Home

SeaLand VACUFLUSH User's Manual

image

Contents

1. IBLE If the red light seems to stay on longer than when the system was originally installed it is probably time to replace the duckbill valves in the vacuum pump If there is no vacuum in the toilet and the green light is on a blockage has probably occurred between the toilet bowl and the vacuum tank If there is no vacuum present in the toilet after several minutes it may indicate a blockage at the outlet of the vacuum tank or inlet of the vacuum pump DIMENSIONAL SPECIFICATIONS CIRCUIT BREAKER 2 7 8 inch wich RED UGHT 73mm LUFT PEDAL TO ADD WATER i VACUFLUSH 4 3 4 inch 120 6mm fs 5 16 inch 2 7 16 inch 8mm 62mm MINIMUM CLEARANCE BEHIND WALL PARTS LIST Part No Description 600342400 VacuFlush Status Panel Housing 600340471 6 x 1 Long Oval Phillips Head Screw 600343786 VacuFlush Status Panel Face Plate 600342493 Red Lens 600342652 Circuit Breaker 12VDC 10 amp 600342495 Green Lens 600340488 6 x 3 8 Long Pan Phillips Head Screw 385310636 VacuFlush Status Panel 12 VDC 385310637 VacuFlush Status Panel 24 32 VDC CONTROL PANEL MOUNTING TEMPLATE AZ 19 82 inch 10 32 mm 1 I inch 2 7 16 inch 41 28 mm 62 mm 1 4 inch jx 3 7 16 inch 87 30 mm gt 3 32 inch dia 6 35 mm 2 36 mm 3 15 16 inch 100 00 mm gt WIRING DIAGRAM VacuFlush Status Panel with V
2. VACUFLUSH STATUS PANEL PRODUCT GUIDE O Dometic spre Dometic Corporation Sanitation Systems 13128 State Rt 226 P O Box 38 Big Prairie OH 44611 0038 USA SeaLand Product Hotline 1 800 321 9886 8 00 a m 5 00 p m ET TABLE OF CONTENTS Safety Instructions 2 Dimensional Specifications 4 Electrical Specifications 2 Parts List 4 Product Features 2 Control Panel Mounting Template 5 Installation Instructions 3 Wiring Diagrams 5 7 How to Use 3 Warranty Information 8 SAFETY INSTRUCTIONS WARNING When using this device always exercise basic safety precautions including the following e Read all instructions before use or installation e Never connect this device to any electrical circuit with other than 12 24 or 32 volt Direct Current or exceed the amperage draw specified below e Never install use or service any component of this device in an atmosphere with potentially flammable or explosive vapors SPECIFICATIONS Product Name VacuFlush Status Panel Shipping Information Carton Size 6 in x 6 in x 4 in 15 2 cm x 15 2 cm x 10 2 cm Electrical Current and Wattage per Indicator Light Magnetic manual reset circuit breaker F L AMPS TRIP AMPS 5 6 75 10 13 5 Maximum wire size per terminal block pin 12 gauge PRODUCT FEATURES e Continuously monitors status of vacuum for proper operation e Magnetic circuit breaker designed to protect the vacuum pump from damage
3. acuum Tank amp Vacuum Pump VACU FLUSH STATUS PANEL 24 32VDC MODEL ONLY VACU FLUSH STATUS PANEL 12VDC MODEL ONLY VACUUM SWITCH MTD ON VACUUM TANK VACUUM SWITCH MTD ON VACUUM TANK 24 OR 32 VACUUM PUMP This page intentionally left blank WIRING DIAGRAMS VacuFlush Status Panel with Vacuum Generator VACU FLUSH STATUS PANEL 12VDC VACU FLUSH STATUS PANEL 24 32VDC ener 24 OR 32VDC Vatni ames J VACUUM PUMP RED lt P RED VACUUM SWITCH Sk VACUUM SWITCH P i lt lt BLK WT VAGUUMGENERATOR12V0G VACUUM GENERATOR 24vDG MINIMUM WIRE SIZE 14 GA STRANDED COPPER HEAVY LINES DESIGNATE WIRE ROUTED BY INSTALLER VacuFlush Status Panel with Vacuum Holding Tank VACU FLUSH STATUS PANEL 12VDC HEAVY LINES DESIGNATE WIRES ROUTED BY INSTALLER 12 VDC 12 VDC TANK FULL RELA AIR RED S N O O GRN PUMP BLK B B a STA MOTOR ADD JUMPER WIRE A AN A 87 VACUUM SWITCH 85 86 BLK o gt WHT O O WHT O TANK FULL FLOAT SWITCH l wnr 1 6 AMP AT 12 VDC BLK VACUUM HOLDING TANK MANUFACTURER S ONE YEAR LIMITED WARRANTY Dometic Corporation warrants to the original purchaser only that this product if used for personal family or household purposes is free from defects in material and workmanship for a period of one year from the date of purchase If this Dometic product is placed in commercial or business use it wil
4. e Allows the boater to shut the system down during the night Deluxe panel complements bathroom decor e Indicates loss of electrical power or system power off INSTALLATION INSTRUCTIONS 1 Select a mounting location away from direct contact with water and oil Dry locations in the head salon or galley are most desirable Confirm clearances for the panel behind walls and bulkheads Cut out mounting hole for control panel See template on page 5 for cut out and hole locations Do not mount panel housing until wiring is routed and secured Route wires using the wiring diagram on pages 5 amp 7 Mount panel housing with the 4 6 x 1 long black oval head screws provided Insert the 2 small tabs on the left side of the face plate into the housing and snap the large tab on the right side of the face plate into the housing to secure it NOOR WD HOW TO USE THE VACUFLUSH STATUS PANEL Under normal operating conditions the red lamp will light after each flush until the pump recharges the vacuum to proper operating level then the green lamp will light If there is constant green light to red light cycling between flushes it may indicate a leak in the vacuum system The vacuum pump will normally operate automatically every so often to recharge the vacuum A continuous red light indicates an extended loss in vacuum as a result of a blockage pump failure or massive vacuum leak TURN OFF THE SYSTEM AND REPAIR AS SOON AS POSS
5. e limitations may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state To obtain warranty service first contact your local dealer from whom you purchased this product M Dometic Sraka Dometic Corporation Sanitation Systems 13128 State Rt 226 P O Box 38 Big Prairie OH 44611 0038 USA SeaLand Product Hotline 1 800 321 9886 8 00 a m 5 00 p m ET Registered Trademark of Dometic Corporation Dometic Corporation 600342639 3 04
6. l be warranted to the original purchaser only to be free of defects in material and workmanship for a period of ninety 90 days from the date of purchase Dometic reserves the right to replace or repair any part of this product that proves upon inspection by Dometic to be defective in material or workmanship All labor and transportation costs or charges incidental to warranty service are to be borne by the purchaser user EXCLUSIONS IN NO EVENT SHALL DOMETIC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR DAMAGES RESULTING FROM IMPROPER INSTALLATION OR FOR DAMAGES CAUSED BY NEGLECT ABUSE ALTERATION OR USE OF UNAUTHORIZED COMPONENTS ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FORANY PARTICULAR PURPOSE ARE LIMITED TOA PERIOD OF ONE YEAR FROM DATE OF PURCHASE IMPLIED WARRANTIES No person is authorized to change add to or create any warranty or obligation other than that set forth herein Implied warranties including those of merchantability and fitness for a particular purpose are limited to one 1 year from the date of purchase for products used for personal family or household purposes and ninety 90 days from the date of purchase for products placed in commercial or business use OTHER RIGHTS Some states do not allow limitations on the duration of an implied warranty and some states do not allow exclusions or limitations regarding incidental or consequential damages so the abov