Home

Serengeti Video Games SmartSync User's Manual

image

Contents

1. 3780Link for Windows SmartSync DCP Version Installation Guide Table of Contents Technical Suppott capirti ora E REALI 2 Hardware Installation sisisi neissen na ia paia dennes 3 Installation of ISA Bus SmartSync DCP Adapter 3 Hardware Port Addresses i 4 Memory Mapped Addresses eric 4 Software Installation e 5 Software Removal i icarraa ica Panicale 6 Running 3780Link GUI for the First Time ii 7 The 3780Link GUI Window ee eeceseceeceseceecaeecaeesaecaaecaeeeaeeeeeenaeees 7 The 3780Link GUT Toolbat yss eirese alata 8 Receiving Files Using 3780Link GUI ii 8 Running 3780Link SO for Attended Communications Sessions 9 The 3780Lmnk SO Window icai aaa vote ianen eni ee 9 The 3780Link SO Toolbar ii 10 General Features of 3780Link for Windows re ere ersennee 10 Command Line Switches eesecesecssecseecsecseecseecaeeeneeeeeee 10 Running 3780Link SO as an Icon or as a Window 10 Drag and Dop ra ee ice 11 MESS BOX EXE Message Box Display Program eee eee eens 12 TXLAT EXE Trace Translation Program i 13 AMXBSC EXE SmartSync DCP Download File 13 DCPLOAD SmartSync DCP Download Utility n 13 DCPPEEK SmartSync DCP BSC Pro
2. 37c 0x3bc 0x3fc Factory setting IMPORTANT Make note of the I O port you configure on your board since this information is required when installing 3780Link software Memory Mapped Addresses Each SmartSync DCP contains memory that is shared with your Windows system This shared memory is located between 640KB and 1MB in 16KB segments You choose the memory segment during the 3780Link installation there is not a hardware switch or jumper associated with this memory location Since VGA display adapters usually use selected memory between OxA0000 and OxCFFFF most Windows systems will have only the memory between 0xD0000 and OxEFFFF available It is possible that another adapter in your system may also require all or part of one of these segments you must resolve this conflict so each adapter has its own segment SmartSync DCP Installation Guide Software Installation Follow the steps below to install 3780Link for Windows e When installing to a Windows NT system you must have Administrator privileges to install 3780Link e Insert the first 3780Link diskette into a diskette drive e Click Add Remove Programs from the Control Panel and follow the instructions on the screen e Setup displays a welcome dialog and then displays the License Agreement Read this agreement carefully before continuing e Setup asks you for your Name Company Name and Serial Number Enter this information and click Next e Setup allows y
3. Link Client Application Program For those of you who wish to incorporate 3780 emulation into your own applications 3780Link SO may be used as a server application In fact the 3780Link GUI program uses 3780Link SO in this manner Two example programs a fully functional one written in C and C and a very simple one written using Microsoft FoxPro are included with 3780Link The FoxPro program client prg is very simple and will not be discussed here The C and C client sample named client was written using Microsoft Visual C and the Microsoft Foundation Classes and it utilizes the Dynamic Data Exchange Management Library DDEML The client program runs properly when 3780Link SO is executing the pipe s script file Studying the source code for this example program provides guidance in how to write your client application The client program provided gives a degree of direct manual control when used in conjunction with 3780Link SO and the pipe s script file The following paragraphs describe the use of the client program The client program automatically loads 3780Link SO if it s not already loaded using a command line of w3780so spipe s You ll see the following 3780Link SO window appear first on your screen followed by the client program window La TE S Z Aa 2 LL RIGHTS RESERVED D1 Line 1 Create the pipe D1 Line 2 PIPE D1 Line 3 loop D1 Line 4 Wait for a
4. Windows S Silent mode The s switch prevents Deptrace from echoing debug messages to the screen To lessen the impact on other processes when running Deptrace use silent mode Silent mode may also be entered by unchecking the Echo to Screen menu item under the Options menu KILLBSC Kill BSC Protocol Task Program This program is used to terminate BSC processes running in the SmartSync DCP You should not need to use Killbse during normal operation However if 3780Link terminates abnormally you may have to run Killbsc to set the corresponding BSC process to the Not Running state before running it again The optional command line switches for Killbsc are described below f Forced kill The f switch may be used to force the termination of a BSC process when it is not Running in IDLE State b board Board number 1 6 The b switch specifies which SmartSync DCP associated with the BSC process is to be killed You must indicate the board number through 6 as appropriate The board number corresponds to the order in which they were configured If omitted the default is board 1 p port Port number 1 8 The p switch specifies the port associated with the BSC process that is to be killed If omitted the default is port 1 S Silent mode The s switch enables the silent mode that suppresses all output to the terminal with the exception of error messages SmartSync DCP Installation Guide 3780
5. a large file and the time out is too short the client program will not be able to receive the results of the SEND command from 3780Link SO You may set the time out to zero to prevent the client program from timing out Some important things to consider when creating a client application of any type are e The client program must set itself up as a DDE client for writing script commands to 3780Link SO using DDE Poke transactions The client program must set itself up as a DDE server for receiving result codes back from 3780Link SO using DDE Poke transactions The client program must have a DDE callback function and must process the appropriate messages from the operating system e In order for 3780Link SO to act as a server it must be running the pipe s script file that endlessly waits for script commands to be sent to it and executed 21 3780Link for Windows Notes 22 SmartSync DCP Installation Guide Notes 23 3780Link for Windows Notes 24
6. able PCI slot and skip ahead to the Software Installation section Installation of ISA Bus SmartSync DCP Adapter Refer to the DCP 286i INSTALLATION AND DIAGNOSTIC MANUAL or the DCP 386i e INSTALLATION GUIDE for hardware configuration and installation instructions It is a good idea to verify that all jumpers and switches on the board are set to the factory defaults prior to installation 3780Link for Windows When used with 3780Link the SmartSync DCP does not require the use of an interrupt IRQ in your computer Before installing the SmartSync DCP board be sure that the board is configured to NO INTERRUPT mode Note The diagnostic program provided with the DCP 286i and DCP 386i hardware requires that the IRQ jumper be set If you wish to run this diagnostic program you will have to set the IRQ jumper to a valid IRQ Hardware Port Addresses When installing a SmartSync DCP board choose an address that does not conflict with other hardware installed on your system Windows NT is able to detect a hardware port address conflict and will not allow the device driver to start if a conflict exists The I O address is set with the I O Address Switch block on your SmartSync DCP see Figure 2 1 in either the DCP 286i INSTALLATION AND DIAGNOSTIC MANUAL or the DCP 386i e INSTALLATION GUIDE The following hardware port addresses may be configured 0x03c 0x07c OxObc OxOfc 0x13c 0x17c Oxlbc Ox1fc 0x23c 0x27c 0x2bc 0x2fc 0x33c 0x
7. arily for trouble shooting purposes but can be run at any time to check the status of BSC processes The following is an example of output from Deppeek after running Depload with a single 4 port SmartSync DCP SmartSync DCP BSC Process Status Utility Mi E3 File Exit Help Board 1 BSC Emulation Downloaded BSC Interrupt Clock Running BSC Task Monitor Running BSC Process 1 Not Running BSC Process 2 Not Running BSC Process 3 Not Running BSC Process 4 Not Running Ports Available a Memory Installed 1024K Board Address 8100 Window Address E0910000 SmartSync DCP Installation Guide The BSC Task Monitor and Interrupt Clock should always be Running during normal operation The BSC Processes can have the following states Not Running Running in IDLE State Running in XMT State Running in RCV State and Not Running in IDLE State this is an error state If the BSC Task Monitor or Interrupt Clock is in the Not Running state you must run Depload to reinitialize the SmartSync DCP board This is also true if one the BSC Processes is hung in one of the Running states i e Killbsc is unable to return it to the Not Running state DCPDUMP SmartSync DCP Dump Utility This program is used to access the onboard memory and registers of SmartSync DCP This utility is strictly for diagnostic purposes and should only be used under t
8. cess Status Utility 14 DCPDUMP SmartSync DCP Dump Utility 00 eee cere eeecnees 15 DCPDEBUG SmartSync DCP Debug Utility eeeeeeeee 15 DCPTRACE SmartSync DCP Trace Dump Utility eee 17 KILLBSC Kill BSC Protocol Task Program eeeeeeeseeeseeseeees 18 3780Link Client Application Program i 19 3780Link for Windows Technical Support Serengeti Systems provides technical support for as long as you use 3780Link at no additional cost to you Support is available via the Internet from our web site or via e mail or by telephone e Access to Serengeti Technical Support is available from within the 3780Link GUI by way of your web browser or e mail assuming either or both of these are installed on the same PC as 3780Link Open the Help menu click Technical Support and follow the links to the Serengeti Web Page Technical Support or to access our support staff via e mail e Visit the Serengeti Web Page http www serengeti com directly and click on Technical Support to access our online technical database You ll find answers to many of the most commonly asked questions at your fingertips e For fast response to your technical support issue sum up your question or problem in writing and submit this via e mail to Support Serengeti com We ll respond to you by e mail or a telephone call if appropriate as quickly as we can e Ifyou cannot find t
9. cript File Alt R Em Exit 3780Link Ctrl Q View Reset Statistics 2 Help F1 Mira e General Features of 3780Link for Windows Command Line Switches Command line switches are passed to 3780Link GUI or 3780Link SO by adding the switch to the Target field in the Shortcut Properties window See the 3780Link User s Guide for more information on command line switches Running 3780Link SO as an Icon or as a Window When 3780Link SO is running as an icon the link state of the connection is included in the program title The five link states are Disconnected Line is disconnected Line Idle Line is connected no data is currently being sent or received Reader Active Data is being transmitted Printer Active Data is being received to the printer device SmartSync DCP Installation Guide Punch Active Data is being received to the punch device When 3780Link SO is not iconized these states are shown at the bottom of the window When running as an icon 3780Link SO terminates without any user intervention when script execution is complete If you wish to review the 3780Link SO session use the Notepad to look at the 3780link log file or whatever log file name you may have specified If 3780Link SO is running as a window the window remains as an active application when script execution is complete This allows you to scroll back and view the output from the 3780Link SO session or to restart the s
10. ession Drag and Drop Drag and drop may be used to run script files to call other script files to chain to other script files and to send files No file name extension verification is performed In other words 3780Link SO attempts to run any file that is dragged to it Script files conventionally are given a s extension but you are free to use any extension you wish It is up to you to drag and drop an appropriate script file when using Windows Explorer There are several ways to utilize drag and drop From Windows Explorer drag a script file and drop it onto the w3780so exe file Windows NT asks you if you want to start 3780Link SO with the file you dragged as the initial file If you answer yes 3780Link SO attempts to run the dropped file as a script file Or e Any time 3780Link SO is active and not running a script you may drop a script file on it from Windows Explorer OT 3780Link for Windows Drag and drop may also be implemented by using the d n switch on the SEND CALL and CHAIN script commands The SEND command waits for a dropped file to send and the CALL and CHAIN commands wait for a dropped script file to execute Use the d switch in place of a file name with the SEND CALL and CHAIN commands See the 3780Link User s Guide for more information on script commands If the optional n is omitted a default value of 0 is assumed causing 3780Link to wait indefinitely for a dro
11. he answers you re searching for online or you do not have e mail access you may call us at 512 345 2211 and ask for technical support during our normal business hours of 9AM to 5PM Central Time Monday through Friday SmartSync DCP Installation Guide 3780Link for Windows 3780Link operates under Microsoft Windows 95 Windows 98 or Windows NT Workstation or Server This installation guide applies only to the multi port version of 3780Link that uses the SmartSync DCP series of synchronous adapters This guide is designed to step you through the installation process and to describe the key components of 3780Link You may also wish to refer to the readme lst file for more information There are two executable versions of 3780Link One version referred to as the 3780Link GUI is intended for you to use interactively for direct control over a communications session The second version referred to as 3780Link Script Only or 3780Link SO for short is intended for unattended communication sessions controlled by script files s or by a separate program that you create More detailed information on both versions is presented later in this guide and may be found in the 3780Link User s Guide Hardware Installation This section applies only to the ISA bus SmartSync DCP adapter The PCI bus SmartSync DCP adapter is Plug n Play PnP so if you are installing a PCI bus adapter for use with 3780Link then simply insert it into any avail
12. he direction of Serengeti Technical Support DCPDEBUG SmartSync DCP Debug Utility This program is used to access debug messages generated by SmartSync DCP BSC processes This utility is used strictly for diagnostic purposes and should only be used under the direction of Serengeti Technical Support The debug messages obtained by Dcpdebug are automatically written to both the screen and a file For best results Depdebug should be run minimized so as not to affect transmission throughput when running 3780Link If you ve configured one SmartSync DCP the default file name is debug x where x is the port number If you ve configured more than one board the default file name is debug xy where x is the port number and y is the board number By default the output file is reset when it reaches 100 000 bytes This enables Dcpdebug to run continuously without overflowing disk storage The optional command line switches for Depdebug are described below 3780Link for Windows b board Board number 1 6 The b switch specifies which SmartSync DCP associated with the BSC process is to be killed You must indicate the board number through 6 as appropriate The board number corresponds to the order in which they were configured If omitted the default is board 1 p port Port number 1 8 The p switch specifies the port associated with the BSC process that is to be killed If omitted the default is port 1 m size Maximum
13. ou to change the default installation directory and Program Folder for 3780Link Typically the default directory of Program Files 3780Link and Program Folder of 3780Link are acceptable e The following dialog allows you to select the number of DCP boards the total number of ports and whether the boards are PCI or ISA bus adapters Hardware Configuration x The hardware in your system must be configured in order to work properly with BSCLIB for Windows with SmartSync DCP Select the number of DCP boards and BSC ports in your system and the type of bus used by the hardware adapter s DCP Boards BSC Ports Bus Type mm cs C Pcl gi Back Cancel La C3 Cu C5 Cs 3780Link for Windows If the DCP adapter s in your machine use the ISA bus the following dialog will allow you to set the I O port address and the dual ported memory address for each adapter installed Hardware Settings x Board 1 Select the 1 0 port addres hared memory window for this board See the SCB no Intaten Guide for more information on selecting thes Port Address Memory Mapped Address Ox33c ER 0xd0000 v e Ifyou are installing under Windows 95 98 you must reboot the machine before running 3780Link for the first time e You must run Depload to initialize the DCP hardware before running 3780Link See the following descriptions of the amxbsc exe file and the Depload u
14. our own using the Notepad available via a button within 3780Link SO or any text editor 3780Link s script language is documented in the 3780Link User s Guide and in the help file The 3780Link GUI Window The 3780Link GUI window consists of a menu toolbar and link state indicator The layout of the window is shown below 3780Link for Windows Toolbar 3780Link for Windows Port 1 Connections Transfers File Settings Stats Trace Quit Help Menu alako a ola sl sf SI 2 a 2 DISCONNECTED Link State The 3780Link GUI Toolbar There are 13 toolbar buttons to control a communications session using 3780Link GUI The buttons and their equivalent keyboard commands are shown below Auto Dial Ctrl D Auto Answer Ctrl A Connect Ctrl 0 BISDA Disconnect Ctrl I Send File Ctrl F Printer Setup Ctrl P me Punch Setup Ctrl U NE Mele Receiving Files Using 3780Link GUI Kill 170 Ctrl K Run Script Ctrl R Stop Script Execution View Reset Statistics Exit 3780Link Ctrl Q Help F1 3780Link GUI does not have a function that explicitly allows data to be received When data is sent from the remote system once a communication session is established it is received automatically and is stored according to the Printer Punch Defaults SmartSync DCP Installation Guide Running 3780Link SO for Attended Communications Sessions The 3780Link SO program allows you to
15. pped file If the optional n is included 3780Link waits n seconds for a file to be dropped As an example consider the following script file named dropscri s loop CALL d GOTO loop When running this script file 3780Link SO waits indefinitely for another script file to be dropped effectively resulting in a script file server When a script file is eventually dropped the file is executed and control returns to dropscri s after the dropped script completes MESS_BOX EXE Message Box Display Program If you would like a message box to display at some point during script processing add the following line to your script file EXEC mess _box exe text title When this command is encountered script processing will stop and a message box containing the specified text and title string will appear on the screen Script processing will resume when the operator presses the OK button in the message box SmartSync DCP Installation Guide TXLAT EXE Trace Translation Program The TXLAT utility accepts 3780Link trace files as input and converts the hexadecimal EBCDIC codes of these files into a more readable format TXLAT runs only from within a MS DOS session The DOS command line syntax of TXLAT is txlat b x lt file gt i lt file gt o lt file gt b suppress translation of non protocol trace characters use if binary data is expected X specify an alternate translation table file corresponds
16. race information is handled by running Deptrace thereafter The trace data retrieved by Deptrace is automatically written to both the screen and an output file If you ve configured one SmartSync DCP the default file name is trace x where x is the port number If you ve configured more than one board the default file name is trace xy where x is the port number and y is the board number By default the output file is reset when it reaches 100 000 bytes This enables Deptrace to run continuously without overflowing disk storage The optional command line switches for Deptrace are described below b board Board number to trace 1 6 The b switch specifies which SmartSync DCP Deptrace is to access The board number corresponds to the order in which they were configured If omitted Deptrace defaults to board 1 p port Port number to trace 1 8 The p switch specifies which of the SmartSync DCP ports to monitor for trace data If omitted Deptrace defaults to monitor port 1 f name Alternative trace file name The f switch specifies a file other than the default to record trace data m size Maximum size of trace file kilobytes The m switch changes the default maximum output file size By default the trace file is reset when it exceeds 100 000 bytes To change this default specify the maximum file size in kilobytes 1 024 bytes For example m50 establishes the maximum file size to be 50K bytes 3780Link for
17. run completely automated unattended communications sessions There are three ways to start 3780Link SO e Click on the 3780Link Script Only icon and then click the open file button on the toolbar to specify the script file you wish to run e Add s lt filename gt to the command line of the 3780Link SO program item short cut where lt filename gt is the name of your script file Doing this will automatically run the selected script file when double clicking upon the icon Drag and drop your script file onto an active 3780Link SO window The 3780Link SO Window When not minimized 3780Link SO runs in a window with the script commands echoed as they are performed After an introduction screen you will see a window like the one below 3780Link Port 1 TESTRCY S Nisciptsiesto s z A Z A a 2 D1 Line 1 trace fon b 32000 Al race Turned On D1 Line 2 nato 0 Configuration Change Accepted 1168 Di Line 3 log 3780log rcv Di Line 4 ptr temp rev Printer Defined TEMP RCY conn t 0 vv La DISCONNECTED 4 13 PM 4 3780Link for Windows The 3780Link SO Toolbar There are 10 toolbar buttons to control the execution of your script files The buttons and their equivalent keyboard commands are shown below Run Script Ctrl R l Turn Trace On Off Alt T Stop Script Execution Edit lt script file gt Alt E Skip to Next Command Alt N A Run the Configurator Alt C Rerun S
18. script command to be sent from a client applic WAITSIG t 0 DISCONNECTED 4 27PM 4 3780Link for Windows The client program window is shown below Enter script commands here Script results are displayed here Send command Receive signal from w3780s0 Received Receive Mode Cancel command Synchronous Asynchronous Terminate 3780Link Client Statys IDLE Wait timeout for command to complete 3780Link Client status WAITING TO RECEIVE SENDING REPLY IDLE SENDING WAITING FOR REPLY Synchronous wait for script results to be returned Asynchronous do not wait for results The client program can be used to exercise limited interactive control over a 3780Link SO session This program allows you to enter script commands from the keyboard and have them executed by 3780Link SO The results of each command are returned and displayed Caution The client program is provided as an example program demonstrating how commands may be piped to 3780Link SO from another program It is not intended for production use and you may experience difficulties if you attempt to use it in such a manner 20 SmartSync DCP Installation Guide As you enter commands via the command prompt you can watch as they execute in the 3780Link SO window Note The time out parameter must be long enough for 3780Link SO to complete the requested command For example if you ask 3780Link SO to send
19. size of debug file kilobytes The m switch changes the default maximum output file size By default the debug file is reset when it exceeds 100 000 bytes To change this default specify the maximum file size in kilobytes 1 024 bytes For example m50 establishes the maximum file size to be 50K bytes S Silent mode The s switch prevents Depdebug from echoing debug messages to the screen If the message DEBUG TRACKING MESSAGES LOST appears on the screen or in your debug output file when running Depdebug use silent mode Silent mode may also be entered by unchecking the Echo to Screen menu item under the Options menu l Priority mode The l switch causes Depdebug to run at a higher priority level If the message DEBUG TRACKING MESSAGES LOST appears on the screen or in your debug output file when running Depdebug first try using silent mode If silent mode does not prevent the messages from appearing use priority mode When using priority mode be sure to run Depdebug in the background to lessen the effect on other running processes SmartSync DCP Installation Guide DCPTRACE SmartSync DCP Trace Dump Utility This program is used to access the line trace buffers updated by SmartSync DCP BSC processes This utility is strictly for diagnostic purposes and should only be used under the direction of Serengeti Technical Support You must turn on line trace from within 3780Link but the dumping of the line t
20. tility program Software Removal To remove the 3780Link software click on the Uninstall 3780Link icon in the 3780Link program folder or click on Add Remove Programs in the Control Panel and follow the instructions on the screen All programs and files that were originally installed on your machine are removed Any files residing in the installation directory created after installation are not removed SmartSync DCP Installation Guide Running 3780Link GUI for the First Time The first time that you run 3780Link GUI you must configure the modem type to match the type of modem you will be using 3780Link GUI will automatically display the Modify Hardware Settings window so that you may select the modem type In addition it may be necessary for you to modify the Link Settings Terminal Settings and Transfer Settings to match the requirements of the remote system s to which you will be connecting After the configuration settings have been saved you are ready to begin a communications session A communications session may be started in one of the following two ways 1 Use the 3780Link GUI menus to interactively issue commands such as Auto Dial Send File and Disconnect 2 Runa script file that automates the entire communications session A script file can be run either through the Transfers Run Script menu option of 3780Link GUI or through the 3780Link SO program You may customize one of the sample script files or create y
21. to x switch in 3780Link i specify the input trace file 0 specify the translated output file AMXBSC EXE SmartSync DCP Download File The amxbsc exe file is downloaded to each SmartSync DCP prior to loading 3780Link by running the Depload program that is described below A download need only be performed once before the first use of 3780Link IMPORTANT This file is NOT an executable Windows program DCPLOAD SmartSync DCP Download Utility This program is used to initialize each SmartSync DCP co processor and download the amxbsc exe file The amxbsc exe file is expected to be found in the current working directory The optional command line switches for Depload are described below b board Specific board number to load 1 6 The b switch specifies which SmartSync DCP Depload is to load You must indicate the board number 1 through 6 as appropriate The board number 3780Link for Windows corresponds to the order in which they were configured If omitted Depload loads all boards found f name Path File to download The f switch specifies the full path name of amxbsc exe if it is not in the currently logged subdirectory For example dcpload f other_dir amxbsc exe DCPPEEK SmartSync DCP BSC Process Status Utility This program is used to peek at each SmartSync DCP and verify that the various processes running in the co processor are active This utility is intended prim

Download Pdf Manuals