flotteur Remplacer l interrupteur du flotteur d fectueux La pompe refuse de Interrupteur du flotteur Remplacer l interrupteur du flotteur s arr ter d fectueux D poser la pompe et nettoyer la pompe et la canalisation Raccourcir l entrave D gager le mouvement du flotteur D poser la pompe et nettoyer la cr pine d aspiration
14. da correctiva tan pronto como sea razonablemente posible No se aceptar n solicitudes de servicio si se reciben m s de 30 d as despu s del vencimiento de esta garant a Esta garant a no es v lida para productos que se utilicen para fines comerciales o de alquiler BOMBAS CLOACALES NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba e Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda minorista e Descarte la bomba cumpliendo con todas las normas locales que correspondan para su eliminaci n Excepciones para la Garant a Limitada de Doce 12 Meses Producto Per odo de garant a BW85P CM10 CMK M40 M40P 90 d as 2300 2310 2330 2520ULST 2943 2955 2956 2957 2960 502355 A5500 2 a os Bombas de pozo sumergibles de 4 2945 2958 2975PC 2985 3075SS 3983 3984 3 a os Tanque precargado del sistema de agua 3985 3986 5 a os 3963 3988 3995 3997 De por vida T rminos y condiciones generales Usted deber pagar por todos los gastos de mano de obra y de env o necesarios para reemplazar el producto cubierto por esta garant a Esta garant a no se aplicar en
15. e lectrique observer tous les codes de s curit et de l lectricit applicables 12 Cet quipement ne fonctionne que sur le courant 115 volts monophas et est muni d un cordon d alimentation approuv 3 conducteurs et d une fiche 3 broches dont une de mise la terre Pour les services des pi ces ou d assistance appeler le service la client le Simer en composant le 800 468 7867 1 800 546 7867 Installation Avant d intervenir sur la AVERTISSEMENT pompe et pour minimiser les risques de chocs lectriques d brancher la pompe de la prise de courant Aucune tude n a t faite pour savoir si cette pompe pouvait tre utilis e aux alentours des piscines Cette pompe est livr e avec un conducteur et une fiche comportant une broche de mise la terre Ne brancher cette fiche que dans une prise de courant ad quatement mise la terre Au cas o l installation ne comporterait que des pris es de courant 2 trous remplacer la prise dans laquelle la fiche sera branch e par une prise de courant 3 trous ad quatement mise la terre et pos e conform ment aux Codes et aux d crets applicables 13 Tout le c blage doit tre ex cut par un lectricien qualifi 14 S assurer que la source du courant est conforme aux caract ristiques de l quipement 15 Prot ger le cordon lectrique contre les objets tran chants les surfaces chaudes l huile et les produits chimiques vi
16. e la pompe en remplissant le puisard d eau puis observer le fonctionnement de la pompe sur un cycle complet Pour conna tre les r glages de l interrupteur se reporter au tableau de la page 8 intitul Caract ristiques lectriques et de l in terrupteur INSTALLATION oe a eS 1 Dans le cas de mod les quip s d un interrupteur verti AVERTISSEMENT Ne pas proc der a cette veri cal installer la pompe dans un puisard ayant un diam tre risque de causer un mauvais fonctionnement une minimum de 25 4 cm 10 pouces Le puisard doit avoir panne pr matur e voire une inondation une profondeur minimum de 25 4 cm 10 po Le puis ard peut tre construit avec un tuyau en ciment du b ton en acier ou du plastique Consulter les codes municipaux pour connaitre le mat riau approuv et pour proc der ad quatement l installation 2 Installer la pompe dans le puisard de fa on que le m canisme actionnant l interrupteur puisse avant le plus grand d gagement possible 3 Il ne faut pas poser la pompe sur une surface en argile en terre ou sablonneuse Enlever les petites pierres et le gravier du puisard qui risqueraient de boucher la pompe La cr pine d admission d eau de la pompe doit toujours tre d gag e M E l DuPont De Nemours and Company Corporation Delaware Pour les services des pi ces ou d assistance appeler le service la client le Simer en composant le 800 468 7867 1
17. eje del motor nunca necesitan lubricaci n Protecci n de reposici n t rmica autom tica No se ha dise ado para usar como bomba de desag e para piscinas de nataci n ESPECIFICACIONES Fuente de alimentaci n ooociccicinicin 115 V 60 Hz Gama de la Temperatura del LIQUIdO 3 252224n8 estate 0 21 C 32 F a 70F Requiere un ramal individual minimo 15 Amps Tuber a de Descarga V lvula de retenci n 1 1 4 corrediza 1 1 2 corrediza MANQUE nee en 1 1 4 AVISO No reduzca el tama o de la tuber a o de la manguera de descarga a un di metro menor de 1 1 4 Si la descarga es demasiado peque a la bomba se reca lentar y fallara prematuramente AVISO Este aparato no est dise ado como bomba de cascada o fuente ni para aplicaciones con agua salada o de mar El uso con cascadas fuentes agua salada o de mar anular la garant a Bombee solamente agua con esta bomba No usar en donde hay recirculaci n de agua No ha sido dise ado para usar como desaguador de pisci nas de nataci n RENDIMIENTO GPH LPH A ALTURA TOTAL EN PIES M 1 5 m 3m 4 6 m Sin caudal Serie HP pi 10pi 15 pi enal altura CAPACIDAD EN GALONES POR HORA ig 12113 10220 7571 7 3m 2944RP 1 2 3200 2700 2000 24 pi ESPECIFICACIONES ELECTRICAS Y DEL INTERRUPTOR Amperios con el Require un Ajuste del motor a ramal interruptor en plena individual pu
18. ement mise la terre ou un cir cuit lectrique ad quatement mis la terre par exemple Ne jamais couper la broche ronde de mise la terre de la fiche debout sur une surface mouill e humide ou dans l eau AVERTISSEMENT Tension dangereuse Risque de secousses de br leres voire de mort Si le sol du sous sol est humide ou couvert d eau ne pas marcher sur cette surface humide tant que toute l alimentation en courant lectrique n a pas t inter rompue Si le sectionneur principal se trouve au sous sol appeler la compagnie qui fournit l lectricit pour lui demander d interrompre le service parvenant la maison ou appeler le service d incendie local pour plus de renseignements D poser la pompe la r parer ou la remplacer On risque d tre mortellement lectrocut si l on n observe pas cet avertissement Ne pas lever la pompe par son cordon lectrique 5 Si la conduite de refoulement de la pompe est expos e aux temp ratures de cong lation ext rieures la partie expos e doit tre install e de fa on que l eau restant dans le tuyau puisse se vidanger en retombant par gravit Si l on ne respecte pas cette recommandation l eau emprisonn e dans la conduite de refoulement risque de geler et la pompe risque d tre endommag e 6 Apr s avoir install la tuyauterie le clapet antiretour et l interrupteur flotteur la pompe est pr te fonctionner 7 V rifier le fonctionnement d
19. en wiring an electrically driven pump follow all electrical and safety codes that apply 12 This equipment is only for use on 115 volt sin gle phase and is equipped with an approved 3 conductor cord and 3 prong grounding type plug For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Installation and Operation WARNING To reduce risk of electric shock pull plug before ser vicing This pump has not been investigated for use in swimming pool areas Pump is supplied with a grounding conductor and grounding type attachment plug Be sure it is connected only to a properly grounded grounding type receptacle Where a 2 prong wall receptacle is encoun tered it must be replaced with properly grounded 3 prong receptacle installed in accor dance with codes and ordinances that apply 13 All wiring should be performed by a qualified electrician 14 Make certain power source conforms to require ments of your equipment 15 Protect electrical cord from sharp objects hot surfaces oil and chemicals Avoid kinking cord Replace or repair damaged or worn cords imme diately 16 Do not touch an operating motor Modern motors can operate at high temperatures 17 Do not handle pump or pump motor with wet hands or when standing on wet or damp surface or in water WARNING Hazardous voltage can shock burn or kill If your basement has water or moisture on floor do not walk on w
20. er les poissons Avant d intervenir sur la pompe couper le courant Dissiper toute la pression du circuit d eau avant d intervenir sur un des l ments de la pompe Vidanger l eau du circuit avant d intervenir sur la DN Po pompe Bien immobiliser la canalisation de refoulement avant de faire fonctionner la pompe Une canalisation de refoulement non immobilis e risque de se d placer comme un fouet et de causer des blessures corporelles et ou des dommages mat riels 7 Avant chaque utilisation s assurer que les tuyaux souples ne comportent pas de points faibles ni de parties us es et que tous les raccords sont bien serr s 8 P riodiquement inspecter la pompe et tous les l ments de l ensemble Proc der un entretien p riodique selon le besoin 9 Pr voir un moyen de dissiper la pression des pompes dont la canalisation de refoulement peut tre ferm e ou obstru e 10 S curit personnelle a Lorsque l on intervient sur une pompe toujours porter des lunettes de s curit b Toujours garder la zone de travail propre d gag e et bien clair e Enlever tous les outils et tout l quipement inutiles c Les visiteurs doivent se tenir une distance s cu ritaire de la zone de travail d Poser des cadenas pour s assurer que les enfants ne pourront pas p n trer dans l atelier de travail Poser aussi un interrupteur g n ral et enlever les cl s des d marreurs 11 Lorsque l on c ble une pomp
21. eratura en el motor se elevara indebidamente el interruptor puede cortar toda la energ a antes de que se produzca da o al motor Cuando el motor se ha enfriado suficientemente el interruptor se reposi cionar autom ticamente y el motor volver a pon erse en marcha Si el protector se desengancha en forma continua la bomba debe ser sacada y revisa da para verificar cual es el problema Baja tensi n cables de alargue largos impulsor atascado muy baja altura de aspiraci n o elevaci n o una tuber a de descarga tapada o congelada etc pueden hacer que se pase por el ciclo Riesgo de choque el ctrico Reemplazo del interruptor vertical MK M nsula O Coloque la m nsula sobre la envoltura del interruptor Envoltura Deslice el flotador y luego el tope del de vara por la vara pasando el interruptor segundo pico Introduzca la unidad de la varilla dentro de la envoltura del interruptor y tr bela en posici n con el pasador PE Po gS AVISO Asegurese de que el pasador Sg de montaje sostenga la varilla dentro de la envoltura Sa de la del interruptor de lo contrario la bomba 5 m nsula no se apagar O Fije el interruptor a la tuber a de descarga seg n se ilustra La parte inferior de la m nsula deber estar a 7 1 4 por encima A de la parte superior de la voluta para que y los puntos de encender apagar on off ib queden en la posici n correcta
22. et area until all power has been turned off If shut off box is in basement call electric company or hydro authority to shut off service to house or call your local fire department for instructions Remove pump and repair or replace Failure to follow this warning can result in fatal electrical shock Do not lift pump by power cord INSTALLATION 1 Install pump in sump pit with minimum diameter of 10 254mm Sump depth should be 10 254mm Construct sump pit of tile concrete steel or plastic Check local codes for approved materials and for proper installation 2 Install pump in pit so that switch operating mechanism has maximum possible clearance 3 Pump should not be installed on clay earth or sand surfaces Clean sump pit of small stones and gravel which could clog pump Keep pump inlet screen clear NOTICE Do not use ordinary pipe joint com pound on plastic pipe Pipe joint compound can attack plastics CAUTION Risk of flooding If the flexi ble discharge hose is used make sure pump is secured in sump to prevent movement Failure to secure pump may allow pump movement switch interference and pre vent pump from starting or stopping Power Supply Pump is designed for 115 V 60 Hz operation and requires a minimum 15 amp individual branch circuit Both pump and switch are supplied with 3 wire cord sets with ground ing type plugs Switch plug is inserted directly
23. ice at 1 800 468 7867 1 800 546 7867 Warranty 7 RETAIN ORIGINAL RECEIPT FOR YOUR RECORDS LIMITED WARRANTY SIMER warrants to the original consumer purchaser Purchaser or You of its products that they are free from defects in material and workmanship for a period of twelve 12 months from the date of the original consumer purchase If within twelve 12 months from the original consumer purchase any such product shall prove to be defective it shall be repaired or replaced at SIMER s option subject to the terms and conditions set forth below The original purchase receipt and product warranty information label are required to determine warranty eligibility Eligibility is based on purchase date of original product not the date of replacement under warranty The warranty is limited to repair or replacement of product only Purchaser pays all removal installation labor shipping and incidental charges For parts or troubleshooting assistance DO NOT return product to your retail store Contact SIMER Customer Service at 1 800 468 7867 1 800 546 7867 Claims made under this warranty shall be made by returning the product except sewage pumps see below to the retail outlet where it was purchased immediately after the discovery of any alleged defect SIMER will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the war
24. into outlet and pump plug inserts into opposite end of switch plug WARNING Pump should always be elec trically grounded to a suit able electrical ground such as a grounded water pipe or a properly grounded metallic raceway or ground wire system Do not cut off round ground pin If pump discharge line is exposed to outside sub freezing atmosphere portion of line exposed must be installed so any water remaining in pipe will drain to the outfall by gravity Failure to do this can cause water trapped in discharge to freeze which could result in damage to pump After piping check valve and float switch have been installed the unit is ready for operation Check the pump operation by filling sump with water and observing pump operation through one complete cycle For switch settings see the Electrical and Switch Specifications chart on Page 2 WARNING Failure to make this opera tional check may lead to improper operation premature failure and flooding E l DuPont De Nemours and Company Corporation Delaware For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Operation OPERATION WARNING Risk of electric shock Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water 1 Shaft seal depends on water for lubrication Do not operate pump unless it is submerged in water as seal may be d
25. itre de la garantie La recevabilit de la r clamation se base sur la date de l achat d origine du produit et non sur la date d un ventuel remplacement sous garantie La garantie est limit e la r paration ou au remplacement du produit uniquement L Acheteur assume les frais de retrait d installation de transport et tous les frais accessoires Pour obtenir des pi ces ou de l aide technique NE PAS retourner le produit au d taillant Contacter le service la client le de SIMER au 1 800 468 7867 1 800 546 7867 Les r clamations au titre de cette garantie doivent tre effectu es en retournant le produit l exception des pompes d eaux d gout voir ci dessous au d taillant o il a t achet et ce imm diatement apr s la d couverte de la d faillance suppos e SIMER prendra les mesures correctives n cessaires dans un d lai rapide et raisonnable Aucune demande de r paration ne sera accept e plus de 30 jours apr s l expiration de la garantie Cette garantie ne s applique pas aux produits utilis s des fins commerciales ou de location POMPES D EAUX D GOUT NE PAS RETOURNER une pompe d eaux d gout qui a t install e au d taillant Communiquer avec le service la client le de SIMER Les pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout e Porter des gants en caoutchouc pour manipuler la pom
26. l Comprador o Usted de sus productos que stos estar n libres de defectos en materiales y en mano de obra por un per odo de doce 12 meses a partir de la fecha de la compra original del consumidor Si dentro de los doce 12 meses a partir de la fecha de la compra inicial del consumidor se comprueba que cualquiera de esos productos es defectuoso ste ser reparado o reemplazado a la discreci n de SIMER sujeto a los t rminos y a las condiciones indicadas a continuaci n Se necesitar su recibo de compra original y la etiqueta de informaci n sobre la garant a del producto para determinar la admisibilidad de la garant a La admisibilidad se basa en la fecha de compra del producto original no en la fecha de reemplazo bajo la garant a La garant a est limitada a la reparaci n o el reemplazo del producto solamente El comprador pagar todos los costos de remoci n instalaci n mano de obra y env o necesarios as como todo costo adicional asociado Si necesita piezas o resoluci n de problemas NO regrese el producto a la tienda minorista Llame el Servicio a la Clientela de SIMER al 1 800 468 7867 1 800 546 7867 Las reclamaciones bajo esta garant a se deber n realizar mediante la devoluci n del producto excepto en el caso de las bombas cloacales ver a continuaci n a la tienda minorista en donde se haya adquirido inmediatamente despu s de haber descubierto un supuesto defecto SIMER entonces tomar la medi
27. lgadas mm Modelo HP carga amperios Marche Arr t 2944RP 1 2 5 5 15 8 203 3 5 89 14 INFORMACION GENERAL SOBRE SEGURIDAD Las bombas de sumidero el ctricas por lo regular duran muchos a os sin sufrir problemas de servicio cuando son instaladas mantenidas y usadas correctamente Sin embargo las situaciones inusuales interrupci n del suministro el ctrico que va a la bomba tierra o suciedad en el sumidero inundaci n superior a la capacidad de la bomba fallas el ctricas y mec nicas etc pueden evitar que su bomba funcione como acostumbra Para evitar posibles da os ocasionados por inundaci n de agua consulte a su representante de ventas sobre la insta laci n de una bomba de sumidero con CA secundaria una bomba de sumidero de respaldo con CD y o una alarma de alto nivel de agua Consulte la Tabla de solu ci n de problemas contenida en este manual para infor maci n sobre problemas comunes de la bomba de sum idero y soluciones Para mayor informaci n visite a su representante de ventas o llame al Departamento de Servicio al Cliente 1 800 468 7867 1 Inf rmese sobre la aplicaci n limitaciones y posi bles riesgos de la bomba 2 No use esta bomba en agua con peces Si hay una fuga de aceite del motor puede matar a los peces 3 Desconecte la energ a el ctrica antes de efectuar reparaciones 4 Alivie toda la presi n dentro del sistema antes de reparar cualquier co
28. miques Elle n est pas con ue pour vider les piscines CARACTERISTIQUES Courant d alimentation requis 115 V 60 Hz Gammes de temp ratures du liquide de 0 21 C 32 F 70 F Circuit de d rivation individuel requis MINIMUM cortesana 15 amp res Refoulement Clapet antiretour 1 1 4 po coulissant 1 1 2 po coulissant TUYAU SOUPIR 255 ec remaniement 1 1 4 po REMARQUE S assurer que le diam tre du tuyau de refoulement est d au moins 3 2 cm Si le refoulement est trop petit il y aura surchauffement et panne pr matur e de la pompe NOTA Cette pompe n est pas con ue pour tre utilis e en tant que pompe de fontaine ou de chute d eau ni dans des eaux sal es ou de saumure Son utilisation avec une chute d eau une fontaine de l eau sal e ou de saumure annulera la garantie Ne pomper que de l eau avec cette pompe Ne pas utiliser o de l eau recircule Cette pompe n est pas con ue pour vider les piscines RENDEMENT LITRES PAR HEURE A LA HAUTEUR TOTALE DE REFOULEMENT EN METRES 15m 3m 46m Aucun S rie Puiss 5 pi 10 pi 15 pi d bit la VOLUME LITRES GL HEURE ne 12113 10220 7571 7 3m PRE 1 2 3200 2700 2000 24 pi CARACTERISTIQUES ELECTRIQUES ET DE COMMUTATION Circuit de Charge d rivation R glage de compl te individuel l interrupteur moteur requis en en mm po S rie Puiss
29. mponente 5 Drene toda el agua del sistema antes de efectuar reparaciones 6 Asegure bien la tuber a de descarga antes de poner en marcha la bomba Una tuber a de descarga que no est bien segura puede moverse y causar lesiones personales y o da os materiales 7 Antes de cada uso verifique si las mangueras est n d biles o gastadas asegur ndose de que todas las conexiones est n firmes 8 Inspeccione peri dicamente el sumidero la bomba y los componentes del sistema Mant ngala limpia de basuras y objetos extra os Realice el mantenimien to de rutina como sea necesario 9 Provea un medio de alivio de la presi n para aquel las bombas cuya tuber a de descarga puede blo quearse u obstruirse 10 Seguridad Personal a Use lentes protectores en todo momento cuando trabaje en la bomba b Mantenga el lugar de trabajo limpio despejado y debidamente iluminado guarde todas her ramientas y el equipo que no se use c Mantenga a los visitantes a una distancia segura del lugar de trabajo d Aseg rese de que su taller sea a prueba de ni os con candados interruptores maestros y sacando las llaves del arrancador 11 Cuando instale el cableado de una bomba accionada el ctricamente siga todos los c digos el ctricos y de seguridad que correspondan 12 Esta bomba solamente se puede usar con corri ente de 115 voltios monof sica y est equipado con un cord n aprobado de 3 conductores y 3 clav ijas del tipo
30. no llame a la compa a el ctrica o a la compa a de electricidad para cortar el servicio a su casa o llame al departamento de bomberos de su localidad para solicitar instrucciones Saque la bomba y rep rela o reempl cela 6 El incumplimiento de esta advertencia puede resultar en un choque el ctrico mortal No levante la bomba por medio del cord n de corriente 7 tuber a se drene por gravedad hacia la descarga El incumplimiento de sto puede causar que el agua atrapada en la tuber a de descarga se congele lo cual podr a resultar en da o para la bomba Despu s de haber instalado la tuber a la v lvula de retenci n y el conmutador a flotador la unidad est lista para funcionar Verifique el funcionamiento de la bomba llenando el sumidero con agua y observando el funcionamiento de la bomba por un ciclo completo Para las gradua ciones del interruptor consulte el gr fico de Especificaciones El ctricas y del Interruptor que aparece en la p gina 14 El incumplimiento de esta ver ADVERTENCIA ificacion del funcionamiento puede resultar en funcionamiento impropio falla prematura e inundaci n E l DuPont De Nemours and Company Corporation Delaware INSTALACION 1 Instale la bomba en un foso de recogida con un di metro m nimo de 10 254 mm La profundidad del sumidero debe ser de 10 254 mm Construya el foso de recogida de losetas hormig n acero o pl stico Confirme los materiales apr
31. o m voltaje de l nea es demasiado bajo El motor est defectuoso El interruptor del flotante est defectuoso El rodete no gira El brazo del flotador es demasiado largo El movimiento del flotante est obstruido S NTOMA CAUSA PROBABLE MEDIDA CORRECTIVA La bomba no arranca La bomba no est enchufada Verifique que la bomba est enchufada en un tomacorriente ni funciona adecuado El interruptor de la bomba no se conecta a menos que el agua cubra la parte superior de la bomba Si el fusible est quemado sustit yalo con un fusible de la capacidad correcta Si el voltaje est por debajo del m nimo recomendado verifique en el edificio el di metro del alambre desde el interruptor principal Si es el correcto comun quese con la empresa de electricidad o la autoridad hidroel ctrica Reemplace la bomba Reemplace el interruptor del flotante Si el rodete no gira saque el cuerpo inferior de la bomba y ubique el lugar donde el rodete se traba Acorte el brazo del flotante Retire las obstrucciones La bomba se pone en marcha y se detiene con demasiada frecuencia Hay retroceso de agua de a tuber a El interruptor del flotante est fallado Instale una v lvula de retenci n Reemplace el interruptor del flotante La bomba no se desconecta Interruptor defectuoso del flotante Descarga obstruida obst culos o hielo en las tuber as brazo del flotante es demasiad
32. o largo El movimiento del flotante est obstruido m Tamiz de admisi n restringido Reemplace el interruptor del flotante Retire la bomba y limpie la bomba y la tuber a Acorte el brazo del flotante Retire las obstrucciones Saque la bomba y limpie el tamiz de admisi n y el impulsor La bomba funciona pero el caudal es reducido o nulo El voltaje de l nea es baja Algo se ha quedado trabado en el rodete El rodete tiene piezas desgastadas o defectuosas Orificio de ventilaci n obturado Tamiz de admisi n restringido Verifique que la v lvula no est instalada hacia atr s o invertida Si el voltaje es inferior al m nimo recomendado verifique el di metro del alambre que va desde el interruptor principal en el edificio Si es el correcto comun quese con la empresa de electricidad Saque la bomba y limpie el impulsor Limpie el rodete si est taponado en caso contrario reemplace la bomba Use un clavo o un clip sujetapapeles para abrir el orificio de ventilaci n en la tuber a de descarga Saque la bomba y limpie el tamiz de admisi n Aseg rese de que la v lvula de retenci n est debidamente instalada Para refacciones o asistencia llame a Simer Servicios al Cliente al 800 468 7867 800 546 7867 Garantia 19 GUARDE EL RECIBO ORIGINAL PARA CULAQUIER REFERENCIA POSTERIOR GARANTIA LIMITADA SIMER le garantiza al comprador consumidor original e
33. obados y la instalaci n adecuada requeridos por las normas locales 2 Instale la bomba en el pozo de manera que el mecanismo de operaci n del interruptor tenga el mayor juego posible 3 La bomba no debe ser instalada en arcilla tierra o superficies arenosas Saque las piedritas y arenillas que puedan haber en el pozo del sumidero pues pueden obstruir la bomba Mantenga limpio el filtro de admisi n de la bomba Para refacciones o asistencia llame a Simer Servicios al Cliente al 1 800 468 7867 800 546 7867 Funcionamiento 16 FUNCIONAMIENTO 3 La bomba no saca toda el agua La bomba no aspi hd rar toda el agua Si se est operando la bomba en ADVERTENCIA Riesgo de choque el ctrico No forma manual y de repente no sale agua de la manipule la bomba o el motor de manguera de descarga apague la unidad inmediata mente Probablemente el nivel del agua es muy bajo y la unidad ha dejado de cebar la bomba con las manos mojadas o cuando est para do en suelo h medo mojado o en el agua 1 La junta del eje depende del agua para su lubri caci n No haga funcionar la bomba a menos que est sumergida en agua ya que la junta puede ADVERTENCIA Antes de intentar revisar da arse si se hace trabajar en seco porque la bomba ha dejado de funcionar 2 El motor est equipado con un protector contra desconecte la energ a el ctrica sobrecargas t rmicas de reposici n autom tica Si la temp
34. pe e A des fins de garantie retourner l tiquette figurant sur le cordon de la pompe et l original du re u au d taillant e Mettre la pompe au rebut conform ment la r glementation locale Exceptions la garantie limit e de douze 12 mois Produit P riode de garantie BW85P CM10 CMK M40 M40P 90 jours 2300 2310 2330 2520ULST 2943 2955 2956 2957 2960 5023SS A5500 2 ans Pompe pour puits submersibles de 4 pouces 2945 2958 2975PC 2985 3075SS 3983 3984 3 ans R servoir pr charg de syst me d eau 3985 3986 5 ans 3963 3988 3995 3997 vie Modalit s et conditions g n rales LAcheteur doit payer tous les frais de main d uvre et de transport n cessaires au remplacement du produit garanti couvert par cette garantie Cette garantie ne s applique pas ce qui suit 1 Les catastrophes naturelles 2 Les produits qui selon SIMER ont fait l objet d une n gligence d une utilisation abusive d un accident d une mauvaise application ou d une alt ration 3 Les d faillances dues une installation une utilisation un entretien ou un entreposage inappropri s 4 Une application une utilisation ou une r paration atypique ou non approuv e 5 Les d faillances caus es par la corrosion la rouille ou d autres mat riaux trangers au syst me ou par une utilisation une pression sup rieure au maximum recommand Cette garantie tablit la responsabilit unique de SIMER et le reco
35. ranty expires Warranty does not apply to products used in commercial rental applications SEWAGE PUMPS DO NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed e Wear rubber gloves when handling the pump e For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store e Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period BW85P CM10 CMK M40 M40P 90 days 2300 2310 2330 2520ULST 2943 2955 2956 2957 2960 502355 A5500 2 Years 4 Submersible Well Pumps 2945 2958 2975PC 2985 307555 3983 3984 3 Years Pre Charge Water System Tank 3985 3986 5 Years 3963 3988 3995 3997 Lifetime General Terms and Conditions You must pay all labor and shipping charges necessary to replace product covered by this warranty This warranty does not apply to the following 1 acts of God 2 products which in SIMER s sole judgement have been subject to negligence abuse accident misapplication tampering or alteration 3 failures due to improper installation operation maintenance or storage 4 atypical or unapproved application use or service 5 failures caused by corrosion rust or other foreign materials in the system or ope
36. ration at pressures in excess of recommended maximums This warranty sets forth SIMER s sole obligation and purchaser s exclusive remedy for defective products SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU LAR PURPOSE THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to You This warranty gives You specific legal rights and You may also have other rights which vary from state to state SIMER 293 Wright St Delavan WI U S A 53115 Phone 1 800 468 7867 1 800 546 7867 Fax 1 800 390 5351 Web Site http www simerpumps com Caract ristiques et S curit DESCRIPTION Cette pompe de puisard submersible est con ue pour les puisards domestiques Elle est munie d une fiche trois broches dont une de mise la terre Le moteur bague de d phasage est rempli d huile et tanche ce qui lui permet de fonctionner en chauffant moins Les paliers de l arbre du moteur ne requi rent aucun graissage La pompe comporte galement une protection contre les surcharges ther
37. roper size f voltage under recommended minimum check size of wiring from main switch on property If OK contact power company or hydro authority Replace pump Replace float switch f impeller won t turn remove lower pump body and locate source of binding Remove obstruction Pump starts and stops too often Backflow of water from piping Faulty float switch nstall or replace check valve Replace float switch Pump won t shut off Defective float switch Restricted discharge obstacle or ice in piping Float obstructed Restricted intake screen Replace float switch Remove pump and clean pump and piping Remove obstruction Remove the pump and clean the intake screen and the impeller Pump operates but delivers little or no water Low line voltage Something caught in impeller Worn or defective parts or plugged impeller Vent hole plugged Restricted intake screen Check valve is installed either backward or upside down f voltage under recommended minimum check size of wiring from main switch on property If OK contact power company or hydro authority Remove the pump and clean out the impeller Clean impeller if plugged otherwise replace pump Use a nail or paperclip to open vent hole in discharge pipe Remove the pump and clean out the intake screen Be sure check valve is installed correctly For parts or assistance call Simer Customer Serv
38. rruptor vienen con jue tricista calificado l gos de cordones de 3 conductores con enchufes del 14 Aseg rese de que la fuente de alimentaci n cumple tipo de puesta a tierra El enchufe del interruptor se con los requisitos de su equipo enchufa directamente en el tomacorriente y el 15 Proteja el cord n el ctrico contra objetos afilados enchufe de la bomba se enchufa en el extremo superficies calientes aceite y productos qu micos opuesto del enchufe del interruptor Evite que se enrede Reemplace o repare inmediata La bomba siempre debe ser mente un cord n que est da ado o gastado ADVERTENCIA uesta a tierra El una tierra 16 No toque un motor cuando est funcionando Los el ctrica adecuada tales como una tuber a en el motors pete ura a E cas o oar ot an 17 No manipule la bomba o el motor de la bomba con de alambre de puesta a tierra No corte la clavija las manos mojadas o cuando est parado en suelo redonda de puesta a tierra h medo o mojado o en el agua Si la tuber a de descarga de la bomba est expuesta Tensi n peligrosa Puede causar a temperaturas exteriores inferiores al punto de con ADVERTENCIA choques el ctricos quemaduras o gelaci n la porci n expuesta de la tuber a debe ser muerte Si su s tano tiene agua o humedad en el piso no instalada de manera que toda agua que quede en la camine en el lugar mojado hasta que no haya cortado toda la energ a el ctrica Si la llave de paso est en el s ta
39. tailer about a sec ondary AC sump pump a DC backup sump pump and or a high water alarm See the Troubleshooting Chart in this manual for information about common sump pump problems and remedies For more infor mation see your retailer or call customer service at 1 800 468 7867 1 Know the pump application limitations and potential hazards 2 Do not use this pump in water with fish present If any oil leaks out of the motor it can kill fish 3 Disconnect power before servicing 4 Release all pressure within system before servic ing any component 5 Drain all water from system before servicing 6 Secure discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property damage 7 Check hoses for weak or worn condition before each use making certain that all connections are secure 8 Periodically inspect sump pump and system components Keep free of debris and foreign objects Perform routine maintenance as required 9 Provide means of pressure relief for pumps whose discharge line can be shut off or obstructed 10 Personal Safety a Wear safety glasses at all times when working with pumps b Keep work area clean uncluttered and prop erly lighted replace all unused tools and equipment c Keep visitors at a safe distance from work area d Make workshop child proof with padlocks master switches and by removing starter keys 11 Wh
40. ter de nouer le cordon Remplacer imm diatement le cordon s il est endommag ou us 16 Ne pas toucher le moteur de la pompe pendant qu il fonctionne Les moteurs peuvent fonctionner par les temp ratures lev es 17 Ne pas manipuler la pompe ni le moteur de la pompe lorsqu on a les mains humides ou lorsqu on se tient NOTA Ne pas utiliser de p te joint ordinaire pour tuyaux filet s sur les tuyaux en plastique car cette p te attaque les plastiques A ATTENTION Risque d inondation Si l on utilise le tuyau de refoule ment souple s assurer que la pompe est bien immo bilis e dans le puisard pour emp cher qu elle se d place Si la pompe n est pas bien immobilis e elle risque de se d placer l interrupteur risque de se coincer et d emp cher la pompe de d marrer ou de s arr ter Courant lectrique La pompe est con ue pour fonction ner sur le courant lectrique de 115 V 60 Hz et elle doit tre branch e sur un circuit de d rivation individuel d au moins 15 amp res La pompe et l interrupteur sont livr s avec des cordons lectriques 3 conducteurs et des fiches avec broches de terre La fiche de l interrupteur se branche directement dans la prise de courant et la fiche du cordon de la pompe se branche l arri re de la fiche de l interrupteur AVERTISSEMENT La pompe doit toujours tre raccord e la terre sur un tuyau d eau mis la terre une canalisation m tallique ad quat
41. urs exclusif de l Acheteur en cas de produit d fectueux SIMER NE POURRA TRE TENUE RESPONSABLE DE TOUT DOMMAGE INDIRECT OU CONS CUTIF QUEL QU IL SOIT LES PR SENTES GARANTIES SONT EXCLUSIVES ET REMPLACENT TOUTE AUTRE GARANTIE EXPRESSE OU IMPLICITE Y COMPRIS MAIS SANS S Y LIMITER CELLE DE QUALIT MARCHANDE OU D APTITUDE DU PRODUIT UN EMPLOI PARTICULIER LES PR SENTES GARANTIES NE PEUVENT SE PROLONGER AU DEL DE LA P RIODE DE GARANTIE INDIQU E ICI Certains tats ne permettent pas l exclusion ou la limitation des dommages indirects ou cons cutifs ni les limitations relatives la dur e des garanties implicites Par cons quent il se peut que les limitations ou les exclusions ci dessus ne s appliquent pas Cette garantie procure des droits juridiques pr cis l Acheteur Cependant il est possible de b n ficier d autres droits qui varient selon l tat SIMER 293 Wright St Delavan WI U S A 53115 T l phone 1 800 468 7867 1 800 546 7867 T l copieur 1 800 390 5351 Courriel info simerpumps com Site Web http www simerpumps com Especificaciones y Seguridad DESCRIPCION Esta Bomba Sumergible de Sumidero ha sido dise ada para sumideros dom sticos La unidad viene equipada con un cord n el ctrico de tipo puesta a tierra con tres puntas El motor monof sico de inducci n est lleno de aceite y viene cerrado herm ticamente para una operaci n m s fr a Los cojinetes de manguito en el
42. ver abajo o Pasador wer Y Flotador 7 1 4 ___ Tope de Varilla la varilla AVISO Consulte las instrucciones incluidas con el interruptor de repuesto Repuesto No FPS17 66 Para refacciones o asistencia llame a Simer Servicios al Cliente al 800 468 7867 800 546 7867 Refacciones 17 MODELO 2944RP 6131 1209 Ref Descripci n Cant 2944RP 1 Ensamblaje de cord n de corriente 1 PS117 54 TSU 2 Motor 1 oe 3 Voluta superior 1 PS1 31P 4 Tornillo cabeza de cono achatado Phillips 8 32x5 8 4 t 5 Impulsor 1 RP0000911A 6 Voluta inferior 1 PS1 30P 7 Tornillo cabeza grande de cono achatado 8 16x1 2 7 t 8 Adaptador de 1 1 4 NPT x 1 1 4 corrediza 1 Tt 9 Abrazadera del interruptor 1 t 10 Unidad del interruptor de flotador vertical incluye la Referencia No 9 1 FPS17 66 11 Adaptador de 1 1 4 NPT x 1 1 2 corrediza 1 t 12 Boquilla de manguera de 1 1 4 NPT x 1 1 4 1 t e Juego de manguera de 1 1 4 x 24 incluye la Referencia No 12 1 FP0012 6U P2 Si el motor est defectuoso Reemplace la bomba 1 Art culo de ferreter a est ndar se debe adquirir localmente e No se ilustra Para refacciones o asistencia llame a Simer Servicios al Cliente al 1 800 468 7867 800 546 7867 Soluci n de problemas GU A PARA LA RESOLUCI N DE PROBLEMAS 18 m nivel de agua est demasiado bajo Un fusible se ha quemad