Siemens Computer Hardware TM User's Manual

image

Contents

1. S _ n Idle time 1 Tidi 515 Idle time 2 Tid2 980 e The PROFIBUS bus parameters for WinCC are specified in the user defined profile But for the Ttr parame ter the values of the general purpose profile will be transferred to the user defined profile if the general purpose profile is selected beforehand In this case these values are almost identical to the above mentioned ones e Use the following formula to calculate the Ttr parameter and enter it Ttr I2 ttr 9000 number of active PROFIBUS TM devices Note The factor 9000 in the formula is only valid for a baud rate of 1 5 Mbits s e For the baud rate of 1 5 Mbits s the default value of the gap factor is 30 50 Entering a smaller value may be necessary in exceptional cases e All specified bus parameters are tuned to the baud rate of 1 5 Mbits s Any change optimization requires a deep knowledge of the PROFIBUS standard e The bus parameters for all TELEPERM components e g 05525 and PROGRAF AS on the PROFIBUS TM system bus must be selected accordingly Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 17 of 21 9 Important Notes 9 1 Permissible Installations Software products that are not mandatory for the operation of PCS7 must not be installed in servers clients or multi clients This includes MS Office for example This shall prevent that the installation of other software components such as DLLs
2. 2 2 2 Restrictions e Trends by Means of Measurement Points function of WinCC LTO This function will no longer be available from V5 0 onwards Creating the WinCC Tag Management The WinCC Tag Management variable under connections may solely be created via TELEPERM M Import blocks wizard provided e Order of Simultaneously Occurring Messages in Alarm Logging Simultaneously occurring messages of a function block alarm warning tolerance are given out in order of the message numbers WinCC system feature 2 3 PCS7 TM OCX NORA formerly WinCC TM OCX NORA 2 3 4 Modifications vs Version V2 01 In addition to the present image blocks in TELEPERM M NORA representation we deliver a set of renovated image blocks They have identical display with the present ones additionally they are sup plemented with the properties Modus display mode group loop Farbe color of bars and digital values For details see description TELEPERM NORA renoviert pdf The contractions G_ or K in the OCX names have been dropped Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 4 of 21 These blocks can be installed on demand by checking the component Standard OCX renoviert in the installation program 2 4 PCS7 TM OCX PCS7 formerly WinCC TM OCX PCS7 2 4 4 Modifications vs Version V2 01 None 3 General Information About the Installation Requirements The software products that are contained on this CD ar
3. they must be incorporated by the configuring engineer if this is required 9 14 Init Button in System Parameter of the TELEPERM M channel CS 725 This button may not pressed at runtime in any case 9 15 Start up on Non existing Function Blocks The coupling start up on function blocks that do not exist in the AS is extended for some minutes per block 9 16 Start up on CS275 Device Number 0 Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 19 of 21 Device number 0 is reserved on all CS 275 busses and therefore may not be used 9 17 TELEPERM Mi in Intranet or Internet Please refer to the following sites for current information about TELEPERM M especially FAQs Homepage extern http www ad siemens de teleperm index 00 shtml Homepage intern http intra1 nbgm siemens de extern spiegeln teleperm index 00 shtml 10 Appendix 10 1 Files and Search Paths The following files are copied when theTELEPERM M channel is installed LW ASiemens TM WerkzeugeW iesmich txt LW ASiemens TM Werkzeuge MRegini exe LW ASiemens TM WerkzeugeWincc ldb LW ASiemens TM Werkzeuge WM Info exe lt LW gt Siemens WinCC bin NrmTelpm nll lt LW gt Siemens WinCC bin TELEPERM M WNF Support dll lt LW gt Siemens WinCC bin TELEPERM M chn lt LW gt Siemens WinCC bin Telpmdeu Ing lt LW gt Siemens WinCC bin Telpmenu Ing lt LW gt Siemens WinCC bin Telpmfra Ing lt LW gt Siemens WinCC bin Ydata220 Dat lt LW gt Sie
4. 5 2 14 T Creatim anew PCS 7 TM Project herr En in 15 7 1 Creating a Project for Multi Client Operation on a Server essere 15 7 20 Creating a Multi Client Project in a Multi Client eese nennen een 16 8 Bus Parameters for PROFIBUS TM System Bus on ASx88 TM and WinCC sese 17 9 Important one Seo D teetteioed oem ee tete ien ico tt ERU eH 18 9 1 Permissible Installations 00er ne ae lnen 18 9 2 TimeintheB s System He een iiie e Res 18 9 3 Logical Connections 4 rete RE RE UI etai pin Uv RR lieto UE eee 18 94 CZIKS BIOCKS PEE 18 9 5 C SCHDIS REN dst ot I n eR Usu tiet netirtun icem EIGENE EHE 18 9 6 Quantity enit edo ete cie ee ee Oed D E GT DRE CNET 18 9 7 PROGRAE AST sedem on nes einen ee item e a mH 18 9 8 Manipulations in tbe AS eite e eiie ee thee iei RBB eb Oti Errant 18 9 9 S Strings in TML Blocks ht stk Sb 19 9 10 Structures of Field Blocks GA GB 19 OAL een Round amovit 19 9 12 Number of Variables Under a 19 9 13 Troubleshooting iere tei me Pe e pr ERR ies P o REPE Reprints 19 9 14 Init Button in System Parameter of TELEPERM M channel CS 725 sees 19 9 15 Start up on Non existing Function Blocks esessessesesseeeeeen
5. Tools sess 7 3 4 1 Installation of the N AT N PCI driver ssssseeeeneneenenenee nemen emen nennen enin ener enirn nennen 7 3 4 2 What to do after the Installation 2 7 3 5 Installation of the PCS7 TM OCX NORA formerly WinCC TM OCX 7 3 5 1 Procedure of the manual 1 esee nennen enne nennen neret nennen 8 3 5 2 Revision levels nia AIR MEOS 8 3 5 3 What to do after the installation lessesseseesesseeeeee eene enne enne nennen 8 3 6 Installation of the PCS7 TM OCX PCS7 formerly WinCC TM OCX PCS7 9 3 6 1 Procedure of the manual 1 enne 9 3 6 2 Revision levels ronda Nae Abies tdi Nee 9 3 6 3 What to do after the installation Peisenieks 9 3 6 4 Simultaneous Utilization of PCS7 TM OCX NORA and PCS7 TM OCX PCS 10 3 7 Necessary TM Licenses Authorization 11 3 7 1 Upgrade from WinCC TM V1 0x to PCS7 TM 2 0 11 4 Documientatiof uehementer anm e Nee aa eek et ee sat Se Anes 12 5 Version Interdependencies isses ne DR He peii ec ANG oa RG NS Se dawns 13 6 Conversion of a PCS 7 TM Project from WinCC 4 0 to 5 x 13 Transition from WinCC V5 0 to V5 0 SP2 PCS7
6. of 21 e Terminate WinCC and restart it afterwards Start DynWizEdit Read all four TELEPERM M wizards TELEPERM M Verbindung einrich ten wnf TELEPERM M Import ORPA wnf TELEPERM M Import Bausteine wnf and TELEPERM M Meldungen wnf from the Siemens WinCC BSTMapper directory and create a CWD file gt When activating the Split Screen Wizard from the current version V2 02 the current wiz ards are already included in the project e Implementing the changes in the group display routing requires the variable management and the ORPA definitions structures to be deleted and newly to be created All TELEPERM M messages must first be cleared e Toimplement the changes of the message generator you must first start it and clear all existing TELEPERM M messages Next you must start the message generator again and create default message texts e Area specific reporting Using this function requires messages from function blocks via status word to be allocated to an area in the sense of the Picture Tree Manager Manual allocation Each message concerned must be provided with an area name in the Area message block Allocation via EXCEL list and TM RangMeld To make this allocation more convenient and easier to reproduce it can be performed using the TM RangMeld program that is provided on the WinCC TM CD and an EXCEL list that must be created beforehand See the corresponding description on the CD Allocation via exporting im
7. setup Any existing installation will be removed during this process The Prototype images option can be used for copying these images into the corresponding WinCC folder from where they will be copied into the project when the Split Screen Wizard executes The authorization must be transferred to the same drive as the other PCS7 authorizations To do this please insert the authorization floppy disk into the drive and double click on the Authors exe or Authorsw exe program same procedure as for other PCS7 WinCC compo nents Of course this step is only necessary if an authorization has not yet been installed The image blocks in PCS7 similar representation are now ready for the configuration in the WinCC Graphics Designer Note Some image blocks in PCS7 similar representation need more parameters in the ORPA filter than the ones in TELEPERM M representation Instead of the ORPAFilter txt file that was copied into the lt LW gt Siemens WinCC BSTMapper directory during the installation of the TELEPERM M channel ORPAFilter from the TM7 directory of the CD shall therefore be used This directory also contains the prototype images 3 6 2 Revision levels ElementeTM7 ocx V3 00 00 Input ocx V3 00 00 TM7 x V3 00 00 3 6 3 What to do after the installation After the successful installation all optionally installed prototype images may be copied with the WinCC Split Screen Wizard into the current project Product Inform
8. 235H AS 388 AS 488 AS 215 AG 150U AG 155U AS 220S AS 220H See also Chapter 3 7 Necessary Licenses Startup features The AS systems are marked as failed during the entire duration of the startup phase Furthermore all AS systems must be operational on the bus at the startup time 3 4 1 Installation of the N AT N PCI driver If the N AT driver is required it can be installed via a separate installation procedure NAT NPCI Please execute the program Setup exe in the directory swWNAT_NPCI 342 What to do after the Installation After the successful installation all delivered TM configuration tools i e wizards should be imported with the WinCC Dynamic Wizard Editor This is not necessary if the Split Screen Wizard is executed recommendation herewith the current TM configuration tools are copied into the project and are available there 3 5 Installation of the PCS7 TM OCX NORA formerly WinCC TM OCX NORA Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 7 of 21 The image blocks in TELEPERM M NORA representation and the authorization DLLs that are re quired for proper operation are in the directory swWOCX TM on the CD The authorization is supplied on a separate floppy disk This package must be installed in all computers that shall be used for operator communication and visualization Single user system also ES Multi clients or Clients Server if it is operator station at the same
9. Notes must basically be used Observe this procedure To show this clearly we point out the following mandatory steps Open the project with WinCC V5 x e Editthe Split Screen Wizard With single user systems or multi client systems the area overview on the server now contains 16 areas instead of 12 previously With multi client systems one out of two area overviews can be selected on the multi client e Across all servers with a total of 16 areas e Server specific overview with 12 areas and an additional 6 server buttons Recommendation for the selection of the area overview in clients of multi client systems The first variant should be selected in a system of no more than a total of 16 areas The second variant should be preferred in systems of more than 16 areas e Edit the Alarm Logging Wizard e Convert the graphic images e Convert the global library e Convert the project library e Open tag logging and save to terminate Open the Picture Tree Manager and save to terminate it It can happen upon the migration of projects from WinCC version V4 0x to WinCC version 5 that an OCX in a graphic image is either not recognized unknown object or that the properties are no longer visible in the Graphics Designer The corresponding OCX must newly be placed in ei ther case Failure to do so will produce an error message when the Picture Tree Manager is saved Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 13
10. SIEMENS PCS7 TM WinCC TM V2 02 Product Information This product information is more binding than current statements in Manuals and in the on line help Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 1 of 21 Chapter Page 1 General Information DU Reti ideni ite isti 3 2 Whats NOW iced tee me mu c rb S Lu 3 2 1 CD content in pet eet DERE GORGE 3 2 1 1 TM SmartFools 5 tenete eiua E 3 2 2 TELEPERM M channel ieri tere iet ce aaa dee ana 3 2 2 1 Modifications vs Version 2 01 3 2 2 2 Restrictions u nenn ln ee e PEA des eda cee EI eee t I 4 2 3 PCS7 TM OCX NORA formerly WinCC TM OCX NORA essere nennen 4 2 3 1 Modifications vs Version V2 01 sse eene tenentes enne 4 24 PCS7 TM OCX PCS7 formerly WinCC TM OCX PCS7 5 2 4 1 Modifications vs Version 2 01 5 3 General Information About the Installation esses eee enne enne ener ente nnne enn enne 5 3 1 Operation system Windows NT 4 0 Upgrading to SP5 sess 2 3 2 Content of the CD cese s edi ertet ec Sap beret bre dere E e teks 3 3 3 Installation using the Common Installation Mask eese nenne 5 3 4 Installation of the TELEPERM M Channel DLL and
11. X dll V1 0 0 3 Image blocks OCX for the five standard function blocks TRAS TRB TRES TRM and TRR are pro vided for the operation with AS 215 Their utilization is subject to change 3 5 3 What to do after the installation After the successful installation all optionally installed prototype images may be copied with the WinCC Split Screen Wizard into the current project Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 8 of 21 3 6 Installation of the PCS7 TM OCX PCS7 formerly WinCC TM OCX PCS7 The image blocks in a PCS7 similar representation and the authorization DLL that is necessary for proper operation are located in the directory sv OCX_TM7 on the CD The authorization is supplied on a separate floppy disk This package must be installed in all computers that shall be used for operator communication and visualization Single user system also ES Multi clients or Clients Server if the server is operator station at the same time 3 6 1 Procedure of the manual installation There is an older version of WinCC TM OCXen PCS7 in your computer and the objects WinCC TM OCX PCS7 and VB5 DLL are contained in the Settings System con trol Software tab Uninstall these two objects To install the image blocks in PCS7 similar representation branch to the SW OCX TM7 di rectory and invoke Setup exe there The further install procedure will be prompted Also install the VB6 DLL in the same
12. ager Manual allocation Each message concerned must be provided with an area name in the Area message block Allocation via EXCEL list and TM RangMeld To make this allocation more convenient and easier to reproduce it can be performed using the TM RangMeld program that is provided on the WinCC TM CD and an EXCEL list that must be created beforehand See the corresponding description on the CD Prior to this step you should expediently create the topmost area level in the Picture Tree Man ager e f necessary the TELEPERM M message class must be included in the selection of the individual message windows e Next all further configuration steps are performed Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 15 of 21 Once the configuration has been completed a package for the operation from a multi client must be created under Serverdata In the project the package is created in the Package subdirectory of the directory that bears the name of the computer 7 2 Creating a Multi Client Project in a Multi Client e Create the project as a multi client system with WinCC PCS7 gt V5 0x e Edit the Split Screen Wizard Selection between two area overviews is possible in the multi client e Across all servers with a total of 16 areas e Server specific overview with 12 areas and an additional 6 server buttons Recommendation for the selection of the area overview in clients of multi client systems The first variant
13. ated under an AS connection 9 13 Troubleshooting Tips 2 License Problems at Runtime Frequently the TELEPERM M hotline is notified of license problems that are signalled during runtime after the TELEPERM M channel has been installed In all cases this is due to the fact that an authori zation was purchased for the operation with AS 23 while version AS 23 and AS 220 was specifi cally selected during the installation process The problem is eliminated when installation is repeated correctly Version and AS type of the TELEPERM M channel are stored in the registry code HKEY LOCAL MACHINE Software Siemens AGWinCC TM under Version or AS Typ respec tively This information can be retrieved via the program TM Info in the TM Werkzeuge directory 2 Missing Texts in Image Blocks Likewise customers frequently report that texts are not displayed in the image blocks during runtime after the WinCC TM OCX NORA has been installed This is due to the fact that contrary to the re quirement fixed in the description these image blocks were not configured via the property box Once the image blocks have been edited via this property box the texts are transferred and are displayed by the image blocks during runtime gt Message of the Teleperm M Class For various function blocks the TELEPERM M message generator creates messages of the TELEPERM M class Since this class is obviously not contained in the prefabricated WinCC message images
14. ation PCS7 TM V2 02 24 10 2001 Siemens AG 2001 9 of 21 3 6 4 Simultaneous Utilization of PCS7 TM OCX NORA and PCS7 TM OCX PCS7 Both image block types can be used simultaneously in a computer However the package of the im age blocks in TELEPERM M NORA representation must first be installed If one of the simultaneously installed packages shall be removed we strongly recommend to remove both packages and to reinstall the one that shall remain Simultaneous utilization of the prototype images of both image types is not possible because of identity of the objects names Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 10 of 21 3 7 Necessary TM Licenses Authorization Authorizations are installed in the lt LW gt AX NF ZZ directory Depending on the employed channel the following authorization must be stored there TELEPERM M channel DLL CS 275 L2 AS 23x AS 488 AS 215 AG 150U AG 155U only A7TMCS50 AS 220 only A7T2CS50 AS 220 and AS 23x AS488 AS 215 AG 150U AG 155U A7TACS50 This authorization must be installed in all computers that communicate with an AS If the installed channel and the authorization are not compatible with each other a box appears during runtime that states this incompatibility The License log file in the lt LW gt Siemens WinCC Diagnose directory tells you which license is required for the installed channel Image blocks PCS7 TM OCX The authorization A7TMFP50 is
15. e released under WinCC Version 5 0 SP2 HF7 or PCS7 Version 5 2 and Windows NT 4 0 SP5 The hardware requirements are listed in the associated documents Vertriebsfreigabe zu PCS7 TM V2 02 in TELEPERM M aktuell With transition to PCS7 V5 2 the C partition of the used computer must have a memory of at least 4 GByte Please observe the Chapter 5 Version Interdependencies in this document 3 1 Operation system Windows NT 4 0 Upgrading to SP5 Note The PCS 7 TM CD does not contain the operation system Windows NT 4 0 or any Service Packs SP Language variants of the SP must be used according to the selection in the base installation To install the NT SP5 load the corresponding Setup exe Overwrite older files when the system asks for file versions during the installation process Please observe the notes etc of the SP5 3 2 Content of the CD The software components for PCS 7 TM and the documents are supplied on CD ROM CD directory structure under the directory PCS7 Version 5 excerpt Dok Contains the product information and all the descriptions in pdf format see chapter 4 Siemens Contains the channel components in an uncompressed form 2 example projects as well as a part of a project and some Scripts and functions SW Contains the installation programs for channel and image blocks and additional products Winnt 400 Contains the old driver software for the N AT module 3 3 In
16. eene enne nennen 19 9 16 Start up on CS275 Device Number 0 eee essen senken 19 9 17 TELEPERM M in Intranet or 20 10 Appendix nte tice RR ORC utet e rien ipd der ed E E peres 20 10 0 Tilesand Search Patlis 2 oro retro ie ette o n t cute RUE 20 Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 2 of 21 1 General Information Scope of delivery This CD contains the following components for PCS7 OS versions V4 02 and V5 2 e TELEPERM M channel DLL Image blocks in TELEPERM M NORA representation PCS7 TM OCX NORA Image blocks in a representation similar PCS7 PCS7 TM OCX PCS7 Documentation and product information in pdf format see chapter 4 TELEPERM M tools such as establish connection ORPA import block import message gen erator e Configuring tools TM SmartTools including description Only with version 5 The scope of delivery does not contain e System software WinCC V5 0 SP2 HF7 or PCS7 OS V5 2 e Operating system Windows NT 4 0 including Service Packs 2 What s new 2 1 CD content in general Starting the program Setup exe in the root directory of the CD will identify the installed WinCC version and branch to the corresponding version s directory of the CD PCS7 Version 4 or PCS7 Version 5 For further information see chapter 3 3 If a valid version of WinCC cannot be identified t
17. emens TM_ocx TelepermMOCX dll lt LW gt Siemens TM_ocx Elemente ocx lt LW gt Siemens TM_ocx IXSimpleBar ocx lt LW gt Siemens TM_ocx TM_A ocx lt LW gt Siemens TM_ocx TM_B ocx lt LW gt Siemens TM_ocx Tm_C ocx LW ASiemens TM ocxXTM DZ ocx lt LW gt Siemens TM_ocx TM_EG ocx lt LW gt Siemens TM_ocx TM_EK ocx lt LW gt Siemens TM_ocx TM_EU ocx lt LW gt Siemens TM_ocx TM_F ocx lt LW gt Siemens TM_ocx TM_FN ocx lt LW gt Siemens TM_ocx TM_M ocx lt LW gt Siemens TM_ocx TM_MSB ocx lt LW gt Siemens TM_ocx TM_R ocx LW ASiemens TM ocxXTM RE ocx LW ASiemens TM ocx TM Rl ocx LW ASiemens TM ocxXTM RK ocx lt LW gt Siemens TM_ocx TM_RN ocx lt LW gt Siemens TM_ocx TM_S ocx lt LW gt Siemens TM_ocx TM_TVB ocx lt LW gt Siemens TM_ocx TM_V ocx lt LW gt Siemens TM_ocx TM_MKS ocx LW ASiemens TM ocxXTM Sym ocx lt LW gt Siemens TM_ocx Zusanz ocx lt LW gt Siemens TM_ocx TM_GLobal dll lt LW gt Siemens TM_ocx Language dll lt LW gt Siemens TM_ocx OCX_Texte407 dll lt LW gt Siemens TM_ocx OCX_Texte409 dll lt LW gt Siemens TM_ocx OCX_Texte40A dll lt LW gt Siemens TM_ocx OCX_Texte40C dll lt LW gt Siemens TM_ocx OCX_Texte40E dll lt LW gt Siemens TM_ocx OCX_Texte413 dll LW ASiemens TM ocxXOCX Texte41D dll lt LW gt Siemens TM_ocx TMOCX dil lt LW gt Siemens TM_ocx TMCOND dll lt LW gt Windowsdir TMOCX ini The following files are copied when the WinCC TM OCX PCS7 package i
18. ework see TELEPERM M aktuell 1998 01 1 A server may be charged with max 600 variables second 97 PROGRAF AS Utilization of PROGRAF AS data for the function ORPA import or block import as a function of the employed automation system AS 23x ASx88 As220 AS215 AG155U ORPA import X X 2 2 Block import X 1 21 1 1 Canbe generated with theTM_SmartTool genBST 2 On demand Please contact your Siemens sales partner 9 8 Manipulations in the AS Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 18 of 21 With manipulations in the AS it must be ensured that depending on the measure messages etc may be lost via status message frames and or MKS message frames Setting the AS in a defined state first is therefor expedient 9 9 S Strings in TML Blocks Only the first character of a parameter of the S type in a TML block can be read 9 10 Structures of Field Blocks GA GB etc Only one structure definition is possible for each field type All configured fields in the AS must show at least this length The export of PROGRAF AS merely creates the first element Any other element must be added manually The Oth element must also be created manually if it shall be read A length between 1 and 256 is possible 9 11 Fonts Large fonts must not be selected in the screen properties 9 12 Number of Variables Under a Connection A maximum of 64k variables may be cre
19. has a detrimental influence on the system behavior 9 2 Time in the Bus System Time synchronization is mandatory in the bus system Consistent message processing is not possible otherwise A PCS7 TM OS should be time master the time of the other PCs should be synchronized with the PCS7 tool DCS77 client 9 3 Logical Connections Creating logical connections with the same CS275 address is not permitted The name of a logical connection must not contain any special character including This means that AS 103 is not per mitted 9 4 ZKS Blocks The access to ZKS blocks has not been implemented 9 5 C Scripts e General We expressively want to point out again here that the general conventions of the pro gramming language C must be observed when scripts are employed Failure to do so may cause unpredictable reactions that can strongly affect proper operator communication and visualization e When connecting a graphical object with a script only the value of the object is transferred This value will be signed valid independent of the state of the value e When dynamising the property tagname of an OCX it should be taken care that this it not car ried out cyclically 9 6 Quantity Framework When project images are configured in WinCC TM the capacity utilization of the bus system and of the subordinate automation systems must be taken into consideration in addition to the specifications of the permissible mixed quantity fram
20. he program Setup exe will be finished after a message box has been given out Under the directory PCS7 Version 5 you find in addition to the current version of the TELEPERM M channel V2 02 also the older version V2 01 under the corresponding sub directory 2 1 4 SmartTools With Version 5 so called TM SmartTools are delivered which support the configuration These pro grams are delivered free of charge and without commitment They may be copied to any directory of the hard disk preferably XSiemens TM Werkzeuge and initialised from there A short description of the tools is delivered under the corresponding directory of the CD 2 2 TELEPERM M channel It is mandatory to install the TELEPERM M channel after the installation of the components for PCS7 or WinCC If WinCC is installed later the TELEPERM M channel has to been reinstalled again 2 2 4 Modifications vs Version V2 01 The following problems have been eliminated e Acceleration of the Message Generator Because of using a new function within WinCC the generating procedure could be accelerated The following new functions have been implemented With the current version V5 0 SP2 HF7 WinCC delivers a new function concerning redundancy e Switchover to the Master Server after CS 275 Coupling Start up When a server which is the master server for one or more multi clients is activated these multi clients switch over to this master server not before the coupling start up on t
21. he subsidiary AS is Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 3 of 21 terminated Switchover of the Servers after CS 275 Coupling Fault When at least one connection to a subsidiary AS fails the multi clients switch over to the redun dant server Attention An intentional switch off of a connection AS causes the same effect To activate these functions it is necessary to make an entry in the registry of the servers This entry can be made by double clicking on the file Fault ein reg Double clicking on the file Fault aus reg cancels this function Both files are stored in the CD directory lt gt PCS7_Version_5 Redundancy e Channel Diagnosis Hence the TELEPERM M Channel DLL uses the WinCC Channel Diagnosis It is initiated via Simatic WinCC Tools Channel Diagnosis You should select the following basic configuration WinCC Channel Diagnosis Channels Connections Configuration Always on top TELEPERM M Output Filename TELEPERM_M Flags Fatal Error Error Warning v Information hot dened Success LOG LIFEBEAT Iv Check User Flags LOG THREADS USELESs bc hot defined TraceFile natdefimed r max Files r r hot defined max Size Overwrite 7 User Flags LOG STATUS LOG BUSTIME Enable LOG INDICES LOG READ LOG WRITE TUS ieee z LOG DEBUG LOG MESSAGES J Snot defined Set Reset Se
22. mens WinCC BSTMapper BSTMapper enu TELEPERM M Import Bausteine wnf lt LW gt Siemens WinCC BSTMapper BSTMapper enu TELEPERM M Import ORPA wnf lt LW gt Siemens WinCC BSTMapper BSTMapper enu TELEPERM M Meldungen wnf lt LW gt Siemens WinCC BSTMapper BSTMapper enu TELEPERM M PseudoAS wnf lt LW gt Siemens WinCC BSTMapper BSTMapper enu TELEPERM M Verbindung einrichten wnf lt LW gt Siemens WinCC BSTMapper BSTMapper enu TELEPERM M WNF Support h lt LW gt Siemens WinCC BSTMapper BS TMapper fra BSTFilter txt lt LW gt Siemens WinCC BSTMapper BST Mapper fra Logotm bmp lt LW gt Siemens WinCC BSTMapper BS TMapper fra ORPAFilter txt lt LW gt Siemens WinCC BSTMapper BST Mapper fra TELEPERM M Import Bausteine wnf lt LW gt Siemens WinCC BSTMapper BST Mapper fra TELEPERM M Import ORPA wnf lt LW gt Siemens WinCC BSTMapper BSTMapper fra TELEPERM M Meldungen wnf lt LW gt Siemens WinCC BSTMapper BST Mapper fra TELEPERM M PseudoAS wnf lt LW gt Siemens WinCC BSTMapper BSTMapper fra TELEPERM M Verbindung einrichten wnf Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 20 of 21 lt LW gt Siemens WinCC BSTMapper BST Mapper fra TELEPERM M WNF Support h The following files are copied when the WinCC TM OCX NORA package is installed lt LW gt Siemens WinCC bin ccGraphics WinCCDataServer dll lt LW gt Siemens WinCC bin ccGraphics ccUserAdmin dll lt LW gt Siemens WinCC bin ccGraphics CCOperationMessage dll lt LW gt Si
23. mens WinCC bin Ydata230 Dat lt LW gt Siemens WinCC bin TM_RangMeld exe lt LW gt Siemens WinCC BSTMapper BSTFilter txt lt LW gt Siemens WinCC BSTMapper Logotm bmp lt LW gt Siemens WinCC BSTMapper ORPAFilter txt lt LW gt Siemens WinCC BSTMapper TELEPERM M Import Bausteine wnf lt LW gt Siemens WinCC BSTMapper TELEPERM M Import ORPA wnf lt LW gt Siemens WinCC BSTMapper TELEPERM M Meldungen wnf lt LW gt Siemens WinCC BSTMapper TELEPERM M PseudoAS wnf lt LW gt Siemens WinCC BSTMapper TELEPERM M Verbindung einrichten wnf lt LW gt Siemens WinCC BSTMapper TELEPERM M WNF Support h lt LW gt Siemens WinCC BSTMapper BSTMapper deu BSTFilter txt lt LW gt Siemens WinCC BSTMapper BSTMapper deu Logotm bmp lt LW gt Siemens WinCC BSTMapper BSTMapper deu ORPAFilter txt lt LW gt Siemens WinCC BSTMapper BSTMapper deu TELEPERM M Import Bausteine wnf lt LW gt Siemens WinCC BSTMapper BSTMapper deu TELEPERM M Import ORPA wnf lt LW gt Siemens WinCC BSTMapper BST Mapper deu TELEPERM M Meldungen wnf lt LW gt Siemens WinCC BSTMapper BSTMapper deu TELEPERM M PseudoAS wnf lt LW gt Siemens WinCC BSTMapper BSTMapper deu TELEPERM Verbindung einrichten wnf lt LW gt Siemens WinCC BS TMapper BSTMapper deu TELEPERM M WNF Support h lt LW gt Siemens WinCC BSTMapper BSTMapper deu BSTFilter txt lt LW gt Siemens WinCC BSTMapper BSTMapper enu Logotm bmp lt LW gt Siemens WinCC BSTMapper BS TMapper enu ORPAFilter txt lt LW gt Sie
24. n symbol representation WinCC TM OCX AS215 Description of the image blocks for AS 215 MKS Description of the single bit acknowledgement of the MKS block TELEPERM NORA renoviert Description of the integrated image blocks in TELEPERM M NORA representation The Acrobat Reader is provided ar40deu exe for reading the pdf files Acrobat Reader Copyright 1987 1999 Adobe Systems Incorporated All Rights Reserved Adobe the Adobe Logo Acrobat and the Acrobat Logo are trademarks of Adobe Systems Incorpo rated TM_SmartTools The description of the TM_SmartTools is stored in the corresponding directory as a file in Word pad format Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 12 of 21 5 Version Interdependencies Program Released Versions WinCC V4 02 SP3 V5 0 SP1 HF5 V5 0 SP2 V5 0 SP2 HF7 1 HF2_K5 2 58 2 PCS7 V4 V5 0 SP1 HF2 V5 1 V5 2 HF5 HF2 K5 2 58 2 PCS7 TM OS V1 05 V2 00 SP1 Windows NT 4 0 SP5 4 0 SP5 6 Conversion of a PCS 7 TM Project from WinCC 4 0x to 5 x This conversion requires special knowledge and should be realized by appropriate qualified personal only Following are the steps to be considered in short This explanation is valid for the language selection German A project that was created under WinCC 4 02 or an earlier version must first be converted for PCS7 WinCC 5 x The procedure that is described in the WinCC product information Release
25. ns a menu item Upgrading guideline This guideline can support you during upgrading 3 Select the Authorization management tab Select the menu item Upgrading from the Authorization menu 4 Select the upgrade program from the dialog that is opened subsequently You will then be prompted to insert the authorization floppy disk of the old authorization V1 0x Please follow the instructions on the screen and insert the Authorization floppy disk upgrade when you are prompted to do so 5 Upgrading will be terminated when the new authorization V2 0 is activated on the Authorization floppy disk upgrade 6 The new authorization can now be transferred to your computer during the setup or using AuthorsW Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 11 of 21 4 Documentation Revised descriptions in pdf format are supplied in the dok directory on the delivery CD Their contents replace the printed descriptions PCS 7 TM Name of the document WinCC TM Description of the TELEPERM M channel and the tools order no C79000 T8000 C740 xx PCS 7 TM OCX NORA Name of the document WinCC TM OCX NORA Description of the image blocks in TELEPERM M NORA representation order no C79000 T8000 C741 xx PCS 7 TM OCX PCS7 Name of the document WinCC TM OCX PCS7 Description of the image blocks in PCS7 similar representation order no C79000 T8000 C741 xx WinCC TM OCX Symbole Description of the image blocks i
26. porting with the Alarm Logging Editor Another possibility is the export of the relevant messages set the selection accordingly in Alarm Logging into a file editing the messages such that an area name is entered in the Block 2 area column and removing the associated TextlD TextID 2 in the same line Next reimport the file in Alarm Logging e The converted project must be a multi user system if it shall be used as a server in multi client operation With an empty test point list that was filled by the tag editor up to V4 02 there may be an error message when the package is created that is required for multi client operation This error message can be ignored in most cases However you should ensure that the package has been created in the Package subdirectory of the directory that bears the name of the computer Transition from WinCC V5 0 to V5 0 SP2 PCS7 V5 2 Special measures are not required for this transition The Es WinCC wizards Split Screen Wizard and Alarm Logging Wizard should always be activated This is to guarantee that modifications and en hancements will be transferred into the project Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 14 of 21 7 Creating a new PCS 7 TM project This explanation is valid for the language selection German Please observe the WinCC PCS 7 product information ReleaseNotes 7 1 Creating a Project for Multi Client Operation on a Server e Create the p
27. roject as a multi user project with WinCC PCS7 gt V5 0 It must be noted here that the server name and the project name in the multi client are both dis played according to the selection of the area overviews The names of the two components should therefore not be excessively long e Edit the Split Screen Wizard e Edit the Alarm Logging Wizard e Insert new driver for the TELEPERM M channel in the variable management Start DynWizEdit and read all 4 TELEPERM M wizards TELEPERM M Verbindung einrich ten wnf TELEPERM M Import ORPA wnf TELEPERM M Import Bausteine wnf and TELEPERM M Meldungen wnf from the Siemens WinCC BSTMapper directory and create CWD file Note When activating the Split Screen Wizard from the current version V2 02 the current wizards are already included in the project e Execute wizard TELEPERM M Verbindung einrichten and define the desired connections e Execute Import TELEPERM M ORPAs once or twice user or TML blocks 2 Please do not forget that importing so called field blocks GA GB etc always only 1 element is generated additional elements have to be defined manually before executing the import of TELEPERM M blocks e Execute Import TELEPERM M blocks e Execute TELEPERM M messages and create default message texts e Area specific reporting Using this function requires messages from function blocks via status word to be allocated to an area in the sense of the Picture Tree Man
28. s installed lt LW gt Siemens TM_ocx TM_GLobal dll lt LW gt Siemens TM_ocx TelepermMOCX dll lt LW gt Siemens TM_ocx TMOCX dil lt LW gt Siemens TM7_ocx ElementeTM7 ocx lt LW gt Siemens TM7_ocx Input ocx lt LW gt Siemens TM7_ocx TM7_A ocx lt LW gt Siemens TM7_ocx TM7_A_MotVen ocx lt LW gt Siemens TM7_ocx TM7_B ocx lt LW gt Siemens TM7_ocx TM7_C ocx lt LW gt Siemens TM7_ocx TM7_F ocx lt LW gt Siemens TM7_ocx TM7_FN ocx lt LW gt Siemens TM7_ocx TM7_M ocx lt LW gt Siemens TM7_ocx TM7_R ocx lt LW gt Siemens TM7_ocx TM7_RN ocx lt LW gt Siemens TM7_ocx TM7_V ocx lt LW gt Siemens TM7_ocx PCX_Texte407 dll lt LW gt Siemens TM7_ocx PCX_Texte409 dll lt LW gt Siemens TM7_ocx PLanguage dll lt LW gt Windowsdir TMOCX ini Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 21 of 21
29. should be selected in a system of no more than a total of 16 areas The second variant should be preferred in systems of more than 16 areas e Edit the Alarm Logging Wizard e Import the server packages e Create the operator input privileges in the User Administrator e Define the standard server for alarm logging This definition must be made to store the operator communication messages of a multi client in a server the selected default server e The connection to the servers is established under Serverdata by loading the packages Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 16 of 21 8 Bus Parameters for PROFIBUS TM System Bus on ASx88 TM and WinCC Parameter DOS CONF DAT L2AMPRO INI Configura Value description in AS488 and in tion dialog in Bridge ASx88 Windows NT for WinCC Highest station address 12 hsa 12 hsa Highest Sta 7 126 tion Address Local device address l2 ts 12 ts Local Station 1 99 Address Baud rates index 12 baud rate 12 baud rate Transmission 1 5 Mbits s Rate Slot time T2 tsi 12 tsl Tslot 3000 Quiet time 12 tqui Tqui 0 Setup time 12 tset 12 tset Tset 240 Minimum station delay 12 max tsdr 12 max tsdr Max Tsdr 980 time Maximum station delay 12 min tsdr 12 min tsdr Min Tsdr 150 time Token rotation time 12 ttr 42 Er TEE min 90000 GAP factor 12_g Gap factor 30 Retry Limit 12 12 retry ctr
30. so ES Client server system in all servers in the clients merely the TELEPERM M chn channel and all files of the Telpm Ing type Multi client system in all servers in the multi clients merely the TELEPERM M chn channel and all files of the Telpm Ing type The authorisation is supplied on a separate floppy disk Manual installation To install the TELEPERM M channel DLL and tools please branch to the SW Kanal directory and invoke Setup exe there From now on the installation procedure will be prompted The default setting of lt LW3 is the installation drive of WinCC This setting must not be changed If not already done explicitly at the beginning any existing installation will be removed during this proc ess If it does not yet exist the authorization must be transferred to the PCS 7 installation drive To do this please insert the authorization floppy disk into the drive and double click on the Authors exe or Authorsw exe program same procedure as for other PCS 7 components The installation is thus performed Further information can be found in the LW Siemens TM Werkzeuge Wiesmich txt file or in the documentation The files Ydata220 dat and Ydata230 dat that are included in the delivery contain the data that is relevant for the W startup and must not be modified Depending on the installed authorization this software version permits communication with the following automation systems AS 230 AS 235 AS
31. stallation using the Common Installation Mask This CD is equipped with an Autorun facility that automatically starts the installation mask when the CD is inserted provided that the computer has been set up for this feature If this selection has not been made in your computer the installation mask can also be initiated by double clicking on the setup exe in the CD s root directory Using the common installation mask it is sufficient to select all components to be installed When WinCC TM is selected the check is automatically set for the NAT NPCI driver software The check can be removed if this driver software shall not be installed The language selection in the in Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 5 of 21 stallation mask solely concerns the comments the language of the installation proper must be speci fied separately Any old installation of the components that are to be installed will be removed at the beginning Each installation procedure may be started manually and separately using the file setup exe in the corresponding sub directory It should be taken into consideration that during all installation procedures WinCC must be terminated Product Information PCS7 TM V2 02 24 10 2001 Siemens AG 2001 6 of 21 3 4 Installation of the TELEPERM M Channel DLL and Tools The TELEPERM M channel DLL and tools package must be installed in the following WinCC comput ers Single user system al
32. time 3 5 1 Procedure of the manual installation There is an older version of WinCC TM OCXs NORA in your computer and the objects WinCC TM OCX NORA and VB5 DLL are contained in the Settings System con trol Software tab Uninstall these two objects To install the image blocks in TELEPERM M NORA representation branch to the SW OCX TM directory and invoke Setup exe there The rest of the installation procedure will be prompted Also install the VB6 DLL in the same setup If not already done explicitly at the beginning any existing installation will be removed during this process The Prototype images option can be used for copying these images into the corresponding WinCC folder from where they will be copied into the project when the Split Screen Wizard executed The authorization must be transferred to the same drive as the other PCS7 authorizations To do this please insert the authorization floppy disk into the drive and double click on the Authors exe or Authorsw exe program same procedure as for other PCS7 WinCC compo nents Of course this step is only necessary if an authorization has not yet been installed The image blocks in TELEPERM M NORA representation are now ready for the configuration in the WinCC Graphics Designer 3 5 2 Revision levels Elemente ocx V3 00 00 TM x ocx V3 00 00 x stands for the different block types TM MKS ocx V3 00 00 TM Sym V3 00 00 TM AS215 V3 00 00 TelepermMOC
33. uniformly required for all image blocks It must be installed on each PC where operator input and visualization is required 3 7 1 Upgrade from WinCC TM V1 0x to PCS7 TM V2 0x For this upgrade we offer the Upgrade package V2 0 Changing from PCS7 TM V2 00 to V2 01 or V2 01 to V2 02 the TM licences are not affected Important note Upon the migration from version V1 0x V1 05 to version V2 0 you will irrevocably lose the authorization for the previous version We recommend to perform the migration of the authorization prior to the installation of PCS7 TM The migration requires the following preconditions to be fulfilled e You possess a single license or a copy license for WinCC TM V1 0x on an authorization floppy disk or in your computer e You have purchased an upgrade license to PCS7 TM V2 0 referred to as authorization upgrade in the text below To upgrade the software from version V1 0x use the following procedure 1 The old authorization must be on the associated old authorization floppy disk If necessary you must first transfer this authorization from your computer onto the old authorization floppy disk 2 Insert the authorization floppy disk upgrade and invoke the AuthorsW program via the start bar under Simatic AuthorsW If AuthorsW has not been installed in your computer you must carry out the installa tion from the CD Setup exe in the Authors Disk 1 directory The Extras menu contai