Home

SECO-LARM USA EV-6120-P3WQ User's Manual

image

Contents

1. 1 3 Sony Super HAD II CCD 3 7mm Lens 12VDC Operation Multiple mounting angles camera can view out of the side or bottom of the housing NTSC PAL Model Number Resolution Lens Size EV 6120 N3WQ 480 TV Lines 3 7mm EV 6620 N3WQ 600 TV Lines 3 7mm EV 6120 P3WQ 480 TV Lines 3 7mm EV 6620 P3WQ 600 TV Lines 3 7mm Covert Ceiling Mount Camera Note Model numbers that end with Q or that have a round green Q sticker signify RoHS compliant products Manual ENFORCER Covert Ceiling Mount Camera 2 SECO LARM U S A Inc 1 x Camera 1 x Manual 2 x Mounting screws 2 x Screw anchors 1 x DC Plug with terminal block NTSC EV 6120 N3WQ EV 6620 N3WQ PAL EV 6120 P3WQ EV 6620 P3WQ Type Covert Ceiling Mount Camera CCD 1 3 Sony Super HAD II CCD Resolution 480 TVL 600 TVL Pickup elements NTSC 510x492 pixels 768x494 pixels PAL 500x582 pixels 752x582 pixels Sync Internal Video output 1 1Vp p composite video 75 S N ratio gt 48dB AGC OFF Shutter control 1 60 1 100 000 sec Gain control Auto IP rating N A Operating voltage 12VDC Current draw 100mA Operating temperature 14 122 F 10 50 C Dimensions 43 4 x 21 4 120 x 57 mm Weight 5 oz 135g Dimensions Specifications Parts List 43 4 120mm 21 4 57mm ENFORCER Covert Ceiling Mount Camera SECO LARM U
2. S A Inc 3 SECO LARM U S A Inc 33 3 1 Run a 12VDC power supply wire and a video cable with a male BNC connector through the ceiling to where the camera is to be mounted 2 Temporarily connect the camera to the 12VDC power supply Do not cut the DC jack or female BNC plug as the warranty will be voided If needed use the included SECO LARM DC plug with terminal block 3 Temporarily connect the camera s female BNC jack to the video cable s male BNC plug While watching the monitor hold the camera by hand against the ceiling where it is to be mounted then twist the camera until it is certain that this mounting location is correct Use a pencil to mark the location of the two screw holes in the bracket 4 If the camera angle needs to be adjusted remove the camera module and loosen the adjustment Installation screws Rotate the camera module to the correct angle Tighten the adjustment screws and replace the camera module in the housing 5 To adjust the camera for bottom view remove the camera module and loosen the adjustment screws Rotate the camera to face the bottom viewing hole Tighten the adjustment screws and replace the camera module in the housing 6 Disconnect the 12VDC power supply and video cable 7 Mount the camera to the ceiling using the two included mounting screws 8 Reconnect the 12VDC power supply and video cable Turn the monitor on and make sure the camera
3. is sending the proper video signal 9 Do a final test of the video camera and monitor 1 Please read this manual carefully and keep it for future reference 2 Use the camera within given temperature and electricity limits 3 Do not point the camera at the sun Heat could damage the camera even when not in use 4 Do not mount the camera in areas exposed to radiation strong magnetic fields or strong electrical signals 5 Do not open or disassemble the camera There are no field serviceable parts inside 6 Do not drop the camera or subject it to strong vibrations Before Starting Mounting screws Side viewing hole Mounting screws Bottom viewing hole Overview DC Plug with terminal block Important Do not cut the DC jack or the female BNC connector as this will void the warranty Camera housing Female BNC connector DC jack Camera module Camera module mounting screws Adjustment screw Adjustment screw Bottom Viewing Angle Adjust the camera to face the bottom viewing hole ENFORCER Covert Ceiling Mount Camera 4 SECO LARM U S A Inc IMPORTANT Users and installers of this product are responsible for ensuring this product complies with all national state and local laws and statutes related to monitoring and recording audio and video signals SECO LARM will not be held responsible for the use of this product in violation of any curren
4. ck that the power supply s polarity is correct Check that the monitor is powered up Check that the video cable connecting the camera to the monitor is connected properly Clean the lens using a soft clean cloth Check that the light source is adequate Adjust the monitor s contrast knob Change the position of the camera Change the position of the camera Change the position of the camera Check that the correct power supply is in use Troubleshooting
5. or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2012 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM SECO LARM U S A Inc 16842 Millikan Avenue Irvine CA 92606 Website www seco larm com Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com Mi6x20 N3WQ_1208 docx Made in China PICSN4 The screen is blank The screen image is dim The screen image has poor contrast The screen image flickers The screen image is distorted The camera case is hot Check that the camera is powered up Che
6. t laws or statutes WARNING Stop using the camera if you see a malfunction such as smoke or unusual heat as it could cause fire or electric shock Do not open the case of this device as there are no field serviceable components inside FCC COMPLIANCE STATEMENT Information to the user This equipment has been tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage

Download Pdf Manuals

image

Related Search

Related Contents

User Guide - TWA Paris  Z700-A82 / 120V Treadmill Service Manual  ·DIIIQ ~ITM. - Nova-Tech International, Inc  PayEasy +HR - A&A Computers Ltd  Manual de instrucciones Balanza para determinación de densidad  (3`TFT)(SUNPLUS 8202RD)E F1301006.cdr  取扱説明書  Mode d`emploi  guide de dépannage  Mode d`emploi et conseils malins - Lave linge  

Copyright © All rights reserved.
Failed to retrieve file