Home
Sanyo VCC-5774 User's Manual
Contents
1. damage the camera and prevent proper installation 1 Remove the lens mount cap from the camera 2 Install the auto iris lens CS mount type lens Carefully align the lens mount with the camera opening then turn the lens slowly to install it C mount type lens Install the supplied C mount adaptor on the lens mount then carefully align the lens mount with the camera opening and turn the lens slowly to install it 3 Connect the lens plug to the lens iris output connector LENS on the side of the camera The plug shape may not correspond to the terminal on the camera In such a case remove the original plug and using a soldering iron connect the supplied lens iris plug according to the diagram Refer to page 10 MOUNTING THE LENS YS Pin layout Brake coil Brake coil Drive coil Drive coil E Rewiring the lens cable in the lens iris plug 1 Prepare the lens cable Cut the cable at the plug then remove approx 8 mm of the cable sheath and strip about 2 mm from each wire 2 Install the lens iris plug Solder the cable to the pins following the correct pin layout refer to the table and illustrations then close the plug cover WE Compatible auto iris lenses 1 3 inch COSMICAR DC type lens e Standard angle f 8 mm TS812E Equivalent e Wide angle f 4 mm TS412E Equivalent e Ultra wide angle f 2 8 mm TS212E Equivalent CONNECTIONS Basic connection for monitoring or
2. recording gt gt gt lt Li lt i lt Video signal connections b gt gt VIDEO IN D gt VIDEO OUT English 11 Note The polarities for the 24 V AC and the 12 V DC input connectors are indicated on the rating label found on the unit back panel AC24V _ GND pc i2vs 2 Push to insert the cable DC 12 V connection DC12V CONNECTIONS The peripheral devices VCR monitor lens etc and cables are sold separately 1 Make the video signal connection between the camera and the monitor or timelapse VCR 2 Power supply choices e When using an AC 24 V power supply UL listed class 2 power supply make the connections as indicated in Fig 1 e When using a DC 12 V power supply make the connections as indicated in Fig 2 CAUTION e To prevent camera and or power supply failure pay close attention to polarity when making the connections e To prevent fire hazard any UL listed wire rated VW 1 should be used for the 24 V AC cable input terminal 3 Insert the plug of this power supply into a wall outlet Adjust the picture on the monitor using the Brightness and Contrast controls W Coaxial cable type and maximum length e Cable type RG 59U 3C 2V 250 m maximum e Cable type RG 6U 5C 2V 500 m maximum e Cable type RG 11U 7C 2V 600 m m
3. SANYO INSTRUCTION MANUAL VCC 5774 VCC 5774M COLOR CCD CAMERA r Zz rA Z A rA Z Z A About this manual Before installing and using the camera please read this manual carefully Be sure to keep it handy for later reference SANYO INDUSTRIAL VIDEO COLOR VIDEO CAMERA LIMITED WARRANTY OBLIGATIONS In order to obtain warranty service the product must be delivered to and picked up from an Authorized Sanyo Service Center at the user s expense unless specifically stated otherwise in this warranty The names and addresses of Authorized Sanyo Service Centers may be obtained by calling the toll free number listed below For product operation authorized service center referral service assistance or problem resolution call CUSTOMER INFORMATION 1 800 421 5013 Weekdays 8 30 AM 5 00 PM Pacific Time For accessories and or parts call PARTS ORDER INFORMATION 1 800 726 9662 Weekdays 8 30 AM 5 00 PM Pacific Time THIS WARRANTY IS VALID ONLY ON SANYO PRODUCTS PURCHASED OR RENTED IN THE UNITED STATES OF AMERICA EXCLUDING ALL U S TERRITORIES AND PROTECTORATES THIS WARRANTY APPLIES ONLY TO THE ORIGINAL RETAIL PURCHASER OR END USER THE ORIGINAL DATED BILL OF SALE SALES SLIP OR RENTAL AGREEMENT MUST BE SUBMITTED TO THE AUTHORIZED SANYO SERVICE CENTER AT THE TIME WARRANTY SERVICE IS REQUESTED Subject to the OBLIGATIONS above and EXCLUSIONS below SANYO Fisher Company warrants this SANYO product against def
4. aximum Note Use CCTV Video grade coaxial cable 12 English FLANGE BACK ADJUSTMENT screw English 13 If the pick up surface is not correctly positioned with relation to the lens focal point the picture will be out of focus in particular when using auto iris power zoom lenses sold separately If that is the case adjust the flange back position as described below 1 Before installing the lens check that the two flange back lock screws have been tightened If the flange back lock screws are loose the CS mount ring will not be secured and it will not be possible to adjust the flange back 2 Fully install the lens then loosen the two flange back lock screws 3 Set the zoom lens to the maximum telephoto position TELE then set the focus using the focus ring on the lens 4 Set the zoom lens to the maximum wide angle position WIDE then set the focus by turning the CS mount ring 5 Repeat steps 3 and 4 until the image stays in focus when changing from a telephoto shot to a wide angle shot When the setting is complete tighten the flange back lock screws SETTINGS H Line phase adjustment When using a camera switcher to connect 2 cameras or more to one monitor there may be a vertical roll of the images when switched In such a case set as described below 1 Set the Sync switch to the L L position 2 Switch the display on the monitor from camera 1 to camera 2 Adjust the LINE PHASE volume on camera 2 until th
5. e vertical roll of the image stops If more than two cameras are used please repeat this procedure for all the cameras CAUTION If the vertical roll cannot be corrected by setting the LINE PHASE volume on camera 2 try setting the LINE PHASE volume on camera 1 If it still cannot be corrected please check that the polarity of the power cords of all connected devices is correct LINE A PHASE DADA Ya E N a Monitor 14 English SETTINGS H Lens iris adjustment If using a DC type auto iris lens you will need to set the LEVEL volume when shooting in the conditions described below Counterclockwise To decrease the brightness Clockwise To increase the brightness e If shooting simultaneously in a dark room and through a bright window e If the subject background is extremely bright or dark e If the brightness of the picture on the monitor is not correct English 15 SETTINGS E E Electronic iris function setting Under normal conditions set the El switch to the El OFF position and use an auto iris lens However if you have a manual lens or fixed iris lens set the lens aperture to the shortest F stop and set the El switch to the El ON position If conditions are outside the electronic iris operation range or more than the maximum brightness it will cause saturation of the CCD In that case use a auto iris lens Note Please r
6. ects in materials and workmanship for the periods specified below SFC will repair or replace at its option the product and any of its parts which fail to conform to this warranty The warranty period commences on the date the product was first purchased or rented at retail LABOR PARTS IMAGE DEVICE 3 YEARS 3 YEARS 3 YEARS EXCLUSIONS This warranty does not cover A the adjustment of customer operated controls as explained in the appropriate model s instruction manual or B the repair of any product whose serial number has been altered defaced or removed This warranty shall not apply to the cabinet or cosmetic parts batteries or routine maintenance This warranty does not apply to uncrating setup installation removal of the product for repair or reinstallation of the product after repair This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of SFC including but not limited to any malfunction defect or failure caused by or resulting from unauthorized service or parts improper maintenance operation contrary to furnished instructions shipping or transit accidents modification or repair by the user abuse misuse neglect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear The foregoing is in lieu of all other expressed warranties and SFC does not assume or authorize any party to assume for it any other
7. efer to the specifications for dynamic range of the electronic iris El OFF EI ON INT L L CAUTION e The electronic iris is suitable for normal indoor use When the El switch is set to the EI ON position do not use an auto iris lens If used under fluorescent light the image may flicker In such a case change to incandescent lighting or set the El switch to the El OFF position and use an auto iris lens e When shooting bright subjects pay attention to the light angle in order to avoid or minimize the smear phenomenon effect 16 English TROUBLESHOOTING Before taking the camera for repairs please check below to make sure that the camera is used correctly If it still does not perform correctly please consult your dealer or a Sanyo Authorized Service Centre E No picture on the monitor screen e Is the power turned on to all connected devices Is the voltage correct e Are all the signal connecting cables correctly connected e Is the lighting sufficient e Has the lens cap been removed e Is the iris control correctly set E The picture is not clear Is the monitor correctly adjusted e Is the flange back position correctly set e Is the lens focus correctly adjusted e Are the lens surfaces clean If there is dust or finger prints on the lens the image quality will deteriorate To clean the lens use a soft cloth or a commercially available lens cleaning set SERVICE This cam
8. emical product on the cabinet as that may cause deformation and paint peeling Before using a chemical cloth make sure to read all accompanying instructions Make sure that no plastic or rubber material comes in contact with the cabinet for a long period of time as that may cause damage or paint peeling 6 English PARTS NAMES Camera mounting screw hole T CAUTION g When installing the camera select a location that can support the total weight of the camera and accessories Electronic iris function switch El OFF El ON Sync switch INT L L INT Internal sync position L L Line lock position Line phase adjustment volume LINE PHASE Lens iris level volume LEVEL Q Lens iris output connector LENS This 4 pin connector is used to send the DC control signal and power supply to an auto iris type lens English 7 PARTS NAMES Flange back lock screw CS mount ring Lens mount cap The cap is installed to protect the lens mount section Remove the lens mount cap before installing a lens Video output connector VIDEO OUT BNC type Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector 24 V AC or 12 V DC input terminal 24 V AC 12 V DC GND See page 11 8 English MOUNTING THE LENS Please use a DC type auto iris lens sold separately Checking the lens mount Do not use lense with a length L more than 5 mm If not that may
9. enees 11 FLANGE BACK ADJUSTMENT 13 SETTINGS eee ccecssceeeesessnteeeeennes 14 TROUBLESHOOTING 00 17 SPECIFICATIONS csccseeesessseee 18 ACCESSORIES ccscseeeeseesteeeeeees 20 FEATURES e Built in interline transfer method 1 3 CCD approx 410 000 picture elements e Low smear anti blooming low lag no burning and no geometric distortion using he CCD solid state image device e 100 solid state components giving excellent immunity to shock and vibration e Not subject to interference from magnetic or electrostatic fields e VCC 5774 AGC ON High sensitivity minimum required illumination is 1 4 lux F1 2 VCC 5774M AGC OFF High sensitivity minimum required illumination is 7 lux F1 2 e Horizontal resolution more than 480 TV lines Equipped with connectors for AC 24 V and DC 12 V power supply About VCC 5774M for a Casino Designed to produce the best picture especially under halogen light conditions with manual iris enses Design features Fixed Gain nstead of AGC Fixed Gain is adopted for pictures with less video noise under low light conditions Automatic White Balance AWB AWB is adjusted for best results under halogen ight Color temperature approx 3000K conditions Note Under fluorescent light or sun light conditions Approx 5000K a bluish image may be produced Gamma curve Gamma Curve makes dark parts of the image brighter With Line L
10. era is a precision instruments and if treated with care will provide years of satisfactory performance However in the event of a problem the owner is advised not to attempt to make repairs or open the cabinet Servicing should always be referred to your dealer or Sanyo Authorized Service Centre English 17 SPECIFICATIONS Scanning system NTSC standard TV system 525 TV lines 30 frames sec Interlace 2 1 interlace Image device 1 3 inch solid state image device CCD Picture elements 816 H x 494 V Effective picture elements 771 H x 492 V Synchronizing system Manual internal sync Line lock switching Resolution 480 TV lines horizontally 350 TV lines vertically Video output level 1 0 Vp p 75 ohms composite Video S N ratio More than 48 dB Minimum required illumination incandescent lighting AGC ON Approx 1 4 lux with a F 1 2 lens VCC 5774 AGC OFF Approx 7 lux with a F 1 2 lens VCC 5774M Backlight compensation ON condition only Electronic iris function Manual ON OFF switching Electronic iris range VCC 5774 only 1 4 lux to 70 000 lux F 1 2 lens 2 0 lux to 100 000 lux F 1 4 lens Flange back 12 5 mm 0 5 mm White balance ATW Lens mount CS mount Environmental conditions Temperature 10 C 50 C Humidity less than 90 no condensation Power supply 24 V AC or 12 V DC Power consumption 24 V AC 60 Hz 3 2 W with auto iris lens 2 5 W without auto iris lens 4 0 W wi
11. gets inside the camera disconnect the power cord immediately and consult your dealer or a Sanyo Authorized Service Centre Be careful to protect the camera from rain sea water etc English 5 E Be careful when handling the unit To prevent damages do not drop the camera or subject it to strong shock or vibration E Install away from electric or magnetic fields If installed close to a TV radio transmitter magnet electric motor transformer audio speakers the magnetic field they generate will distort the image E Protect from humidity and dust To prevent damages to the camera do not install it where there is greasy smoke or steam where the dampness may get too high or where there is a lot of dust PRECAUTIONS E Protect from high temperatures Do not install close to stoves or other heat generating devices such as spotlights etc or where it could be subject to direct sunlight as that could cause deformation discoloration or other damages Be careful when installing close to the ceiling in a kitchen or boiler room as the temperature may raise to high levels Install where the temperature range will stay between 10 C and 50 C no condensation E Cleaning Dirt can be removed from the cabinet by wiping it with a soft cloth To remove stains wipe with a soft cloth moistened with a soft detergent solution and wrung dry then wipe dry with dry soft cloth Do not use benzine thinner or other ch
12. obligation or liability SFC DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED WITH REGARD TO THIS PRODUCT INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS IN NO EVENT SHALL SFC BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE OWNERSHIP OR USE OF THIS PRODUCT OR FOR ANY DELAY IN THE PERFORMANCE OF ITS OBLIGATIONS UNDER THIS WARRANTY DUE TO CAUSES BEYOND ITS CONTROL SFC S LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM ANY CAUSE WHATSOEVER ARISING OUT OF OR IN CONNECTION WITH THE SALE USE OR OWNERSHIP OF THIS PRODUCT INCLUDING WARRANTOR S NEGLIGENCE ALLEGED DAMAGED OR DEFECTIIVE GOODS WHETHER SUCH DEFECTS ARE DISCOVERABLE OR LATENT SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCT ATTENTION For your protection in the event of theft or loss of this product please fill in the information below for you own personal records Model No Serial No Located on back or bottom side of unit Date of Purchase Purchase Price Where Purchased Depending on the conditions of use installation and environment please be sure to make the appropriate settings and adjustments If you need help with installation and or settings please consult your dealer English 1 CONTENTS INFORMATION TO USER 3 PRECAUTIONS cccceeeeessseeeees 5 PARTS NAMES 0 cccteceeeessseeeees 7 MOUNTING THE LENGS 0 9 CONNECTIONS cc ecseeecteeeeeee
13. ock mode noise might be noticeable In this case switch to Internal Sync Internal Sync is selected as default 2 English INFORMATION TO USER Safety Guard THIS SYMBOL INDICATES THAT THERE ARE IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THIS UNIT WARNING TO PREVENT THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE This installation should be made by a qualified service person and should conform to all local codes English 3 For the customers in Canada This Class B digital apparatus complies with Canadian ICES 003 Pour la client le canadienne Cet appareil numerique de la Classe B est conforme a la norme NMB 003 du Canada INFORMATION TO USER This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enco
14. th auto iris lens 2 7 W without auto iris lens Weight Approx 160 g without lens 12 15 V DC 18 English SPECIFICATIONS E Dimensions mm Features and specifications are subject to change without prior notice or obligations English 19 ACCESSORIES C mount adaptor 5 MM uu 1 pc The C mount adaptor must be used to be able to install a C mount lens on the camera Lens iris plug 4 PiN cccceceesee eee 1 pc 20 English
15. uraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by Sanyo may void the user s authority to operate this camera 4 English PRECAUTIONS E In case of problem Do not use the camera if smoke or a strange odour comes from the unit or if it seems not to function correctly Disconnect the power cord immediately and consult your dealer or a Sanyo Authorized Service Centre E Do not open or modify Do not open the cabinet as it may be dangerous and cause damage to the unit For internal settings and repairs consult your dealer or a Sanyo Authorized Service Centre E Do not put objects inside the unit Make sure that no metal objects or flammable substance get inside the camera If used with a foreign object inside it could cause a fire short circuits or damages If water or a liquid
Download Pdf Manuals
Related Search
Related Contents
Chillers Aermec NRC - NRCH Installation Manual (必要書類等について)(PDF:153KB) Samsung FC139STF Εγχειρίδιο χρήσης SH SERIES litestar Copyright © All rights reserved.
Failed to retrieve file