1. INSTRUCTION MANUAL VCC 9684VA Color CCD Camera About this manual Before installing and using the camera please read this manual carefully Be sure to keep it handy for later reference Ceiling Installed Wall Installed dD g D E D 3 7 Surface routing 1 1 Surface routing Cutout Rib mark Safety Guard 1 THIS SYMBOL INDICATES THAT THERE ARE IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THIS UNIT WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE For the customers in Canada This Class B digital apparatus complies with Canadian ICES 003 Pour la client le canadienne Cet appareil numerique de la Classe B est conforme la norme NMB 003 du Canada This installation should be made by a qualified service person and should conform to all local codes This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular
2. 48 dB AGC off More than 50 dB f 2 8 8 mm F0 95 1 7 On the ceiling Pan 100 degrees Tilt 0 90 degrees Pan 90 degrees Tilt 0 90 degrees OFF Multi spot metering High Normal Center zone Video S N ratio Vari focal lens Rotation range On the wall Backlight compensation metering White balance ATW Manual Electronic shutter 1 60 1 100 1 1000 1 2000 sec Aperture compensation Sharp Normal Sync system Operating Environment Internal sync Line lock Temperature 10 C 50 C 14 F 122 F Humidity less than 90 RH no condensation Power supply 24 V AC 10 60 Hz 12 15 V DC Power consumption approx 2 4W Weight approx 500 g 16 oz Accessory Screw x1 Warranty x1 Appearance and specifications are subject to change without prior notice or obligations SERVICE The camera is a precision instrument Handle it carefully and always follow the safety precautions If the camera requires service never try to repair it yourself or open the casing For servicing maintenance or repairs consult your dealer or an Authorized Sanyo Service Center E Dimensions 151 6 0 100 4 0 Unit mm inch INSTALLING BASE PLATE AND CONNECTIONS Open the base plate Ceiling Installed Point the arrow 4 in the same direction as the lens orientation A e Length 35 mm 1 4 in or more e Diameter 3 5 to 5 0 mm 0 1 to 0 2 in e Height
3. angle of illumination and other factors while observing the monitor Camera adjustments settings CIID The camera comes pre adjusted and ready to install at the time of factory shipment but you can make adjustments or settings if you need If you have trouble adjusting the camera consult your dealer or an Authorized Sanyo Service Center Electronic shutter speed setting unit second 1 60 1 100 1 1000 1 2000 Switch1 MSB Switch2 LSB gt e Using the high speed electronic shutter indoors with low lighting will give darker pictures In such a case add some lights to make sure the lighting is sufficient e If the lighting is very bright pay attention to the light angle in order to avoid or minimize the smear phenomenon effect Aperture compensation Sharp outline Normal outline 3 D Only when using an auto iris lens Multi spot metering High Normal Backlight compensation to the entire screen H H H H 4 5 4 5 Center zone metering Backlight compensation g O to the central portion of 4 5 the screen OFF og 4 5 If the background of the object is extremely dark set to Center zone metering White balance color compensation Auto Tracing White balance ATW oO A BLUE 6 Turn clockwise to augment the color Manual White Balance Sync setting Line Lock Synchroni
4. humidity and dust To prevent damage do not install the unit where there is greasy smoke or steam where the humidity may get too high or where there is a lot of dust E Protect from high temperatures Do not install close to stoves or other heat sources such as spotlights etc or where it could be subject to direct sunlight as this could cause deformation discoloration or other damages Be careful when installing close to the ceiling in a kitchen or boiler room as the temperature may rise to high levels E Cleaning e Dirt can be removed from the cabinet by wiping it with a soft cloth To remove stains wipe with a soft cloth moistened with a soft detergent solution and wrung dry then dry by wiping with a soft cloth Do not use benzine thinner or other chemical products on the cabinet as this may cause deformation and paint peeling Before using a chemical cloth make sure to read all accompanying instructions Make sure that no plastic or rubber material comes into contact with the cabinet for a long period of time as this may cause damage or paint peeling SPECIFICATIONS Scanning system NTSC standard 525 lines 60 fields sec Image sensor 1 4 interline transfer method CCD Number of effective pixels 768 H x 494 V Horizontal resolution 540 TV lines typical Minimum illumination approx Video output 0 5 Ix F0 95 1 0 V p p 75 Q composite BNC UTP support VA 10T option board More than
5. installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by Sanyo may void the user s authority to operate this camera PRINTED WITH SOYINK _ SANYO Ww SANYO 1AC6P1P3265 L5CJ2 US 1107KP HS SANYO Electric Co Ltd Printed in China PRECAUTIONS Important Be careful when opening holes for installing the unit Work with the power and video cables pulled out for easy installation Make sure to properly perform waterproofing for the ceiling or wall where you are installing the unit Make sure that the surface in the installation location has no unevenness and is strong enough to bea
6. lens in the correct direction 1 Remove the black screw 2 Turn the lens in the arrow direction to reverse the orientation Confirm that the dials are located at the top Temporarily tighten the removed black screw A Black screw B Connect the cables from the wall B Mount the camera unit to the base plate Push the camera unit until it clicks taking care not to pinch the cable Make sure that the camera unit and base plate fit perfectly Espa ol ADJUSTING CAMERA IMAGE Hi Checks on monitor Connect a portable monitor MONITOR A dedicated MONITOR OUT connector is provided for portable monitor Ceiling Installed Wall Installed Do not touch the lens and lens barrel When rotating the lens unit make sure a metal edge does not damage the cables Focus Loosen the focus ring knob and turn the focus ring D to focus on the object Loosen the zoom ring knob A and turn the zoom ring to zoom in or out When finished tighten the zoom and focus ring D knobs A securely gt When monitoring lighting or other extremely bright objects which exceed the maximum required illumination smearing may occur in the vertical or horizontal direction either above and below the high brightness object or as a perpendicular band In such a case adjust the
7. of screw head 5 mm 0 2 in or less washer included Make sure to tighten the screws properly Using screws of sizes other than specified may cause the unit to fall Wall Installed Place the base plate so that the arrow points downward Monitor Connection Cable type Length RG 59U 3C 2V 250 m 273 yds max RG 6U 5C 2V 500 m 547 yds max RG 11U 7C 2V 600 m 656 yds max e When using an RG 59U 3C 2V cable do not let it dangle in the air or attach it to piping e If you use a cable other than the types above the image or sync signal will be attenuated and will not be transmitted correctly Power Supply Connection E With AC 24 V E With DC 12 V Check that polarity is correct RED p gt a For the connections use cables thicker than 18 AWG RED een a gt Reverse side INSTALLATION 1 Remove the dome cover Preparation B Remove the blue tape air cushion and screw D Do not touch the lens and lens barrel Turn the lens Loosenthe Installing on the Ceiling 1 Connect the cables from the ceiling B Mount the camera unit to the base plate Push the camera unit until it clicks taking care not to pinch the cable Supplied Make sure that the camera unit and base plate fit perfectly black screw 90 degrees clockwise O Screw g Installing on the Wall 1 Set the
8. r the total weight of the unit Install this unit in an environment where the temperature range stays between 10 C and 50 C 14 F and 122 F no condensation allowed As a precaution against static electricity damage touch a nearby metal object door knob etc to dissipate static electricity in your body before touching this unit E In case of a problem Do not use the unit if smoke or a strange odor comes from the unit or if it seems not to function correctly Turn off the power immediately and disconnect the power cord and then consult your dealer or an Authorized Sanyo Service Center E Do not open or modify Do not open the cabinet as it may be dangerous and cause damage to the unit For repairs consult your dealer or an Authorized Sanyo Service Center E Do not put objects inside the unit Make sure that no metal objects or flammable substance get inside the unit If used with a foreign object inside it could cause a fire a short circuit or damage Be careful to protect the unit from rain sea water etc If water or liquid gets inside the unit turn off the power immediately and disconnect the power cord and then consult your dealer or an Authorized Sanyo Service Center E Be careful when handling the unit To prevent damage do not drop the unit or subject it to strong shock or vibration E Do not install this unit close to magnetic fields The magnetic fields may result in unstable operation E Protect from
9. zes the unit with power frequency Pe PHASE 7 Internal sync Adjust the roll by turning the LINE PHASE dial on the second and subsequent cameras If the vertical roll cannot be corrected by adjusting the LINE PHASE dial on the second and subsequent cameras try adjusting the LINE PHASE dial on the first camera If it still cannot be corrected please check that the polarity of the power cords of all connected devices is correct Lens iris level adjustment If the entire image is too dark or too bright adjust the condition Low darker High brighter After finishing camera adjustments settings oO Tighten the screw CO PL M R For wall installation securely tighten the screw you temporarily tightened B Install the dome cover Push the dome cover until it clicks 2 While holding down the dome cover turn it in the direction of the arrow until the lens is completely visible through the camera window

Download Pdf Manuals

image

Related Search

Related Contents

Polycom 1725-36097-001 Cordless Telephone User Manual  Philips CE135BT  QuickSpecs  Enox BFL-0622LED-DVD 22" Full HD Black LED TV  MTX Audio MTX Thunder 4405 User's Manual  AudioSonic RD-1559  Kalorik TKM 20208 User's Manual  American Standard 2475.500.002 Installation Guide  Kenroy Home 92092COP Installation Guide    